Other products from "MIND MEDIA B.V."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08719481550349 1.2 The NeXus-10 MKII is designed for medical use, not restricted to a specific medi The NeXus-10 MKII is designed for medical use, not restricted to a specific medical indication, for acquisition of (electro)-physiological signals (e.g. EEG, EMG or ECG). The product is intended to be used by medical/acces professionals in a laboratory setup or medical office, or to be set-up in such an environment after which the subject/patient can be sent out while signal acquisition continues on memory. The NeXus 10 MKII is not intended for use in diagnosis, nor in critical and/or life supporting applications.The NeXus 10 MKII is intended for use on humans.The NeXus 10 MKII is intended to be used with approved NeXus 10 MKII accessories only. Specifically, (active) sensors intended to measure specific physiological signals, shall be designed in accordance with the specifications of the NeXus-10 MKII and may require interpretation by user or application software. HCC Device, Biofeedback 2 NeXus-10 MKII
2 08719481550332 1.0.204.6 The NeXus software is intended to provide (near) real-time biofeedback and neuro The NeXus software is intended to provide (near) real-time biofeedback and neurofeedback in the form of information, visual and auditory signals, corresponding to the state of one or more physiological parameters, so that a patient can learn voluntary control of these parameters. The software shall be used on a personal computer (in a medical office environment) in combination with compatible signal acquisition devices and sensor accessories to perform its intended use. The software is designed for medical use, not restricted to a specific medical indication. It is intended to be used within a medical office environment by, or under supervision of, a health professional (novice user, technical knowledge, normal eyesight, possibly achieved with the aid of glasses). The software is not intended for use in a life support application nor is it intended for diagnostic purposes. HCC Device, Biofeedback 2 NeXus Software
3 08719481550035 1.0 NB-BVP-F (finger module):The BVP sensor provides a photoplethysmography (PPG) si NB-BVP-F (finger module):The BVP sensor provides a photoplethysmography (PPG) signal when connected to a NeXus signal acquisition device, that corresponds with variations in peripheral blood flow resulting from cardiovascular activity and responses, with the purpose of providing information on the cardiovascular variations such as heart rate variations and measured pulse amplitude. The sensor output is not intended to be used for vital monitoring purposes.The device is designed for medical use, not restricted to a specific medical indication, for acquisition of physiological signals. The device is intended to be used by, or under supervision of, a health professional within a clinical environment. HCC Device, Biofeedback 2 Blood Volume Pulse Sensor (NB-BVP-F)
4 08719481550042 1.0 NB-BVP-H (head module):The BVP sensor provides a photoplethysmography (PPG) sign NB-BVP-H (head module):The BVP sensor provides a photoplethysmography (PPG) signal when connected to a NeXus signal acquisition device, that corresponds with variations in peripheral blood flow resulting from cardiovascular activity and responses, with the purpose of providing information on the cardiovascular variations such as heart rate variations and measured pulse amplitude. The sensor output is not intended to be used for vital monitoring purposes.The device is designed for medical use, not restricted to a specific medical indication, for acquisition of physiological signals. The device is intended to be used by, or under supervision of, a health professional within a clinical environment. HCC Device, Biofeedback 2 Blood Volume Pulse Sensor (NB-BVP-H)
5 08719481550004 2.0 The NeXus-Q32 is intended for acquisition of (electro)-physiological signals (e. The NeXus-Q32 is intended for acquisition of (electro)-physiological signals (e.g. EEG, surface EMG or ECG) from humans, regardless of any specific medical indication, by medical/research professionals. HCC Device, Biofeedback 2 NeXus-Q32
6 08719481550073 1.0 NB-GSR:The GSR sensor provides a measure of skin resistance or skin conductance NB-GSR:The GSR sensor provides a measure of skin resistance or skin conductance when connected to a NeXus signal acquisition device, which is influenced by the autonomic activation of sweat glands in the skin. The sensor output is not intended to be used for vital monitoring purposes.The device is designed for medical use, not restricted to a specific medical indication, for acquisition of physiological signals. The device is intended to be used by, or under supervision of, a health professional within a clinical environment. HCC Device, Biofeedback 2 Galvanic Skin Response Sensor (NB-GSR)
