Other products from "VENNER MEDICAL (SINGAPORE) PTE. LTD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08885009190820 902170 902170 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
2 08885009190844 902190 902190 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
3 08885009190837 902180 902180 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
4 08885009190257 702120 702120 The laryngoscope with a MIL Blade size 2 attached is used to assist routine endo The laryngoscope with a MIL Blade size 2 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 2 Blade (clean, non-sterile)
5 18885009190216 701011 701011 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ VL
6 08885009190226 702910 702910 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module (Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(S)
7 08885009190059 701000 701000 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy and endotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Video Viewer and Charger
8 08885009190806 902080 902080 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
9 08885009190813 902090 902090 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
10 08885009190790 902070 902070 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
11 18885009190209 701010 701010 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ DL
12 08885009190707 903200 903200 An electro-mechanical system for the control of air pressure within the inflatio An electro-mechanical system for the control of air pressure within the inflation cuff of an Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy tube. BSK Cuff, Tracheal Tube, Inflatable Venner™ Tracheal Seal Monitor
13 08885009190745 901090 901090 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
14 08885009190738 901080 901080 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
15 08885009190721 901070 901070 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
16 08885009190042 700170 700170 The DAB Blades is used with the video laryngoscope to assist endotracheal intuba The DAB Blades is used with the video laryngoscope to assist endotracheal intubations for difficult airways. CCW Laryngoscope, Rigid 1 APA™ DAB (clean, non-sterile)
17 08885009190851 903001 903001 For facilitating the cuff inflation connection between the Venner™ Tracheal Seal For facilitating the cuff inflation connection between the Venner™ Tracheal Seal Monitor and Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner™ Tracheal Seal Monitor Extension Tube
18 08885009190783 901190 901190 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
19 08885009190776 901180 901180 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
20 08885009190769 901170 901170 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
21 08885009190752 901160 901160 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
22 08885009190325 700330 700330 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 3 Blade
23 08885009190240 702110 702110 The laryngoscope with a MIL Blade size 1 attached is used to assist routine endo The laryngoscope with a MIL Blade size 1 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 1 Blade (clean, non-sterile)
24 08885009190332 700340 700340 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 4 Blade
25 08885009190905 903010 903010 For facilitating the cuff inflation connection between the Venner PneuX TSM™ and For facilitating the cuff inflation connection between the Venner PneuX TSM™ and an Venner PneuX™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner PneuX TSM™ Extension Tube(non-sterile)
26 08885009190356 700380 700380 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 U-DAB
27 08885009190349 700370 700370 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. CCW,BYX Laryngoscope, Rigid,Tubing, Pressure And Accessories 1 APA™ O2 DAB
28 08885009190035 700140 700140 The laryngoscope with the MAC Blade size 4 attached is used to assist routine en The laryngoscope with the MAC Blade size 4 attached is used to assist routine endotracheal intubation in a similar manner to a standard Macintosh laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MAC 4 Blade (clean, non-sterile)
29 08885009190073 700930 700930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MAC Camera Module
30 08885009190233 702930 702930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module(Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(L)
31 08885009190196 701009 701009 A long stiffening wire/rod designed for insertion within the lumen of an artific A long stiffening wire/rod designed for insertion within the lumen of an artificial airway tube (e.g. endotracheal tube) to stiffen and/or maintain the shape of the tube to facilitate introduction (intubation). BSR Stylet, Tracheal Tube 1 APA™ Stylet
