No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08430793040570 724121 The Celiac Disease IgA Calibrators include antibodies to tTG and DGP.1. Aptiva C The Celiac Disease IgA Calibrators include antibodies to tTG and DGP.1. Aptiva Celiac IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives. 2. Aptiva Celiac IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives.3. Aptiva Celiac IgA Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives. JIX Calibrator, Multi-Analyte Mixture 2 Aptiva® Celiac Disease IgA Calibrators
2 08426950845263 701342 1. QUANTA Flash RF IgM Negative Control: Two (2) barcode labeled tubes containin 1. QUANTA Flash RF IgM Negative Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to RF IgM in stabilizers and preservatives.2. QUANTA Flash RF IgM Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to RF IgM in stabilizers and preservatives. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash RF IgM Controls
3 08426950594994 701237 1. QUANTA Flash aCL IgM Low Control 3 x 1 mL barcoded tubes of a solution with a 1. QUANTA Flash aCL IgM Low Control 3 x 1 mL barcoded tubes of a solution with aCL IgM in saline solution containing fetal bovine serum stabilizers and preservative.2. QUANTA Flash aCL IgM High Control 3 x 1 mL barcoded tubes of a solution with aCL IgM in saline solution containing fetal bovine serum, stabilizers and preservative. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® aCL IgM Controls
4 08426950793175 701332 1. QUANTA Flash HMGCR Negative Control: Two (2) barcode labeled tubes containing 1. QUANTA Flash HMGCR Negative Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to HMGCR in stabilizers and preservatives.2. QUANTA Flash HMGCR Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to HMGCR in stabilizers and preservatives. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® HMGCR Controls
5 08426950766988 701296 1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.2. QUANTA Flash LKM-1 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.3. QUANTA Flash LKM-1 Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives. JIT Calibrator, Secondary 2 QUANTA Flash® Lkm-1 Calibrators
6 08426950730095 701302 1. QUANTA Flash M2 (MIT3) Negative Control: Two (2) barcode labeled tubes contai 1. QUANTA Flash M2 (MIT3) Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to M2 (MIT3) in stabilizers and preservatives.2. QUANTA Flash M2 (MIT3) Positive Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to M2 (MIT3) in stabilizers, and preservatives. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® M2 (MIT3) Controls
7 08426950729938 701301 1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing 1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.2. QUANTA Flash M2 (MIT3) Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.3. QUANTA Flash M2 (MIT3) Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives. JIT Calibrator, Secondary 2 QUANTA Flash® M2 (MIT3) Calibrators
8 08426950622208 701125 1. 1 QUANTA Flash CCP3 Reagent Cartridge2. 1 Resuspension Buffer 63. 1 Transfer pipet NHX Antibodies, Anti-Cyclic Citrullinated Peptide (Ccp) 2 QUANTA Flash® CCP3 Reagents
9 08426950602118 708300 "1 .20x ANCA (Formalin Fixed Human Neutrophil), slides - 12 wells2. 1x 15mL FITC "1 .20x ANCA (Formalin Fixed Human Neutrophil), slides - 12 wells2. 1x 15mL FITC IgG Conjugate with DAPI 3. 1x 0.5 mL cANCA Positive4. 1x 0.5 mL pANCA Positive 5. 1x 0.5mL IFA System Negative Control6. 2x25mL PBS II Concentrate (40x)8. 1x 7mL Mounting Medium9. 1x 20 Coverslips10. 1x Direction Insert" MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 NOVA Lite® ANCA (Formalin) Kit with DAPI
10 08426950601890 701100 1. 1 QUANTA Flash h-tTG IgA reagent cartridge2. 1 Resuspension buffer 3. 1 Transfer pipet MVM Autoantibodies, Endomysial(Tissue Transglutaminase) 2 QUANTA Flash® h-tTG IgA Reagents
11 08426950595670 704625.10 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 10 bottles containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgG ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 GPS U/mL. Ready to use.7. Phosphatidylserine IgG Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9.HRP Phosphatidylserine IgG Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgG. Coloured red, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use. MID System, Test, Anticardiolipin Immunological 2 QUANTA Lite® Phosphatidylserine IgG ELISA Bulk Pack
