The Celiac Disease IgA Calibrators include antibodies to tTG and DGP.1. Aptiva C
The Celiac Disease IgA Calibrators include antibodies to tTG and DGP.1. Aptiva Celiac IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives. 2. Aptiva Celiac IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives.3. Aptiva Celiac IgA Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives.
1. QUANTA Flash RF IgM Negative Control: Two (2) barcode labeled tubes containin
1. QUANTA Flash RF IgM Negative Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to RF IgM in stabilizers and preservatives.2. QUANTA Flash RF IgM Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to RF IgM in stabilizers and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash aCL IgM Low Control 3 x 1 mL barcoded tubes of a solution with a
1. QUANTA Flash aCL IgM Low Control 3 x 1 mL barcoded tubes of a solution with aCL IgM in saline solution containing fetal bovine serum stabilizers and preservative.2. QUANTA Flash aCL IgM High Control 3 x 1 mL barcoded tubes of a solution with aCL IgM in saline solution containing fetal bovine serum, stabilizers and preservative.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.2. QUANTA Flash LKM-1 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.3. QUANTA Flash LKM-1 Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.
1. QUANTA Flash M2 (MIT3) Negative Control: Two (2) barcode labeled tubes contai
1. QUANTA Flash M2 (MIT3) Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to M2 (MIT3) in stabilizers and preservatives.2. QUANTA Flash M2 (MIT3) Positive Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to M2 (MIT3) in stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing
1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.2. QUANTA Flash M2 (MIT3) Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.3. QUANTA Flash M2 (MIT3) Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 10 bottles containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgG ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 GPS U/mL. Ready to use.7. Phosphatidylserine IgG Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9.HRP Phosphatidylserine IgG Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgG. Coloured red, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use.
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 10 bottles containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgM ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 GPS U/mL. Ready to use.7. Phosphatidylserine IgM Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP Phosphatidylserine IgM Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgM. Coloured blue, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use.
1. QUANTA Flash h-tTG IgG Negative Control: Two (2) barcode labeled tubes contai
1. QUANTA Flash h-tTG IgG Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to h-tTG in stabilizers and preservatives.2. QUANTA Flash h-tTG IgG Positive Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to h-tTG in stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, 5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgG Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgG autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. 7. R h-tTG IgG Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 9. HRP R h-tTG IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. 10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. 11. Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid.
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating t
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgA Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgA autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. 7.R h-tTG IgA Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 8.ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate..9. HRP R h-tTG IgA Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgA. Colored yellow. 10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen.11.Stop Solution HRP: 1 bottle containing 10mL of 0.344M Sulfuric Acid.
1. QUANTA Flash h-tTG IgA Calibrator 1: Two (2) barcode labeled tubes containing
1. QUANTA Flash h-tTG IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to h-tTG in stabilizers and preservatives. 2. QUANTA Flash h-tTG IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to h-tTG in stabilizers and preservatives.
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating t
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgA Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgA autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7.R h-tTG IgA Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.8.ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP R h-tTG IgA Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgA. Colored yellow. Ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.11.Stop Solution HRP: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use.
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgG Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgG autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7. R h-tTG IgG Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP R h-tTG IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.11. Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use.
1.Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating t
1.Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. dsDNA SC Coated Wells: 12 breakapart 8 well strips coated with calf thymus dsDNA antigen. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.5. dsDNA SC Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-dsDNA autoantibody: 1000, 333, 111, 37, 12.3 IU/mL. Ready to use.6. dsDNA SC Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.7. Type III Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored yellow, ready to use.8. HRP Wash Concentrate (40X): 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.9.dsDNA SC Single Stranded Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.10. HRP dsDNA SC IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use.11. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.12. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use.
LRM
Anti-Dna Antibody (Enzyme-Labeled), Antigen, Control
1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.
1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives.2. QUANTA Flash RF IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives.
1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives. 2. QUANTA Flash Ro52 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives.
1. QUANTA Flash Centromere Negative Control: Two (2) barcode labeled tubes conta
1. QUANTA Flash Centromere Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to centromere in buffer, stabilizers, and preservatives.2. QUANTA Flash Centromere Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to centromere in buffer, stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash ß2GP1 IgM Low Control 3 x 1 mL barcoded tubes of a solution with
1. QUANTA Flash ß2GP1 IgM Low Control 3 x 1 mL barcoded tubes of a solution with anti-ß2GP1 IgM in phosphate buffer containing bovine serum albimun, stabilizers and preservative.2. QUANTA Flash ß2GP1 IgM High Control 3 x 1 mL barcoded tubes of a solution with anti-ß2GP1 IgM in phosphate buffer containing bovine serum albumin, stabilizers and preservative.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. MPO SC Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with MPO antigen, colour coded green. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. Type III Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured yellow, ready to use.5. HRP Wash Concentrate: 10 bottles containing 25mL of a 40-fold concentrated buffer for washing the wells. 6. MPO SC ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-MPO autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7.MPO SC Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP MPO SC IgG Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgG. Coloured blue, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11.HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use.
