No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 08800019200406 | DT-703 | ECO-ER-CAT-001DT | - Extraoral source x-ray systemBattery Input: 22.2V, 1AOutput Rating: 210WkVp: 7 - Extraoral source x-ray systemBattery Input: 22.2V, 1AOutput Rating: 210WkVp: 70kVmA: 3mASec: 0.02 - 0.5sec | EHD | Unit, X-Ray, Extraoral With Timer | 2 | N/A |
2 | 08800019200277 | Anyview-500DR | ECO-ER-CAT-001DR | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5.0kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5.0kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch | OXO,JAA,OWB | Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified,Interventional Fluoroscopic X-Ray System | 2 | NA |
3 | 08800019200260 | Anyview-320DR | ECO-ER-CAT-001DR | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 15~40mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch | OWB,JAA,OXO | Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Inte Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,Image-Intensified Fluoroscopic X-Ray System, Mobile | 2 | NA |
4 | 08800019200253 | Anyview-240DR | ECO-ER-CAT-001DR | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 2.4kW3. Fluoroscopy Mode - F 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 2.4kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 16~30mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch | OXO,JAA,OWB | Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified Fluoroscopic X-Ray System, Mobile,System, X-Ray, Fluoroscopic, Image-Intensified,Interventional Fluoroscopic X-Ray System | 2 | NA |
5 | 08800019200161 | SXG-80R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, 500mA@150kV) KVP range: 40~150kVpmA range: 10~1000mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
6 | 08800019200154 | SXG-68R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 4 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 400mA@150kV) KVP range: 40~150kVpmA range: 10~800mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
7 | 08800019200147 | SXG-52R | ECO-ER-CAT-001S | LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 3 LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 320mA@150kV) KVP range: 40~150kVpmA range: 10~640mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
8 | 08800019200130 | SXG-40R | ECO-ER-CAT-001S | LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320 LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320mA@125kV) KVP range: 40~125kVpmA range: 10~500mAmAs Range: 0.1~500mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
9 | 08800019200123 | SXG-32R | ECO-ER-CAT-001S | LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 32kW(400mA@80kV, 320mA@100kV, 250 LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 32kW(400mA@80kV, 320mA@100kV, 250mA@125kV) KVP range: 40~125kVpmA range: 10~400mAmAs Range: 0.1~400mAs | IZO | Generator, High-Voltage, X-Ray, Diagnostic | 1 | N/A |
10 | 08800019200093 | Anyview-500R | ECO-ER-CAT-002C | 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5kW3. Fluoroscopy Mode - F-m 1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Image Intensifier - E5830SD-PA4(TOSHIBA), 9inch7. Camera - CCD, Resolution: 1K X 1K | OWB,JAA,OXO | Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Inte Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,Image-Intensified Fluoroscopic X-Ray System, Mobile | 2 | NA |
11 | 08800019200048 | EPX-F4000 | ECO-ER-CAT-001P | Input Power: 200V~240V, 50/60HzOutput Power: 4.0kWKVP range: 50~110kVmA range: 2 Input Power: 200V~240V, 50/60HzOutput Power: 4.0kWKVP range: 50~110kVmA range: 20~80mAmAs range: 0.4~100mAsX-ray Tube: OX/110-15Focal Sport: 1.8 x 1.8mmTarget Angle: 15 degreesAnode heat storage: 42kHU | IZL | System, X-Ray, Mobile | 2 | NA |