7 08719481550097 1.0 NC-C-GT:The GSR sensor provides a measure of skin resistance or skin conductance NC-C-GT:The GSR sensor provides a measure of skin resistance or skin conductance when connected to a NeXus signal acquisition device, which is influenced by the autonomic activation of sweat glands in the skin. The sensor output is not intended to be used for vital monitoring purposes.The temperature sensor provides a signal that corresponds with (variations in) peripheral skin temperature when connected to a NeXus signal acquisition device. The sensor shall be placed on intact skin to provide a signal that is influenced by cutaneous blood flow. The sensor is not intended to determine directly or indirectly a measure of core body temperature and to be used for vital monitoring purposes.The device is designed for medical use, not restricted to a specific medical indication, for acquisition of physiological signals. The device is intended to be used by, or under supervision of, a health professional within a clinical environment. HCC Device, Biofeedback 2 GSR-TMP Combination Sensor (NC-C-GT)
8 08719481550066 1.0 NC-BVP-H (head module):The BVP sensor provides a photoplethysmography (PPG) sign NC-BVP-H (head module):The BVP sensor provides a photoplethysmography (PPG) signal when connected to a NeXus signal acquisition device, that corresponds with variations in peripheral blood flow resulting from cardiovascular activity and responses, with the purpose of providing information on the cardiovascular variations such as heart rate variations and measured pulse amplitude. The sensor output is not intended to be used for vital monitoring purposes.The device is designed for medical use, not restricted to a specific medical indication, for acquisition of physiological signals. The device is intended to be used by, or under supervision of, a health professional within a clinical environment. HCC Device, Biofeedback 2 Blood Volume Pulse Sensor (NC-BVP-H)
9 08719481550080 1.0 NB-TMP:The temperature sensor provides a signal that corresponds with (variation NB-TMP:The temperature sensor provides a signal that corresponds with (variations in) peripheral skin temperature when connected to a NeXus signal acquisition device. The sensor shall be placed on intact skin to provide a signal that is influenced by cutaneous blood flow. The sensor is not intended to determine directly or indirectly a measure of core body temperature and to be used for vital monitoring purposes.The device is designed for medical use, not restricted to a specific medical indication, for acquisition of physiological signals. The device is intended to be used by, or under supervision of, a health professional within a clinical environment. HCC Device, Biofeedback 2 Temperature Sensor (NB-TMP)
Other products with the same Product Code "HCC"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00816271020322 272CASE Dual EMG Wet Gel Ag/AgCl Electrode Case200 pcs per case Dual EMG Wet Gel Ag/AgCl Electrode NORAXON U.S.A., INC.
2 00816271020292 548 Telemyo Research DTS EMG TeleMyo NORAXON U.S.A., INC.
3 00816271020278 881 Ultium Analog Output Ultium NORAXON U.S.A., INC.
4 00816271020230 883 Ultium EMG Sensor Charging Station Ultium NORAXON U.S.A., INC.
5 00816271020223 810 Ultium EMG Sensor Ultium NORAXON U.S.A., INC.
6 00816271020216 880 Ultium EMG Receiver Ultium NORAXON U.S.A., INC.
7 00816271020155 587 Telemyo DTS Desktop Receiver (W/O Analog Out) TeleMyo NORAXON U.S.A., INC.
8 00816271020148 585 Telemyo Mini Receiver TeleMyo NORAXON U.S.A., INC.
9 00816271020131 584 Telemyo Clinical DTS Receiver TeleMyo NORAXON U.S.A., INC.
10 00816271020124 586 Telemyo DTS Desktop Receiver TeleMyo NORAXON U.S.A., INC.
11 00816271020117 580 Telemyo DTS Belt Receiver TeleMyo NORAXON U.S.A., INC.
12 00816271020100 548 Telemyo Research DTS EMG Lossless TeleMyo NORAXON U.S.A., INC.
13 00816271020094 546 Telemyo Clinical DTS EMG Telemyo NORAXON U.S.A., INC.
14 00816271020087 542 Telemyo DTS EMG TeleMyo NORAXON U.S.A., INC.
15 00816271020063 290 TeleMyo Sensor Charger TeleMyo NORAXON U.S.A., INC.
16 00816271020056 293 Telemyo PC-Interface TeleMyo NORAXON U.S.A., INC.
17 00816271020049 290 Telemyo 2400T G2 TeleMyo NORAXON U.S.A., INC.
