No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 08809263394244 | A | OSM00A0 | Cross Link Driver | MNH,KWP,MNI | Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAM Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
2 | 08800039825269 | A | FA.WC.1005 | Washer (CP4) D10x5 | MRW | SYSTEM, FACET SCREW SPINAL DEVICE | U | Faset |
3 | 08809263393650 | A | OSM6205 | Transverse Link Set 80mm | KWP,MNH,MNI | APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixa APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
4 | 08809557206802 | A | TI.2120 | TLIF(B) Trial L38 x W11 x H16 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
5 | 08809557207212 | A | RY.PL.4106 | ACP - 4-LVL PLATE 106mm | KWQ | Appliance, fixation, spinal intervertebral body | 2 | REX |
6 | 08809557207007 | A | TI.2140 | TLIF(B) Trial L40 x W10 x H16 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
7 | 08809557206147 | A | TI.2034 | TLIF(B) Trial L28 x W10 x H10 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | IVA Cage |
8 | 08809557206109 | A | TI.2030 | TLIF(B) Trial L36 x W9 x H16 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
9 | 08809557205225 | A | TI.2074 | TLIF(B) Trial L32 x W11 x H10 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
10 | 08809557205041 | A | TI.2086 | TLIF(B) Trial L36 x W11 x H12 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
11 | 08809557205003 | A | TI.2082 | TLIF(B) Trial L36 x W11 x H8 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | IVA Cage |
12 | 08809557204457 | A | AL.2092 | ALIF Trial L24 x W35 x A8 x H9 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | IVA Cage |
13 | 08809489299712 | A | DI.2075 | DLIF Trial L50 x W18 x A0 x H15 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
14 | 08809489299606 | A | DI.2042 | DLIF Trial L45 x W18 x A0 x H15 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
15 | 08809489299569 | A | DI.2038 | DLIF Trial L45 x W18 x A0 x H11 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
16 | 08809489299521 | A | DI.2034 | DLIF Trial L45 x W18 x A0 x H7 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
17 | 08809489299293 | A | TI.2011 | TLIF(B) Trial L32 x W9 x H7 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
18 | 08800039820554 | A | SO.IM.0010L | Huvex 10mm | PEK | Spinous process plate | 2 | Huvex |
19 | 08800039820530 | A | SO.IM.0006L | Huvex 6mm | PEK | Spinous process plate | 2 | Huvex |
20 | 08800039820332 | A | FA.IN.3003 | Dilator Small | MRW | SYSTEM, FACET SCREW SPINAL DEVICE | U | Faset |
21 | 08809489298876 | A | AC.2034 | TRIAL L14 x W16 x H6 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA |
22 | 08809489298326 | A | TI.0509 | TLIF DISTRACTOR L28 x W9 x H15 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | IVA |
23 | 08809489298302 | A | TI.0507 | TLIF DISTRACTOR L28 x W9 x H13 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | IVA |
24 | 08809489298173 | A | AL.0100 | ALIF BONE PACKING BAR | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA |
25 | 08809489297091 | TIP.32090009 | 16I636 | TLIF (BULLET) CAGE 32x9x0x9 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
26 | 08809489296995 | TIP.28090009 | 16J549 | TLIF (BULLET) CAGE 28x9x0x09 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
27 | 08809489295523 | A | FX.CD.8535 | Poly Screw D type (Double) 8.5 x 35mm | KWP,MNH,MNI | APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixa APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
28 | 08809489294489 | A | RG.IN.0031 | DRILL BIT, D4.2 | MNH,KWP,MNI | Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAM Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
29 | 08809319782971 | A | FX.PD.6555 | Poly Screw B type (Double) 6.5 x 55mm | KWP,MNH,MNI | APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixa APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
30 | 08809263397856 | A | SCAI-029 | ALIF Packing Bar Square | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | Galaxy |
31 | 08809557206918 | A | TI.2131 | TLIF(B) Trial L40 x W10 x H7 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | IVA Cage |
32 | 08809557206901 | A | TI.2130 | TLIF(B) Trial L40 x W9 x H16 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
33 | 08809263397214 | A | SCPI-021 | PLIF Shaver 8 -021 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | Galaxy |
34 | 08809263396699 | A | A123224 | Galaxy ACIF cage H12 x W32 x L24 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | Galaxy |
35 | 08809557206888 | A | TI.2128 | TLIF(B) Trial L40 x W9 x H14 | ODP,MAX | Intervertebral fusion device with bone graft, cervical,Intervertebral fusion dev Intervertebral fusion device with bone graft, cervical,Intervertebral fusion device with bone graft, lumbar | 2 | IVA Cage |
