The Celiac Disease IgA Calibrators include antibodies to tTG and DGP.1. Aptiva C
The Celiac Disease IgA Calibrators include antibodies to tTG and DGP.1. Aptiva Celiac IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives. 2. Aptiva Celiac IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives.3. Aptiva Celiac IgA Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies in stabilizers and preservatives.
1. QUANTA Flash RF IgM Negative Control: Two (2) barcode labeled tubes containin
1. QUANTA Flash RF IgM Negative Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to RF IgM in stabilizers and preservatives.2. QUANTA Flash RF IgM Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to RF IgM in stabilizers and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash aCL IgM Low Control 3 x 1 mL barcoded tubes of a solution with a
1. QUANTA Flash aCL IgM Low Control 3 x 1 mL barcoded tubes of a solution with aCL IgM in saline solution containing fetal bovine serum stabilizers and preservative.2. QUANTA Flash aCL IgM High Control 3 x 1 mL barcoded tubes of a solution with aCL IgM in saline solution containing fetal bovine serum, stabilizers and preservative.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash HMGCR Negative Control: Two (2) barcode labeled tubes containing
1. QUANTA Flash HMGCR Negative Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to HMGCR in stabilizers and preservatives.2. QUANTA Flash HMGCR Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to HMGCR in stabilizers and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.2. QUANTA Flash LKM-1 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.3. QUANTA Flash LKM-1 Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.
1. QUANTA Flash M2 (MIT3) Negative Control: Two (2) barcode labeled tubes contai
1. QUANTA Flash M2 (MIT3) Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to M2 (MIT3) in stabilizers and preservatives.2. QUANTA Flash M2 (MIT3) Positive Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to M2 (MIT3) in stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing
1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.2. QUANTA Flash M2 (MIT3) Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.3. QUANTA Flash M2 (MIT3) Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 10 bottles containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgG ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 GPS U/mL. Ready to use.7. Phosphatidylserine IgG Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9.HRP Phosphatidylserine IgG Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgG. Coloured red, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use.
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 10 bottles containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgM ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 GPS U/mL. Ready to use.7. Phosphatidylserine IgM Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP Phosphatidylserine IgM Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgM. Coloured blue, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use.
1. QUANTA Flash h-tTG IgG Negative Control: Two (2) barcode labeled tubes contai
1. QUANTA Flash h-tTG IgG Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to h-tTG in stabilizers and preservatives.2. QUANTA Flash h-tTG IgG Positive Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to h-tTG in stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, 5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgG Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgG autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. 7. R h-tTG IgG Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 9. HRP R h-tTG IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. 10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. 11. Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid.
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating t
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgA Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgA autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. 7.R h-tTG IgA Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. 8.ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate..9. HRP R h-tTG IgA Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgA. Colored yellow. 10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen.11.Stop Solution HRP: 1 bottle containing 10mL of 0.344M Sulfuric Acid.
1. QUANTA Flash h-tTG IgA Calibrator 1: Two (2) barcode labeled tubes containing
1. QUANTA Flash h-tTG IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to h-tTG in stabilizers and preservatives. 2. QUANTA Flash h-tTG IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to h-tTG in stabilizers and preservatives.
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating t
1. Instruction leaflet: Giving full assay details.2.QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgA Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgA autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7.R h-tTG IgA Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.8.ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP R h-tTG IgA Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgA. Colored yellow. Ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.11.Stop Solution HRP: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use.
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgG Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgG autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7. R h-tTG IgG Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP R h-tTG IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.11. Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use.
1.Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating t
1.Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. dsDNA SC Coated Wells: 12 breakapart 8 well strips coated with calf thymus dsDNA antigen. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.5. dsDNA SC Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-dsDNA autoantibody: 1000, 333, 111, 37, 12.3 IU/mL. Ready to use.6. dsDNA SC Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.7. Type III Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored yellow, ready to use.8. HRP Wash Concentrate (40X): 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.9.dsDNA SC Single Stranded Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.10. HRP dsDNA SC IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use.11. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.12. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use.