18 D792N9600A0 Muscle Tester Noromed computerized manual muscle testing offers manual muscle testing at its b Noromed computerized manual muscle testing offers manual muscle testing at its best by bringing science to what once was an art.The muscle testing hardware includes an ergonomic force gauge and five attachments to choose from which provide easy, comfortable testing of all muscle groups - large and small. Now you can perform real time strength testing - quickly and easily - and all fully documented by the computer interface.The flexibility of the system allows you to use pre-programmed established protocols or create your own. Designed to meet your needs, the software calculates the statistics appropriate to each test as well as generating a wide variety of documentation to fit your specific needs. This documentation includes:Supportive documentation reports which contain the graphic reports and profiles of the actual test data. Reports included are:•A composite report of individual test results by protocol and muscles tested as well as calculated deficits. •A test comparison report which collects and displays the patient's historical results. •A Myotest data report which presents both statistical data and graphical data of the individual test broken down by trial. MES 9000 Muscle Tester MYOTRONICS NOROMED, INC
19 D792N9200A0 MES 9000 EMG The Dynamic SEMG module of the MES 9000 allows for the recording of up to 8 chan The Dynamic SEMG module of the MES 9000 allows for the recording of up to 8 channels of SEMG simultaneously. The MES 9000 offers you the flexibility to monitor and record the data in its raw state or as integrated data.The powerful and user-friendly software simplifies the recording of multiple muscle groups of antagonist and synergist muscles to facilitate assessment and case documentation. In addition, the system includes pre-programmed protocols and analysis for assessment, muscle education and relaxation training. The clinician may also program custom protocols - quickly and simply. MES 9000 Dynamic EMG MYOTRONICS NOROMED, INC
20 D792N9000M0 N9000M Now you can have all of these capabilities in one compact system. Surface EMG, r Now you can have all of these capabilities in one compact system. Surface EMG, rangeof motion and muscle testing – may be purchased separately or in any combination. The modulardesign of the MES 9000 allows you to purchase any combination of modules and expand as yourpractice grows. The MES 9000 --- the modular system that enables you to do a complete, integratedevaluation with objective documentation that supports your diagnosis. MES 9000 Musculoskeletal System MYOTRONICS NOROMED, INC
21 D792N36010 NT360 By using sophisticated sensors within the inclinometers, the Dynamic ROM system By using sophisticated sensors within the inclinometers, the Dynamic ROM system records the patient's entire ROM through the plane of movement and displays it in a graphical representation on the computer screen. Unlike other systems which simply give you a static endpoint measurement of ROM, Dynamic ROM captures the entire movement. The figure to your left shows a typical Dynamic ROM recording of the dynamic motion of the spine during three repetitions of lumbar flexion and extension. The numbers correspond with the figure to the left showing the patient's motions.The inclinometers are attached to straps placed over T12 and S1. The recording of the sensor at S1 is subtracted from the recording at T12 to produce the DIFFerential recording graph which represents the true motion of the patient's lumbar during lumbar flexion and extension motion. The flattened DIFF tracing line on each repetition during end-point indicates that both sensors are moving at the same rate of speed, and that the lumbar lordosis stopped unfolding before the end-point of trunk flexion had been reached. With this information the clinician can observe and assess the quality and the pattern of the patient's motion as well as the quantity of the ROM. Dynamic Range of Motion from Noromed elevates range of motion testing from a simple measurement tool to a true diagnostic tool. Noromed NT-360 Inclinometer MYOTRONICS NOROMED, INC
22 D792N150MES0 Static EMG Scanner Noromed SEMG, with broader operating ranges, greater sensitivity, and unsurpasse Noromed SEMG, with broader operating ranges, greater sensitivity, and unsurpassed ability to eliminate extraneous electrical "noise", provides an SEMG platform you can use with confidence. With Noromed SEMG you know you are getting true, reliable and repeatable results.In evaluating the technological sophistication, superiority and reliability of SEMG systems, the most important factors are sensitivity (usually expressed in microvolts), the monitoring range (again usually expressed in microvolts), and how the instrument eliminates ambient electrical noise. MES 9000 Static Electromyography Scanner MYOTRONICS NOROMED, INC
23 00190446163985 5923-3 VITALSTIM PLUS ELECTROTHERAPY SYSTEM CHATTANOOGA DJO, LLC
24 00092237623817 DQ2000 TheraTouch UX2 Stand Alone Ultrasound TheraTouch UX2 COMPASS HEALTH BRANDS CORP.
25 00082161071051 07105 Pressure monitoring insole Intellinetix BROWNMED, INC.