36 | 08809263394411 | A | OSM0041 | Tester - Thick | MNI,KWP,MNH | ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Ortho ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation | 2 | Rexious |
37 | 08809263394404 | A | OSM0040 | Tester - Thin | MNI,MNH,KWP | ORTHOSIS, SPINAL PEDICLE FIXATION,Orthosis, spondylolisthesis spinal fixation,AP ORTHOSIS, SPINAL PEDICLE FIXATION,Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAMINAL | 2 | Rexious |
38 | 08809263394398 | A | OSM0031 | Probe - Straight | KWP,MNH,MNI | APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixa APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
39 | 08809263394381 | A | OSM0030 | Probe - Curved | MNH,MNI,KWP | Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION,AP Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL | 2 | Rexious |
40 | 08809263394374 | A | OSM0022 | Guide Pin B | MNH,MNI,KWP | Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION,AP Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL | 2 | Rexious |
41 | 08809263394367 | A | OSM0021 | Guide Pin A | KWP,MNH,MNI | APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixa APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
42 | 08809263394350 | A | OSM0010 | Awl | MNI,KWP,MNH | ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Ortho ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation | 2 | Rexious |
43 | 08809263394343 | A | OSM00M0 | Rod Fork | KWP,MNI,MNH | APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION,Ortho APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION,Orthosis, spondylolisthesis spinal fixation | 2 | Rexious |
44 | 08809263394336 | A | OSM00L0 | Retractor | MNH,KWP,MNI | Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAM Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
45 | 08809263394329 | A | OSM00I0 | Rod Holder | MNI,KWP,MNH | ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Ortho ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation | 2 | Rexious |
46 | 08809263394312 | A | OSM00H0 | Derotator | KWP,MNH,MNI | APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixa APPLIANCE, FIXATION, SPINAL INTERLAMINAL,Orthosis, spondylolisthesis spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
47 | 08809263394282 | A | OSM00E0 | Rod Pusher | MNH,KWP,MNI | Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAM Orthosis, spondylolisthesis spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | Rexious |
48 | 08809263396064 | A | NC651514 | Galaxy ACIF cage H6 x W15 x L14 | MAX,ODP | Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion devic Intervertebral fusion device with bone graft, lumbar,Intervertebral fusion device with bone graft, cervical | 2 | Galaxy |
49 | 08809263394947 | A | SH.AL.0007 | Left Angled Hook - 7mm .F | KWP | APPLIANCE, FIXATION, SPINAL INTERLAMINAL | 2 | Rexious HOOK |
50 | 08809263394930 | A | SH.AL.0005 | Left Angled Hook - 5mm .F | KWP | APPLIANCE, FIXATION, SPINAL INTERLAMINAL | 2 | Rexious HOOK |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 04047844014059 | Cervical cage, angled | WK101212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
2 | 04047844014042 | Cervical cage, angled | WK091212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
3 | 04047844010617 | Cervical cage | NB121317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
4 | 04047844010600 | Cervical cage | NB111317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
5 | 04047844010594 | Cervical cage | NB101317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
6 | 04047844010587 | Cervical cage | NB091317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
7 | 04047844010570 | Cervical cage | NB081317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
8 | 04047844010563 | Cervical cage | NB071317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
9 | 04047844010556 | Cervical cage | NB061317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
10 | 04047844010549 | Cervical cage | NB051317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
11 | 04047844010532 | Cervical cage | NB041317 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
12 | 04047844009192 | Cervical cage | NB111314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
13 | 04047844009178 | Cervical cage with strut | N111314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
14 | 04047844009161 | Cervical cage with strut | N101314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
15 | 04047844009154 | Cervical cage with strut | N091314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