LRM
Anti-Dna Antibody (Enzyme-Labeled), Antigen, Control
1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.
1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives.2. QUANTA Flash RF IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives.
1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives. 2. QUANTA Flash Ro52 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives.
1. QUANTA Flash Centromere Negative Control: Two (2) barcode labeled tubes conta
1. QUANTA Flash Centromere Negative Control: Two (2) barcode labeled tubes containing 0.5 mL, ready to use reagent. Controls contain human antibodies to centromere in buffer, stabilizers, and preservatives.2. QUANTA Flash Centromere Positive Control: Two (2) barcode labeled tubes containing 0.5mL, ready to use reagent. Controls contain human antibodies to centromere in buffer, stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash ß2GP1 IgM Low Control 3 x 1 mL barcoded tubes of a solution with
1. QUANTA Flash ß2GP1 IgM Low Control 3 x 1 mL barcoded tubes of a solution with anti-ß2GP1 IgM in phosphate buffer containing bovine serum albimun, stabilizers and preservative.2. QUANTA Flash ß2GP1 IgM High Control 3 x 1 mL barcoded tubes of a solution with anti-ß2GP1 IgM in phosphate buffer containing bovine serum albumin, stabilizers and preservative.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. MPO SC Coated Wells: 10 plates containing 12 breakapart 8 well strips coated with MPO antigen, colour coded green. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. Type III Sample Diluent: 19 bottles containing 50mL of buffer for sample dilution. Coloured yellow, ready to use.5. HRP Wash Concentrate: 10 bottles containing 25mL of a 40-fold concentrated buffer for washing the wells. 6. MPO SC ELISA Calibrators: 25 bottles (5 bottles each) containing 1.2mL of diluted human serum, with the following concentrations of anti-MPO autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7.MPO SC Positive Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 5 bottles containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP MPO SC IgG Conjugate: 10 bottles containing 10mL of purified peroxidase labelled antibody to human IgG. Coloured blue, ready to use.10. TMB Chromogen: 10 bottles containing 10mL TMB substrate. Ready to use.11.HRP Stop Solution: 10 bottles containing 10mL of 0.344M Sulfuric acid. Ready to use.
MOB
Test System, Antineutrophil Cytoplasmic Antibodies (Anca)
1. 5 x 12-well HEp-2 Substrate Slides2. 1 x 4mL FITC Anti-Human IgG Conjugate3.
1. 5 x 12-well HEp-2 Substrate Slides2. 1 x 4mL FITC Anti-Human IgG Conjugate3. 1 x 0.5 mL ANA Titratable Endpoint Pattern Control4. 1 x 0.5mL IFA System Negative Control5. 1 x 25mL PBS II Concentrate (40x)6. 1 x 7mL Mounting Medium7. 1 x 20 Coverslips
LLL
Extractable Antinuclear Antibody, Antigen And Control
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating
1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Phosphatidylserine Coated Wells: 12 breakapart 8 well strips coated with Phosphatidylserine antigen. Each plate is packaged in a re-sealable foil bag containing 2 desiccant pouches.4. PS Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Coloured straw, ready to use.5. PBS Wash Concentrate (20x): 1 bottle containing 50mL of a 20-fold concentrated buffer for washing the wells. 6. Phosphatidylserine IgM ELISA Calibrators: 5 bottles each containing 1.2mL of diluted human serum, with the following concentrations of anti-Phosphatidylserine autoantibody: 100, 33.3, 11.1, 3.7, 1.23 MPS U/mL. Ready to use.7. Phosphatidylserine IgM Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate.Ready to use.8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP Phosphatidylserine IgM Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgM. Coloured blue, ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB substrate. Ready to use.11. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric acid. Ready to use.