12 08426950595151 701118 1. 1 QUANTA Flash RNP Reagent Cartridge2. 1 Resuspension buffer 3. 1 Transfer pipet LKO Anti-Rnp Antibody, Antigen And Control 2 QUANTA Flash® RNP Reagents
13 08426950594901 704630.10 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 10 bottles containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgM ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 GPS U/mL. Ready to use.7. Phosphatidylserine IgM Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP Phosphatidylserine IgM Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgM. Coloured blue, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use. MID System, Test, Anticardiolipin Immunological 2 QUANTA Lite® Phosphatidylserine IgM ELISA Bulk Pack
14 08426950594765 701107 1. QUANTA Flash h-tTG IgG Negative Control: Two (2) barcode labeled tubes contai 1. QUANTA Flash h-tTG IgG Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to h-tTG in stabilizers and preservatives.2. QUANTA Flash h-tTG IgG Positive Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to h-tTG in stabilizers, and preservatives. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® h-tTG IgG Controls
15 08426950593966 708415 1. 8 prepunched NOVA Gel titering ""T"" plates2. 2 0.4mL Sm/RNP antigen, lyophil 1. 8 prepunched NOVA Gel titering ""T"" plates2. 2 0.4mL Sm/RNP antigen, lyophilized3. 1 0.7mL Sm Control4. 1 0.7mL RNP Control LLL Extractable Antinuclear Antibody, Antigen And Control 2 NOVA Gel® Sm/RNP “T” Extractable Autoantibody Reagents
16 08426950593928 704610.10L 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, 5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgG Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgG autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. 7. R h-tTG IgG Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 9. HRP R h-tTG IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. 10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. 11. Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. MVM Autoantibodies, Endomysial(Tissue Transglutaminase) 2 QUANTA LITE® R h-tTG IgG ELISA Bulk Pack (Lab Corp)
17 08426950593560 704605.10L 1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating t 1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgA Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgA autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. 7.R h-tTG IgA Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 8.ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate..9. HRP R h-tTG IgA Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgA. Colored yellow. 10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen.11.Stop Solution HRP: 1 bottle containing 10mL of 0.344M Sulfuric Acid. MVM Autoantibodies, Endomysial(Tissue Transglutaminase) 2 QUANTA LITE® R h-tTG IgA ELISA Kit, Bulk (Lab Corp)
18 08426950554509 701101 1. QUANTA Flash h-tTG IgA Calibrator 1: Two (2) barcode labeled tubes containing 1. QUANTA Flash h-tTG IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to h-tTG in stabilizers and preservatives. 2. QUANTA Flash h-tTG IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to h-tTG in stabilizers and preservatives. JIX Calibrator, Multi-Analyte Mixture 2 QUANTA Flash® h-tTG IgA Calibrators
19 08426950544470 701103 1. 1 QUANTA Flash h-tTG IgA reagent cartridge2. 1 Resuspension buffer 3. 1 Transfer pipet MVM Autoantibodies, Endomysial(Tissue Transglutaminase) 2 QUANTA Flash® h-tTG IgA Reagents
20 08426950544463 704605 1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating t 1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgA Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgA autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7.R h-tTG IgA Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.8.ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP R h-tTG IgA Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgA. Colored yellow. Ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.11.Stop Solution HRP: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use. MVM Autoantibodies, Endomysial(Tissue Transglutaminase) 2 QUANTA Lite® R h-tTG IgA ELISA