12 | 08800019200031 | EPX-F3200 | ECO-ER-CAT-001P | Input Power: 200V~240V, 50/60HzOutput Power: 3.2kWKVP range: 40~100kVmA range: 2 Input Power: 200V~240V, 50/60HzOutput Power: 3.2kWKVP range: 40~100kVmA range: 25~60mAmAs range: 0.4~100mAsX-ray Tube: D-205BFocal Sport: 2.0 x 2.0mmTarget Angle: 20 degreesAnode heat storage: 40kHU | IZL | System, X-Ray, Mobile | 2 | NA |
13 | 08800019200024 | EPX-F2800 | ECO-ER-CAT-001P | Input Power: 110V~120V, 50/60HzOutput Power: 2.8kWKVP range: 40~120kVmA range: 1 Input Power: 110V~120V, 50/60HzOutput Power: 2.8kWKVP range: 40~120kVmA range: 14~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU | IZL | System, X-Ray, Mobile | 2 | NA |
14 | 08800019200017 | EPX-F2400 | ECO-ER-CAT-001P | Input Power: 110V~120V, 50/60HzOutput Power: 2.4kWKVP range: 40~100kVmA range: 1 Input Power: 110V~120V, 50/60HzOutput Power: 2.4kWKVP range: 40~100kVmA range: 16~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU | IZL | System, X-Ray, Mobile | 2 | NA |
15 | 08800019200000 | EPX-F1600 | ECO-ER-CAT-001P | Input Power: 110V~120V, 50/60HzOutput Power: 1.6kWKVP range: 40~90kVmA range: 12 Input Power: 110V~120V, 50/60HzOutput Power: 1.6kWKVP range: 40~90kVmA range: 12~30mAmAs range: 0.4~32mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU | IZL | System, X-Ray, Mobile | 2 | NA |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 04540217064991 | 566-20000-26 | Mobirex i9 | SHIMADZU CORPORATION | ||
2 | 04540217060832 | 503-79999-11 | MobileDaRt Evolution | SHIMADZU CORPORATION | ||
3 | 04540217059638 | 566-20000-10 | MobileDaRt Evolution | SHIMADZU CORPORATION | ||
4 | 04540217059621 | 503-79999-01 | MobileDaRt Evolution | SHIMADZU CORPORATION | ||
5 | 04540217059515 | 566-20000-19 | FDR Go | SHIMADZU CORPORATION | ||
6 | 04540217059379 | 566-20000-18 | FDR Go | SHIMADZU CORPORATION | ||
7 | 04540217053513 | 503-79888-51 | MobileArt Evolution | SHIMADZU CORPORATION | ||
8 | 04540217053506 | 503-79888-41 | MobileDaRt Evolution | SHIMADZU CORPORATION | ||
9 | 04540217053476 | 503-79888-21 | MobileDaRt Evolution | SHIMADZU CORPORATION | ||
10 | 04540217053438 | 503-79888-11 | FDR Go | SHIMADZU CORPORATION | ||
11 | 04056869154992 | 11107444 | MOBILETT Elara Max | SIEMENS HEALTHCARE GMBH | ||
12 | 04056869009131 | 10594738 | Mobile Generator | Mobilett Mira Max | SIEMENS HEALTHCARE GMBH | |
13 | 04056869009094 | 01818454 | Mobile Generator | Mobilett XP hybrid | SIEMENS HEALTHCARE GMBH | |
14 | 04056869009087 | 01818363 | Mobile Generator | Mobilett XP | SIEMENS HEALTHCARE GMBH | |
15 | EKAV101152780 | 1.011.5278 | FP 0203 | Handheld x-ray | NOMAD MD™ handheld X-ray system | ARIBEX, INC. |
16 | EKAV085004710 | 0.850.0471 | FP 0202 | Handheld x-ray | NOMAD MD™ handheld X-ray system | ARIBEX, INC. |
17 | EKAV085004700 | 0.850.0470 | FP 0204 | Handheld x-ray | NOMAD MD™ handheld X-ray system | ARIBEX, INC. |
18 | EKAV085001120 | 0.850.0112 | AP 0200 | Handheld X-ray | NOMAD MD™ handheld X-ray system | ARIBEX, INC. |
19 | EKAV085000300 | 0.850.0030 | FP 0201 | Handheld X-ray | NOMAD MD™ handheld X-ray system | ARIBEX, INC. |
20 | 00935712300004 | Rover | MXU-RV01 | The device is designed to perform radiographic x-ray examinations on pediatric a The device is designed to perform radiographic x-ray examinations on pediatric and adult patients, in all patient treatment areas | Micro-X | MICRO-X LIMITED |
21 | 00868162000289 | RC-115 | 900035 | X-Ray Control, Remote | RC-115 | SOURCE-RAY, INC. |
22 | 00868162000272 | SR-1260-G | 910222 | X-Ray Generator / Tube Housing Assembly, 120kVp / 60mA | SR-1260-G | SOURCE-RAY, INC. |
23 | 00868162000265 | SR-1260-C | 910224 | X-Ray Control, 120 kVp / 60mA | SR-1260-C | SOURCE-RAY, INC. |
24 | 00868162000258 | SR-130-C | 910002 | X-Ray Control, 100kVp / 30 mA | SR-130-C | SOURCE-RAY, INC. |
25 | 00868162000241 | SR-130-G | 910056 | X-Ray Generator / Tube Housing Assembly, 100kVp / 30mA | SR-130-G | SOURCE-RAY, INC. |
