Other products from "ECOTRON"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08800019200406 DT-703 ECO-ER-CAT-001DT - Extraoral source x-ray systemBattery Input: 22.2V, 1AOutput Rating: 210WkVp: 7 - Extraoral source x-ray systemBattery Input: 22.2V, 1AOutput Rating: 210WkVp: 70kVmA: 3mASec: 0.02 - 0.5sec EHD Unit, X-Ray, Extraoral With Timer 2 N/A
2 08800019200277 Anyview-500DR ECO-ER-CAT-001DR 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5.0kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5.0kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch OXO,JAA,OWB Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified,Interventional Fluoroscopic X-Ray System 2 NA
3 08800019200260 Anyview-320DR ECO-ER-CAT-001DR 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 15~40mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch OWB,JAA,OXO Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Inte Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,Image-Intensified Fluoroscopic X-Ray System, Mobile 2 NA
4 08800019200253 Anyview-240DR ECO-ER-CAT-001DR 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 2.4kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 2.4kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 16~30mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch OXO,JAA,OWB Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified,Interventional Fluoroscopic X-Ray System 2 NA
5 08800019200161 SXG-80R ECO-ER-CAT-001S LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, 500mA@150kV) KVP range: 40~150kVpmA range: 10~1000mAmAs Range: 0.1~500mAs IZO Generator, High-Voltage, X-Ray, Diagnostic 1 N/A
6 08800019200154 SXG-68R ECO-ER-CAT-001S LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 4 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 400mA@150kV) KVP range: 40~150kVpmA range: 10~800mAmAs Range: 0.1~500mAs IZO Generator, High-Voltage, X-Ray, Diagnostic 1 N/A
7 08800019200147 SXG-52R ECO-ER-CAT-001S LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 3 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 320mA@150kV) KVP range: 40~150kVpmA range: 10~640mAmAs Range: 0.1~500mAs IZO Generator, High-Voltage, X-Ray, Diagnostic 1 N/A
8 08800019200130 SXG-40R ECO-ER-CAT-001S LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320 LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320mA@125kV) KVP range: 40~125kVpmA range: 10~500mAmAs Range: 0.1~500mAs IZO Generator, High-Voltage, X-Ray, Diagnostic 1 N/A
9 08800019200123 SXG-32R ECO-ER-CAT-001S LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 32kW(400mA@80kV, 320mA@100kV, 250 LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 32kW(400mA@80kV, 320mA@100kV, 250mA@125kV) KVP range: 40~125kVpmA range: 10~400mAmAs Range: 0.1~400mAs IZO Generator, High-Voltage, X-Ray, Diagnostic 1 N/A
10 08800019200093 Anyview-500R ECO-ER-CAT-002C 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5kW3. Fluoroscopy Mode - F-m 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Image Intensifier - E5830SD-PA4(TOSHIBA), 9inch7. Camera - CCD, Resolution: 1K X 1K OWB,JAA,OXO Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Inte Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,Image-Intensified Fluoroscopic X-Ray System, Mobile 2 NA
11 08800019200048 EPX-F4000 ECO-ER-CAT-001P Input Power: 200V~240V, 50/60HzOutput Power: 4.0kWKVP range: 50~110kVmA range: 2 Input Power: 200V~240V, 50/60HzOutput Power: 4.0kWKVP range: 50~110kVmA range: 20~80mAmAs range: 0.4~100mAsX-ray Tube: OX/110-15Focal Sport: 1.8 x 1.8mmTarget Angle: 15 degreesAnode heat storage: 42kHU IZL System, X-Ray, Mobile 2 NA
12 08800019200031 EPX-F3200 ECO-ER-CAT-001P Input Power: 200V~240V, 50/60HzOutput Power: 3.2kWKVP range: 40~100kVmA range: 2 Input Power: 200V~240V, 50/60HzOutput Power: 3.2kWKVP range: 40~100kVmA range: 25~60mAmAs range: 0.4~100mAsX-ray Tube: D-205BFocal Sport: 2.0 x 2.0mmTarget Angle: 20 degreesAnode heat storage: 40kHU IZL System, X-Ray, Mobile 2 NA
13 08800019200024 EPX-F2800 ECO-ER-CAT-001P Input Power: 110V~120V, 50/60HzOutput Power: 2.8kWKVP range: 40~120kVmA range: 1 Input Power: 110V~120V, 50/60HzOutput Power: 2.8kWKVP range: 40~120kVmA range: 14~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU IZL System, X-Ray, Mobile 2 NA
14 08800019200017 EPX-F2400 ECO-ER-CAT-001P Input Power: 110V~120V, 50/60HzOutput Power: 2.4kWKVP range: 40~100kVmA range: 1 Input Power: 110V~120V, 50/60HzOutput Power: 2.4kWKVP range: 40~100kVmA range: 16~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU IZL System, X-Ray, Mobile 2 NA
15 08800019200000 EPX-F1600 ECO-ER-CAT-001P Input Power: 110V~120V, 50/60HzOutput Power: 1.6kWKVP range: 40~90kVmA range: 12 Input Power: 110V~120V, 50/60HzOutput Power: 1.6kWKVP range: 40~90kVmA range: 12~30mAmAs range: 0.4~32mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU IZL System, X-Ray, Mobile 2 NA
Other products with the same Product Code "IZL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04540217064991 566-20000-26 Mobirex i9 SHIMADZU CORPORATION
2 04540217060832 503-79999-11 MobileDaRt Evolution SHIMADZU CORPORATION
3 04540217059638 566-20000-10 MobileDaRt Evolution SHIMADZU CORPORATION
4 04540217059621 503-79999-01 MobileDaRt Evolution SHIMADZU CORPORATION
5 04540217059515 566-20000-19 FDR Go SHIMADZU CORPORATION
6 04540217059379 566-20000-18 FDR Go SHIMADZU CORPORATION
7 04540217053513 503-79888-51 MobileArt Evolution SHIMADZU CORPORATION
8 04540217053506 503-79888-41 MobileDaRt Evolution SHIMADZU CORPORATION
9 04540217053476 503-79888-21 MobileDaRt Evolution SHIMADZU CORPORATION
10 04540217053438 503-79888-11 FDR Go SHIMADZU CORPORATION
11 04056869154992 11107444 MOBILETT Elara Max SIEMENS HEALTHCARE GMBH
12 04056869009131 10594738 Mobile Generator Mobilett Mira Max SIEMENS HEALTHCARE GMBH
13 04056869009094 01818454 Mobile Generator Mobilett XP hybrid SIEMENS HEALTHCARE GMBH