21 08426950544241 704660 "1. Instruction leaflet: 2. QC Certificate3. PR3 SC Coated Wells: 12 breakapar "1. Instruction leaflet: 2. QC Certificate3. PR3 SC Coated Wells: 12 breakapart 8 well strips 4. Type III Sample Diluent: 2 bottles containing 50mL 5. HRP Wash Concentrate: 1 bottle containing 25mL6. PR3 SC ELISA Calibrators: 5 bottles each containing 1.2mL 7. PR3 SC Positive Control: 1 bottle containing 1.2mL 8. ELISA Negative Control: 1 bottle containing 1.2mL 9. HRP PR3 SC IgG Conjugate: 1 bottle containing 10mL 10. TMB Chromogen: 1 bottle containing 10mL 11. HRP Stop Solution: 1 bottle containing 10mL MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 QUANTA Lite® PR3 SC ELISA
22 08426950544142 704610 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgG Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgG autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7. R h-tTG IgG Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP R h-tTG IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.11. Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use. MVM Autoantibodies, Endomysial(Tissue Transglutaminase) 2 QUANTA Lite® R h-tTG IgG ELISA
23 08426950544111 704650 1.Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating t 1.Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. dsDNA SC Coated Wells: 12 breakapart 8 well strips coated with calf thymus dsDNA antigen. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.5. dsDNA SC Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-dsDNA autoantibody: 1000, 333, 111, 37, 12.3 IU/mL. Ready to use.6. dsDNA SC Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.7. Type III Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored yellow, ready to use.8. HRP Wash Concentrate (40X): 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.9.dsDNA SC Single Stranded Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.10. HRP dsDNA SC IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use.11. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.12. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use. LRM Anti-Dna Antibody (Enzyme-Labeled), Antigen, Control 2 QUANTA Lite® dsDNA SC ELISA
24 08426950472773 708625 1. 1x Cardiolipin ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL 1. 1x Cardiolipin ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL prediluted ACA Negative Control 3. 1x 1.2mL prediluted ACA IgG III Control4. 1x 1.2mL prediluted ACA IgG III Calibrator A5. 1x 1.2mL prediluted ACA IgG III Calibrator B6. 1x 1.2mL prediluted ACA IgG III Calibrator C7. 1x 1.2mL prediluted ACA IgG III Calibrator D8. 1x 1.2mL prediluted ACA IgG III Calibrator E9. 1x 50mL ACA III Sample Diluent10. 1x 50mL ACA III PBS Concentrate, 20x concentrate11. 1x 10mL HRP IgG Conjugate, (goat), anti-human IgG12. 1x 10mL TMB Chromogen13. 1x 10mL HRP Stop Solution, 0.344M Sulfuric Acid MID System, Test, Anticardiolipin Immunological 2 QUANTA Lite® ACA IgG III
25 08426950456186 708580 1. 1x Scl-70 ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL pred 1. 1x Scl-70 ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL prediluted ELISA Negative Control 3. 1x 1.2mL prediluted Scl-70 ELISA Low Positive4. 1x 1.2mL prediluted Scl-70 ELISA High Positive5. 1x 50mL HRP Sample Diluent 6. 1x 25mL HRP Wash Concentrate, 40x concentrate7. 1x 10mL HRP IgG Conjugate, (goat), anti-human IgG8. 1x 10mL TMB Chromogen9. 1x 10mL HRP Stop Solution, 0.344M Sulfuric Acid LLL Extractable Antinuclear Antibody, Antigen And Control 2 QUANTA Lite® Scl-70 ELISA
26 08426951289288 701225 1. 1 QUANTA Flash aCL IgA Reagent Cartridge2. 1 QUANTA Flash aCL IgA Calibrator 1. 1 QUANTA Flash aCL IgA Reagent Cartridge2. 1 QUANTA Flash aCL IgA Calibrator 1 3. 1 QUANTA Flash aCL IgA Calibrator 2 MID System, Test, Anticardiolipin Immunological 2 QUANTA Flash® aCL IgA Reagents
27 08426950928782 701352 1. QUANTA Flash Calprotectin Low Control: Two (2) barcode labeled tubes containi 1. QUANTA Flash Calprotectin Low Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain recombinant calprotectin with stabilizers and preservatives. 2. QUANTA Flash Calprotectin High Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain recombinant calprotectin with stabilizers and preservatives. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® Calprotectin Controls
28 08426950835196 701346 1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0. 1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives.2. QUANTA Flash RF IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives. JIT Calibrator, Secondary 2 QUANTA Flash RF IgA Calibrators
29 08426950627821 701255 1. 1 QUANTA Flash ENA7 Reagent Cartridge2. 1 Resuspension buffer3. 1 Transfer pipet" LLL Extractable Antinuclear Antibody, Antigen And Control 2 QUANTA Flash® ENA7 Reagents
30 08426950596813 701228 1 .1 QUANTA Flash aCL IgA Reagent Cartridge2.1 QUANTA Flash aCL IgA Calibrator 1 1 .1 QUANTA Flash aCL IgA Reagent Cartridge2.1 QUANTA Flash aCL IgA Calibrator 1 3.1 QUANTA Flash aCL IgA Calibrator 2 MID System, Test, Anticardiolipin Immunological 2 QUANTA Flash® aCL IgA Reagents
31 08426950596653 701261 1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives. 2. QUANTA Flash Ro52 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives. JIT Calibrator, Secondary 2 QUANTA Flash® Ro52 Calibrators
32 08426950596097 701197 1. QUANTA Flash Centromere Negative Control: Two (2) barcode labeled tubes conta 1. QUANTA Flash Centromere Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to centromere in buffer, stabilizers, and preservatives.2. QUANTA Flash Centromere Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to centromere in buffer, stabilizers, and preservatives. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® Centromere Controls
33 08426950595816 708665.10 1. 10 B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL pre 1. 10 B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL prediluted ELISA Negative Control 3. 5x 1.2mL prediluted 2 GPI IgG ELISA Control4. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator A5. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator B6. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator C7. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator D8. 1x 1.2mL prediluted 2 GPI IgG ELISA Calibrator E9. 9x 50mL HRP Sample Diluent10. 10x 25mL HRP Wash Concentrate, 40x concentrate11. 10x 10mL 2 HRP IgG Conjugate, (goat), anti-human IgG12. 10x 10mL TMB Chromogen13. 10x 10mL HRP Stop Solution, 0.344M Sulfuric Acid MSV System,Test,Antibodies,B2 - Glycoprotein I (B2 - Gpi) 2 QUANTA Lite® β2GPI IgG ELISA Bulk Pack
34 08426950595038 701252 1. QUANTA Flash ß2GP1 IgM Low Control 3 x 1 mL barcoded tubes of a solution with 1. QUANTA Flash ß2GP1 IgM Low Control 3 x 1 mL barcoded tubes of a solution with anti-ß2GP1 IgM in phosphate buffer containing bovine serum albimun, stabilizers and preservative.2. QUANTA Flash ß2GP1 IgM High Control 3 x 1 mL barcoded tubes of a solution with anti-ß2GP1 IgM in phosphate buffer containing bovine serum albumin, stabilizers and preservative. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® β2GPI IgM Controls
35 08426950595632 701198 1. 1 QUANTA Flash Centromere Reagent Cartridge2. 1 Resuspension buffer 3. 1 Transfer pipet LJM Antinuclear Antibody (Enzyme-Labeled), Antigen, Controls 2 QUANTA Flash® Centromere Reagents
36 08426950594635 708625.10 1. 10x ACA IgG III ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2 1. 10x ACA IgG III ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL prediluted ACA Negative Control 3. 5x 1.2mL prediluted ACA IgG III Control4. 5x 1.2mL prediluted ACA IgG III Calibrator A5. 5x 1.2mL prediluted ACA IgG III Calibrator B6. 5x 1.2mL prediluted ACA IgG III Calibrator C7. 5x 1.2mL prediluted ACA IgG III Calibrator D8. 5x 1.2mL prediluted ACA IgG III Calibrator E9. 9x 50mL ACA III Sample Diluent10. 10x 50mL ACA III PBS Concentrate, 20x concentrate11. 10x 10mL ACA IgG III Conjugate, (goat), anti-human IgG12. 10x 10mL TMB Chromogen13. 10x 10mL HRP Stop Solution, 0.344M Sulfuric Acid MID System, Test, Anticardiolipin Immunological 2 QUANTA Lite® ACA IgG III ELISA Bulk Pack
37 08426950594628 708990 1. 1x sp100 ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL predi 1. 1x sp100 ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL prediluted ELISA Negative Control 3. 1x 1.2mL prediluted sp100 ELISA Low Positive4. 1x 1.2mL prediluted sp100 ELISA High Positive5. 1x 50mL HRP Sample Diluent6. 1x 25mL HRP Wash Concentrate, 40x concentrate7. 1x 10mL HRP IgG Conjugate, (goat), anti-human IgG8. 1x 10mL TMB Chromogen9. 1x 10mL HRP Stop Solution, 0.344M Sulfuric Acid NUM Autoantibodies, Nuclear Body Protein, Sp100 2 QUANTA Lite® sp100 ELISA
38 08426950544258 701138 1. 1 QUANTA Flash PR3 Reagent Cartridge MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 QUANTA Flash® PR3 Reagents
39 08426950594543 708665.10L 1. 10 B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL pre 1. 10 B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL prediluted ELISA Negative Control 3. 5x 1.2mL prediluted 2 GPI IgG ELISA Control4. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator A5. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator B6. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator C7. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator D8. 1x 1.2mL prediluted 2 GPI IgG ELISA Calibrator E9. 9x 50mL HRP Sample Diluent10. 10x 25mL HRP Wash Concentrate, 40x concentrate11. 10x 10mL 2 HRP IgG Conjugate, (goat), anti-human IgG12. 10x 10mL TMB Chromogen13. 10x 10mL HRP Stop Solution, 0.344M Sulfuric Acid MSV System,Test,Antibodies,B2 - Glycoprotein I (B2 - Gpi) 2 QUANTA LITE® B2 GPI IgG ELISA Bulk Pack Kit (Lab Corp)
40 08426950594512 704655.10 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. MPO SC Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with MPO antigen, colour coded green. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. Type III Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured yellow, ready to use.5. HRP Wash Concentrate: 10 bottles containing 25mL of a 40-fold concentrated buffer for washing the wells. 6. MPO SC ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-MPO autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7.MPO SC Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP MPO SC IgG Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgG. Coloured blue, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11.HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use. MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 QUANTA Lite® MPO SC ELISA Bulk Pack
41 08426950593256 708715 1. 1x H. pylori IgG ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2 1. 1x H. pylori IgG ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL prediluted ELISA Negative Control 3. 1x 1.2mL prediluted H. pylori IgG ELISA Low Positive4. 1x 1.2mL prediluted H. pylori IgG ELISA High Positive5. 1x 50mL HRP Sample Diluent6. 1x 25mL HRP Wash Concentrate, 40x concentrate7. 1x 10mL HRP IgG Conjugate, (goat), anti-human IgG8. 1x 10mL TMB Chromogen9. 1x 10mL HRP Stop Solution, 0.344M Sulfuric Acid LYR Helicobacter Pylori 1 QUANTA Lite® H.pylori IgG ELISA
42 08426950594079 704520.10 1. 10x Gliadin IgG II ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1. 10x Gliadin IgG II ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL prediluted ELISA Negative Control 3. 5x 1.2mL prediluted Gliadin IgG II ELISA Low Positive4. 5x 1.2mL prediluted Gliadin IgG II ELISA High Positive5. 9 x50mL HRP Sample Diluent6. 10x 25mL HRP Wash Concentrate, 40x concentrate7. 10x 10mL HRP IgG Conjugate, (goat), anti-human IgG8. 10x 10mL TMB Chromogen9. 10x 10mL HRP Stop Solution, 0.344M Sulfuric Acid MST Antibodies, Gliadin 2 QUANTA Lite® Gliadin IgG II ELISA Bulk Pack
43 08426950593706 708775 (Soluble Liver Antigen)1.1x SLA ELISA microwell plate (12-1 x 8 wells), with hol (Soluble Liver Antigen)1.1x SLA ELISA microwell plate (12-1 x 8 wells), with holder2.1x 1.2mL prediluted ELISA Negative Control 3.1x 1.2mL prediluted SLA ELISA Low Positive4.1x 1.2mL prediluted SLA ELISA High Positive5.1x 50mL HRP Sample Diluent 6.1x 25mL HRP Wash Concentrate, 40x concentrate7.1x 10mL HRP IgG Conjugate, (goat), anti-human IgG8.1x 10mL TMB Chromogen9.1x 10mL HRP Stop Solution, 0.344M Sulfuric Acid NIY Autoantibodies, Anti-Soluble Liver Antigen (Sla), Autoimmune Hepatitis 2 QUANTA Lite® SLA ELISA
44 08426950593461 708101 1. 5 x 12-well HEp-2 Substrate Slides2. 1 x 4mL FITC Anti-Human IgG Conjugate3. 1. 5 x 12-well HEp-2 Substrate Slides2. 1 x 4mL FITC Anti-Human IgG Conjugate3. 1 x 0.5 mL ANA Titratable Endpoint Pattern Control4. 1 x 0.5mL IFA System Negative Control5. 1 x 25mL PBS II Concentrate (40x)6. 1 x 7mL Mounting Medium7. 1 x 20 Coverslips LLL Extractable Antinuclear Antibody, Antigen And Control 2 NOVA Lite® HEp-2 ANA Kit
45 08426950593430 704630 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 1 bottle containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgM ELISA Calibrators: 5 bottles each containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 MPS U/mL. Ready to use.7. Phosphatidylserine IgM Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP Phosphatidylserine IgM Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgM. Coloured blue, ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric acid. Ready to use. MID System, Test, Anticardiolipin Immunological 2 QUANTA Lite® Phosphatidylserine IgM ELISA
46 08426950593324 704545 1. 1x Celiac DGP Screen ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1. 1x Celiac DGP Screen ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL prediluted ELISA Negative Control 3. 1x 1.2mL prediluted Celiac DGP Screen ELISA Low Positive4. 1x 1.2mL prediluted Celiac DGP Screen ELISA High Positive5. 1x 50mL HRP Sample Diluent6. 1x 25mL HRP Wash Concentrate, 40x concentrate7. 1x 10mL HRP Ig G/A Conjugate, (goat), anti-human IgG and IgA8. 1x 10mL TMB Chromogen9. 1x 10mL HRP Stop Solution, 0.344M Sulfuric Acid MST Antibodies, Gliadin 2 QUANTA Lite® Celiac DGP Screen ELISA
47 08426950566373 701258 1. 1 QUANTA Flash ENA7 Reagent Cartridge2. 1 Resuspension buffer3. 1 Transfer pipet" LLL Extractable Antinuclear Antibody, Antigen And Control 2 QUANTA Flash® ENA7 Reagents
48 08426950557579 701167 1. QUANTA Flash DGP IgA Calibrator 1: Two (2) barcode labeled tubes containing 0 1. QUANTA Flash DGP IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to DGP in buffer, protein stabilizers, and preservatives. 2. QUANTA Flash DGP IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to DGP in buffer, protein stabilizers, and preservatives. JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® DGP IgA Controls
49 08426950554554 701137 1. QUANTA Flash PR3 Negative Control: Two (2) barcode labeled tubes with buffer 1. QUANTA Flash PR3 Negative Control: Two (2) barcode labeled tubes with buffer containing human serum antibodies to PR3, prediluted, ready to use, 0.5mL (containing buffer, protein stabilizers, and preservatives).2. QUANTA Flash PR3 Positive Control: Two (2) barcode labeled tubes with buffer containing human serum antibodies to PR3, prediluted, ready to use, 0.5mL (containing buffer, protein stabilizers, and preservatives). JJX Single (Specified) Analyte Controls (Assayed And Unassayed) 1 QUANTA Flash® PR3 Controls
50 08426950506362 704555 1. 1x RNA Pol III ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL 1. 1x RNA Pol III ELISA microwell plate (12-1 x 8 wells), with holder2. 1x 1.2mL prediluted, ready to use, ELISA Negative Control 3. 1x 1.2mL prediluted, ready to use, RNA Pol III ELISA Low Positive4. 1x 1.2mL prediluted, ready to use, RNA Pol III ELISA High Positive5. 1x 50mL HRP Sample Diluent6. 1x 25mL HRP Wash Concentrate, 40x concentrate7. 1x 10mL HRP IgG Conjugate, (goat), anti-human IgG8. 1x 10mL TMB Chromogen9. 1x 10mL HRP Stop Solution, 0.344M Sulfuric Acid NYO Autoantibodies, Anti-Ribonucleic Acid Polymerase (Rnap) Iii Antibody 2 QUANTA Lite® RNA Pol III ELISA
Other products with the same Product Code "JJX"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 06438115000112 145217 145217 QuikRead go® CRP Control Set is intended for use as assayed quality-control mate QuikRead go® CRP Control Set is intended for use as assayed quality-control material for monitoring the performance of the quantitative QuikRead go CRP assay with the QuikRead go Instrument. QuikRead go® CRP Control set AIDIAN OY
2 06438115000105 145216 145216 QuikRead go® CRP Verification Set is designed to be used for calibration verific QuikRead go® CRP Verification Set is designed to be used for calibration verification and for method validation of the QuikRead go® CRP system. It is intended for use with the QuikRead go® CRP test and the QuikRead go® instrument. QuikRead go® CRP Verification set AIDIAN OY
3 05700572014294 X0974 Cystatin C Calibrator Dako AGILENT TECHNOLOGIES SINGAPORE PTE LTD
4 05700572014287 X0973 Cystatin C Control Set Cystatin C Control Set AGILENT TECHNOLOGIES SINGAPORE PTE LTD
5 05700572013853 LX002 Cystatin C Immunoparticles Dako AGILENT TECHNOLOGIES SINGAPORE PTE LTD
6 05415168004763 08240426190 08240426190 Assayed control for Alpha2-Macroglobulin assay on cobas c501/502 systems. Alpha2-Macroglobulin Serum CONT KIT DIAGAM
7 05391516748216 Tri-stat Liquid Controls Kit 03-06-0011 Hemoglobin A1c assay, Tri-stat Liquid Controls Kit Trinity Biotech PRIMUS CORPORATION
8 05391516747240 A7040 A7040 ACE CONTROL-E Trinity Biotech CLARK LABORATORIES, INC.
9 05391516747233 A6040 A6040 ACE CONTROL-N Trinity Biotech CLARK LABORATORIES, INC.
