A Dome, Male/Male 36" Pressure Tubing and 2 x 4-Way stopcocks. A separately pack
A Dome, Male/Male 36" Pressure Tubing and 2 x 4-Way stopcocks. A separately packed male protective caps.
A standalone 60 drops, 60" tube 1-way Adset packs with a Critiflo assembled with
A standalone 60 drops, 60" tube 1-way Adset packs with a Critiflo assembled with Velcro strap & Adhesive pad. It is connected to a 3-way OFF white stopcock and a 12' Female/ Male Pressure tubing. It also includes a separately packed 2x male protective caps.
60 drops, 60" tube AdSet packs with a Critiflo device connected to 3-Way OFF st
60 drops, 60" tube AdSet packs with a Critiflo device connected to 3-Way OFF stopcock & a 12" Pressure Tubing. It also includes a separately packed 2x male protective caps and a colour label set.
A separate 60 drops,60" tube Adset and a Critiflo flushing device connected to a
A separate 60 drops,60" tube Adset and a Critiflo flushing device connected to a 3-Way White OFF stopcock, Pressure tubing of length 48", 3-Way White OFF stopcock and 12" Pressure tubing. It also includes a separately packed 2x male protective caps.
60 drops, 60" tube length AdSet packs with a Critiflo Dome device connected with
60 drops, 60" tube length AdSet packs with a Critiflo Dome device connected with a 60" & 12" pressure Tubing & a 3-way White OFF stopcock. It also includes a separately packed 2x male protective caps.
A separate 60 drops, 60" tube Adset packs with a Critiflo dome set connected to
A separate 60 drops, 60" tube Adset packs with a Critiflo dome set connected to pressure tubing and 2x 3-Way White Off stopcocks. It also includes a separately packed 2x male protective caps.
60 drops, 60" tube length AdSet packs with a Critiflo Dome connected with a 36"
60 drops, 60" tube length AdSet packs with a Critiflo Dome connected with a 36" pressure Tubing & a 3-way White stopcock. It also includes a separately packed 2x male protective caps.
60 drops, 60" tube length AdSet packed together with a Critiflo connected with a
60 drops, 60" tube length AdSet packed together with a Critiflo connected with a 48" & 12" pressure Tubing and stopcock
Mikro-Tip catheters consist of an ultra-miniature pressure sensor(s) at the dist
Mikro-Tip catheters consist of an ultra-miniature pressure sensor(s) at the distal end of a catheter with an electrical connector(s) at the proximal end. The pressure sensor produces an electrical output signal, which varies in direct proportion to the magnitude of sensed pressure or sound. Mikro-Tip catheters are intended for multiple uses.
The TC-510 Pressure Control Unit is a passive interface between the pressure sen
The TC-510 Pressure Control Unit is a passive interface between the pressure sensor of anystandardized sensitivity Mikro-Tip® catheter and strain gauge pressure monitors or recordingsystems which supply bridge excitation voltage and have balance and calibration controls forfull-bridge strain gauge pressure transducers.The TC-510 contains circuitry which facilitates monitor setup. In the STANDBY (0) positionthe TC-510 provides an electrical zero. In the 100 mmHg (13.3 kPa) position the TC-510provides a signal equal to 100 mmHg (13.3 kPa) at a sensitivity of 5 μV/V/mmHg. Thetransducer is operational in the TRANSDUCER position and the TRANSDUCER BALANCEcontrol allows balancing of the transducer
The Millar Mikro-Cath Cardiovascular Catheter is fitted with an ultra-miniature
The Millar Mikro-Cath Cardiovascular Catheter is fitted with an ultra-miniature pressure sensor near the distal end. The sensor is side mounted at the catheter tip. The proximal end terminates in a connector. The pressure sensor produces an electrical output signal which varies in direct proportion to the magnitude of sensed pressure or sound.
The Endophys Pressure Sensing Sheath Kit is comprised of an introducer sheath wi
The Endophys Pressure Sensing Sheath Kit is comprised of an introducer sheath with an integrated fiber optic pressure transducer,a vessel dilator and guidewire. Used in conjunction with the Endophys Blood Pressure Monitor it is used to continuously monitor patient blood pressure during procedure requiring vascular access.
The Endophys Pressure Sensing Sheath Kit is comprised of an introducer sheath wi
The Endophys Pressure Sensing Sheath Kit is comprised of an introducer sheath with an integrated fiber optic pressure transducer,a vessel dilator and guidewire. Used in conjunction with the Endophys Blood Pressure Monitor it is used to continuously monitor patient blood pressure during procedure requiring vascular access.
The OmniWire pressure guide wire is indicated for use to measure pressure in blo
The OmniWire pressure guide wire is indicated for use to measure pressure in blood vessels, including both coronary and peripheral vessels, during diagnostic angiography and/or any interventional procedures. It can also be used to facilitate the placement of catheters as well as other interventional devices in coronary and peripheral vessels. Blood pressure measurements provide hemodynamic information for the diagnosis and treatment of blood vessel disease.
The OmniWire pressure guide wire is indicated for use to measure pressure in blo
The OmniWire pressure guide wire is indicated for use to measure pressure in blood vessels, including both coronary and peripheral vessels, during diagnostic angiography and/or any interventional procedures. It can also be used to facilitate the placement of catheters as well as other interventional devices in coronary and peripheral vessels. Blood pressure measurements provide hemodynamic information for the diagnosis and treatment of blood vessel disease.