No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 08058964720122 800009 MBB,LOD Bone Cement, Antibiotic,Bone Cement 2 G3A 40 Bone Cement
2 08058964726087 900001 144818 "Disposable cement spacer molds with metal reinforcement stem are indicated for "Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge." MBB,KWS Bone Cement, Antibiotic,Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented 2 SpaceFlex Shoulder
3 08058964726070 900001 124818 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. MBB,KWS Bone Cement, Antibiotic,Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented 2 SpaceFlex Shoulder
4 08058964726063 900001 124215 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. MBB,KWS Bone Cement, Antibiotic,Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented 2 SpaceFlex Shoulder
5 08058964726056 900001 104818 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. MBB,KWS Bone Cement, Antibiotic,Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented 2 SpaceFlex Shoulder
6 08058964726049 900001 104215 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. MBB,KWS Bone Cement, Antibiotic,Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented 2 SpaceFlex Shoulder
7 08058964724977 900001 084215 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. MBB,KWS Bone Cement, Antibiotic,Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented 2 SpaceFlex Shoulder
8 08058964726766 900027 900027 Kyphoplasty Balloon Catheter NDN,HRX Cement, Bone, Vertebroplasty,Arthroscope 2 Winch Kyphoplasty ( 15 mm) 11 Gauge Balloon Catheter
9 08058964726759 800019 800019 Bone Cement MBB,LOD Bone Cement, Antibiotic,Bone Cement 2 OrthoSteady G
10 08058964726339 900027 900027 Kyphoplasty Balloon Catheter HRX,NDN Arthroscope,Cement, Bone, Vertebroplasty 2 Winch Kyphoplasty ( 15 mm) 11 Gauge Balloon Catheter
11 08058964726773 900028 900028 Kyphoplasty Balloon Catheter HRX,NDN Arthroscope,Cement, Bone, Vertebroplasty 2 Winch Kyphoplasty ( 20 mm) 11 Gauge Balloon Catheter
12 08058964726407 900028 900028 Kyphoplasty Balloon Catheter NDN,HRX Cement, Bone, Vertebroplasty,Arthroscope 2 Winch Kyphoplasty ( 20 mm) 11 Gauge Balloon Catheter
13 08058964726186 900008 SpaceFlex Hip Instrument Kit is intended to be used in combination with SpaceFle SpaceFlex Hip Instrument Kit is intended to be used in combination with SpaceFlex Hip to mold temporary prosthesis. MBB,KWY,KWL Bone Cement, Antibiotic,Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Bone Cement, Antibiotic,Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented,Prosthesis, Hip, Hemi-, Femoral, Metal 2 SpaceFlex Hip Instrument Kit
14 08058964726902 900005 15 Disposable custom modular spacer mold KWL,KWY,MBB Prosthesis, Hip, Hemi-, Femoral, Metal,Prosthesis, Hip, Hemi-, Femoral, Metal/Po Prosthesis, Hip, Hemi-, Femoral, Metal,Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented,Bone Cement, Antibiotic 2 SpaceFlex Hip
15 08058964726896 900005 13 Disposable custom modular spacer mold MBB,KWY,KWL Bone Cement, Antibiotic,Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Bone Cement, Antibiotic,Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented,Prosthesis, Hip, Hemi-, Femoral, Metal 2 SpaceFlex Hip
16 08058964726889 900005 10 Disposable custom modular spacer mold KWL,KWY,MBB Prosthesis, Hip, Hemi-, Femoral, Metal,Prosthesis, Hip, Hemi-, Femoral, Metal/Po Prosthesis, Hip, Hemi-, Femoral, Metal,Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented,Bone Cement, Antibiotic 2 SpaceFlex Hip
17 08058964727039 900189 80 Orthopedic bone cement modular spacer for temporary knee prosthesis MBB,JWH Bone Cement, Antibiotic,Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Bone Cement, Antibiotic,Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer 2 SpaceFlex Knee
18 08058964726940 900189 70 MBB,JWH Bone Cement, Antibiotic,Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Bone Cement, Antibiotic,Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer 2 SpaceFlex Knee