32 08885009190714 901060 901060 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
33 08885009190080 701006 701006 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Handle
34 08885009190028 700130 700130 The laryngoscope with the MAC Blade size 3 attached is used to assist routine en The laryngoscope with the MAC Blade size 3 attached is used to assist routine endotracheal intubation in a similar manner to a standard Macintosh laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MAC 3 Blade (clean, non-sterile)
Other products with the same Product Code "CCW"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04048551409558 8403XSP C-MAC® S Pediatric Imager C-MAC KARL STORZ GMBH & CO. KG
2 04048551409381 10331BX C-MAC® VS C-MAC KARL STORZ GMBH & CO. KG
3 04048551408469 10331BAX C-MAC VS, Tube Holder for ETT C-MAC KARL STORZ GMBH & CO. KG
4 04048551408315 8403XSI C-MAC S Imager C-MAC KARL STORZ GMBH & CO. KG
5 04048551401477 8403MXC C-MAC® Video Laryngoscope MIL #2 C-MAC KARL STORZ GMBH & CO. KG
6 04048551398562 8403EXC C-MAC® Video Laryngoscope MAC #0 C-MAC KARL STORZ GMBH & CO. KG
7 04048551396193 8403GXC C-MAC Video Laryngoscope MIL #1 C-MAC KARL STORZ GMBH & CO. KG
8 04048551396049 8403XDP Connecting Cable n.a. KARL STORZ GMBH & CO. KG
9 04048551396025 8403DXC C-MAC Video Laryngoscope MIL #0 C-MAC KARL STORZ GMBH & CO. KG
10 04048551389539 8403KXC C-MAC Video Laryngoscope MAC #2 C-MAC KARL STORZ GMBH & CO. KG
11 04048551389478 8403AXC C-MAC Video Laryngoscope MAC #3 C-MAC KARL STORZ GMBH & CO. KG
12 04048551389461 8403BX C-MAC Video Laryngoscope MAC #4 C-MAC KARL STORZ GMBH & CO. KG
13 04048551389454 8403BXC C-MAC Video Laryngoscope MAC #4 C-MAC KARL STORZ GMBH & CO. KG
14 04048551389447 8403HX C-MAC Video Laryngoscope D-BLADE C-MAC KARL STORZ GMBH & CO. KG
15 04048551389430 8403AX C-MAC Video Laryngoscope MAC #3 C-MAC KARL STORZ GMBH & CO. KG
16 04048551389423 8403HXP C-MAC Video Laryngoscope D-BLADE, Ped. C-MAC KARL STORZ GMBH & CO. KG
17 04048551389225 8403X C-MAC Connecting Cable C-MAC KARL STORZ GMBH & CO. KG
18 04048551384794 8403XS C-MAC® S Imager C-MAC KARL STORZ GMBH & CO. KG
19 04048551375846 8512ASF LARYNGOBLOC, MACINTOSH #4 n.a. KARL STORZ GMBH & CO. KG
20 04048551375839 8512BSF Laryngobloc® MACINTOSH, #3, short n.a. KARL STORZ GMBH & CO. KG
21 04048551375822 8512AF Laryngobloc® MACINTOSH, #4 n.a. KARL STORZ GMBH & CO. KG
22 04048551375808 8512BF Laryngobloc® MACINTOSH, #3 n.a. KARL STORZ GMBH & CO. KG
23 04048551373644 8401DS C-MAC® GUIDE C-MAC / dBLADE KARL STORZ GMBH & CO. KG
24 04048551365472 8403XA Extension Cable C-HUB® II/C-MAC® C-MAC / C-HUB KARL STORZ GMBH & CO. KG
25 04048551359204 8576CC Laryngoscope, size 3.5 n.a. KARL STORZ GMBH & CO. KG
26 04048551354438 8530DN MILLER Laryngobloc® #1, slender n.a. KARL STORZ GMBH & CO. KG
27 04048551354407 8530EN MILLER Laryngobloc® #0, slender n.a. KARL STORZ GMBH & CO. KG
28 04048551348611 8401HXP C-MAC® Videolaryng. D-BLADE, Ped. C-MAC / dBLADE KARL STORZ GMBH & CO. KG
29 04048551347058 8401HX-1 C-MAC®Videolaryn.D-BLADE, Plastic Handle C-MAC / dBLADE KARL STORZ GMBH & CO. KG
30 04048551346471 8530B MILLER Laryngobloc®, #3 n.a. KARL STORZ GMBH & CO. KG
31 04048551346372 8530C MILLER Laryngobloc®, #2 n.a. KARL STORZ GMBH & CO. KG
32 04048551346310 8575QS Teeth Protector, silicone, autoclavable n.a. KARL STORZ GMBH & CO. KG
33 04048551340042 8402XSB C-MAC® S USB Imager C-MAC KARL STORZ GMBH & CO. KG
34 04048551337912 8403ZX C-MAC® Monitor for CMOS Endoscopes C-MAC KARL STORZ GMBH & CO. KG
35 04048551335703 8668A HINNI Distending Operating Laryngoscope n.a. KARL STORZ GMBH & CO. KG
36 04048551324677 8547HS LED Battery Insert, short n.a. KARL STORZ GMBH & CO. KG
37 04048551324660 8547HL LED Battery Insert, standard n.a. KARL STORZ GMBH & CO. KG
38 04048551324653 8530DS LARYNGOBLOC, MILLER #1, short n.a. KARL STORZ GMBH & CO. KG
39 04048551324646 8530ES LARYNGOBLOC, MILLER #0, short n.a. KARL STORZ GMBH & CO. KG
40 04048551324639 8533FS LARYNGOBLOC, OXFORD #0, short n.a. KARL STORZ GMBH & CO. KG
41 04048551324592 8512CS LARYNGOBLOC, MACINTOSH #2 n.a. KARL STORZ GMBH & CO. KG
42 04048551324554 8533F LARYNGOBLOC, OXFORD #0 n.a. KARL STORZ GMBH & CO. KG
43 04048551324530 8512C LARYNGOBLOC, MACINTOSH #2 n.a. KARL STORZ GMBH & CO. KG
44 04048551318560 8401XA Cable Adaptor for C-MAC® C-MAC KARL STORZ GMBH & CO. KG
45 04048551292921 8402XS C-MAC® S Imager C-MAC KARL STORZ GMBH & CO. KG
46 04048551276198 8401XDL Charging station for C-MAC® PM C-MAC KARL STORZ GMBH & CO. KG
47 04048551268971 8401DXC C-MAC® Videolaryng.MIL#0, Alu. Handle C-MAC KARL STORZ GMBH & CO. KG
48 04048551268964 8401GXC C-MAC® Videolaryng.MAC#1, Alu. Handle C-MAC KARL STORZ GMBH & CO. KG
49 04048551264690 8402X Electronic Module C-MAC KARL STORZ GMBH & CO. KG
50 04048551236925 8583B Laryngoscope, for adults, 16 cm n.a. KARL STORZ GMBH & CO. KG