QUANTA Lite® R h-tTG IgG ELISA - 1. Instruction leaflet: Giving full assay - INOVA DIAGNOSTICS, INC.

Duns Number:188354831

Device Description: 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expect 1. Instruction leaflet: Giving full assay details.2. QC Certificate: Indicating the expected performance of the batch.3. Human Transglutaminase Coated Wells: 12 breakapart 8 well strips coated with recombinant tTG. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches.4. HRP Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored pink, ready to use.5. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells.6. R h-tTG IgG Calibrators: 5 bottles, each containing 1.2mL of diluted human serum, with the following concentrations of anti-tTG IgG autoantibody: 100, 33.3, 11.1, 3.7, 1.23 U/mL. Ready to use.7. R h-tTG IgG Positive Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.8. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use.9. HRP R h-tTG IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use.10. TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use.11. Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use.

Want to know more about this Product? Request more information now!


More Product Details

Catalog Number

-

Brand Name

QUANTA Lite® R h-tTG IgG ELISA

Version/Model Number

704610

Device Commercial Distribution Status

In Commercial Distribution

Commercial Distribution End Date

-

Issuing Agency

In GS1

Product Characteristics

MRI safety Status

Labeling does not contain MRI Safety Information

Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)

-

Device labeled as "Not made with natural rubber latex"

-

For Single-Use

Yes

Prescription Use (Rx)

Yes

Over the Counter (OTC)

-

Kit

-

Combination Product

-

Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)

-

FDA Premarket Submission

K040466

Product Code Details

Product Code

MVM

Product Code Name

Autoantibodies, Endomysial(Tissue Transglutaminase)

Device Record Status

Public Device Record Key

106e4c33-ecdd-403d-bb21-1d43cc7dcc04

Public Version Date

July 06, 2018

Public Version Number

3

DI Record Publish Date

August 31, 2016

Additional Identifiers

Package DI Number

None

Quantity per Package

-

Contains DI Package

-

Package Discontinue Date

-

Package Status

-

Package Type

-

"INOVA DIAGNOSTICS, INC." Characteristics
Device Class Device Class Description No of Devices
1 A medical device with low to moderate risk that requires general controls 36
2 A medical device with a moderate to high risk that requires special controls. 215