19 08058964726933 900189 60 MBB,JWH Bone Cement, Antibiotic,Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Bone Cement, Antibiotic,Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer 2 SpaceFlex Knee
20 08058964723970 800002 Radiopaque Bone Cement LOD Bone Cement 2 G1 40 Radiopaque Bone Cement
21 08058964726742 900187 900187 Curette with curved distal end used to create a cavity inside the vertebra. HTF Curette 1 FLEX DRILL 13G
22 08058964720245 800036 800036 Radiopaque Bone Cement for vertebral consolidation LOD,NDN Bone Cement,Cement, Bone, Vertebroplasty 2 V-FAST
23 08058964720047 800004 Radiopaque Bone Cement LOD Bone Cement 2 G3 40 Radiopaque Bone Cement
Other products with the same Product Codes "NDN, LOD"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 07613327554700 1033-120-000 1033-120-000 11G 20mm Extra Level Kit Omnicurve STRYKER CORPORATION
2 07613327554687 1033-115-000 1033-115-000 11G 15mm Extra Level Kit Omnicurve STRYKER CORPORATION
3 07613327554663 1032-120-000 1032-120-000 11G 20mm Fracture Kit Omnicurve STRYKER CORPORATION
4 07613327554496 1032-115-000 1032-115-000 11G 15mm Fracture Kit Omnicurve STRYKER CORPORATION
5 07613327374605 1031115000 1031115000 11 gauge 15mm AVAflex Vertebral Balloon System AVAflex STRYKER CORPORATION
6 07613327374599 1031030000 1031030000 10 gauge 30mm AVAflex Vertebral Balloon System AVAflex STRYKER CORPORATION
7 07613327374582 1031120000 1031120000 11 gauge 20mm AVAflex Vertebral Balloon System AVAflex STRYKER CORPORATION
8 07613327374575 1031020000 1031020000 10 gauge 20mm AVAflex Vertebral Balloon System AVAflex STRYKER CORPORATION
9 07613327374568 1031015000 1031015000 10 gauge 15mm AVAflex Vertebral Balloon System AVAflex STRYKER CORPORATION
10 07613327374551 1031130000 1031130000 11 gauge 30mm AVAflex Vertebral Balloon System AVAflex STRYKER CORPORATION
11 07613327374483 1021310000 1021310000 Inflatable Vertebral Augmentation System IVAS STRYKER CORPORATION
12 07613327374476 1021320000 1021320000 Inflatable Vertebral Augmentation System IVAS STRYKER CORPORATION
13 07613327374469 1021315000 1021315000 Inflatable Vertebral Augmentation System IVAS STRYKER CORPORATION
14 07613327358346 808815800 0808-815-800 8 gauge 15mm iVAS Elite Fracture Kit iVAS STRYKER CORPORATION
15 07613327358339 808115800 0808-115-800 11 gauge 15mm iVAS Elite Fracture Kit iVAS STRYKER CORPORATION
16 07613327358322 808820800 0808-820-800 8 gauge 20mm iVAS Elite Fracture Kit iVAS STRYKER CORPORATION
17 07613327358315 808110800 0808-110-800 11 gauge 10mm iVAS Elite Fracture Kit iVAS STRYKER CORPORATION
18 07613327358308 808010800 0808-010-800 10 gauge 10mm iVAS Elite Fracture Kit iVAS STRYKER CORPORATION
19 07613327358292 808020800 0808-020-800 10 gauge 10mm iVAS Elite Single Kit iVAS STRYKER CORPORATION
20 07613327358278 808015800 0808-015-800 10 gauge 15mm iVAS Elite Fracture Kit iVAS STRYKER CORPORATION
21 07613327357868 0507486000 0507-486-000 Precision System with Extension Tube and Bone Cement PCD, VertaPlex STRYKER CORPORATION
22 07613327357851 0507586000 0507-586-000 Precision System with Extension Tube and HV Bone Cement PCD, VertaPlex STRYKER CORPORATION
23 07613327357844 0507489000 0507-489-000 Precision System with Short Extension Tube and Bone Cement PCD, VertaPlex STRYKER CORPORATION
24 07613327170566 0406402015 0406-402-015 Radiopaque Bone Cement VertaPlex STRYKER CORPORATION
25 07613327170559 0406622015 0406-622-015 20 Gram Twin Pack (1/2 dose) VertaPlex HV STRYKER CORPORATION
26 07613327142792 808820000 0808-820-000 8 gauge 20mm iVAS Elite Single Kit iVAS STRYKER CORPORATION
27 07613327142785 808015000 0808-015-000 10 gauge 15mm iVAS Elite Single Balloon Kit iVAS STRYKER CORPORATION
28 07613327142778 808815000 0808-815-000 8 gauge 15mm iVAS Elite Single Balloon Kit iVAS STRYKER CORPORATION
29 07613327142761 808115500 0808-115-500 11 gauge 15mm iVAS Elite Balloon Catheter iVAS STRYKER CORPORATION
30 07613327142754 808020500 0808-020-500 10 gauge 20mm iVAS Elite Balloon Catheter iVAS STRYKER CORPORATION
31 07613327142747 808110500 0808-110-500 11 gauge 10mm iVAS Elite Balloon Catheter iVAS STRYKER CORPORATION
