S-MAIA is intended for measuring macular sensitivity, fixation stability and the
S-MAIA is intended for measuring macular sensitivity, fixation stability and the locus of fixation, as well as providing infrared retinal imaging. It contains a reference database that is a quantitative tool for the comparison of macular sensitivity to a database of known normal subjects. The S-MAIA allows also the measurement of macular sensitivity and fixation under scotopic (or low light) background conditions, in addition to the standard measurement performed in mesopic conditions. Both a scotopic red (stimulus central wavelength 627 nm) and scotopic blue (stimulus central wavelength 550 nm) test modalities are available with the Scotopic model. Both modalities employ specific luminance scales and do not allow comparison with reference normal values.
COMPASS is a scanning ophthalmoscope combined with an automatic perimeter that a
COMPASS is a scanning ophthalmoscope combined with an automatic perimeter that allows the acquisition of images of the retina, as well as the measurement of retinal threshold sensitivity and the analysis of fixation..
MAIA is intended for measuring macular sensitivity, fixation stability and the l
MAIA is intended for measuring macular sensitivity, fixation stability and the locus of fixation, as well as providing infrared retinal imaging. It contains a reference database that is a quantitative tool for the comparison of macular sensitivity to a database of known normal subjects.
The CenterVue EIDON FA is a confocal scanning ophthalmoscope indicated for color
The CenterVue EIDON FA is a confocal scanning ophthalmoscope indicated for color, infrared and auto-fluorescence imaging and fluorescein angiography of a human retina with or without the use of a mydriatic agent.
EIDON AF (Eidon from Greek eidou, “to see” and AF, AutoFluorescence) is a scanni
EIDON AF (Eidon from Greek eidou, “to see” and AF, AutoFluorescence) is a scanning ophthalmoscope which uses infrared and visible light to obtain confocal infrared reflectance images, confocal visible reflectance images of the retina and fluorescence images of the retina, without pharmacological dilation.EIDON is a standalone device.
RETIA is a scanning ophthalmoscope which uses infrared and blue light to obtain
RETIA is a scanning ophthalmoscope which uses infrared and blue light to obtain confocal infrared reflectance images and fluorescence images of the retina.
EIDON is a scanning ophthalmoscope which uses infrared and visible light to obta
EIDON is a scanning ophthalmoscope which uses infrared and visible light to obtain confocal images of the retina, without pharmacological dilation. EIDON is a standalone device.
The CenterVue DRSplus is a confocal scanning ophthalmoscope indicated for color
The CenterVue DRSplus is a confocal scanning ophthalmoscope indicated for color imaging of a human retina without the use of a mydriatic agent.
The CenterVue Retia 2 Camera is intended for taking digital autofluorescence ima
The CenterVue Retia 2 Camera is intended for taking digital autofluorescence images of the human retina with and without use of a mydriatic agent to aid in the diagnosis and monitoring of diseases and disorders that manifest in the retina.
This system adopts the most advanced Optical-electro-mechanical Integration tech
This system adopts the most advanced Optical-electro-mechanical Integration technology. It integrates digital Fundus-Fluorescein-Angiography camera and digital-fundus-images acquisition and processing system, which can continuously display real-time, high quality color fundus images as well as black-white Fundus-Fluorescein-Angiography video images. The fundus images acquisition and processing system can process (full digital), record (real-time and completely) and save the color fundus images as well as retinal-fluorescein-angiography dynamic & static images into the computer. You can modify pictures, check reports, edit Graph-texts and manage all the dates at any time you want; you can measure and calculate the size of the case focus; you can zoom, move, stick, and put together the pictures; you can adjust the color on the picture, you can also record all the data on the CD, which can assistant scientific research and teaching. This system has combine function of many fundus image acquisition instruments, which can support medical treatments.
This system adopts the most advanced Optical-electro-mechanical Integration tech
This system adopts the most advanced Optical-electro-mechanical Integration technology. It integrates digital Fundus-Fluorescein-Angiography camera and digital-fundus-images acquisition and processing system, which can continuously display real-time, high quality color fundus images as well as black-white Fundus-Fluorescein-Angiography video images. The fundus images acquisition and processing system can process (full digital), record (real-time and completely) and save the color fundus images as well as retinal-fluorescein-angiography dynamic & static images into the computer. You can modify pictures, check reports, edit Graph-texts and manage all the dates at any time you want; you can measure and calculate the size of the case focus; you can zoom, move, stick, and put together the pictures; you can adjust the color on the picture, you can also record all the data on the CD, which can assistant scientific research and teaching. This system has combine function of many fundus image acquisition instruments, which can support medical treatments.
