No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 10381780036050 | 9OS5211 | 9OS5211 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
2 | 10381780036043 | 9OS521 | 9OS521 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
3 | 10381780036036 | 9OS512P | 9OS512P | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | 2 | Integra Flow Regulating Valve Low Flow |
4 | 10381780036029 | 9OS512 | 9OS512 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
5 | 10381780036012 | 9OS502P | 9OS502P | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | 2 | Integra Flow Regulating Valve Low Flow |
6 | 10381780035442 | 909512P | 909512P | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | 2 | Integra Flow Regulating Valve Low Flow |
7 | 10381780035435 | 909508S | 909508S | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
8 | 10381780035428 | 909507S | 909507S | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
9 | 10381780035411 | 909500P | 909500P | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | 2 | Integra Flow Regulating Valve Low Flow |
10 | 10381780034247 | 951103 | 951103 | The Integra Y- Lumbar Catheter consists of a F5 (ID: 0.8 mm) radiopaque silicone The Integra Y- Lumbar Catheter consists of a F5 (ID: 0.8 mm) radiopaque silicone tubing with two open-ended arms (75 mm each) featuring several rows of inlet holes. The Y-shape consists of a 30 degree angle connection between the arms and the drainage catheter. The catheter overall length is 80 cm. A F5 radiopaque silicone Suture Clamp and a F8 -F5 radiopaque polypropylene Stepdown Connector (OD: 1.8 and 1.5 mm; ID: 0.8 mm) are supplied with the catheter. | JXG | Shunt, central nervous system and components | Lumbar Catheter | |
11 | 10381780033875 | 909515 | 909515 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
12 | 10381780033912 | 909521 | 909521 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
13 | 10381780033905 | 909520 | 909520 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
14 | 10381780033899 | 909519 | 909519 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
15 | 10381780033882 | 909518 | 909518 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
16 | 10381780033868 | 909514 | 909514 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
17 | 10381780033851 | 909513 | 909513 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
18 | 10381780033844 | 909512 | 909512 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
19 | 10381780033837 | 909511 | 909511 | The Integra Flow Regulating Valves Low Flow Lumbar are implantable hydrocephalu The Integra Flow Regulating Valves Low Flow Lumbar are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the lumbar subarachnoid region to the peritoneal cavity. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
20 | 10381780033820 | 909510 | 909510 | The Integra Flow Regulating Valves Low Flow Lumbar are implantable hydrocephalu The Integra Flow Regulating Valves Low Flow Lumbar are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the lumbar subarachnoid region to the peritoneal cavity. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
21 | 10381780033813 | 909508 | 909508 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
22 | 10381780033806 | 909507 | 909507 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
23 | 10381780033790 | 909506 | 909506 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
24 | 10381780033783 | 909505 | 909505 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
25 | 10381780033776 | 909504 | 909504 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
26 | 10381780033769 | 909503 | 909503 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
27 | 10381780033752 | 909502 | 909502 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
28 | 10381780033745 | 909501 | 909501 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
29 | 10381780033738 | 909500 | 909500 | The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hyd The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure. | JXG | Shunt, central nervous system and components | Integra Flow Regulating Valve Low Flow | |
30 | 10381780033530 | 903440 | 903440 | The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s effects on the fluid column within the drainage catheter of an implanted shunt system. The GCA consists of a silicone elastomer encased stainless steel housing with a ruby ball held in a stainless steel seat (in the vertical orientation) by two to four stainless steel balls. In the horizontal orientation, a minimal resistance to flow (<30mmH2O at 5ml/h) is added to the system, and in the vertical orientation: 140-170, 200-250 or 260-320mmH2O (at 5ml/h). | JXG | Shunt, central nervous system and components | Gravity Compensating Accessory | |
31 | 10381780033523 | 903435 | 903435 | The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s effects on the fluid column within the drainage catheter of an implanted shunt system. The GCA consists of a silicone elastomer encased stainless steel housing with a ruby ball held in a stainless steel seat (in the vertical orientation) by two to four stainless steel balls. In the horizontal orientation, a minimal resistance to flow (<30mmH2O at 5ml/h) is added to the system, and in the vertical orientation: 140-170, 200-250 or 260-320mmH2O (at 5ml/h). | JXG | Shunt, central nervous system and components | Gravity Compensating Accessory | |
32 | 10381780033516 | 903430 | 903430 | The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s effects on the fluid column within the drainage catheter of an implanted shunt system. The GCA consists of a silicone elastomer encased stainless steel housing with a ruby ball held in a stainless steel seat (in the vertical orientation) by two to four stainless steel balls. In the horizontal orientation, a minimal resistance to flow (<30mmH2O at 5ml/h) is added to the system, and in the vertical orientation: 140-170, 200-250 or 260-320mmH2O (at 5ml/h). | JXG | Shunt, central nervous system and components | Gravity Compensating Accessory | |
33 | 10381780037248 | VC1 | VC1 | The Integra NeuroSciences Ventricular Catheter is a 25 cm silicone elastomer tub The Integra NeuroSciences Ventricular Catheter is a 25 cm silicone elastomer tubing with full barium impregnation. Numbered length markers are located 5 and 10 cm from the proximal end. Length marker dots are located at 1 cm increments 3 to 14 cm from the proximal end. The proximal end presents fourty (40) flow holes. The proximal tip is constructed of molded, barium sulfate impregnated silicone to provide smooth, consistent end, which aid catheter placement. A stainless steel stylet and a right angle guide are provided. | JXG | Shunt, central nervous system and components | Straight Ventricular Catheter | |
34 | 10381780033356 | 901411 | 901411 | Connectors are implantable accessories intended to be used with Integra Hydrocep Connectors are implantable accessories intended to be used with Integra Hydrocephalus Valve Systems for connection between an implanted ventricular catheter or drainage catheter and a CSF Shunt System. | JXG | Shunt, central nervous system and components | Stainless Steel Connector | |
35 | 10381780033363 | 901412 | 901412 | Connectors are implantable accessories intended to be used with Integra Hydrocep Connectors are implantable accessories intended to be used with Integra Hydrocephalus Valve Systems for connection between an implanted ventricular catheter or drainage catheter and a CSF Shunt System. | JXG | Shunt, central nervous system and components | Stainless Steel Connector | |
36 | 10381780033370 | 901414 | 901414 | Connectors are implantable accessories intended to be used with Integra Hydrocep Connectors are implantable accessories intended to be used with Integra Hydrocephalus Valve Systems for connection between an implanted ventricular catheter or drainage catheter and a CSF Shunt System. | JXG | Shunt, central nervous system and components | Stainless Steel Connector | |
37 | 10381780033349 | 901410 | 901410 | Connectors are implantable accessories intended to be used with Integra Hydrocep Connectors are implantable accessories intended to be used with Integra Hydrocephalus Valve Systems for connection between an implanted ventricular catheter or drainage catheter and a CSF Shunt System. | JXG | Shunt, central nervous system and components | Stainless Steel Connector | |
38 | 10381780250395 | VTUN | The Camino Flex Ventricular Intracranial Pressure Monitoring Kit is indicated wh The Camino Flex Ventricular Intracranial Pressure Monitoring Kit is indicated when direct and continuous intraventricular intracranial pressure monitoring and cerebrospinal fluid drainage are required. The catheter is embedded with a strain gauge pressure transducer.The system is designed for no more than five days of continuous monitoring. | GWM | DEVICE, MONITORING, INTRACRANIAL PRESSURE | 2 | Camino® | |
39 | 10381780035985 | 9MZ500 | 9MZ500 | The Radiopaque Polypropylene Plug consists of a Tubing Plug provided for surgeon The Radiopaque Polypropylene Plug consists of a Tubing Plug provided for surgeons using the Integral Ventricular Reservoir (IVR) who prefer to use the wire introducer for introduction of the ventricular catheter. The plug allows to close the catheter after its placement. | JXG | Shunt, central nervous system and components | Radiopaque Polypropylene Plug | |
40 | 10381780035602 | 910410B | 910410B | The Integral Drainage Set (IDS) consists of a one-piece assembly (male Luer-lock The Integral Drainage Set (IDS) consists of a one-piece assembly (male Luer-lock connector; small diameter drainage inlet tube with attached clamp, check valve, and silicone band; graduated bag with hydrophobic vent filter, drip chamber, suspension string with adjustable clip; large diameter drainage collector; outlet tube with clamp, watertight cap and silicone band); a 360° three-way stopcock with Luer-lock connectors; two stopcock protection boxes. | JXG | Shunt, central nervous system and components | Integral Drainage Set | |
41 | 10381780035589 | 910123A | 910123A | The External Drainage Set (EDS) consists of: an extension tubing line with a T f The External Drainage Set (EDS) consists of: an extension tubing line with a T fitting and a four-way stopcock; a one-piece drainage tube assembly, including a patient line with a T fitting, a tubing, an antireflux valve, a 75 ml cylinder and a drainage tubing; a drainage bag with female luer lock connector, a suspension hook and a hydrophobic filter; a 350 mm H2O drainage pressure scale. A Ventricular Catheter Accessory Kit (VCAK). A Pressure Transducer. | JXG | Shunt, central nervous system and components | External Drainage Set | |
42 | 10381780035565 | 910120A | 910120A | The External Drainage Set (EDS) consists of: an extension tubing line with a T f The External Drainage Set (EDS) consists of: an extension tubing line with a T fitting and a four-way stopcock; a one-piece drainage tube assembly, including a patient line with a T fitting, a tubing, an antireflux valve, a 75 ml cylinder and a drainage tubing; a drainage bag with female luer lock connector, a suspension hook and a hydrophobic filter; a 350 mm H2O drainage pressure scale. A Lumbar Catheter Accessory Kit (LCAK). | JXG | Shunt, central nervous system and components | External Drainage Set | |
43 | 10381780035558 | 910116D | 910116D | 6 Drainable Collection Bags, 500 ml, with female Luer-lock connector, a suspensi 6 Drainable Collection Bags, 500 ml, with female Luer-lock connector, a suspension hook, and a hydrophobic filter. | JXG | Shunt, central nervous system and components | External Drainage Set | |
44 | 10381780035541 | 910116A | 910116A | Replacement Drainage Bag, 500 ml, with female Luer-lock connector, a suspension Replacement Drainage Bag, 500 ml, with female Luer-lock connector, a suspension hook, and a hydrophobic filter. | JXG | Shunt, central nervous system and components | External Drainage Set | |
45 | 10381780035527 | 910112A | 910112A | The External Drainage Set (EDS) consists of: an extension tubing line with a T f The External Drainage Set (EDS) consists of: an extension tubing line with a T fitting and a four-way stopcock; a one-piece drainage tube assembly, including a patient line with a T fitting, a tubing, an antireflux valve, a 75 ml cylinder and a drainage tubing; a drainage bag with female luer lock connector, a suspension hook and a hydrophobic filter; a 350 mm H2O drainage pressure scale. It also includes a Ventricular Catheter Accessory Kit. | JXG | Shunt, central nervous system and components | External Drainage Set | |
46 | 10381780035503 | 910110A | 910110A | The External Drainage Set (EDS) consists of: an extension tubing line with a T f The External Drainage Set (EDS) consists of: an extension tubing line with a T fitting and a four-way stopcock; a one-piece drainage tube assembly, including a patient line with a T fitting, a tubing, an antireflux valve, a 75 ml cylinder and a drainage tubing; a drainage bag with female luer lock connector, a suspension hook and a hydrophobic filter; a 350 mm H2O drainage pressure scale. | JXG | Shunt, central nervous system and components | External Drainage Set | |
47 | 10381780034612 | 999304 | 999304 | The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a p The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a polypropylene needle-stop, and an F8 integrated connector. The CSF Reservoir can be provided alone. Other configurations include a right angle ventricular catheter (7 cm or 9 cm length) and a 15 cm introducing rod, or a 15 cm straight ventricular catheter and a right angle guide. The ventricular catheter features radiopaque length markings at 2, 4, 6, 8, 10 cm from the tip. | LKG | PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVENTRICULAR | CSF Reservoir | |
48 | 10381780034605 | 999303 | 999303 | The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a p The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a polypropylene needle-stop, and an F8 integrated connector. The CSF Reservoir can be provided alone. Other configurations include a right angle ventricular catheter (7 cm or 9 cm length) and a 15 cm introducing rod, or a 15 cm straight ventricular catheter and a right angle guide. The ventricular catheter features radiopaque length markings at 2, 4, 6, 8, 10 cm from the tip. | LKG | PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVENTRICULAR | CSF Reservoir | |
49 | 10381780034599 | 999302 | 999302 | The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a p The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a polypropylene needle-stop, and an F8 integrated connector. The CSF Reservoir can be provided alone. Other configurations include a right angle ventricular catheter (7 cm or 9 cm length) and a 15 cm introducing rod, or a 15 cm straight ventricular catheter and a right angle guide. The ventricular catheter features radiopaque length markings at 2, 4, 6, 8, 10 cm from the tip. | LKG | PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVENTRICULAR | CSF Reservoir | |
50 | 10381780034582 | 999301 | 999301 | The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a p The CSF Reservoir consists of a silicone dome-shaped reservoir incorporating a polypropylene needle-stop, and an F8 integrated connector. The CSF Reservoir can be provided alone. Other configurations include a right angle ventricular catheter (7 cm or 9 cm length) and a 15 cm introducing rod, or a 15 cm straight ventricular catheter and a right angle guide. The ventricular catheter features radiopaque length markings at 2, 4, 6, 8, 10 cm from the tip. | LKG | PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVENTRICULAR | CSF Reservoir |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 10381780211082 | NL850500V | NL850500V | Integra™ Ventricular Drainage System provides a sterile path for the drainage of Integra™ Ventricular Drainage System provides a sterile path for the drainage of cerebrospinal fluid (CSF) from an intraventricular catheter to a collection bag. The system can be used for external drainage, and the management of hydrocephalic shunt infections, or treatment of other cerebral conditions such as pre-operative or post-operative pressure monitoring of CSF to control increased intracranial pressure. | N/A | INTEGRA LIFESCIENCES CORPORATION |
2 | 10381780112273 | NL79034S02 | NL79034S02 | The silicone elastomer Integra CSF Reservoir, in connection with a ventricular c The silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or CSF. The Convertible model incorporates an outlet tube in addition to an inlet tube. The outlet tube may be connected to a distal catheter, allowing the reservoir to be used in a shunting system, if later indicated. The 2.5cm base diameter reservoir is a flat bottom design; the 1.5cm base diameter reservoir is a burr-hole model. | Dual Outlet Convertible Integra™ Reservoir | INTEGRA LIFESCIENCES CORPORATION |
3 | 10381780112266 | INS410MM | INS410MM | The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. | LimiTorr™ | INTEGRA LIFESCIENCES CORPORATION |
4 | 10381780112259 | INS410CM | INS410CM | The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. | LimiTorr™ | INTEGRA LIFESCIENCES CORPORATION |
5 | 10381780112242 | INS410 | INS410 | The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. | LimiTorr™ | INTEGRA LIFESCIENCES CORPORATION |
6 | 10381780112228 | INS400L | INS400L | The Pole Mount Laser Level device is provided with mounting bracket for use with The Pole Mount Laser Level device is provided with mounting bracket for use with Integra Pole Mount Assemblies. The Pole Mount Laser provides alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular catheter or lumbar catheter to an external ventricular drainage system. | LimiTorr™ | INTEGRA LIFESCIENCES CORPORATION |
7 | 10381780112211 | INS400CM | INS400CM | The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. | LimiTorr™ | INTEGRA LIFESCIENCES CORPORATION |
8 | 10381780112204 | INS400 | INS400 | The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. | LimiTorr™ | INTEGRA LIFESCIENCES CORPORATION |
9 | 10381780112198 | INS310 | INS310 | MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail: The Pole Mount Asse MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail: The Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems (EVD). These systems are used for draining CSF from an intraventricular catheter to the external ventricular drainage system. A Pole Mount Sliding Bracket is supplied with each Pole Mount Assembly. The Pole Mount Sliding Bracket is used to secure the EVD system to the rail on the Pole Mount Assembly. | Integra™ MoniTorr ICP™ Pole Mount Assmbly | INTEGRA LIFESCIENCES CORPORATION |
10 | 10381780112181 | INS305 | INS-305 | The MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail provides support The MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail provides support and alignment for External Ventricular Drainage (EVD) Systems. These systems are used for draining cerebrospinal fluid (CSF) from an intraventricular catheter to the external ventricular drainage system. | Integra™ | INTEGRA LIFESCIENCES CORPORATION |
11 | 10381780112174 | INS301 | INS301 | The Integra Pole Mount Sliding Bracket can be used with Integra External Ventric The Integra Pole Mount Sliding Bracket can be used with Integra External Ventricular Drainage (EVD) systems and may also be used as a replacement assembly or accessory component. The Integra Pole Mount Sliding Bracket is used to secure the EVD system to the rail of the Pole Mount Assembly. | Integra™ Pole Mount Sliding Bracket | INTEGRA LIFESCIENCES CORPORATION |
12 | 10381780112167 | INS300L | INS300L | MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail and Laser Leveling D MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail and Laser Leveling Device: The Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems (EVD). These systems are used for draining CSF from an intraventricular catheter to the external ventricular drainage system. A Pole Mount Sliding Bracket is supplied with each Pole Mount Assembly. The Pole Mount Sliding Bracket is used to secure the EVD system to the rail on the Pole Mount Assembly. | Integra™ MoniTorr ICP™ Pole Mount Assmbly | INTEGRA LIFESCIENCES CORPORATION |
13 | 10381780112143 | INS300 | INS300 | MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg rail: The Pole Mount Asse MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg rail: The Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems (EVD). These systems are used for draining CSF from an intraventricular catheter to the external ventricular drainage system. A Pole Mount Sliding Bracket is supplied with each Pole Mount Assembly. The Pole Mount Sliding Bracket is used to secure the EVD system to the rail on the Pole Mount Assembly. | Integra™ MoniTorr ICP™ Pole Mount Assmbly | INTEGRA LIFESCIENCES CORPORATION |
14 | 10381780112136 | 310991 | 310991 | POLE MOUNT PARTS KIT ASSEMBLYPole Mount Spare Parts Kit | Integra™ Pole Mount Spare Parts Kit | INTEGRA LIFESCIENCES CORPORATION |
15 | 10381780072560 | SP0236 | SP0236 | MONITORR SPECIAL NEEDLE SITEThe MoniTorr ICP External CSF Drainage and Monitorin MONITORR SPECIAL NEEDLE SITEThe MoniTorr ICP External CSF Drainage and Monitoring System provides a simple to use, closed system for the drainage of cerebrospinal fluid (CSF) from ventricles of the brain or the lumbar subarachnoid space to a drainage bag. The system may be used with a pole mounted assembly that allows for simple, quick, and accurate alignment with the patient and secure, positive or negative pressure level setting. The system has also been designed to provide for ease of patient transport through a compact design and an antimicrobial hydrophobic vent feature that resists occlusion. Common features include a calibrated graduated burette, a drainage bag, sampling/aspiration sites, green stripe pressure tubing, and a needle Y injection site. | MoniTorr™ | INTEGRA LIFESCIENCES CORPORATION |
16 | 10381780072553 | SP0224 | SP0224 | LUMBAR CATHETER CLOSED TIPThe 80cm barium impregnated silicone lumbar catheter h LUMBAR CATHETER CLOSED TIPThe 80cm barium impregnated silicone lumbar catheter has a closed radiopaque tip and is supplied with a Teflon coated stainless steel guide wire and end stop for assisting catheter placement. Approximately 18mm of the tip is multi-perforated to help improve flow and decrease the possibility of obstruction. Designed for diverting fluid from the lumbar subarachnoid space, the catheter can be inserted with a Tuohy needle using percutaneous techniques. The external portion of the catheter is secured to the subcutaneous tissue in the lumbar area by the suture collar. A 14-guage thin wall Tuohy needle with obturator, guide wire, and 22-gauge blunt needle are included. A female luer adapter and train relief tubing is also included. Two suture collars may be wrapped around the catheter and may be anchored in place with a suture. | Hermetic™ External Drainage Lumbar Catheter | INTEGRA LIFESCIENCES CORPORATION |
17 | 10381780072546 | NL98003S01 | NL98003S01 | PERITONEAL CATHETER, 90CM LENGTHThe Integra Peritoneal Open-Ended Catheter with PERITONEAL CATHETER, 90CM LENGTHThe Integra Peritoneal Open-Ended Catheter with Slits is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity with minimum flow resistance. This catheter is recommended for use with pressure control valves located proximally in the hydrocephalic shunt system. The catheter is made of a high durometer silicone elastomer which helps resist kinking and occlusion caused by the bending or twisting of the catheter. A stripe, made of barium sulfate impregnated silicone elastomer, is imbedded in the wall of the catheter. The stripe provides a catheter which is radiopaque throughout its entire length, while keeping barium sulfate away from the surface of the catheter and allowing visual observation of flow through the catheter during implantation. Black radiopaque length markers are located at 10, 20, and 30 cm from the distal tip to assist in positioning of the catheter. The catheter is open-ended; it does not resist retrograde flow. This catheter provides flow resistance of approximately 12 mm H2O at a flow rate of 23 ml/hr. | Integra Peritoneal Open-Ended Catheter With Slits | INTEGRA LIFESCIENCES CORPORATION |
18 | 10381780072539 | NL97105S01 | NL97105S01 | LONG SPETZLER 105CM LP SHUNT The Spetzler Lumbar Peritoneal Shunt System is des LONG SPETZLER 105CM LP SHUNT The Spetzler Lumbar Peritoneal Shunt System is designed to shunt cerebrospinal fluid (CSF) from the lumbar subarachnoid space to the peritoneum. Due to the small diameter of the catheter tubing, shunting may be accomplished by percutaneous techniques. A variety of devices are available: a one-piece model without a reservoir; separate large or small reservoirs that contain a one-way valve, which may be used when a flushing capability is required; and a separate miter valve, available in low, medium, or high pressure, which may be used when added resistance is desired. | Integra Spetzler™ Lumbar Peritoneal Shunt System | INTEGRA LIFESCIENCES CORPORATION |
19 | 10381780072522 | NL97003S01 | NL97003S01 | 3 FRENCH T-TUBEThe Integra Edwards-Barbaro Syringo-Peritoneal Shunt is designed 3 FRENCH T-TUBEThe Integra Edwards-Barbaro Syringo-Peritoneal Shunt is designed to provide continuous drainage of fluid from within a spinal cord cyst to a site outside the spinal canal. The T-tube diameter is small to minimize the size of the myelotomy and the catheter is flexible to minimize the spinal cord manipulation necessary to insert the tube into a spinal cord cyst. The T-shape allows drainage above and below the myelotomy site, helps prevent kinking by providing a right-angle exit through the dura, and reduces the risk of migration out of the spinal cord. The multi-holed catheter reduces the risk of clogging at the spinal end of the system. The suture tab allows the T-tube to be anchored to the dura or paraspinous muscles without the risk of shunt occlusion associated with a circumferential ligature. If a step down connector is used, it adapts the T-tube diameter to the peritoneal reflux control catheter. | Integra® | INTEGRA LIFESCIENCES CORPORATION |
20 | 10381780072515 | NL97001S01 | NL97001S01 | STERILE LUER CONNECTOR | N/A | INTEGRA LIFESCIENCES CORPORATION |
21 | 10381780072492 | NL8509851 | NL8509851 | MINI LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to d MINI LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. The kit contains a LPV II valve, mini, a Pudenz Ventricular Catheter and an integral, open-ended kink resistant catheter attached to the outlet of the valve. The kit is available in a medium pressure range. All valves and catheters contain barium sulfate for x-ray detectability. | Integra LPV II Valve Shunt Kit | INTEGRA LIFESCIENCES CORPORATION |
22 | 10381780072485 | NL8509850 | NL8509850 | STANDARD LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed STANDARD LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. The kit contains a LPV II valve, standard, a Pudenz Ventricular Catheter and an integral, open-ended kink resistant catheter attached to the outlet of the valve. The kit is available in a medium pressure range. All valves and catheters contain barium sulfate for x-ray detectability. | Integra LPV II Valve Shunt Kit | INTEGRA LIFESCIENCES CORPORATION |
23 | 10381780072454 | NL8509831 | NL8509831 | MINI LPV II VALVE, HIGHThe Integra LVP II Valve, Mini is a silicone elastomer va MINI LPV II VALVE, HIGHThe Integra LVP II Valve, Mini is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal high pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure. | Integra LPV II Valve | INTEGRA LIFESCIENCES CORPORATION |
24 | 10381780072447 | NL8509821 | NL8509821 | MINI LPV II VALVE, MED.The Integra LVP II Valve, Mini is a silicone elastomer va MINI LPV II VALVE, MED.The Integra LVP II Valve, Mini is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal medium pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure. | Integra LPV II Valve | INTEGRA LIFESCIENCES CORPORATION |
25 | 10381780072430 | NL8509810 | NL8509810 | STANDARD LPV II VALVE, LOWThe Integra LVP II Valve, Standard is a silicone elast STANDARD LPV II VALVE, LOWThe Integra LVP II Valve, Standard is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal low pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure. | Integra LPV II Valve | INTEGRA LIFESCIENCES CORPORATION |
26 | 10381780072423 | NL8508560 | NL8508560 | Large bore tubing assembly with integral one-way valve. | Integra Large Bore Tubing Set | INTEGRA LIFESCIENCES CORPORATION |
27 | 10381780072416 | NL8508430 | NL8508430 | LUMBAR CATHETER WITH GUIDE WIREThe 80cm barium impregnated silicone lumbar cathe LUMBAR CATHETER WITH GUIDE WIREThe 80cm barium impregnated silicone lumbar catheter has a closed tip and is supplied with a Teflon coated stainless steel guide wire and end stop for assisting catheter placement. Approximately 18mm of the tip is multi-perforated to help improve flow and decrease the possibility of obstruction. Four tantalum impregnated length markers are placed on the proximal end of the catheter. Designed for diverting fluid from the lumbar subarachnoid space, the catheter can be inserted with a tuohy needle using percutaneous techniques. The first marker aligns with the opening in the hub of the Touhy needle, after which the markers are spaced at 5cm intervals from the first marker to allow the surgeon to gauge the length of catheter that has been implanted into the lumbar subarachnoid space. The external portion of the catheter is secured to the subcutaneous tissue in the lumbar area by the suture collar. | Hermetic Lumbar Drainage Accessory Kit | INTEGRA LIFESCIENCES CORPORATION |
28 | 10381780072409 | NL8508420 | NL8508420 | TRAUMACATH VENTRICULAR CATHETER SETThe TraumaCath Ventricular Catheter set cathe TRAUMACATH VENTRICULAR CATHETER SETThe TraumaCath Ventricular Catheter set catheter is barium striped. Designed for diverting fluid from the ventricles through a series of drainage holes, the catheter can be inserted into the ventricular cavity with the stainless steel stylet. A trocar is supplied with the catheter to facilitate subcutaneous tunneling away from the burr hole. The external portion of the catheter may be secured to the scalp by the suture tab. The luer lock supplied with each ventricular catheter set will connect the catheter to any Integra external drainage system. | TraumaCath Ventricular Catheter Set | INTEGRA LIFESCIENCES CORPORATION |
29 | 10381780072393 | NL8508330 | NL8508330 | LUMBAR DRAINAGE KITThe 80cm barium impregnated silicone lumbar catheter has an o LUMBAR DRAINAGE KITThe 80cm barium impregnated silicone lumbar catheter has an open tip and is cut at an angle. Approximately 18mm of the tip is multi-perforated to help improve flow and decrease the possibility of obstruction. Four tantalum impregnated length markers are placed on the proximal end of the catheter. Designed for diverting fluid from the lumbar subarachnoid space, the catheter can be inserted with a tuohy needle using percutaneous techniques. The first marker aligns with the opening in the hub of the Touhy needle, after which the markers are spaced at 5cm intervals from the first marker to allow the surgeon to gauge the length of catheter that has been implanted into the lumbar subarachnoid space. The external portion of the catheter is secured to the subcutaneous tissue in the lumbar area by the suture collar. | Hermetic Lumbar Drainage Accessory Kit | INTEGRA LIFESCIENCES CORPORATION |
30 | 10381780072386 | NL8508220 | NL8508220 | HERMETIC VENTRICULAR CATHETER SETThe Hermetic Ventricular Catheter set catheter HERMETIC VENTRICULAR CATHETER SETThe Hermetic Ventricular Catheter set catheter is barium impregnated. Designed for diverting fluid from the ventricles through a series of drainage holes, the catheter can be inserted into the ventricular cavity with the stainless steel stylet. A trocar is supplied with the catheter to facilitate subcutaneous tunneling away from the burr hole. The external portion of the catheter may be secured to the scalp by the suture tab. The luer lock supplied with each ventricular catheter set will connect the catheter to any Integra external drainage system. | Hermetic™ | INTEGRA LIFESCIENCES CORPORATION |
31 | 10381780072355 | NL8501519 | NL8501519 | CATHETER PUDENZ RT ANG. VENT. STRIPEDThe Integra Pudenz Ventricular Catheter is CATHETER PUDENZ RT ANG. VENT. STRIPEDThe Integra Pudenz Ventricular Catheter is designed for shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion caused by the bending or twisting of the catheter. A stripe, made of barium sulfate impregnated silicone elastomer is imbedded in the wall of the catheter. The stripe provides a catheter which is radiopaque throughout its entire length, while keeping barium sulfate away from the surface of the catheter and allowing visual observation of flow through the catheter during implantation. The right-angle model is formed with a right-angle bend .The right-angle bend of this model allows the use of a straight, rather than a right-angle, connector to fasten the catheter to a flat-bottom flushing device. A black, radiopaque marker is located at the right-angle bend to allow the surgeon to easily identify the location of the bend during implantation with a stylet. | Integra Pudenz Ventricular Catheter | INTEGRA LIFESCIENCES CORPORATION |
32 | 10381780072348 | NL8501504 | NL8501504 | The Pudenz Ventricular Catheter is designed for shunting CSF from the ventricles The Pudenz Ventricular Catheter is designed for shunting CSF from the ventricles of the brain. The Graduated Small Model has a slightly smaller outside diameter, and is made of a lower durometer (softer) silicone elastomer. | Integra Pudenz Ventricular Catheter | INTEGRA LIFESCIENCES CORPORATION |
33 | 10381780072331 | NL8501382 | NL8501382 | CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is d CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system closing pressure. It also serves to help resist retrograde flow of fluids into the distal end of the catheter. The closing pressure range is high, which is 95-150 mm of H2O. The graduated model of the Pudenz Peritoneal Catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion. The tip of the catheter contains a radiopaque tantalum impregnated, silicone elastomer plug to aid in determining location during and subsequent to implantation. The catheter displays radiopaque markers to allow the surgeon to measure the length of tubing placed within the body during surgery. | Integra Pudenz Peritoneal Catheter | INTEGRA LIFESCIENCES CORPORATION |
34 | 10381780072324 | NL8501381 | NL8501381 | CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is d CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system closing pressure. It also serves to help resist retrograde flow of fluids into the distal end of the catheter. The closing pressure range is medium, which is 55-94 mm of H2O. The graduated model of the Pudenz Peritoneal Catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion. The tip of the catheter contains a radiopaque tantalum impregnated, silicone elastomer plug to aid in determining location during and subsequent to implantation. The catheter displays radiopaque markers to allow the surgeon to measure the length of tubing placed within the body during surgery. | Integra Pudenz Peritoneal Catheter | INTEGRA LIFESCIENCES CORPORATION |
35 | 10381780072317 | NL8501380 | NL8501380 | CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is d CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system closing pressure. It also serves to help resist retrograde flow of fluids into the distal end of the catheter. The closing pressure range is low, which is 15-54 mm of H2O. The graduated model of the Pudenz Peritoneal Catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion. The tip of the catheter contains a radiopaque tantalum impregnated, silicone elastomer plug to aid in determining location during and subsequent to implantation. The catheter displays radiopaque markers to allow the surgeon to measure the length of tubing placed within the body during surgery. | Integra Pudenz Peritoneal Catheter | INTEGRA LIFESCIENCES CORPORATION |
36 | 10381780072300 | NL8501328 | NL8501328 | NEUROVIEW ENDOSCOPIC VENT CATHThe Integra Neuroview ventricular catheter is desi NEUROVIEW ENDOSCOPIC VENT CATHThe Integra Neuroview ventricular catheter is designed to be used with a neurosurgical endoscope. The endoscope is used when a physician wishes to place a catheter’s tip at a specific intraventricular location or to view intraventricular anatomy. The slit-tip of the catheter protects the endocscope from debris buildup during insertion, but allows intraventricular viewing to assist in optimal catheter placement. The Neuroview ventricular catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion caused by the bending or twisting of the catheter. A stripe, made of barium sulfate impregnated silicone elastomer, is imbedded in the wall of the catheter. The stripe provides a catheter which is radiopaque throughout its entire length, while keeping barium sulfate away from the surface of the catheter and allowing visual observation of flow through the catheter during implantation. The catheter has multiple small perforations near the tip to facilitate drainage of CSF and to help reduce clogging. The extreme tip is closed to help prevent particulate matter from entering the tubing during insertion. The catheter has graduation markers to allow the surgeon to measure the length of tubing placed within the ventricle during surgery. | Integra Neuroview Endoscopic Ventricular Catheter | INTEGRA LIFESCIENCES CORPORATION |
37 | 10381780072294 | NL8501222 | NL8501222 | The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of C The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of CSF in children with small veins. The distal section of the catheter is reduced to approximately one-half standard diameter for easier insertion. The proximal section of the catheter contains an imbedded barium sulfate-impregnated strip, and the distal section is fully barium sulfate-impregnated. The infant model does not contain graduation markets. | Integra Pudenz Infant Cardiac Catheter | INTEGRA LIFESCIENCES CORPORATION |
38 | 10381780072287 | NL8501221 | NL8501221 | The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of C The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of CSF in children with small veins. The distal section of the catheter is reduced to approximately one-half standard diameter for easier insertion. The proximal section of the catheter contains an imbedded barium sulfate-impregnated strip, and the distal section is fully barium sulfate-impregnated. The infant model does not contain graduation markets. | Integra Pudenz Infant Cardiac Catheter | INTEGRA LIFESCIENCES CORPORATION |
39 | 10381780072270 | NL8501202 | NL8501202 | The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the right atrium of the heart through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system pressure. It also serves to resist retrograde flow of fluids into the distal end of the catheter. This standard model has a high closing pressure range (95-150 mm H2O). | Integra Pudenz Cardiac Catheter | INTEGRA LIFESCIENCES CORPORATION |
40 | 10381780072263 | NL8501200 | NL8501200 | The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the right atrium of the heart through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system pressure. It also serves to resist retrograde flow of fluids into the distal end of the catheter. This standard model has a medium closing pressure range (55-94 mm H2O). | Integra Pudenz Cardiac Catheter | INTEGRA LIFESCIENCES CORPORATION |
41 | 10381780072256 | NL8500312 | NL8500312 | VALVE FLUSH F/B D/C W/CONNECTORThe Integra Mishler Dual Chamber Flushing valve, VALVE FLUSH F/B D/C W/CONNECTORThe Integra Mishler Dual Chamber Flushing valve, Flat Bottom Design incorporates two separate interior chambers to provide two-way flow control when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. This silicone elastomer flushing valve is available with or without an integral Anti-Siphon Device. The flat bottom configuration eliminates the need for a formal burr hole, provides greater latitude in positioning the flushing valve and allows the ventricular catheter to be revised without disturbing the flushing valve. Due to the dual chamber feature, the proximal and distal catheters may be flushed separately or simultaneously. The flow of CSF from the ventricular catheter is controlled by a miter valve located on the vertical chamber divider. This valve is designed to open under a medium positive ventricular pressure and close under a negative pressure. The flushing valve dome is marked with an arrow to indicate the CSF flow direction. The flange overlying the skull contains sutural holes to facilitate securing the device to the periosteum. | Integra Mishler Dual Chamber Flushing Valve | INTEGRA LIFESCIENCES CORPORATION |
