Other products from "VENNER MEDICAL (SINGAPORE) PTE. LTD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08885009190820 902170 902170 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
2 08885009190844 902190 902190 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
3 08885009190257 702120 702120 The laryngoscope with a MIL Blade size 2 attached is used to assist routine endo The laryngoscope with a MIL Blade size 2 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 2 Blade (clean, non-sterile)
4 18885009190216 701011 701011 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ VL
5 08885009190226 702910 702910 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module (Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(S)
6 08885009190059 701000 701000 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy and endotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Video Viewer and Charger
7 08885009190806 902080 902080 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
8 08885009190813 902090 902090 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
9 08885009190790 902070 902070 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
10 18885009190209 701010 701010 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ DL
11 08885009190707 903200 903200 An electro-mechanical system for the control of air pressure within the inflatio An electro-mechanical system for the control of air pressure within the inflation cuff of an Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy tube. BSK Cuff, Tracheal Tube, Inflatable Venner™ Tracheal Seal Monitor
12 08885009190745 901090 901090 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
13 08885009190738 901080 901080 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
14 08885009190721 901070 901070 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
15 08885009190042 700170 700170 The DAB Blades is used with the video laryngoscope to assist endotracheal intuba The DAB Blades is used with the video laryngoscope to assist endotracheal intubations for difficult airways. CCW Laryngoscope, Rigid 1 APA™ DAB (clean, non-sterile)
16 08885009190851 903001 903001 For facilitating the cuff inflation connection between the Venner™ Tracheal Seal For facilitating the cuff inflation connection between the Venner™ Tracheal Seal Monitor and Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner™ Tracheal Seal Monitor Extension Tube
17 08885009190783 901190 901190 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
18 08885009190776 901180 901180 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
19 08885009190769 901170 901170 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
20 08885009190752 901160 901160 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
21 08885009190325 700330 700330 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 3 Blade
22 08885009190240 702110 702110 The laryngoscope with a MIL Blade size 1 attached is used to assist routine endo The laryngoscope with a MIL Blade size 1 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 1 Blade (clean, non-sterile)
23 08885009190332 700340 700340 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 4 Blade
24 08885009190905 903010 903010 For facilitating the cuff inflation connection between the Venner PneuX TSM™ and For facilitating the cuff inflation connection between the Venner PneuX TSM™ and an Venner PneuX™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner PneuX TSM™ Extension Tube(non-sterile)
25 08885009190356 700380 700380 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 U-DAB
26 08885009190349 700370 700370 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. CCW,BYX Laryngoscope, Rigid,Tubing, Pressure And Accessories 1 APA™ O2 DAB
27 08885009190035 700140 700140 The laryngoscope with the MAC Blade size 4 attached is used to assist routine en The laryngoscope with the MAC Blade size 4 attached is used to assist routine endotracheal intubation in a similar manner to a standard Macintosh laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MAC 4 Blade (clean, non-sterile)
28 08885009190073 700930 700930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MAC Camera Module
29 08885009190233 702930 702930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module(Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(L)
30 08885009190196 701009 701009 A long stiffening wire/rod designed for insertion within the lumen of an artific A long stiffening wire/rod designed for insertion within the lumen of an artificial airway tube (e.g. endotracheal tube) to stiffen and/or maintain the shape of the tube to facilitate introduction (intubation). BSR Stylet, Tracheal Tube 1 APA™ Stylet
31 08885009190714 901060 901060 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
32 08885009190080 701006 701006 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Handle
33 08885009190066 700180 700180 The U-DAB Blades are used with the video laryngoscope to assist endotracheal int The U-DAB Blades are used with the video laryngoscope to assist endotracheal intubations for difficult airways. CCW Laryngoscope, Rigid 1 APA™ U-DAB (clean, non-sterile)
34 08885009190028 700130 700130 The laryngoscope with the MAC Blade size 3 attached is used to assist routine en The laryngoscope with the MAC Blade size 3 attached is used to assist routine endotracheal intubation in a similar manner to a standard Macintosh laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MAC 3 Blade (clean, non-sterile)
Other products with the same Product Code "BTO"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 B181C9HF20 C-9HF-2 C-9HF-2 Transtracheal Catheters and Cleaning Rods (Two Pack) 9cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
2 B181C920 C-9-2 C-9-2 Transtracheal Catheters and Cleaning Rods (Two Pack) 9cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
3 B181C90 C-9 C-9 Transtracheal Catheter and Cleaning Rod (Single Pack) 9cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
4 B181C13HF20 C-13HF-2 C-13HF-2 Transtracheal Catheters and Cleaning Rods (Two Pack) 13cm length SCOOP TRANSTRACHEAL SYSTEMS, INC.
