Other products from "VENNER MEDICAL (SINGAPORE) PTE. LTD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08885009190820 902170 902170 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
2 08885009190844 902190 902190 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
3 08885009190837 902180 902180 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI). BTO Tube, Tracheostomy (W/Wo Connector) 2 Venner™ PneuX P.Y.™ TT MRI
4 08885009190257 702120 702120 The laryngoscope with a MIL Blade size 2 attached is used to assist routine endo The laryngoscope with a MIL Blade size 2 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 2 Blade (clean, non-sterile)
5 18885009190216 701011 701011 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ VL
6 08885009190226 702910 702910 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module (Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(S)
7 08885009190059 701000 701000 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy and endotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Video Viewer and Charger
8 08885009190806 902080 902080 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
9 08885009190813 902090 902090 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
10 08885009190790 902070 902070 The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Tracheostomy tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. BTO Tube, Tracheostomy (W/Wo Connector) Venner™ PneuX P.Y.™ TT
11 18885009190209 701010 701010 A non-sterile device typically designed as a moulded plastic sleeve intended to A non-sterile device typically designed as a moulded plastic sleeve intended to be placed over the reusable laryngoscope device during intubation to create a barrier in order to reduce the cleaning time and turnaround time of the laryngoscope blade for reuse BRY Cabinet, Table And Tray, Anesthesia 1 APA IP Shield™ DL
12 08885009190707 903200 903200 An electro-mechanical system for the control of air pressure within the inflatio An electro-mechanical system for the control of air pressure within the inflation cuff of an Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy tube. BSK Cuff, Tracheal Tube, Inflatable Venner™ Tracheal Seal Monitor
13 08885009190745 901090 901090 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
14 08885009190738 901080 901080 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
15 08885009190721 901070 901070 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
16 08885009190042 700170 700170 The DAB Blades is used with the video laryngoscope to assist endotracheal intuba The DAB Blades is used with the video laryngoscope to assist endotracheal intubations for difficult airways. CCW Laryngoscope, Rigid 1 APA™ DAB (clean, non-sterile)
17 08885009190851 903001 903001 For facilitating the cuff inflation connection between the Venner™ Tracheal Seal For facilitating the cuff inflation connection between the Venner™ Tracheal Seal Monitor and Venner™ PneuX P.Y.™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner™ Tracheal Seal Monitor Extension Tube
18 08885009190783 901190 901190 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
19 08885009190776 901180 901180 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
20 08885009190769 901170 901170 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
21 08885009190752 901160 901160 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also safety in an MRI environment (indicated MRI) and compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) 2 Venner™ PneuX P.Y.™ ETT MRI
22 08885009190325 700330 700330 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 3 Blade
23 08885009190240 702110 702110 The laryngoscope with a MIL Blade size 1 attached is used to assist routine endo The laryngoscope with a MIL Blade size 1 attached is used to assist routine endotracheal intubation in a similar manner to a standard Miller laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MIL 1 Blade (clean, non-sterile)
24 08885009190332 700340 700340 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 MAC 4 Blade
