The handle is proposed as accessory for the carbon offset reamer handles.This is
The handle is proposed as accessory for the carbon offset reamer handles.This is a reusable device.
Offset Reamer handles designed for required minimally invasive surgical approach
Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. Various connections with reamer cutting tool and couplings with power tool (Big AO, Stryker-Zimmer/Hall and Harris) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device.
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø10 x 348 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
A hand-held re-usable surgical device designed to tighten implantable screws int
A hand-held re-usable surgical device designed to tighten implantable screws into bones during orthopedic or traumatologic surgery. Many variable tips exist in several dimensions allowing to be used with a large range of screws. The handle is also available in different kind of shapes. The U-joint permits to screw in various axis orientations
HXX
Screwdriver
1
Hexagonal U-joint screwdriver 3.5mm, S / Z-H coupling
A hand-held re-usable surgical device designed to simultaneously direct the plac
A hand-held re-usable surgical device designed to simultaneously direct the placement and angle of the drill hole and protect the surrounding tissue. It is cannulated to accept a dedicated drill bit size and has a serrated distal end to allow firm placement on the bone. The variable angle is from 25° to 65°.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø16 x 483 mm, can. Ø3.1 mm Hudson coup.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø7.5 x 475 mm, can. Ø3.1 mm Hudson coup.
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø16 x 30 mm, can. Ø3.1 mm
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø13 x 27 mm, can. Ø3.1 mm
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Big AO coup.
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø6.5 x 341 mm, can. Ø2.3 mm, Big AO coup.
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø24 x 39 mm, can. Ø3.4 mm
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø19.5 x 34 mm, can. Ø3.4 mm
A hammer with a mobile mass can be attached to the extraction clamp, as well as
A hammer with a mobile mass can be attached to the extraction clamp, as well as on the hook. It permits to give the necessary impact to extract the knee implants. This is a reusable device.
Hook, in combination with the slap hammer, is intended to help the surgeon to pu
Hook, in combination with the slap hammer, is intended to help the surgeon to pull/liberate the components in area where the access, due to soft tissues, is limited. When the instrument is placed at the femoral distal trochlea groove, it is ideal for pulling off the femoral implant. This is a reusable device.
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
Offset Reamer handles designed for required minimally invasive surgical approach
Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. A non clipped and dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device.
Reamer handles designed for all required surgical approach of the hip joint. A d
Reamer handles designed for all required surgical approach of the hip joint. A dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available.The handle could be disassembled allowing the cleaning of the instrument. This is a reusable device.
The drills with a transversal pin, permitting the transmission of the torque, ar
The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool.