Other products from "VENNER MEDICAL (SINGAPORE) PTE. LTD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08885009190844 902190 902190 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
2 08885009190837 902180 902180 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
3 08885009190257 702120 702120 The laryngoscope with a MIL Blade size 2 attached is used to assist routine endo The laryngoscope with a MIL Blade size 2 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 2 Blade (clean, non-sterile)
4 18885009190216 701011 701011 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ VL
5 08885009190226 702910 702910 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module (Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(S)
6 08885009190059 701000 701000 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy and endotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Video Viewer and Charger
7 08885009190806 902080 902080 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
8 08885009190813 902090 902090 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
9 08885009190790 902070 902070 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
10 18885009190209 701010 701010 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ DL
11 08885009190707 903200 903200 An electro-mechanical system for the control of air pressure within the inflatio An electro-mechanical system for the control of air pressure within the inflation cuff of an Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy tube. BSK Cuff, Tracheal Tube, Inflatable Venner™ Tracheal Seal Monitor
12 08885009190745 901090 901090 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
13 08885009190738 901080 901080 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
14 08885009190721 901070 901070 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
15 08885009190042 700170 700170 The DAB Blades is used with the video laryngoscope to assist endotracheal intuba The DAB Blades is used with the video laryngoscope to assist endotracheal intubations for difficult airways. CCW Laryngoscope, Rigid 1 APA™ DAB (clean, non-sterile)
16 08885009190851 903001 903001 For facilitating the cuff inflation connection between the Venner™ Tracheal Seal For facilitating the cuff inflation connection between the Venner™ Tracheal Seal Monitor and Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner™ Tracheal Seal Monitor Extension Tube
17 08885009190783 901190 901190 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
18 08885009190776 901180 901180 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
19 08885009190769 901170 901170 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
20 08885009190752 901160 901160 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
21 08885009190325 700330 700330 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 3 Blade
22 08885009190240 702110 702110 The laryngoscope with a MIL Blade size 1 attached is used to assist routine endo The laryngoscope with a MIL Blade size 1 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 1 Blade (clean, non-sterile)
23 08885009190332 700340 700340 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 4 Blade
24 08885009190905 903010 903010 For facilitating the cuff inflation connection between the Venner PneuX TSM™ and For facilitating the cuff inflation connection between the Venner PneuX TSM™ and an Venner PneuX™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner PneuX TSM™ Extension Tube(non-sterile)
25 08885009190356 700380 700380 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 U-DAB
26 08885009190349 700370 700370 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. CCW,BYX Laryngoscope, Rigid,Tubing, Pressure And Accessories 1 APA™ O2 DAB
27 08885009190035 700140 700140 The laryngoscope with the MAC Blade size 4 attached is used to assist routine en The laryngoscope with the MAC Blade size 4 attached is used to assist routine endotracheal intubation in a similar manner to a standard Macintosh laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MAC 4 Blade (clean, non-sterile)
28 08885009190073 700930 700930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MAC Camera Module
29 08885009190233 702930 702930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module(Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(L)
30 08885009190196 701009 701009 A long stiffening wire/rod designed for insertion within the lumen of an artific A long stiffening wire/rod designed for insertion within the lumen of an artificial airway tube (e.g. endotracheal tube) to stiffen and/or maintain the shape of the tube to facilitate introduction (intubation). BSR Stylet, Tracheal Tube 1 APA™ Stylet
31 08885009190714 901060 901060 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
32 08885009190080 701006 701006 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Handle
33 08885009190066 700180 700180 The U-DAB Blades are used with the video laryngoscope to assist endotracheal int The U-DAB Blades are used with the video laryngoscope to assist endotracheal intubations for difficult airways. CCW Laryngoscope, Rigid 1 APA™ U-DAB (clean, non-sterile)
34 08885009190028 700130 700130 The laryngoscope with the MAC Blade size 3 attached is used to assist routine en The laryngoscope with the MAC Blade size 3 attached is used to assist routine endotracheal intubation in a similar manner to a standard Macintosh laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MAC 3 Blade (clean, non-sterile)
Other products with the same Product Code "BTO"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00815347023434 LRV-4015-S Hood Speaking Valve Hood Speaking Valve HOOD, E BENSON LABORATORIES INC
2 00815347023427 LRV-4013-S Hood Speaking Valve Hood Speaking Valve HOOD, E BENSON LABORATORIES INC
3 00815347023410 LRV-4011-S Hood Speaking Valve Hood Speaking Valve HOOD, E BENSON LABORATORIES INC
4 00815347023403 LRV-4008-S Hood Speaking Valve Hood Speaking Valve HOOD, E BENSON LABORATORIES INC
5 00815347023212 SSW-1550 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
6 00815347023205 SSW-1540 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
7 00815347023199 SSW-1530 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
8 00815347023182 SSW-1324 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
9 00815347023175 SSW-1322 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
10 00815347023168 SSW-1319 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
11 00815347023151 SSW-1127 Hood Tracheal Stoma Stent Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
12 00815347023144 SSW-1124 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
13 00815347023137 SSW-1122 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
14 00815347023120 SSW-1119 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
15 00815347023113 SSW-1113 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
16 00815347023106 SSW-1111 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
17 00815347023090 SSW-0823 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
18 00815347023083 SSW-0821 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
19 00815347023076 SSW-0819 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
20 00815347023069 SSW-0817 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
21 00815347023052 SSW-0815 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
22 00815347023045 SSW-0813 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
23 00815347023038 SSW-0811 Hood Tracheal Stoma Button Straight Stoma Stent with Windows HOOD, E BENSON LABORATORIES INC
24 00815347023021 CS-0213 Hood Tracheal Stoma Button Curved Stoma Stent Set HOOD, E BENSON LABORATORIES INC
25 00815347023014 CS-1324 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
26 00815347023007 CS-1322 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
27 00815347022994 CS-1319 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
28 00815347022987 CS-0411 Hood Tracheal Stoma Button Curved Stoma Stent Set HOOD, E BENSON LABORATORIES INC
29 00815347022970 CS-1127 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
30 00815347022963 CS-1124 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
31 00815347022956 CS-1122 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
32 00815347022949 CS-1119 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
33 00815347022932 SS-1115 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
34 00815347022925 CS-1113 Hood Tracheal Stoma Button Curved Stoma Stent HOOD, E BENSON LABORATORIES INC
35 00815347022918 SS-1550 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
36 00815347022901 SS-1540 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
37 00815347022895 SS-1530 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
38 00815347022888 SS-0213 Hood Tracheal Stoma Button Straight Stoma Stent Set HOOD, E BENSON LABORATORIES INC
39 00815347022871 SS-1324 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
40 00815347022864 SS-1322 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
41 00815347022857 SS-1319 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
42 00815347022840 SS-0411 Hood Tracheal Stoma Button Straight Stoma Stent Set HOOD, E BENSON LABORATORIES INC
43 00815347022833 SS-1127 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
44 00815347022826 SS-1124 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
45 00815347022819 SS-1122 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
46 00815347022802 SS-1119 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
47 00815347022796 SS-1113 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
48 00815347022789 SS-1111 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
49 00815347022772 SS-0823 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC
50 00815347022765 SS-0821 Hood Tracheal Stoma Button Straight Stoma Stent HOOD, E BENSON LABORATORIES INC