1. QUANTA Flash DGP IgA Calibrator 1: Two (2) barcode labeled tubes containing 0
1. QUANTA Flash DGP IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to DGP in buffer, protein stabilizers, and preservatives. 2. QUANTA Flash DGP IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human IgA antibodies to DGP in buffer, protein stabilizers, and preservatives.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
1. QUANTA Flash PR3 Negative Control: Two (2) barcode labeled tubes with buffer
1. QUANTA Flash PR3 Negative Control: Two (2) barcode labeled tubes with buffer containing human serum antibodies to PR3, prediluted, ready to use, 0.5mL (containing buffer, protein stabilizers, and preservatives).2. QUANTA Flash PR3 Positive Control: Two (2) barcode labeled tubes with buffer containing human serum antibodies to PR3, prediluted, ready to use, 0.5mL (containing buffer, protein stabilizers, and preservatives).
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
ANA Detect is an ELISA test system for the qualitative measurement of IgG class
ANA Detect is an ELISA test system for the qualitative measurement of IgG class autoantibodies against SS-A-52 (Ro-52), SS-A-60 (Ro-60), SS-B (La), RNP/Sm, RNP-70, RNP-A, RNP-C, Sm-BB, Sm-D, Sm-E, Sm-F, Sm-G, Scl-70, Jo-1, dsDNA, ssDNA, ssDNA, polynucleosomes, mononucleosomes, histone complex, histone H1, histone H2A, histone H2B, histone 3, histone H4, Pm-Scl-100 and centromere B in human serum or plasma samples. This product is intended for professional in vitro diagnostic use only as an aid in the diagnosis of certain systematic rheumatic diseases.
ANTI-JO-1 IS AN EILSA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS
ANTI-JO-1 IS AN EILSA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS AUTOANTIBODIES AGAINST JO-1 IN HUMAN SERUM OR PLASMA. THIS PRODUCT IS INTENDED FOR PROFESSIONAL IN VITRO DIAGNOSTIC USE ONLY.
ANTI-SCL-70 IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLAS
ANTI-SCL-70 IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS AUTOANTIBODIES AGAINST SCL-70 IN HUMAN SERUM OR PLASMA. THIS PRODUCT IS INTENDED FOR PRFESSIONAL IN VITRO DIAGNOSTIC USE ONLY.
ANTI-RPN/SM IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLAS
ANTI-RPN/SM IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS AUTOANTIBODIES AGAINST RNP/SM IN HUMAN SERUM OR PLASMA. THIS PRODUCT IS INTENDED FOR PROFESSIONAL IN VITRO DIAGNOSTIC USE ONLY.
ANTI-SM IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS AU
ANTI-SM IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS AUTOANTIBODIES AGAINST SM IN HUMAN SERUM OR PLASMA. THIS PRODUCT IS INTENDED FOR PROFESSIONAL IN VITRO DIAGNOSTIC USE ONLY.
ANTI-SS-B IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS
ANTI-SS-B IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS AUTOANTIBODIES AGAINST SS-B (La) IN HUMAN SERUM OR PLASMA. THIS PRODUCT IS INTENDED FOR PROFESSIONAL IN VITRO DIAGNOSTIC USE ONLY.
ANTI-SS-A IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS
ANTI-SS-A IS AN ELISA TEST SYSTEM FOR THE QUANTITATIVE MEASUREMENT OF IgG CLASS AUTOANTIBODIES AGAINST SS-A (52 AND 60kDa) IN HUMAN SERUM OR PLASMA. THIS PRODUCT IS INTENDED FOR PROFESSIONAL IN VITRO DIAGNOSTIC USE ONLY.
AESKULISA Jo-1 is a solid phase enzyme immunoassay with recombinant human histid
AESKULISA Jo-1 is a solid phase enzyme immunoassay with recombinant human histidyltRNA-synthetase (HRS) for the quantitative and qualitative detection of antibodies against Jo-1 (named after the prototype patient) in human serum. Human sera with anti-Jo-1 antibodies solely recognize HRS of higher eukaryotes and react with highest affinity with the human enzyme. The assay is a tool in the diagnosis of polymyositis and dermatomyositis.