25 08885009190905 903010 903010 For facilitating the cuff inflation connection between the Venner PneuX TSM™ and For facilitating the cuff inflation connection between the Venner PneuX TSM™ and an Venner PneuX™ Endotracheal or Tracheostomy breathing tube. BYX Tubing, Pressure And Accessories 1 Venner PneuX TSM™ Extension Tube(non-sterile)
26 08885009190356 700380 700380 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. BYX,CCW Tubing, Pressure And Accessories,Laryngoscope, Rigid 1 APA™ O2 U-DAB
27 08885009190349 700370 700370 The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition o The APA Oxy Blade is a standard MacIntosh laryngoscope blade with the addition of an oxygen tube adaptor/holder and tubing to provide supplemental oxygen to the patient when using the Venner APA Video Laryngoscope. CCW,BYX Laryngoscope, Rigid,Tubing, Pressure And Accessories 1 APA™ O2 DAB
28 08885009190073 700930 700930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MAC Camera Module
29 08885009190233 702930 702930 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module(Small and Large size). When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ MIL Camera Module(L)
30 08885009190196 701009 701009 A long stiffening wire/rod designed for insertion within the lumen of an artific A long stiffening wire/rod designed for insertion within the lumen of an artificial airway tube (e.g. endotracheal tube) to stiffen and/or maintain the shape of the tube to facilitate introduction (intubation). BSR Stylet, Tracheal Tube 1 APA™ Stylet
31 08885009190714 901060 901060 The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients un The Venner™ PneuX P.Y.™ Endotracheal tube is designed to be used for patients undergoing Tracheal intubation during extended periods (not more than 30 days) of intensive or critical care, and for evacuation or drainage of secretion from the subglottic space. It is also compatible with Tracheal intubation during routine anaesthesia. BTR Tube, Tracheal (W/Wo Connector) Venner™ PneuX P.Y.™ ETT
32 08885009190080 701006 701006 The APA™ Video Laryngoscope is a multi-functional device designed to assist dire The APA™ Video Laryngoscope is a multi-functional device designed to assist direct and indirect laryngoscopy in routine and difficult airway intubations.It may be used to facilitate endotracheal intubation as part of general anaesthesia or CPR (cardiopulmonary resuscitation) during cardiac arrest. The video laryngoscope is reusable, DEHP-free and latex-free. It is fully detachable into three components: APA™ Video Viewer, APA™ Handle and APA™ MAC or MIL Camera Module. When used as a standard laryngoscope, the appropriate Camera Module is attached to the Handle to obtain a view of the laryngeal inlet during endotracheal intubation. When used as a video laryngoscope, the Video Viewer is attached to the Handle and Camera Module to provide improved visualisation during laryngoscopy andendotracheal intubation. CCW Laryngoscope, Rigid 1 APA™ Handle
33 08885009190066 700180 700180 The U-DAB Blades are used with the video laryngoscope to assist endotracheal int The U-DAB Blades are used with the video laryngoscope to assist endotracheal intubations for difficult airways. CCW Laryngoscope, Rigid 1 APA™ U-DAB (clean, non-sterile)
34 08885009190028 700130 700130 The laryngoscope with the MAC Blade size 3 attached is used to assist routine en The laryngoscope with the MAC Blade size 3 attached is used to assist routine endotracheal intubation in a similar manner to a standard Macintosh laryngoscope. CCW Laryngoscope, Rigid 1 APA™ MAC 3 Blade (clean, non-sterile)
Other products with the same Product Code "CCW"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00678467507570 PC-IUESCAM Rigid Laryngoscopes Henke Sass Wolf H & A MUI ENTERPRISES INC
2 00634782074418 4084D-20 4084D-20 Miller Blade, Disposable,#4, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
3 00634782074395 4080-0D-20 4080-0D-20 Miller Blade, Disposable,#00, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
4 00634782074371 4071D-20 4071D-20 Macintosh Blade, Disposable,#1, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
5 00634782074159 4089DN 4089DN Laryngoscope Kit, Miller,Disposable, #0-3 Satin™ AMERICAN DIAGNOSTIC CORP
6 00634782074142 4079DN 4079DN Laryngoscope Kit, Macintosh,Disposable, #2-4 Satin™ AMERICAN DIAGNOSTIC CORP