10 05391516741897 450-22 450-22 Bile Acids Controls Trinity Biotech TRINITY BIOTECH PUBLIC LIMITED COMPANY
11 05060169695979 IS-ID6530 IDS SARS-COV-2 IgG Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
12 05060169695825 IS-2835US IDS-iSYS Ostase® BAP Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
13 05060169695818 IS-2830US IDS-iSYS Ostase® BAP Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
14 05060169695504 IS-4620 IDS Cortisol Calibrator Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
15 05060169695306 IS-2530 IDS-iSYS 25 VitDS Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
16 05060169693708 IS-5635 IDS SHBG Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
17 05060169691339 IS-5630 IDS SHBG Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
18 05060169691070 IS-5135 IDS-iSYS 17-OH Progesterone Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
19 05060169691049 IS-4835 IDS-iSYS Direct Renin Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
20 05060169691001 IS-4435 IDS-iSYS Insulin like Growth Factor Binding Protein-3 (IGFBP-3) Cal Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
21 05060169690981 IS-3935 IDS-iSYS Insulin like Growth Factor-I (IGF-1) Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
22 05060169690974 IS-3735 IDS-iSYS Human Growth Hormone (hGH) Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
23 05060169690967 IS-3335 IDS-iSYS Aldosterone Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
24 05060169690950 IS-3235 IDS-iSYS Intact PTH Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
25 05060169690943 IS-3035 IDS-iSYS CTX-I (Crosslaps) Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
26 05060169690929 IS-2535 IDS-iSYS 25 VitDS Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
27 05060169690912 IS-2435 IDS-iSYS 1,25-Dihydroxy Vitamin D Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
28 05060169690882 IS-5130 IDS-iSYS 17-OH Progesterone Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
29 05060169690851 IS-4830 IDS-iSYS Direct Renin Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
30 05060169690820 IS-4630 IDS Cortisol Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
31 05060169690752 IS-2530 IDS-iSYS 25 VitDS Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
32 05060169690424 IS-2735S IDS-iSYS 25-Hydroxy Vitamin DS Calibration Verifiers IMMUNODIAGNOSTIC SYSTEMS LIMITED
33 05060169690417 IS-2730S IDS-iSYS 25-Hydroxy Vitamin DS Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
34 05060169690370 IS-3330 IDS-iSYS Aldosterone Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
35 05060169690356 IS-2430 IDS-iSYS 1,25-Dihydroxy Vitamin D Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
36 05060169690318 IS-4430 IDS-iSYS Insulin-like Growth Factor Binding Protein 3 (IGFBP-3) Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
37 05060169690295 IS-3930 IDS-iSYS Insulin like Growth Factor-1 (IGF-I) Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
38 05060169690271 IS-3230 IDS-iSYS Intact PTH Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
39 05060169690257 IS-3030 IDS-iSYS CTX-I (Crosslaps) Control Set IMMUNODIAGNOSTIC SYSTEMS LIMITED
40 05055845400022 FHCY200 FHCY200 The Axis-Shield Homocysteine Control Kit is intended to be used as an assayed qu The Axis-Shield Homocysteine Control Kit is intended to be used as an assayed quality control serum when used for the quantitative measurement of total L-homocysteine in human serum or plasma. Axis-Shield Homocysteine Controls AXIS-SHIELD DIAGNOSTICS LIMITED
41 05055845400015 FHCY100 FHCY100 The Axis® Homocysteine Enzyme Immunoassay (EIA) is intended for the quantitative The Axis® Homocysteine Enzyme Immunoassay (EIA) is intended for the quantitative determination of total L-homocysteine in human serum or plasma. The device can assist in the diagnosis and treatment of patients suspected of having hyperhomocysteinemia and homocystinuria. Axis® Homocysteine EIA AXIS-SHIELD DIAGNOSTICS LIMITED
42 05055273217797 AMH10515 AMH10515 The AMH Control Level 3 (AMH10515) is intended for use with in vitro diagnostic The AMH Control Level 3 (AMH10515) is intended for use with in vitro diagnostic assays for the quantitative determination of Anti-Müllerian Hormone in human serum and plasma. The AMH Control Level 3 (AMH10515) is assayed with target values and is suitable for use on automated analysers.The AMH Control Level 3 (AMH10515) is for use by trained laboratory professionals and can be used in determining the precision of testing systems and in identifying sources of variation. AMH CONTROL LEVEL 3 (AMH CONTROL 3) RANDOX LABORATORIES LIMITED