AESKULISA Cenp-B is a solid phase enzyme immunoassay employing purified recombin
AESKULISA Cenp-B is a solid phase enzyme immunoassay employing purified recombinant human 80 kDa centromere protein B (Cenp-B) for the quantitative and qualitative detection of IgG antibodies against Cenp-B in human serum. The assay ensures the highest specificity and sensitivity for the detection of antibodies against centromere protein B, which serves as an aid in the diagnosis of systemic sclerosis and CREST syndrome.
AESKULISA Scl-70 is a solid phase enzyme immunoassay with human recombinant 70 k
AESKULISA Scl-70 is a solid phase enzyme immunoassay with human recombinant 70 kDa fragment of DNA topoisomerase I for the quantitative and qualitative detection of antibodies against Scl-70 (70 kDa scleroderma antigen) in human serum. The assay is a tool in the differential diagnosis of systemic sclerosis.
AESKULISA SS-B is a solid phase enzyme immunoassay employing human recombinant L
AESKULISA SS-B is a solid phase enzyme immunoassay employing human recombinant La-antigen/ SS-B for the quantitative and qualitative detection of antibodies against Laantigen / SS-B in human serum. The assay is a tool in the diagnosis of Sjögren`s syndrome (SS) and systemic lupus erythematosus (SLE).
AESKULISA SS-A is a solid phase enzyme immunoassay for the quantitative and qual
AESKULISA SS-A is a solid phase enzyme immunoassay for the quantitative and qualitative detection of antibodies against Ro/ SS-A in human serum. The assay employs human Ro/SS-A antigen composed of highly purified native 60kDa and recombinant human 52 kDa Ro/SS-A protein. Anti-SS-A antibodies are species-specific (directed against human protein only) and preferentially react with the native 60kDa molecule where as most antibodies to the 52 kDa protein prefer the denatured molecule. The assay is a tool in the diagnosis of Sjögren`s syndrome (SS) and systemic lupus erythematosus (SLE).
AESKULISA Sm is a solid phase enzyme immunoassay with highly purified native Smi
AESKULISA Sm is a solid phase enzyme immunoassay with highly purified native Smith antigen (Sm) from human eukaryotic cells (HeLa) for the quantitative and qualitative detection of antibodies against Sm in human serum. Anti-Sm antibodies recognize specific conformational epitopes only accessible on native human Sm. The assay is a tool in the differential diagnosis of systemic lupus erythematosus (SLE).
AESKULISA snRNP-C is a solid phase enzyme immunoassay for the quantitative and q
AESKULISA snRNP-C is a solid phase enzyme immunoassay for the quantitative and qualitative detection of antibodies against the snRNP complex in human serum. The assay employs native human U1-snRNP complex highly purified from the cell-line HeLa. The U1-snRNP complex comprises the Smith antigen (Sm) and RNPs, the 70kDa U1specific protein plus protein A and C. The assay is a tool for the diagnosis of mixed connective tissue diseases (MCTD) and systemic lupus erythematosus (SLE)
AESKULISA U1-70 is a solid phase enzyme immunoassay employing recombinant human
AESKULISA U1-70 is a solid phase enzyme immunoassay employing recombinant human 70 kDa protein of the U1-snRNP complex for the quantitative and qualitative detection of antibodies against the 70 kDa U1-RNP in human serum. The assay is a tool in the diagnosis of mixed connective tissue diseases (MCTD) and systemic lupus erythematosus (SLE).
AESKULISA ENA-6Pro is a solid phase enzyme immunoassay for the separate semiquan
AESKULISA ENA-6Pro is a solid phase enzyme immunoassay for the separate semiquantitative detection of IgG antibodies against six cellular and nuclear antigens in human serum. The wells are coated with recombinant SS-B, SS-A 52 kDa, Scl 70, Jo-1 and highly purified native human snRNP/Sm, Sm and SS-A 60 kDa. The assay is a tool in the differential diagnosis of systemic rheumatic diseases.