This system adopts the most advanced Optical-electro-mechanical Integration tech
This system adopts the most advanced Optical-electro-mechanical Integration technology. It integrates digital Fundus-Fluorescein-Angiography camera and digital-fundus-images acquisition and processing system, which can continuously display real-time, high quality color fundus images as well as black-white Fundus-Fluorescein-Angiography video images. The fundus images acquisition and processing system can process (full digital), record (real-time and completely) and save the color fundus images as well as retinal-fluorescein-angiography dynamic & static images into the computer. You can modify pictures, check reports, edit Graph-texts and manage all the dates at any time you want; you can measure and calculate the size of the case focus; you can zoom, move, stick, and put together the pictures; you can adjust the color on the picture, you can also record all the data on the CD, which can assistant scientific research and teaching. This system has combine function of many fundus image acquisition instruments, which can support medical treatments.
This device is used to create digital colour photographic images of the ocular f
This device is used to create digital colour photographic images of the ocular fundus through the pupil, to aid in diagnosing and monitoring retinal pathology.
Volk Pictor Prestige retinal set including Pictor Prestige camera and Pictor Pre
Volk Pictor Prestige retinal set including Pictor Prestige camera and Pictor Prestige retina module.
Volk Pictor Prestige full set including Pictor Prestige camera, Pictor Prestige
Volk Pictor Prestige full set including Pictor Prestige camera, Pictor Prestige Retina module and Pictor Prestige Anterior module.
The NIDEK MICROPERIMETER, MP-3 measures the visual sensitivity of a specified ar
The NIDEK MICROPERIMETER, MP-3 measures the visual sensitivity of a specified area on the fundus according to the patient’s response, and captures color fundus images. The fundus image overlaid with the retinal sensitivity mapping is displayed on the screen for fundus-image-correlated evaluation.
The assembly system (control unit & DS-10EA Adapter & existing endoscope in the
The assembly system (control unit & DS-10EA Adapter & existing endoscope in the market) can be used to record digital photographs and video ofthe body.
NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital pho
NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area.
The NIDEK NON-MYDRIATIC AUTO FUNDUS CAMERA, AFC-330 captures fundus images using
The NIDEK NON-MYDRIATIC AUTO FUNDUS CAMERA, AFC-330 captures fundus images using a built-in color CCD camera without the use of mydriatic agents. The AFC-330 is useful not only for ophthalmology but also for fundus photography in medical examinations such as for diabetes. With this single device, registration of patient information, image capture, and viewing of captured images are possible. In addition, captured images can be output to a USB flash drive, and printed using a printer. By connecting a personal computer (PC) to the device via a LAN and installing the optional image filing system software, images captured by this device can be transferred to the PC at high speed, and viewed and managed on the PC.
The NAVIS-EX image filing software is software that acquires data from the follo
The NAVIS-EX image filing software is software that acquires data from the following NIDEK fundus photography devices and files it for easy transfer to external systems. NAVIS-EX is equipped with functions for image acquiring, image display, image drawing, image processing, image measurement, panorama image creation, stereo image observation, composite image creation, and Follow-Up. (According to the image, available functions are limited.) Image data can be transferred by network or e-mail. NAVIS-EX can construct a network among multiple terminals and refers to and edits data from the clientPC.
The KOWA DR-1α is an ocular surface interferometer, which is an ophthalmic imagi
The KOWA DR-1α is an ocular surface interferometer, which is an ophthalmic imaging device that is intended for use by physician in adult patients to observe and record a video image of specular (interferometric) observations of the tear film, which can be visually monitored and photographically documented.
KOWA nonmyd 7 is intended for use with retina image capturing without mydriatic.
KOWA nonmyd 7 is intended for use with retina image capturing without mydriatic. The retina image can be stored to an image filing equipment through serial interface.
The KOWA VX-20 is intended for taking pictures of retinal images with mydriatic
The KOWA VX-20 is intended for taking pictures of retinal images with mydriatic or without mydriatic.
KOWA nonmyd WX is intended for use with plane and stereo retinal image capturing
KOWA nonmyd WX is intended for use with plane and stereo retinal image capturing without mydriatic. The retina image can be stored to an image filing derive through serial interface.
KOWA VX-10a is intended for taking pictures of fundus images with mydriatic or w
KOWA VX-10a is intended for taking pictures of fundus images with mydriatic or without mydriatic.
The Kowa hand-held retinal camera, KOWA GENESIS-D is a device intended to captur
The Kowa hand-held retinal camera, KOWA GENESIS-D is a device intended to capture and save fundus images with mydriatic.
KOWA VX-10 is intended for taking pictures of fundus images with mydriatic or wi
KOWA VX-10 is intended for taking pictures of fundus images with mydriatic or without mydriatic.
KOWA nonmyd a-DIII, fundus camera, is intended for use with retinal image captur
KOWA nonmyd a-DIII, fundus camera, is intended for use with retinal image capturing without mydriatic. The retinal image can be stored to an image filing drive through serial interface.