Other products from "TAEWOONGMEDICAL.CO.,LTD"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08809744975399 BN0812-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
2 08809744975382 BN0810-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
3 08809744975375 BN0809-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
4 08809744975368 BN0808-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
5 08809744975351 BN0807-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
6 08809744975344 BN0806-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
7 08809744975337 BN0805-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
8 08809744975320 BN0804-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
9 08809744975313 BN0612-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
10 08809744975306 BN0610-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
11 08809744975290 BN0609-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
12 08809744975283 BN0608-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
13 08809744975276 BN0607-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
14 08809744975269 BN0606-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
15 08809744975252 BN0605-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
16 08809744975245 BN0604-6 Bare Metal Biliary Stent System FGE Stents, Drains And Dilators For The Biliary Ducts 2 Niti-S Biliary Slim M Stent
17 08809233102114 BD1012 BD1012 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
18 08809233102091 BD1010 BD1010 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
19 08809233102084 BD1009 BD1009 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
20 08809233102077 BD1008 BD1008 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
21 08809233102060 BD1007 BD1007 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
22 08809233102053 BD1006 BD1006 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
23 08809233102046 BD1005 BD1005 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
24 08809233102039 BD1004 BD1004 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
25 08809233101988 BD0810 BD0810 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
26 08809233101971 BD0809 BD0809 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
27 08809233101964 BD0808 BD0808 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
28 08809233101957 BD0807 BD0807 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
29 08809233101940 BD0806 BD0806 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
30 08809233101933 BD0805 BD0805 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
31 08809233101926 BD0804 BD0804 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
32 08809233100615 TD1012 TD1012 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
33 08809233100592 TD1010 TD1010 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
34 08809233100585 TD1009 TD1009 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
35 08809233100578 TD1008 TD1008 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
36 08809233100561 TD1007 TD1007 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
37 08809233100554 TD1006 TD1006 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
38 08809233100547 TD1005 TD1005 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
39 08809233100530 TD1004 TD1004 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
40 08809233100509 TD0812 TD0812 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
41 08809233100486 TD0810 TD0810 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
42 08809233100479 TD0809 TD0809 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
43 08809233100462 TD0808 TD0808 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
44 08809233100455 TD0807 TD0807 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
45 08809233100448 TD0806 TD0806 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
46 08809233100431 TD0805 TD0805 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
47 08809233100424 TD0804 TD0804 The Niti-S Biliary Stent is indicated for the palliation of malignant strictures The Niti-S Biliary Stent is indicated for the palliation of malignant strictures in the biliary tree.The Niti-S Biliary Stent consists of an implantable metallic stent and a disposable, flexible introducer system for placement of the stent. The stent is a flexible and expandable tubular device made of Nitinol wire that is intended to be implanted to restore the structure and/or function of the biliary system. The introducer is a disposable system for delivery and deployment of the stent at the target position. Upon deployment, the stent imparts an outward radial force on the luminal surface of the biliary system to establish and maintain patency. The stent is available in two diameters (8, 10mm), and eight lengths (40, 50, 60, 70, 80, 90, 100, 120mm). The stent has 10 radiopaque markers.There are two different types of introducers; percutaneous or endoscopic. They consists of an Inner Catheter, Outer Sheath, Hub, Y-connector, Tip and Pusher. All of the components of the introducers are supplied sterile in a disposable package. The Percutaneous type introducer is used when the site is accessed percutaneously and requires a guidewire (not included) to be advanced across the targeted stricture under fluoroscopy. The Endoscopic type introducer is for use in endoscopic procedures where the stent and introducer are inserted through the channel of an endoscope. The usable lengths of Percutaneous type introducer is 50cm and Endoscopic type introducer 180cm. Other information: The package is sterilized using Ethylene oxide. The diameter of compatible guide wire is 0.035 inch (0.89mm). Do not use if package is damaged. Do not reuse or resterilize. FGE Catheter, Biliary, Diagnostic 2 Niti-S Biliary Stent
48 08809744973487 EST2212B-22 Partially Covered Esophageal Stent System ESW Prosthesis, Esophageal 2 Esophageal TTS Stent
49 08809744976181 EST2214B-22 EST2214B-22 Partially Covered Esophageal Stent System ESW Prosthesis, Esophageal 2 Esophageal TTS Stent
50 08809744976174 EST2212B-22 EST2212B-22 Partially Covered Esophageal Stent System ESW Prosthesis, Esophageal 2 Esophageal TTS Stent
Other products with the same Product Code "FGE"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00801741099304 LXB10100 LXB10100 Flexxus® Endoscopic Biliary Stent, 10 mm x 100 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
2 00801741099298 LXB10080 LXB10080 Flexxus® Endoscopic Biliary Stent, 10 mm x 80 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
3 00801741099281 LXB10060 LXB10060 Flexxus® Endoscopic Biliary Stent, 10 mm x 60 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
4 00801741099274 LXB10040 LXB10040 Flexxus® Endoscopic Biliary Stent, 10 mm x 40 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
5 00801741099267 LXB08100 LXB08100 Flexxus® Endoscopic Biliary Stent, 8 mm x 100 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
6 00801741099250 LXB08080 LXB08080 Flexxus® Endoscopic Biliary Stent, 8 mm x 80 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
7 00801741099243 LXB08060 LXB08060 Flexxus® Endoscopic Biliary Stent, 8 mm x 60 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
8 00801741099236 LXB08040 LXB08040 Flexxus® Endoscopic Biliary Stent, 8 mm x 40 mm (190cm deployment system) Flexxus® Endoscopic Biliary Stent ANGIOMED GMBH & CO. MEDIZINTECHNIK KG
9 00801741036866 NBD8 NBD8 Navarre Percutaneous Biliary Drainage Catheter with Nitinol, 8F Locking Pigtail Navarre BARD ACCESS SYSTEMS, INC.
