No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 08800019200406 | DT-703 | ECO-ER-CAT-001DT | - Extraoral source x-ray systemBattery Input: 22.2V, 1AOutput Rating: 210WkVp: 7 - Extraoral source x-ray systemBattery Input: 22.2V, 1AOutput Rating: 210WkVp: 70kVmA: 3mASec: 0.02 - 0.5sec | EHD | Unit, X-Ray, Extraoral With Timer | 2 | N/A |
2 | 08800019200277 | Anyview-500DR | ECO-ER-CAT-001DR | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5.0kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5.0kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch | OXO,JAA,OWB | Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified,Interventional Fluoroscopic X-Ray System | 2 | NA |
3 | 08800019200260 | Anyview-320DR | ECO-ER-CAT-001DR | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 15~40mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch | OWB,JAA,OXO | Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Inte Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,Image-Intensified Fluoroscopic X-Ray System, Mobile | 2 | NA |
4 | 08800019200253 | Anyview-240DR | ECO-ER-CAT-001DR | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 2.4kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 2.4kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 16~30mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch | OXO,JAA,OWB | Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified,Interventional Fluoroscopic X-Ray System | 2 | NA |
5 | 08800019200161 | SXG-80R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, 500mA@150kV) KVP range: 40~150kVpmA range: 10~1000mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
6 | 08800019200154 | SXG-68R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 4 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 400mA@150kV) KVP range: 40~150kVpmA range: 10~800mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
7 | 08800019200147 | SXG-52R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 3 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 320mA@150kV) KVP range: 40~150kVpmA range: 10~640mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
8 | 08800019200130 | SXG-40R | ECO-ER-CAT-001S | LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320 LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320mA@125kV) KVP range: 40~125kVpmA range: 10~500mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
9 | 08800019200093 | Anyview-500R | ECO-ER-CAT-002C | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5kW3. Fluoroscopy Mode - F-m 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Image Intensifier - E5830SD-PA4(TOSHIBA), 9inch7. Camera - CCD, Resolution: 1K X 1K | OWB,JAA,OXO | Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Inte Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,Image-Intensified Fluoroscopic X-Ray System, Mobile | 2 | NA |
10 | 08800019200055 | EPX-F5000 | ECO-ER-CAT-001P | Input Power: 200V~240V, 50/60HzOutput Power: 5.0kWKVP range: 50~110kVmA range: 2 Input Power: 200V~240V, 50/60HzOutput Power: 5.0kWKVP range: 50~110kVmA range: 20~100mAmAs range: 0.4~100mAsX-ray Tube: OX/110-15Focal Sport: 1.8 x 1.8mmTarget Angle: 15 degreesAnode heat storage: 42kHU | IZL | System, X-Ray, Mobile | 2 | NA |
11 | 08800019200048 | EPX-F4000 | ECO-ER-CAT-001P | Input Power: 200V~240V, 50/60HzOutput Power: 4.0kWKVP range: 50~110kVmA range: 2 Input Power: 200V~240V, 50/60HzOutput Power: 4.0kWKVP range: 50~110kVmA range: 20~80mAmAs range: 0.4~100mAsX-ray Tube: OX/110-15Focal Sport: 1.8 x 1.8mmTarget Angle: 15 degreesAnode heat storage: 42kHU | IZL | System, X-Ray, Mobile | 2 | NA |
12 | 08800019200031 | EPX-F3200 | ECO-ER-CAT-001P | Input Power: 200V~240V, 50/60HzOutput Power: 3.2kWKVP range: 40~100kVmA range: 2 Input Power: 200V~240V, 50/60HzOutput Power: 3.2kWKVP range: 40~100kVmA range: 25~60mAmAs range: 0.4~100mAsX-ray Tube: D-205BFocal Sport: 2.0 x 2.0mmTarget Angle: 20 degreesAnode heat storage: 40kHU | IZL | System, X-Ray, Mobile | 2 | NA |
13 | 08800019200024 | EPX-F2800 | ECO-ER-CAT-001P | Input Power: 110V~120V, 50/60HzOutput Power: 2.8kWKVP range: 40~120kVmA range: 1 Input Power: 110V~120V, 50/60HzOutput Power: 2.8kWKVP range: 40~120kVmA range: 14~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU | IZL | System, X-Ray, Mobile | 2 | NA |
14 | 08800019200017 | EPX-F2400 | ECO-ER-CAT-001P | Input Power: 110V~120V, 50/60HzOutput Power: 2.4kWKVP range: 40~100kVmA range: 1 Input Power: 110V~120V, 50/60HzOutput Power: 2.4kWKVP range: 40~100kVmA range: 16~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU | IZL | System, X-Ray, Mobile | 2 | NA |
15 | 08800019200000 | EPX-F1600 | ECO-ER-CAT-001P | Input Power: 110V~120V, 50/60HzOutput Power: 1.6kWKVP range: 40~90kVmA range: 12 Input Power: 110V~120V, 50/60HzOutput Power: 1.6kWKVP range: 40~90kVmA range: 12~30mAmAs range: 0.4~32mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU | IZL | System, X-Ray, Mobile | 2 | NA |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 08800019200161 | SXG-80R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, 500mA@150kV) KVP range: 40~150kVpmA range: 10~1000mAmAs Range: 0.1~500mAs | N/A | ECOTRON |
2 | 08800019200154 | SXG-68R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 4 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 400mA@150kV) KVP range: 40~150kVpmA range: 10~800mAmAs Range: 0.1~500mAs | N/A | ECOTRON |
3 | 08800019200147 | SXG-52R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 3 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 320mA@150kV) KVP range: 40~150kVpmA range: 10~640mAmAs Range: 0.1~500mAs | N/A | ECOTRON |