42 | 10381780072249 | NL83026S04 | NL83026S04 | MINI INTEGRA FLAT BOTTOMThe silicone elastomer Integra CSF Reservoir, in connect MINI INTEGRA FLAT BOTTOMThe silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or cerebrospinal fluid (CSF). Access is obtained by penetrating the reservoir dome with a 25-gauge or smaller needle. In this manner, CSF may be withdrawn or other fluid injected into the reservoir. The mini, dual side inlet reservoir’s inlet tubing enters from the sides of the reservoir rather than from the base. This flat bottom dual side inlet design eliminates the need for a formal burr hole, provides greater latitude in positioning and allows the ventricular catheter to be revised without disturbing the reservoir. | Integra™ CSF Reservoir | INTEGRA LIFESCIENCES CORPORATION |
43 | 10381780072232 | NL83026S03 | NL83026S03 | MINI INTEGRA CSF RES. CONV MODThe silicone elastomer Integra CSF Reservoir, in c MINI INTEGRA CSF RES. CONV MODThe silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or cerebrospinal fluid (CSF). Access is obtained by penetrating the reservoir dome with a 25-gauge or smaller needle. In this manner, CSF may be withdrawn or other fluid injected into the reservoir. The mini convertible model incorporates an outlet tube in addition to an inlet tube. The outlet tube may be connected to a distal catheter, allowing the reservoir to be used in a shunting system. Since the distal tip of the outlet tube is plugged, conversion to a shunting system requires cutting off the outlet tube proximal to the plugged end for connection to a distal shunt catheter. This model is a flat bottom design. This mini model is not provided with a ventricular catheter and stylet. | Integra™ CSF Reservoir | INTEGRA LIFESCIENCES CORPORATION |
44 | 10381780072225 | NL83026S02 | NL83026S02 | MINI INTEGRA CSF RES. SIDEThe silicone elastomer Integra CSF Reservoir, in conne MINI INTEGRA CSF RES. SIDEThe silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or cerebrospinal fluid (CSF). Access is obtained by penetrating the reservoir dome with a 25-gauge or smaller needle. In this manner, CSF may be withdrawn or other fluid injected into the reservoir. The mini, side inlet reservoir’s inlet tubing enters from the sides of the reservoir rather than from the base. This flat bottom side inlet design eliminates the need for a formal burr hole, provides greater latitude in positioning and allows the ventricular catheter to be revised without disturbing the reservoir. | Integra™ CSF Reservoir | INTEGRA LIFESCIENCES CORPORATION |
45 | 10381780072218 | NL83026S01 | NL83026S01 | MINI INTEGRA CSF STD. MOD.The silicone elastomer Integra CSF Reservoir, in conne MINI INTEGRA CSF STD. MOD.The silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or cerebrospinal fluid (CSF). Access is obtained by penetrating the reservoir dome with a 25-gauge or smaller needle. In this manner, CSF may be withdrawn or other fluid injected into the reservoir. The standard model consists of a single flushing reservoir, supplied with a separate ventricular catheter. The reservoir is designed for subcutaneous placement and attached to the ventricular catheter at the straight connector. The reservoir is made with a suture flange at its base for attachment to the periosteum. This mini-standard model is a flat bottom device requiring only a small burr hole opening to accommodate the inlet tubing on the base of the reservoir. | Integra™ CSF Reservoir | INTEGRA LIFESCIENCES CORPORATION |
46 | 10381780072201 | NL83024S01 | NL83024S01 | Integra CSF Ventricular Catheter Guide | Integra CSF ventricular catheter guide | INTEGRA LIFESCIENCES CORPORATION |
47 | 10381780072195 | NL82059S03 | NL82059S03 | TUOHY NEEDLE 14g 6" for Lumbar Peritoneal ShuntA 6-inch, 14-gauge Tuohy needle TUOHY NEEDLE 14g 6" for Lumbar Peritoneal ShuntA 6-inch, 14-gauge Tuohy needle used for inserting the lumbar catheter end into the subarachnoid space. | Integra Spetzler™ Lumbar Peritoneal Shunt System | INTEGRA LIFESCIENCES CORPORATION |
48 | 10381780072171 | INS8902 | INS8902 | ACCUDRAIN LASERThe AccuDrain Laser Level device is provided with a mounting brac ACCUDRAIN LASERThe AccuDrain Laser Level device is provided with a mounting bracket for use with Integra AccuDrain external CSF drainage systems. The AccuDrain Laser Level is an alignment tool for the AccuDrain drainage system. AccuDrain drainage systems are used for draining cerebrospinal fluid from an intraventricular catheter or lumbar catheter to an external drainage system. | AccuDrain® | INTEGRA LIFESCIENCES CORPORATION |
49 | 10381780072164 | INS8601 | INS8601 | POLE MOUNT, PRESS. MONIT. SYS.The External CSF Drainage Systems provide a steril POLE MOUNT, PRESS. MONIT. SYS.The External CSF Drainage Systems provide a sterile fluid path resistant to microbial particles. The systems are used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, fluid injection, CSF sampling and intracranial pressure monitoring. Common features include a calibrated 50 ml graduated burette, 700 ml drainage bag, anti-microbial hydrophobic vent, needleless sampling/aspiration sites and pressure monitoring green stribed tubing. | Hermetic™ External CSF Drainage System | INTEGRA LIFESCIENCES CORPORATION |
50 | 10381780072157 | 10212 | 10212 | Sterile latex free MoniTorr ICP Drainage Bag | MoniTorr ICP™ Drainage Bag | INTEGRA LIFESCIENCES CORPORATION |