Other products from "MPS PRECIMED SA"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07640187916652 T10924 T10924 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø45
2 07640187913538 T18044 T18044 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø70 with round tooth
3 07640187913620 T18053 T18053 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø79 with round tooth
4 07640187916867 T18381 T18381 Offset Reamer handles designed for required minimally invasive surgical approach Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. Various connections with reamer cutting tool and couplings with power tool (Big AO, Stryker-Zimmer/Hall and Harris) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Carbon offset reamer handle Harris with parking
5 07640187916829 T10941 T10941 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø62
6 07640187916782 T10937 T10937 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø58
7 07640187916751 T10934 T10934 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø55
8 07640187916744 T10933 T10933 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø54
9 07640187916621 T10921 T10921 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø42
10 07640187915754 T7649 T7649 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø10 x 348 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
11 07640187913453 T18036 T18036 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø62 with round tooth
12 07640187914290 T12632 T12632 A hand-held re-usable surgical device designed to tighten implantable screws int A hand-held re-usable surgical device designed to tighten implantable screws into bones during orthopedic or traumatologic surgery. Many variable tips exist in several dimensions allowing to be used with a large range of screws. The handle is also available in different kind of shapes. The U-joint permits to screw in various axis orientations HXX Screwdriver 1 Hexagonal U-joint screwdriver 3.5mm, S / Z-H coupling
13 07640187913651 T2806 T2806 A hand-held re-usable surgical device designed to simultaneously direct the plac A hand-held re-usable surgical device designed to simultaneously direct the placement and angle of the drill hole and protect the surrounding tissue. It is cannulated to accept a dedicated drill bit size and has a serrated distal end to allow firm placement on the bone. The variable angle is from 25° to 65°. FZX Guide, Surgical, Instrument 1 Adjustable drill guide, Ø4.62 mm, 25° to 65°
14 07640187913316 T18022 T18022 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø48 with round tooth
15 07640187913224 T18013 T18013 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø39 with round tooth
16 07640187913088 T17827 T17827 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø70 with round tooth
17 07640187913002 T17819 T17819 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø62 with round tooth
18 07640187912869 T17805 T17805 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø48 with round tooth
19 07640187912777 T17796 T17796 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø39 with round tooth
20 07640187912630 T18243 T18243 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø70 with round tooth
21 07640187912555 T18235 T18235 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø62 with round tooth
22 07640187912418 T18221 T18221 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø48 with round tooth
23 07640187912326 T18212 T18212 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø39 with round tooth
24 07640187912104 T7552 T7552 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
25 07640187912098 T18189 T18189 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
26 07640187912067 T18161 T18161 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø16 x 483 mm, can. Ø3.1 mm Hudson coup.
27 07640187911862 T18152 T18152 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø7.5 x 475 mm, can. Ø3.1 mm Hudson coup.
28 07640187911848 T18379 T18379 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø16 x 30 mm, can. Ø3.1 mm
29 07640187911787 T18373 T18373 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø13 x 27 mm, can. Ø3.1 mm
30 07640187911435 T5357 T5357 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Big AO coup.
31 07640187911374 T4867 T4867 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø6.5 x 341 mm, can. Ø2.3 mm, Big AO coup.
32 07640187911329 T10309 T10309 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø24 x 39 mm, can. Ø3.4 mm
33 07640187911237 T3419 T3419 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø19.5 x 34 mm, can. Ø3.4 mm
34 07640187910520 T14585 T14585 A hammer with a mobile mass can be attached to the extraction clamp, as well as A hammer with a mobile mass can be attached to the extraction clamp, as well as on the hook. It permits to give the necessary impact to extract the knee implants. This is a reusable device. HXL Mallet 1 Slap hammer
35 07640187910490 T14587 T14587 Hook, in combination with the slap hammer, is intended to help the surgeon to pu Hook, in combination with the slap hammer, is intended to help the surgeon to pull/liberate the components in area where the access, due to soft tissues, is limited. When the instrument is placed at the femoral distal trochlea groove, it is ideal for pulling off the femoral implant. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Hook
36 07640187916874 T18382 T18382 Offset Reamer handles designed for required minimally invasive surgical approach Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. Various connections with reamer cutting tool and couplings with power tool (Big AO, Stryker-Zimmer/Hall and Harris) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Carbon offset reamer handle AO with parking
37 07640187916836 T10942 T10942 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø63
38 07640187916775 T10936 T10936 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø57
39 07640187915747 T7648 T7648 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
40 07640187913545 T18045 T18045 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø71 with round tooth
41 07640187914078 T17728 T17728 Offset Reamer handles designed for required minimally invasive surgical approach Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. A non clipped and dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Carbon offset reamer handle Stryker / Zimmer-Hall
42 07640187913521 T18043 T18043 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø69 with round tooth
43 07640187913972 T17780 T17780 Reamer handles designed for all required surgical approach of the hip joint. A d Reamer handles designed for all required surgical approach of the hip joint. A dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available.The handle could be disassembled allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Straight reamer handle AO dual coupling
44 07640187913941 T2288 T2288 The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. HTW Bit, Drill 1 Bayonet drill Ø3.2 x 52 mm
45 07640187913354 T18026 T18026 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø52 with round tooth
46 07640187913279 T18018 T18018 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø44 with round tooth
47 07640187913170 T17836 T17836 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø79 with round tooth
48 07640187913095 T17828 T17828 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø71 with round tooth
49 07640187913071 T17826 T17826 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø69 with round tooth
50 07640187912906 T17809 T17809 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø52 with round tooth
Other products with the same Product Code "LXH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00887761007499 101001BBG Single use device intended to cover exposed ends of orthopedic pin and k-wires t Single use device intended to cover exposed ends of orthopedic pin and k-wires to help protect the exposed wire from snagging on clothing. Oxboro™ Pin Cover ASPEN SURGICAL PRODUCTS, INC.