4 | 08800019200130 | SXG-40R | ECO-ER-CAT-001S | LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320 LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320mA@125kV) KVP range: 40~125kVpmA range: 10~500mAmAs Range: 0.1~500mAs | N/A | ECOTRON |
5 | 08800019200123 | SXG-32R | ECO-ER-CAT-001S | LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 32kW(400mA@80kV, 320mA@100kV, 250 LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 32kW(400mA@80kV, 320mA@100kV, 250mA@125kV) KVP range: 40~125kVpmA range: 10~400mAmAs Range: 0.1~400mAs | N/A | ECOTRON |
6 | 08800011110352 | GXR-U40 | *Line power rating: 100-240V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
7 | 08800011110345 | GXR-U32 | *Line power rating: 100-240V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
8 | 08800011110338 | GXR-C52 | *Line power rating: 220-230V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
9 | 08800011110321 | GXR-C52 | *Line power rating: 220-230V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
10 | 08800011110314 | GXR-C52 | *Line power rating: 110-120V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
11 | 08800011110307 | GXR-C40 | *Line power rating: 220-230V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
12 | 08800011110291 | GXR-C40 | *Line power rating: 220-230V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
13 | 08800011110284 | GXR-C40 | *Line power rating: 110-120V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
14 | 08800011110277 | GXR-C32 | *Line power rating: 220-230V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
15 | 08800011110260 | GXR-C32 | *Line power rating: 220-230V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
16 | 08800011110253 | GXR-C32 | *Line power rating: 110-120V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
17 | 08800011110246 | GXR-82 | *Line power rating: 480V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
18 | 08800011110239 | GXR-68 | *Line power rating: 480V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
19 | 08800011110222 | GXR-52 | *Line power rating: 480V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
20 | 08800011110215 | GXR-40 | *Line power rating: 480V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
21 | 08800011110208 | GXR-40 | *Line power rating: 480V3~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
22 | 08800011110192 | GXR-40 | *Line power rating: 400V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
23 | 08800011110185 | GXR-40 | *Line power rating: 400V3~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
24 | 08800011110178 | GXR-32 | *Line power rating: 480V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
25 | 08800011110161 | GXR-32 | *Line power rating: 480V3~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
26 | 08800011110154 | GXR-32 | *Line power rating: 400V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
27 | 08800011110147 | GXR-32 | *Line power rating: 400V3~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
28 | 08800011110123 | GXR-U40 | *Line power rating: 100-240V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
29 | 08800011110116 | GXR-U32 | *Line power rating: 100-240V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
30 | 08800011110109 | GXR-C52 | *Line power rating: 110-120V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
31 | 08800011110093 | GXR-C40 | *Line power rating: 110-120V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
32 | 08800011110086 | GXR-C32 | *Line power rating: 110-120V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
33 | 08800011110079 | GXR-82 | *Line power rating: 400V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
34 | 08800011110062 | GXR-68 | *Line power rating: 400V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
35 | 08800011110055 | GXR-52 | *Line power rating: 400V3~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
36 | 08800011110048 | GXR-40 | *Line power rating: 220-230V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
37 | 08800011110031 | GXR-40 | *Line power rating: 220-230V~*MAX tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
38 | 08800011110024 | GXR-32 | *Line power rating: 220-230V~*MAX tube voltage: 150kV | DRGEM | DRGEM CORPORATION | |
39 | 08800011110017 | GXR-32 | *Line power rating: 220-230V~ *MAX Tube voltage: 125kV | DRGEM | DRGEM CORPORATION | |
40 | 08718755003147 | ICX1940B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
41 | 08718755003130 | ICX314B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
42 | 08718755003123 | ICX555B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
43 | 08718755003116 | ICX436B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
44 | 08718755003109 | ICX975B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
45 | 08718755003093 | INX147B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
46 | 08718755003086 | ICX914B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
47 | 08718755003079 | ICX1995B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
48 | 08718755003062 | ICX1977B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
49 | 08718755003055 | ICX3722B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION | |
50 | 08718755003048 | ICX722B | An Ionization Chamber is a device that is placed between the patient and an x-ra An Ionization Chamber is a device that is placed between the patient and an x-ray image receptor to assist the Automatic Exposure Control (AEC) in delivering the proper x-ray dose in medical radiography.This is a device out of the Ionization Chambers series. | Varex Imaging | VAREX IMAGING CORPORATION |