14 04056869009087 01818363 Mobile Generator Mobilett XP SIEMENS HEALTHCARE GMBH
15 EKAV101152780 1.011.5278 FP 0203 Handheld x-ray NOMAD MD™ handheld X-ray system ARIBEX, INC.
16 EKAV085004710 0.850.0471 FP 0202 Handheld x-ray NOMAD MD™ handheld X-ray system ARIBEX, INC.
17 EKAV085004700 0.850.0470 FP 0204 Handheld x-ray NOMAD MD™ handheld X-ray system ARIBEX, INC.
18 EKAV085001120 0.850.0112 AP 0200 Handheld X-ray NOMAD MD™ handheld X-ray system ARIBEX, INC.
19 EKAV085000300 0.850.0030 FP 0201 Handheld X-ray NOMAD MD™ handheld X-ray system ARIBEX, INC.
20 00935712300004 Rover MXU-RV01 The device is designed to perform radiographic x-ray examinations on pediatric a The device is designed to perform radiographic x-ray examinations on pediatric and adult patients, in all patient treatment areas Micro-X MICRO-X LIMITED
21 00868162000289 RC-115 900035 X-Ray Control, Remote RC-115 SOURCE-RAY, INC.
22 00868162000272 SR-1260-G 910222 X-Ray Generator / Tube Housing Assembly, 120kVp / 60mA SR-1260-G SOURCE-RAY, INC.
23 00868162000265 SR-1260-C 910224 X-Ray Control, 120 kVp / 60mA SR-1260-C SOURCE-RAY, INC.
24 00868162000258 SR-130-C 910002 X-Ray Control, 100kVp / 30 mA SR-130-C SOURCE-RAY, INC.
25 00868162000241 SR-130-G 910056 X-Ray Generator / Tube Housing Assembly, 100kVp / 30mA SR-130-G SOURCE-RAY, INC.
26 00868162000234 SR-115 900033 X-Ray Control / Generator, 100 kVp/ 15mA SR-115-CG SOURCE-RAY, INC.
27 00867538000304 UC-5000 900117 Mobile X-Ray System for General Purpose Radiography Exams Utilizing Film, Comput Mobile X-Ray System for General Purpose Radiography Exams Utilizing Film, Computed Radiography, or Direct Digital Flat Panels UC-5000 SOURCE-RAY, INC.
28 00860290000360 11020 xCAT IQ XORAN TECHNOLOGIES LLC
29 00860290000346 11010 xCAT XL XORAN TECHNOLOGIES LLC
30 00860290000339 11000 xCAT XORAN TECHNOLOGIES LLC
31 00860008892751 ACSY-S009 Micro C Load Bearing Cassette Plate, ACSY-S009 OXOS MEDICAL, INC.
32 00860001123470 ACSY-S021 OXBox OXOS MEDICAL, INC.
33 00860001123432 ACSY-P036 Micro C Medical Imaging System, M01 Foot Pedal OXOS MEDICAL, INC.
34 00860001123401 M01 Micro C Medical Imaging System, M01 OXOS MEDICAL, INC.
35 00858846007253 TR90BH The TR90BH is a portable X-ray system with following limitations of use: The de The TR90BH is a portable X-ray system with following limitations of use: The device may be used for handheld diagnostic imaging of body extremities The device may be used for stand mounted diagnostic imaging of head, abdomen, or extremities. The device may be used for stand mounted imaging of the chest when used without a grid. - Not to be used on bariatric patients, unless imaging body extremities - Not for mammography use - The TR90BH is not intended to replace a stationary radiographic system, which may be required for full optimization of image quality and radiation exposure for different exam types. MinXray MINXRAY, INC.
36 00858846007246 HFP24 Podiatric X-ray unit This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This is a podiatric mono-block type high frequency portable x-ray unit. The unit can be used with conventional diagnostic film or with solid-state digital radiographic sensors MinXray MINXRAY, INC.
37 00858846007239 HFP40 Portable X-ray unit This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This is a mono-block type high frequency portable x-ray unit. The unit can be used with conventional diagnostic film or with solid-state digital radiographic sensors. MinXray MINXRAY, INC.
38 00858846007222 CMDR.TW.1202.R This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
39 00858846007215 CMDR.PE.1202.S This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
40 00858846007208 CMDR.PE.120.60.S This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
41 00858846007192 CMDR.TW.120.60.R This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
42 00858846007185 CMDR.PE.100.R This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
43 00858846007178 Integris This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
44 00858846007161 CMDR.PE.120.60.R This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
45 00858846007154 CMDR.TW.120.60.S This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
46 00858846007147 CMDR.T.100.S This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
47 00858846007130 CMDR.TW.100.R This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
48 00858846007123 CMDR.TW.1202.S This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
49 00858846007116 CMDR.T.1202.R This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.
50 00858846007109 CMDR.T.1202.S This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. MinXray MINXRAY, INC.