26 | 00868162000234 | SR-115 | 900033 | X-Ray Control / Generator, 100 kVp/ 15mA | SR-115-CG | SOURCE-RAY, INC. |
27 | 00867538000304 | UC-5000 | 900117 | Mobile X-Ray System for General Purpose Radiography Exams Utilizing Film, Comput Mobile X-Ray System for General Purpose Radiography Exams Utilizing Film, Computed Radiography, or Direct Digital Flat Panels | UC-5000 | SOURCE-RAY, INC. |
28 | 00860290000360 | 11020 | xCAT IQ | XORAN TECHNOLOGIES LLC | ||
29 | 00860290000346 | 11010 | xCAT XL | XORAN TECHNOLOGIES LLC | ||
30 | 00860290000339 | 11000 | xCAT | XORAN TECHNOLOGIES LLC | ||
31 | 00860008892751 | ACSY-S009 | Micro C Load Bearing Cassette Plate, ACSY-S009 | OXOS MEDICAL, INC. | ||
32 | 00860001123470 | ACSY-S021 | OXBox | OXOS MEDICAL, INC. | ||
33 | 00860001123432 | ACSY-P036 | Micro C Medical Imaging System, M01 Foot Pedal | OXOS MEDICAL, INC. | ||
34 | 00860001123401 | M01 | Micro C Medical Imaging System, M01 | OXOS MEDICAL, INC. | ||
35 | 00858846007253 | TR90BH | The TR90BH is a portable X-ray system with following limitations of use: The de The TR90BH is a portable X-ray system with following limitations of use: The device may be used for handheld diagnostic imaging of body extremities The device may be used for stand mounted diagnostic imaging of head, abdomen, or extremities. The device may be used for stand mounted imaging of the chest when used without a grid. - Not to be used on bariatric patients, unless imaging body extremities - Not for mammography use - The TR90BH is not intended to replace a stationary radiographic system, which may be required for full optimization of image quality and radiation exposure for different exam types. | MinXray | MINXRAY, INC. | |
36 | 00858846007246 | HFP24 Podiatric X-ray unit | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This is a podiatric mono-block type high frequency portable x-ray unit. The unit can be used with conventional diagnostic film or with solid-state digital radiographic sensors | MinXray | MINXRAY, INC. | |
37 | 00858846007239 | HFP40 Portable X-ray unit | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This is a mono-block type high frequency portable x-ray unit. The unit can be used with conventional diagnostic film or with solid-state digital radiographic sensors. | MinXray | MINXRAY, INC. | |
38 | 00858846007222 | CMDR.TW.1202.R | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
39 | 00858846007215 | CMDR.PE.1202.S | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
40 | 00858846007208 | CMDR.PE.120.60.S | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
41 | 00858846007192 | CMDR.TW.120.60.R | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
42 | 00858846007185 | CMDR.PE.100.R | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
43 | 00858846007178 | Integris | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
44 | 00858846007161 | CMDR.PE.120.60.R | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
45 | 00858846007154 | CMDR.TW.120.60.S | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
46 | 00858846007147 | CMDR.T.100.S | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
47 | 00858846007130 | CMDR.TW.100.R | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
48 | 00858846007123 | CMDR.TW.1202.S | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
49 | 00858846007116 | CMDR.T.1202.R | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. | |
50 | 00858846007109 | CMDR.T.1202.S | This device is intended for use by a qualified/trained physician or technician o This device is intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammographic use. This device is a portable line operated diagnostic x-ray unit in combination with a digital x-ray receptor panel and PACS software. It can be used by hospitals, off-site radiography including mobile clinics, military field clinics and nursing homes. | MinXray | MINXRAY, INC. |