32 07613327142730 808015500 0808-015-500 10 gauge 15mm iVAS Elite Balloon Catheter iVAS STRYKER CORPORATION
33 07613327142723 808010500 0808-010-500 10 gauge 10mm iVAS Elite Balloon Catheter iVAS STRYKER CORPORATION
34 07613327142716 808115000 0808-115-000 11 gauge 15mm iVAS Elite Single Balloon Kit iVAS STRYKER CORPORATION
35 07613327142709 808110000 0808-110-000 11 gauge 10mm iVAS Elite Single Kit iVAS STRYKER CORPORATION
36 07613327142693 808020000 0808-020-000 10 gauge 20mm iVAS Elite Single Kit iVAS STRYKER CORPORATION
37 07613327142686 808010000 0808-010-000 10 gauge 10mm iVAS Elite Single Kit iVAS STRYKER CORPORATION
38 07613327141818 0406422000 0406422000 Half Dose Radiopaque Bone Cement VertaPlex STRYKER CORPORATION
39 07613327141788 0406202010 0406-202-010 Half Dose SpinePlex STRYKER CORPORATION
40 07613327141771 0406222000 0406222000 Half Dose SpinePlex STRYKER CORPORATION
41 07613327141764 0406402002 0406-402-002 Half Dose VertaPlex STRYKER CORPORATION
42 07613327128451 6192-1-001 6192-1-001 SpeedSet Full Dose Antibiotic Bone Cement, 10 pack catalog number is 6192-1-010 Simplex HOWMEDICA OSTEONICS CORP.
43 07613327128444 6191-1-001 6191-1-001 Full Dose Bone Cement, 10 pack catalog number is 6191-1-010 Simplex HOWMEDICA OSTEONICS CORP.
44 07613327128437 6188-1-001 6188-1-001 Half Dose Bone Cement, 10 pack catalog number is 6188-1-010 Simplex HOWMEDICA OSTEONICS CORP.
45 07613327128420 6197-9-001 6197-9-001 Tobra Full Dose Antibiotic Bone Cement, 10 pack catalog number is 6197-9-010 Simplex HOWMEDICA OSTEONICS CORP.
46 J014002112140011 R 00-1112-140-01 PALACOS® R is a fast-curing, radiopaque, poly(methyl methacrylate)-based bone ce PALACOS® R is a fast-curing, radiopaque, poly(methyl methacrylate)-based bone cement.PALACOS ® R contains the X-ray contrast medium zirconium dioxide. To improve visibility in the surgical field PALACOS ® R has been coloured with chlorophyll (E141). The bone cement is prepared directly before use by mixing a polymer powder component with a liquid monomer component. A ductile dough forms which cures within a few minutes. PALACOS HERAEUS MEDICAL GMBH
47 J014001119140011 LV+G 00-1119-140-01 PALACOS® LV+G is a slow-curing, radiopaque, poly(methyl methacrylate)-based bone PALACOS® LV+G is a slow-curing, radiopaque, poly(methyl methacrylate)-based bone cement. It contains the aminoglycoside antibiotic gentamicin.PALACOS® LV+G contains the X-ray contrast medium zirconium dioxide. To improve visibility in the surgical field PALACOS® LV+G has been coloured with chlorophyll (E141).The bone cement is prepared directly before use by mixing a polymer powder component with a liquid monomer component. A ductile dough forms which cures within a few minutes. PALACOS HERAEUS MEDICAL GMBH
48 J014001118140011 LV 00-1118-140-01 PALACOS® LV is a slow-curing, radiopaque, poly(methyl methacrylate)-based bone c PALACOS® LV is a slow-curing, radiopaque, poly(methyl methacrylate)-based bone cement.PALACOS® LV contains the X-ray contrast medium zirconium dioxide. To improve visibility in the surgical field it has been coloured with chlorophyll (E141).The bone cement is prepared directly before use by mixing a polymer powder component with a liquid monomer component. A ductile dough forms which cures within a few minutes. PALACOS HERAEUS MEDICAL GMBH
49 J014001113140011 R+G 00-1113-140-01 PALACOS® R+G is a fast setting polymer containing gentamicin, for use in bone su PALACOS® R+G is a fast setting polymer containing gentamicin, for use in bone surgery. Mixing of the two component system, consisting of a powder and a liquid, initially produces a liquid and then a paste, which is used to anchor the prosthesis to the bone. The hardened bone cement allows stable fixation of the prosthesis and Transfers all stresses produced in a movement to the bone via the large interface. Insoluble zirconium dioxide is included in the cement powder as an X ray contrast medium. The chlorophyll additive serves as optical marking of the bone cement at the site of the operation. PALACOS HERAEUS MEDICAL GMBH