26 B7580356300000000000001 30Min-DAP 0356-30 Single use disposable application pad adhesive for use with dorsaVi Version 5 MD Single use disposable application pad adhesive for use with dorsaVi Version 5 MDM Sensors for Movement Suite Kits. 30 Minute Disposable Application Pad DORSAVI LTD
27 B7580000VMV50000000000 0000VMV50000000000 VMV50 Movement Suite is a wireless medical device that measures, records, and reports Movement Suite is a wireless medical device that measures, records, and reports movements and muscle activity of the lowerback / lumbar spine. The system also measures range of motion in the sagittal and coronal anatomical planes. Movement Suite / V5 Sensor Kit DORSAVI LTD
28 B7580000RDA482000000000 V6 Sensor Adhesive RS-A482 Single use disposable application pad adhesive for use with dorsaVi Version 6 Sensors. dorsaVi DORSAVI LTD
29 B7580000PS100000000000 0000PS100000000000 PS100 Professional Suite is a wireless medical device that measures, records, and repo Professional Suite is a wireless medical device that measures, records, and reports movements and muscle activity of the lowerback / lumbar spine. The system also measures range of motion in the sagittal and coronal anatomical planes. Professional Suite DORSAVI LTD
30 B58804E0 A404 EEG Amplifier Phoenix EEG Amplifier SOUTHEAST SIGNAL, INC
31 B58802L0 A200 EEG Amplifier Ochs Labs EEG Amplifier SOUTHEAST SIGNAL, INC
32 B58802E0 A202 EEG Amplifier Phoenix EEG Amplifier SOUTHEAST SIGNAL, INC
33 B258EEGER4 4 Neurofeedback Software EEGer4 EEG SOFTWARE LLC
34 B184A100020 A10002 A10002 NTrainer System NTrainer INNARA HEALTH, INC.
35 B184A000020 A00002 A00002 NTrainer System NTrainer INNARA HEALTH, INC.
36 B179TMJ 1.0 BTSEMB1BM BTS TMJOINT is a wireless surface electromyograph to measure thedifferential in BTS TMJOINT is a wireless surface electromyograph to measure thedifferential influence of the occlusal function through indices validatedand published in scientific literature TMJOINT BTS SPA
37 B179OMN 1.0 BTSEMB1BM BTS OMNIsEMG is an instrument for the electromyographic surface analysis. OMNIsEMG BTS SPA
38 B179GSN2 2 BTSGSN2 BTS G-SENSOR 2 is a wireless system consisting of an inertial sensor composed by BTS G-SENSOR 2 is a wireless system consisting of an inertial sensor composed by a tri-axial accelerometer, a magnetic sensor, and a tri-axial gyroscope, that worn by the patient allows a functional gait analysis. G-SENSOR BTS SPA
39 B179FR1 1000 BTSEMB1BM BTS FREEEMG 1000 is a wireless surface electromyograph for the acquisition and t BTS FREEEMG 1000 is a wireless surface electromyograph for the acquisition and transmission of EMG signals and for the assessment of angles, angular velocities, angular accelerations and foot-floor contact areas.It allows the functional evaluation and a real-time visualization of the acquired signals for biofeedback and monitoring applications. FREEEMG BTS SPA
40 B179FE3 300 BTSFE3 BTS FREEEMG 300 is a wireless surface electromyograph, which makes the selection BTS FREEEMG 300 is a wireless surface electromyograph, which makes the selection of muscles, the setting ofduration and frequency of acquisition, amplification gain and the correctpositioning of electrodes, simple and rapid. FREEEMG BTS SPA
41 B179BAIO1 1 BAIOBIT is a wireless system consisting of an inertial sensor composed by a tri- BAIOBIT is a wireless system consisting of an inertial sensor composed by a tri-axial accelerometer, a magnetic sensor, and a tri-axial gyroscope, that worn by the patient allows a functional movement analysis. baiobit BTS SPA
42 09413000078510 Android 100321 Neurofeedback Software Application for Android Axon EXSURGO LIMITED
43 09413000078459 Large 100161 EEG Biofeedback (Neurofeedback) Kit - Largeincludes Axon EEG headset - Large, Ta EEG Biofeedback (Neurofeedback) Kit - Largeincludes Axon EEG headset - Large, Tablet with Axon Neurofeedback Software Application Axon EXSURGO LIMITED
44 09413000078442 Medium 100160 Neurofeedback Kit - Mediumincludes Axon EEG headset - Medium, Tablet with Axon N Neurofeedback Kit - Mediumincludes Axon EEG headset - Medium, Tablet with Axon Neurofeedback Software Application Axon EXSURGO LIMITED
45 09413000078435 Small 100140 Neurofeedback Kit - Smallincludes Axon EEG headset - Small, Tablet with Axon Neu Neurofeedback Kit - Smallincludes Axon EEG headset - Small, Tablet with Axon Neurofeedback Software Application Axon EXSURGO LIMITED
46 09413000078428 Large 100143 EEG Headset - Large Axon EXSURGO LIMITED
47 09413000078411 Small 100141 EEG Headset - Small Axon EXSURGO LIMITED
48 09413000077094 Medium 100142 EEG Headset - Medium Axon EXSURGO LIMITED
49 08809475370012 MAW2017 Make a Way ECG Monitor MAKE A WAY CO.,LTD.
50 08809475370005 BBSMT01 Make a Way PREGNANT WOMEN & FETAL HEALTH MONITOR MAKE A WAY CO.,LTD.