AESKULISA ANA-8Pro is a solid phase enzyme immunoassay for the separate qualitat
AESKULISA ANA-8Pro is a solid phase enzyme immunoassay for the separate qualitative detection of IgG antibodies against eight cellular and nuclear antigens in human serum. The wells are separately coated with recombinant 70 kDa U1 snRNP, SS-B, SS-A 52 kDa, Scl 70, centromere protein B (CenpB), Jo-1 and highly purified native human snRNP/Sm, Sm and SS-A 60 kDa. The assay is a tool in the differential diagnosis of systemic rheumatic diseases.
AESKULISA Jo-1 is a solid phase enzyme immunoassay with recombinant human histid
AESKULISA Jo-1 is a solid phase enzyme immunoassay with recombinant human histidyltRNA-synthetase (HRS) for the quantitative and qualitative detection of antibodies against Jo-1 (named after the prototype patient) in human serum. Human sera with anti-Jo-1 antibodies solely recognize HRS of higher eukaryotes and react with highest affinity with the human enzyme. The assay is a tool in the diagnosis of polymyositis and dermatomyositis.
AESKULISA Cenp-B is a solid phase enzyme immunoassay employing purified recombin
AESKULISA Cenp-B is a solid phase enzyme immunoassay employing purified recombinant human 80 kDa centromere protein B (Cenp-B) for the quantitative and qualitative detection of IgG antibodies against Cenp-B in human serum. The assay ensures the highest specificity and sensitivity for the detection of antibodies against centromere protein B, which serves as an aid in the diagnosis of systemic sclerosis and CREST syndrome.
AESKULISA Scl-70 is a solid phase enzyme immunoassay with human recombinant 70 k
AESKULISA Scl-70 is a solid phase enzyme immunoassay with human recombinant 70 kDa fragment of DNA topoisomerase I for the quantitative and qualitative detection of antibodies against Scl-70 (70 kDa scleroderma antigen) in human serum. The assay is a tool in the differential diagnosis of systemic sclerosis.
AESKULISA SS-B is a solid phase enzyme immunoassay employing human recombinant L
AESKULISA SS-B is a solid phase enzyme immunoassay employing human recombinant La-antigen/ SS-B for the quantitative and qualitative detection of antibodies against Laantigen / SS-B in human serum. The assay is a tool in the diagnosis of Sjögren`s syndrome (SS) and systemic lupus erythematosus (SLE).
AESKULISA SS-A is a solid phase enzyme immunoassay for the quantitative and qual
AESKULISA SS-A is a solid phase enzyme immunoassay for the quantitative and qualitative detection of antibodies against Ro/ SS-A in human serum. The assay employs human Ro/SS-A antigen composed of highly purified native 60kDa and recombinant human 52 kDa Ro/SS-A protein. Anti-SS-A antibodies are species-specific (directed against human protein only) and preferentially react with the native 60kDa molecule where as most antibodies to the 52 kDa protein prefer the denatured molecule. The assay is a tool in the diagnosis of Sjögren`s syndrome (SS) and systemic lupus erythematosus (SLE).
AESKULISA Sm is a solid phase enzyme immunoassay with highly purified native Smi
AESKULISA Sm is a solid phase enzyme immunoassay with highly purified native Smith antigen (Sm) from human eukaryotic cells (HeLa) for the quantitative and qualitative detection of antibodies against Sm in human serum. Anti-Sm antibodies recognize specific conformational epitopes only accessible on native human Sm. The assay is a tool in the differential diagnosis of systemic lupus erythematosus (SLE).
AESKULISA snRNP-C is a solid phase enzyme immunoassay for the quantitative and q
AESKULISA snRNP-C is a solid phase enzyme immunoassay for the quantitative and qualitative detection of antibodies against the snRNP complex in human serum. The assay employs native human U1-snRNP complex highly purified from the cell-line HeLa. The U1-snRNP complex comprises the Smith antigen (Sm) and RNPs, the 70kDa U1specific protein plus protein A and C. The assay is a tool for the diagnosis of mixed connective tissue diseases (MCTD) and systemic lupus erythematosus (SLE)
AESKULISA U1-70 is a solid phase enzyme immunoassay employing recombinant human
AESKULISA U1-70 is a solid phase enzyme immunoassay employing recombinant human 70 kDa protein of the U1-snRNP complex for the quantitative and qualitative detection of antibodies against the 70 kDa U1-RNP in human serum. The assay is a tool in the diagnosis of mixed connective tissue diseases (MCTD) and systemic lupus erythematosus (SLE).