10 00801741036859 NBD12 NBD12 Navarre Percutaneous Biliary Drainage Catheter with Nitinol, 12F Locking Pigtail Navarre BARD ACCESS SYSTEMS, INC.
11 00801741036842 NBD10 NBD10 Navarre Percutaneous Biliary Drainage Catheter with Nitinol, 10F Locking Pigtail Navarre BARD ACCESS SYSTEMS, INC.
12 00801741011627 0015860 0015860 Bile Bag Davol Bile Bag, Small C. R. BARD, INC.
13 00801741011610 0015850 0015850 Bile Bag Davol Bile Bag, Regular C. R. BARD, INC.
14 00801741000980 EV10362CD EV10362CD Valeo® Biliary Stent 10 mm x 36 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
15 00801741000973 EV10361CD EV10361CD Valeo® Biliary Stent 10 mm x 36 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
16 00801741000966 EV10262CD EV10262CD Valeo® Biliary Stent 10 mm x 26 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
17 00801741000959 EV10261CD EV10261CD Valeo® Biliary Stent 10 mm x 26 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
18 00801741000942 EV10172CD EV10172CD Valeo® Biliary Stent 10 mm x 17 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
19 00801741000935 EV10171CD EV10171CD Valeo® Biliary Stent 10 mm x 17 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
20 00801741000928 EV09362CD EV09362CD Valeo® Biliary Stent 9 mm x 36 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
21 00801741000911 EV09361CD EV09361CD Valeo® Biliary Stent 9 mm x 36 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
22 00801741000904 EV09262CD EV09262CD Valeo® Biliary Stent 9 mm x 26 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
23 00801741000898 EV09261CD EV09261CD Valeo® Biliary Stent 9 mm x 26 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
24 00801741000881 EV09172CD EV09172CD Valeo® Biliary Stent 9 mm x 17 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
25 00801741000874 EV09171CD EV09171CD Valeo® Biliary Stent 9 mm x 17 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
26 00801741000867 EV08562CD EV08562CD Valeo® Biliary Stent 8 mm x 56 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
27 00801741000850 EV08561CD EV08561CD Valeo® Biliary Stent 8 mm x 56 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
28 00801741000843 EV08362CD EV08362CD Valeo® Biliary Stent 8 mm x 36 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
29 00801741000836 EV08361CD EV08361CD Valeo® Biliary Stent 8 mm x 36 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
30 00801741000829 EV08262CD EV08262CD Valeo® Biliary Stent 8 mm x 26 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
31 00801741000812 EV08261CD EV08261CD Valeo® Biliary Stent 8 mm x 26 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
32 00801741000805 EV08182CD EV08182CD Valeo® Biliary Stent 8 mm x 18 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
33 00801741000799 EV08181CD EV08181CD Valeo® Biliary Stent 8 mm x 18 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
34 00801741000782 EV07562CD EV07562CD Valeo® Biliary Stent 7 mm x 56 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
35 00801741000775 EV07561CD EV07561CD Valeo® Biliary Stent 7 mm x 56 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
36 00801741000768 EV07362CD EV07362CD Valeo® Biliary Stent 7 mm x 36 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
37 00801741000751 EV07361CD EV07361CD Valeo® Biliary Stent 7 mm x 36 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
38 00801741000744 EV07262CD EV07262CD Valeo® Biliary Stent 7 mm x 26 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
39 00801741000737 EV07261CD EV07261CD Valeo® Biliary Stent 7 mm x 26 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
40 00801741000720 EV07182CD EV07182CD Valeo® Biliary Stent 7 mm x 18 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
41 00801741000713 EV07181CD EV07181CD Valeo® Biliary Stent 7 mm x 18 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
42 00801741000706 EV06362CD EV06362CD Valeo® Biliary Stent, 6 mm x 36 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
43 00801741000690 EV06361CD EV06361CD Valeo® Biliary Stent, 6 mm x 36 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
44 00801741000683 EV06262CD EV06262CD Valeo® Biliary Stent, 6 mm x 26 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
45 00801741000676 EV06261CD EV06261CD Valeo® Biliary Stent, 6 mm x 26 mm (80 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
46 00801741000669 EV06182CD EV06182CD Valeo® Biliary Stent, 6 mm x 18 mm (120 cm delivery catheter) Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
47 00801741000652 EV06181CD EV06181CD Valeo® Biliary Stent, 6 mm x 18 mm, 80 cm catheter length Valeo® Balloon Expandable Biliary Stent BARD PERIPHERAL VASCULAR, INC.
48 00733132638895 VSWVN0804 VSWVN0804 GORE VIABIL Biliary Endoprosthesis W. L. GORE & ASSOCIATES, INC.
49 00733132638888 VSWVN1010 VSWVN1010 GORE VIABIL Biliary Endoprosthesis W. L. GORE & ASSOCIATES, INC.
50 00733132638871 VSWVN1008 VSWVN1008 GORE VIABIL Biliary Endoprosthesis W. L. GORE & ASSOCIATES, INC.