16 | 04047844002414 | Connection screw | ATM309 | The ATHLET VBR System is a lordotic, modular vertebral body replacement system. The ATHLET VBR System is a lordotic, modular vertebral body replacement system. Caudal and cranial components are offered in a variety of heights and are assembled to create a device construct. An intermediate component is also available and is used between one caudal and one cranial component. The device construct comprises a central cannula for bone graft and lateral fenestrations for bony in-growth. | ATHLET | SIGNUS MEDIZINTECHNIK GMBH |
17 | 04047844002056 | Cervical cage with strut | N081314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
18 | 04047844002049 | Cervical cage with strut | N071314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
19 | 04047844002032 | Cervical cage with strut | N061314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
20 | 04047844002025 | Cervical cage with strut | N051314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
21 | 04047844002018 | Cervical cage with strut | N041314 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | NUBIC | SIGNUS MEDIZINTECHNIK GMBH |
22 | 04047844000694 | Cervical cage, angled | WK081414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
23 | 04047844000687 | Cervical cage, angled | WK081214 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
24 | 04047844000670 | Cervical cage, angled | WK081212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
25 | 04047844000663 | Cervical cage, angled | WK071414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
26 | 04047844000656 | Cervical cage, angled | WK071212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
27 | 04047844000649 | Cervical cage, angled | WK061414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
28 | 04047844000632 | Cervical cage, angled | WK061212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
29 | 04047844000625 | Cervical cage, angled | WK051414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
30 | 04047844000618 | Cervical cage, angled | WK051212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
31 | 04047844000601 | Cervical cage, angled | WK041414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
32 | 04047844000595 | Cervical cage, angled | WK041212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 5° | SIGNUS MEDIZINTECHNIK GMBH |
33 | 04047844000588 | Cervical cage, straight | PK101214 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
34 | 04047844000571 | Cervical cage, straight | PK101212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
35 | 04047844000564 | Cervical cage, straight | PK091214 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
36 | 04047844000557 | Cervical cage, straight | PK091212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
37 | 04047844000540 | Cervical cage, straight | PK081414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
38 | 04047844000533 | Cervical cage, straight | PK081216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
39 | 04047844000526 | Cervical cage, straight | PK081212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
40 | 04047844000519 | Cervical cage, straight | PK071414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
41 | 04047844000502 | Cervical cage, straight | PK071216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
42 | 04047844000496 | Cervical cage, straight | PK071212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
43 | 04047844000489 | Cervical cage, straight | PK061414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
44 | 04047844000472 | Cervical cage, straight | PK061216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
45 | 04047844000465 | Cervical cage, straight | PK061212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
46 | 04047844000458 | Cervical cage, straight | PK051414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
47 | 04047844000441 | Cervical cage, straight | PK051216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
48 | 04047844000434 | Cervical cage, straight | PK051212 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
49 | 04047844000427 | Cervical cage, straight | PK041414 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |
50 | 04047844000410 | Cervical cage, straight | PK041216 | The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper The basic shape of the NUBIC and RABEA devices is a rectangular frame. The upper and lower aspects of the implant are open with surface spikes which assist in the positive anchorage and seating between the superior and inferior vertebral bodies. The device is available in a variety of sizes enabling the surgeon to choose the size best suited to the individual pathology and anantomical condition. A connecting screw is available which permits attachment of the NUBIC (without strut) to the SIGNUS TOSCA II anterior cervical plate if the surgeon so chooses. | RABEA 0° | SIGNUS MEDIZINTECHNIK GMBH |