43 05055273217780 AMH10514 AMH10514 The AMH Control Level 2 (AMH10514) is intended for use with in vitro diagnostic The AMH Control Level 2 (AMH10514) is intended for use with in vitro diagnostic assays for the quantitative determination of Anti-Müllerian Hormone in human serum and plasma. The AMH Control Level 2 (AMH10514) is assayed with target values and is suitable for use on automated analysers.The AMH Control Level 2 (AMH10514) is for use by trained laboratory professionals and can be used in determining the precision of testing systems and in identifying sources of variation. AMH CONTROL LEVEL 2 (AMH CONTROL 2) RANDOX LABORATORIES LIMITED
44 05055273217773 AMH10509 AMH10509 The AMH Control Level 1 (AMH10509) is intended for use with in vitro diagnostic The AMH Control Level 1 (AMH10509) is intended for use with in vitro diagnostic assays for the quantitative determination of Anti-Müllerian Hormone in human serum and plasma. The AMH Control Level 1 (AMH10509) is assayed with target values and is suitable for use on automated analysers.The AMH Control Level 1 (AMH10509) is for use by trained laboratory professionals and can be used in determining the precision of testing systems and in identifying sources of variation. AMH CONTROL LEVEL 1 (AMH CONTROL 1) RANDOX LABORATORIES LIMITED
45 05055273217766 AMH10516 AMH10516 The AMH Control Level 4 (AMH10516) is intended for use with in vitro diagnostic The AMH Control Level 4 (AMH10516) is intended for use with in vitro diagnostic assays for the quantitative determination of Anti-Müllerian Hormone in human serum and plasma. The AMH Control Level 4 (AMH10516) is assayed with target values and is suitable for use on automated analysers.The AMH Control Level 4 (AMH10516) is for use by trained laboratory professionals and can be used in determining the precision of testing systems and in identifying sources of variation. AMH CONTROL LEVEL 4 (AMH CONTROL 4) RANDOX LABORATORIES LIMITED
46 05055273217346 CQ10428 CQ10428 This product is intended for intended for use with in vitro diagnostic assays, f This product is intended for intended for use with in vitro diagnostic assays, for the quantitative determination of Troponin I. Cardiac Controls are unassayed without target values and are suitable for use on automated analysers. Cardiac Controls are for use by trained laboratory professionals and can be used in determining the precision of testing systems and in identifying sources of variation. CARDIAC ULTRA LOW CONTROL (CRD CONTROL Ultra Low) RANDOX LABORATORIES LIMITED
47 05055273216936 COV10460 COV10460 "SARS-CoV-2 (Severe acute respiratory syndrome coronavirus) Negative/Non-Reactiv "SARS-CoV-2 (Severe acute respiratory syndrome coronavirus) Negative/Non-Reactive ControlSARS-CoV-2 Negative/Non-Reactive Control is intended for use with in vitro assays for determination of Total antibodies to SARS-CoV-2 (Severe acute respiratory syndrome coronavirus).SARS-CoV-2 Negative/Non-Reactive Control is unassayed without target values and is suitable for use on various analysers. SARS-CoV-2 Negative/Non-Reactive Control is useful in determining the precision of testing systems and allows performance monitoring of multiple test systems.SARS-CoV-2 (Severe acute respiratory syndrome coronavirus) Positive/Reactive ControlSARS-CoV-2 Positive/Reactive Control is intended for use with in vitro assays for determination of Total antibodies to SARS-CoV-2 (Severe acute respiratory syndrome coronavirus).SARS-CoV-2 Positive/Reactive Control is unassayed without target values and is suitable for use on various analysers. SARS-CoV-2 Negative/Non-Reactive Control is useful in determining the precision of testing systems and allows performance monitoring of multiple test systems." SARS CoV-2 Controls (SARS-CoV-2) RANDOX LABORATORIES LIMITED
48 05055273216905 CYS10447 CYS10447 Intended for in vitro diagnostic (IVD) use in quality control of Randox Cystatin Intended for in vitro diagnostic (IVD) use in quality control of Randox Cystatin C assay. For use in a clinical laboratory setting by trained personnel. CYSTATIN C CONTROL - LEVEL 3 (CYSC CONTROL 3) RANDOX LABORATORIES LIMITED
49 05055273216899 CYS10446 CYS10446 Intended for in vitro diagnostic (IVD) use in quality control of Randox Cystatin Intended for in vitro diagnostic (IVD) use in quality control of Randox Cystatin C assay. For use in a clinical laboratory setting by trained personnel. CYSTATIN C CONTROL - LEVEL 2 (CYSC CONTROL 2) RANDOX LABORATORIES LIMITED
50 05055273216240 LV10343 LV10343 Rheumatoid Factor Linearity Verifiers are an in vitro diagnostic product used to Rheumatoid Factor Linearity Verifiers are an in vitro diagnostic product used to assess the linearity of Roche Systems for Rheumatoid Factor (RF). RHEUMATOID FACTOR LINEARITY VERIFIERS (For Roche Systems) (RFLV) RANDOX LABORATORIES LIMITED