MOB
Test System, Antineutrophil Cytoplasmic Antibodies (Anca)
1. 5 x 12-well HEp-2 Substrate Slides2. 1 x 4mL FITC Anti-Human IgG Conjugate3.
1. 5 x 12-well HEp-2 Substrate Slides2. 1 x 4mL FITC Anti-Human IgG Conjugate3. 1 x 0.5 mL ANA Titratable Endpoint Pattern Control4. 1 x 0.5mL IFA System Negative Control5. 1 x 25mL PBS II Concentrate (40x)6. 1 x 7mL Mounting Medium7. 1 x 20 Coverslips
LLL
Extractable Antinuclear Antibody, Antigen And Control
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 1 bottle containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgM ELISA Calibrators: 5 bottles each containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 MPS U/mL. Ready to use.7. Phosphatidylserine IgM Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP Phosphatidylserine IgM Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgM. Coloured blue, ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric acid. Ready to use.
1. QUANTA Flash DGP IgA Calibrator 1: Two (2) barcode labeled tubes containing 0
1. QUANTA Flash DGP IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to DGP in buffer, protein stabilizers, and preservatives. 2. QUANTA Flash DGP IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to DGP in buffer, protein stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash PR3 Negative Control: Two (2) barcode labeled tubes with buffer
1. QUANTA Flash PR3 Negative Control: Two (2) barcode labeled tubes with buffer containing human serum antibodies to PR3, prediluted, ready to use, 0.5mL (containing buffer, protein stabilizers, and preservatives).2. QUANTA Flash PR3 Positive Control: Two (2) barcode labeled tubes with buffer containing human serum antibodies to PR3, prediluted, ready to use, 0.5mL (containing buffer, protein stabilizers, and preservatives).
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
The lypholised Hemoglobin A1c Linearity controls are prepared from human blood a
The lypholised Hemoglobin A1c Linearity controls are prepared from human blood and contain normal hemoglobin, preservatives and stabilizers. The controls are formulated to give enhanced stability.The Lyophilized Hemoglobin A1c Linearity Controls are intended to verify the linearity of HbA1c assays across the patient reportable range (4 to 18%, NGSP aligned) using protocols setup within individual clinical laboratories.
The liquid Hemoglobin A1c Control kit contains 12 vials each of level 1 and leve
The liquid Hemoglobin A1c Control kit contains 12 vials each of level 1 and level 2 controls which are prepared as a stabilized hemolysate from human blood. The controls are designed for use as quality control materials to monitor the accuracy and precision of laboratory testing procedures.
The lypholised Hemoglobin A1c Linearity kit contains 1 vial each of level 1, 2,
The lypholised Hemoglobin A1c Linearity kit contains 1 vial each of level 1, 2, 3, 4 and 5 controls which are prepared as a stabilized hemolysate from human blood. The controls are designed for use as quality control materials to monitor the accuracy and precision of laboratory testing procedures.
The lypholised Hemoglobin A1c Control kit contains 4 vials each of level 1 and l
The lypholised Hemoglobin A1c Control kit contains 4 vials each of level 1 and level 2 controls which are prepared as a stabilized hemolysate from human blood. The controls are designed for use as quality control materials to monitor the accuracy and precision of laboratory testing procedures.
The liquid Hemoglobin A1c Control kit contains 2 vials each of level 1 and level
The liquid Hemoglobin A1c Control kit contains 2 vials each of level 1 and level 2 controls which are prepared as a stabilized hemolysate from human blood. The controls are designed for use as quality control materials to monitor the accuracy and precision of laboratory testing procedures.
FREND™ TSH Linearity Kit is intended for use as an assayed linearity material fo
FREND™ TSH Linearity Kit is intended for use as an assayed linearity material for the thyroid stimulating hormone (TSH) on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ TSH Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
FREND™ TSH Linearity Kit is intended for use as an assayed linearity material fo
FREND™ TSH Linearity Kit is intended for use as an assayed linearity material for the thyroid stimulating hormone (TSH) on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ TSH Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
FREND™ Testosterone Linearity Kit is intended for use as an assayed linearity ma
FREND™ Testosterone Linearity Kit is intended for use as an assayed linearity material for the testosterone on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ Testosterone Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution
FREND™ PSA Plus Linearity Kit is intended for use as an assayed linearity materi
FREND™ PSA Plus Linearity Kit is intended for use as an assayed linearity material for the prostate-specific antigen (PSA) on the FREND™ System. The Linearity kit is for the FREND™ System only.FREND™ PSA Plus Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
FREND™ Free T4 Linearity Kit is intended for use as an assayed linearity materia
FREND™ Free T4 Linearity Kit is intended for use as an assayed linearity material for the free thyroxine (Free T4) on the FREND™ System. The Linearity Kit is for the FREND™ System only.FREND™ Free T4 Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.