7 00634782063610 4065D-20 4065D-20 Disposable Laryngo Handle,Medium, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
8 00634782053758 4532-1 4532-1 Lamp, 2.5v for 4065F-4067F, Diagnostix™ AMERICAN DIAGNOSTIC CORP
9 00634782049003 4070F 4070F Satin Macintosh Blade-FO,#0 Satin™ AMERICAN DIAGNOSTIC CORP
10 00634782048921 4067F 4067F Satin Laryngoscope Handle-FO,Stubby, Knurled Finish Satin™ AMERICAN DIAGNOSTIC CORP
11 00634782048914 4067 4067 Satin Laryngoscope Handle,Stubby, Knurled Finish Satin™ AMERICAN DIAGNOSTIC CORP
12 00634782048679 4094 4094 Satin Wisconsin Blade,#4 Satin™ AMERICAN DIAGNOSTIC CORP
13 00634782048662 4093 4093 Satin Wisconsin Blade,#3 Satin™ AMERICAN DIAGNOSTIC CORP
14 00634782048655 4092 4092 Satin Wisconsin Blade,#2 Satin™ AMERICAN DIAGNOSTIC CORP
15 00634782048648 40915 40915 Satin Wisconsin Blade,# 1 1/2 Satin™ AMERICAN DIAGNOSTIC CORP
16 00634782048631 4091 4091 Satin Wisconsin Blade,#1 Satin™ AMERICAN DIAGNOSTIC CORP
17 00634782048624 4090 4090 Satin Wisconsin Blade,#0 Satin™ AMERICAN DIAGNOSTIC CORP
18 00634782039097 4065F 4065F satin Laryngoscope Handle-FO, Medium, Knurled Finish Satin™ AMERICAN DIAGNOSTIC CORP
19 00634782034054 4066F 4066F Satin Laryngoscope Handle-FO, Small, Knurled Finish Satin™ AMERICAN DIAGNOSTIC CORP
20 00634782034047 4066 4066 Satin Laryngoscope Handle, Small, Knurled Finish Satin™ AMERICAN DIAGNOSTIC CORP
21 00634782032876 4065 4065 Satin Laryngoscope Handle,Medium, Knurled Finish Satin™ AMERICAN DIAGNOSTIC CORP
22 00634782002442 4089F 4089F Satin Laryngo Set-Mil-FO,0-4 Satin™ AMERICAN DIAGNOSTIC CORP
23 00634782002435 4089 4089 Satin Laryngo Set-Mil-Std,0-4 Satin™ AMERICAN DIAGNOSTIC CORP
24 00634782002428 4084F 4084F Satin Miller Blade-FO,#4 Satin™ AMERICAN DIAGNOSTIC CORP
25 00634782002411 4084 4084 Satin Miller Blade,#4 Satin™ AMERICAN DIAGNOSTIC CORP
26 00634782002404 4083F 4083F Satin Miller Blade-FO,#3 Satin™ AMERICAN DIAGNOSTIC CORP
27 00634782002398 4083D-20 4083D-20 Miller Blade, Disposable,#3, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
28 00634782002381 4083 4083 Satin Miller Blade,#3 Satin™ AMERICAN DIAGNOSTIC CORP
29 00634782002374 4082F 4082F Satin Miller Blade-FO,#2 Satin™ AMERICAN DIAGNOSTIC CORP
30 00634782002367 4082D-20 4082D-20 Miller Blade, Disposable,#2, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
31 00634782002350 4082 4082 Satin Miller Blade,#2 Satin™ AMERICAN DIAGNOSTIC CORP
32 00634782002343 4081F 4081F Satin Miller Blade-FO,#3 Satin™ AMERICAN DIAGNOSTIC CORP
33 00634782002336 4081D-20 4081D-20 Miller Blade, Disposable,#2 Satin™ AMERICAN DIAGNOSTIC CORP
34 00634782002329 4081 4081 Satin Miller Blade,#1 Satin™ AMERICAN DIAGNOSTIC CORP
35 00634782002312 4080F 4080F Satin Miller Blade-FO,#0 Satin™ AMERICAN DIAGNOSTIC CORP
36 00634782002282 4080-0 4080-0 Satin Miller Blade,#00 Satin™ AMERICAN DIAGNOSTIC CORP
37 00634782002275 4080D-20 4080D-20 Miller Blade, Disposable,#0, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
38 00634782002268 4080 4080 Satin Miller Blade,#0 Satin™ AMERICAN DIAGNOSTIC CORP
39 00634782002251 4079F 4079F Satin Laryngo Set-Mac-FO,1-4 Satin™ AMERICAN DIAGNOSTIC CORP
40 00634782002237 4079 4079 Satin Laryngo Set-Mac-Std,1-4 Satin™ AMERICAN DIAGNOSTIC CORP
41 00634782002220 4074F 4074F Satin Macintosh Blade-FO,#4 Satin™ AMERICAN DIAGNOSTIC CORP
42 00634782002213 4074D-20 4074D-20 Macintosh Blade, Disposable,#4, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
43 00634782002206 4074 4074 Satin Macintosh Blade,#4 Satin™ AMERICAN DIAGNOSTIC CORP
44 00634782002190 4073F 4073F Satin Macintosh Blade-FO,#3 Satin™ AMERICAN DIAGNOSTIC CORP
45 00634782002183 4073D-20 4073D-20 Macintosh Blade, Disposable,#3, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
46 00634782002176 4073 4073 Satin Macintosh Blade,#3 Satin™ AMERICAN DIAGNOSTIC CORP
47 00634782002169 4072F 4072F Satin Macintosh Blade-FO,#2 Satin™ AMERICAN DIAGNOSTIC CORP
48 00634782002152 4072D-20 4072D-20 Macintosh Blade, Disposable,#2, 20/pkg Satin™ AMERICAN DIAGNOSTIC CORP
49 00634782002145 4072 4072 Satin Macintosh Blade,#2 Satin™ AMERICAN DIAGNOSTIC CORP
50 00634782002138 4071F 4071F Satin Macintosh Blade-FO,#1 Satin™ AMERICAN DIAGNOSTIC CORP