AESKULISA ENA-6Pro is a solid phase enzyme immunoassay for the separate semiquan
AESKULISA ENA-6Pro is a solid phase enzyme immunoassay for the separate semiquantitative detection of IgG antibodies against six cellular and nuclear antigens in human serum. The wells are coated with recombinant SS-B, SS-A 52 kDa, Scl 70, Jo-1 and highly purified native human snRNP/Sm, Sm and SS-A 60 kDa. The assay is a tool in the differential diagnosis of systemic rheumatic diseases.
AESKULISA ANA-8Pro is a solid phase enzyme immunoassay for the separate qualitat
AESKULISA ANA-8Pro is a solid phase enzyme immunoassay for the separate qualitative detection of IgG antibodies against eight cellular and nuclear antigens in human serum. The wells are separately coated with recombinant 70 kDa U1 snRNP, SS-B, SS-A 52 kDa, Scl 70, centromere protein B (CenpB), Jo-1 and highly purified native human snRNP/Sm, Sm and SS-A 60 kDa. The assay is a tool in the differential diagnosis of systemic rheumatic diseases.
Anti-Jo-1 ELISA is a test system for the quantitative measurement of class autoa
Anti-Jo-1 ELISA is a test system for the quantitative measurement of class autoantibodies against Jo-1 in human serum or plasma.
Anti-RNP/Sm ELISA is a test system for the quantitative measurement of IgG class
Anti-RNP/Sm ELISA is a test system for the quantitative measurement of IgG class autoantibodies against RNP/Sm in human serum or plasma.
Anti-Sm ELISA is a test system for the quantitative measurement of IgG class aut
Anti-Sm ELISA is a test system for the quantitative measurement of IgG class autoantibodies against Sm in human serum or plasma.
Anti-SS-B ELISA is a test system for the quantitative measurement of IgG class a
Anti-SS-B ELISA is a test system for the quantitative measurement of IgG class autoantibodies against SS-B (La) in human serum or plasma.
Anti-SS-A (Ro) ELISA is a test system for the quantitative measurement of IgG cl
Anti-SS-A (Ro) ELISA is a test system for the quantitative measurement of IgG class autoantibodies against SS-A (52 kDa and 60 kDa) in human serum or plasma.
ANA Combi ELISA is a test system for the qualitative measurement of ANA autoanti
ANA Combi ELISA is a test system for the qualitative measurement of ANA autoantibodies directed against RNP-70, RNP/Sm, Sm, SS-A (52 and 60 kDa), SS-B, Scl-70, Centromere B and Jo-1 in human serum or plasma.
ANA-8-Screen ELISA is a test system for the qualitative measurement of antinucle
ANA-8-Screen ELISA is a test system for the qualitative measurement of antinuclear antibodies (ANAs) SS-A (52 and 60 kDA), SS-B, RNP-70, Sm, RNP/Sm, Scl-70, Centromere B and Jo-1 in human serum or plasma.
AccuDiag ™ SSA/Ro antibody (Sjogren's antibody) IVD, kit, enzyme immunoassay (EI
AccuDiag ™ SSA/Ro antibody (Sjogren's antibody) IVD, kit, enzyme immunoassay (EIA)The SS-A Test System is a semi-quantitative immunoassay for the detection of IgG antibodies to SSA in human sera. When performed according to these instructions, the results of this assay may aid in the diagnosis and treatment of autoimmune connective tissue disorders. A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of anti-SSA or anti-Ro antibodies (Sjogren's antibodies) in a clinical specimen, using an enzyme immunoassay (EIA) method.