5 B181C1320 C-13-2 C-13-2 Transtracheal Catheters and Cleaning Rods (Two Pack) 13cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
6 B181C130 C-13 C-13 Transtracheal Catheters and Cleaning Rods (Single Pack) 13cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
7 B181C11HF20 C-11HF-2 C-11HF-2 Transtracheal Catheters and Cleaning Rods (Two Pack) 11cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
8 B181C1120 C-11-2 C-11-2 Transtracheal Catheters and Cleaning Rods (Two Pack) 11cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
9 B181C110 C-11 C-11 Transtracheal Catheter and Cleaning Rod (Single Pack) 11cm SCOOP TRANSTRACHEAL SYSTEMS, INC.
10 B150302964 30296 100ML STERILE SALINE SCREW TOP ORION NURSE ASSIST, INC.
11 B150302954 30295 100ML STERILE WATER SCREW TOP ORION NURSE ASSIST, INC.
12 60884522005321 8DIC Inner Cannula,Disposable Shiley COVIDIEN LP
13 60884522005284 6DIC Inner Cannula,Disposable Shiley COVIDIEN LP
14 60884522005246 4DIC Inner Cannula,Disposable Shiley COVIDIEN LP
15 60884522005208 10DIC Inner Cannula,Disposable Shiley COVIDIEN LP
16 55019315045514 100/856/100 Portex SMITHS MEDICAL INTERNATIONAL LTD
17 50884522007724 SSV Speaking Valve Shiley COVIDIEN LP
18 50351688041164 526100 Portex SMITHS MEDICAL INTERNATIONAL LTD
19 40884522007734 SSVO Speaking Valve,O2 Port Shiley COVIDIEN LP
20 40884522005372 SSVO Speaking Valve,O2 Port Shiley COVIDIEN LP
21 40884522005365 SSV Speaking Valve Shiley COVIDIEN LP
22 40884522005310 8DCP Decannulation Plug Shiley COVIDIEN LP
23 40884522005273 6DCP Decannulation Plug Shiley COVIDIEN LP
24 40884522005235 4DCP Decannulation Plug Shiley COVIDIEN LP
25 40884522005198 10DCP Decannulation Plug Shiley COVIDIEN LP
26 40884522004061 DDCP Decannulation Plug,Disposable Shiley COVIDIEN LP
27 35021312009952 BV1436 Bivona SMITHS MEDICAL ASD, INC.
28 35021312009921 BV1255 Bivona SMITHS MEDICAL ASD, INC.
29 35021312009914 BV1236 Bivona SMITHS MEDICAL ASD, INC.
30 35021312009907 BV1227 Bivona SMITHS MEDICAL ASD, INC.
31 35021312009884 BV1055 Bivona SMITHS MEDICAL ASD, INC.
32 35021312009877 BV1036 Bivona SMITHS MEDICAL ASD, INC.
33 35021312009860 BV1027 Bivona SMITHS MEDICAL ASD, INC.
34 35021312009853 BV1018 Bivona SMITHS MEDICAL ASD, INC.
35 35021312009839 BV0955 Bivona SMITHS MEDICAL ASD, INC.
36 35021312009822 BV0936 Bivona SMITHS MEDICAL ASD, INC.
37 35021312009815 BV0927 Bivona SMITHS MEDICAL ASD, INC.
38 35021312009808 BV0918 Bivona SMITHS MEDICAL ASD, INC.
39 35021312009792 BV0855 Bivona SMITHS MEDICAL ASD, INC.
40 35021312009785 BV0836 Bivona SMITHS MEDICAL ASD, INC.
41 35021312009778 BV0827 Bivona SMITHS MEDICAL ASD, INC.
42 35021312009761 BV0818 Bivona SMITHS MEDICAL ASD, INC.
43 34026704534839 IPN008370 518908 CLJ TRACHEA TUBE #9 EXTRA LONG PILLING TELEFLEX INCORPORATED
44 34026704534822 IPN008369 518906 CLJ TRACHEA TUBE #8 EXTRA LONG PILLING TELEFLEX INCORPORATED
45 34026704534815 IPN008368 518904 CLJ TRACHEA TUBE #7 EXTRA LONG PILLING TELEFLEX INCORPORATED
46 34026704534808 IPN008367 518902 CLJ TRACHEA TUBE #6 EXTRA LONG PILLING TELEFLEX INCORPORATED
47 34026704534792 IPN008366 518900 CLJ TRACHEA TUBE #5 EXTRA LONG PILLING TELEFLEX INCORPORATED
48 34026704534785 IPN008365 518730 CJ TRACHEA TUBE #6 SHORT W/15 MILLIMETER ADAPTOR PILLING TELEFLEX INCORPORATED
49 34026704534778 IPN008364 518720 CJ TRACHEA TUBE #4 SHORT W/15 MILLIMETER ADAPTOR PILLING TELEFLEX INCORPORATED
50 34026704534761 IPN008362 518640 CLJ TRACHEA TUBE #8 SHORT W/15 MILLIMETER ADAPTOR PILLING TELEFLEX INCORPORATED