2 00887761003156 101003PBX Single use device intended to cover exposed ends of orthopedic pin and k-wires t Single use device intended to cover exposed ends of orthopedic pin and k-wires to help protect the exposed wire from snagging on clothing. Oxboro™ Pin Cover ASPEN SURGICAL PRODUCTS, INC.
3 00887761003149 101002PBX Single use device intended to cover exposed ends of orthopedic pin and k-wires t Single use device intended to cover exposed ends of orthopedic pin and k-wires to help protect the exposed wire from snagging on clothing. Oxboro™ Pin Cover ASPEN SURGICAL PRODUCTS, INC.
4 00887761003132 101001PBX Single use device intended to cover exposed ends of orthopedic pin and k-wires t Single use device intended to cover exposed ends of orthopedic pin and k-wires to help protect the exposed wire from snagging on clothing. Oxboro™ Pin Cover ASPEN SURGICAL PRODUCTS, INC.
5 00887761003125 101000PBX Single use device intended to cover exposed ends of orthopedic pin and k-wires t Single use device intended to cover exposed ends of orthopedic pin and k-wires to help protect the exposed wire from snagging on clothing. Oxboro™ Pin Cover ASPEN SURGICAL PRODUCTS, INC.
6 00887517999603 Z700146-104 CoRoent SI Trial Rasp, 4x15x12mm 7° Cont NuVasive NUVASIVE, INC.
7 00887517999597 Z700146-204 CoRoent SI Trial Rasp, 4x17x14mm 7° Cont NuVasive NUVASIVE, INC.
8 00887517999580 Z700146-305 CoRoent SI Trial Rasp, 5x17x12mm 7° Cont NuVasive NUVASIVE, INC.
9 00887517999573 Z700146-306 CoRoent SI Trial Rasp, 6x17x12mm 7° Cont NuVasive NUVASIVE, INC.
10 00887517999566 Z700146-307 CoRoent SI Trial Rasp, 7x17x12mm 7° Cont NuVasive NUVASIVE, INC.
11 00887517999559 Z700146-405 CoRoent SI Trial Rasp, 5x19x16mm 7° Cont NuVasive NUVASIVE, INC.
12 00887517999542 Z700146-406 CoRoent SI Trial Rasp, 6x19x16mm 7° Cont NuVasive NUVASIVE, INC.
13 00887517999535 Z700146-407 CoRoent SI Trial Rasp, 7x19x16mm 7° Cont NuVasive NUVASIVE, INC.
14 00887517999528 Z700146-505 CoRoent SI Trial Rasp, 5x19x14mm 7° Cont NuVasive NUVASIVE, INC.
15 00887517999511 Z700146-506 CoRoent SI Trial Rasp, 6x19x14mm 7° Cont NuVasive NUVASIVE, INC.
16 00887517999504 Z700146-507 CoRoent SI Trial Rasp, 7x19x14mm 7° Cont NuVasive NUVASIVE, INC.
17 00887517999498 Z700147-09 CoRoent SI Trial Drill Guide, 9mm Lordo NuVasive NUVASIVE, INC.
18 00887517999481 Z700147-10 CoRoent SI Trial Drill Guide, 10mm Lordo NuVasive NUVASIVE, INC.
19 00887517999474 Z700147-11 CoRoent SI Trial Drill Guide, 11mm Lordo NuVasive NUVASIVE, INC.
20 00887517999467 Z700147-12 CoRoent SI Trial Drill Guide, 12mm Lordo NuVasive NUVASIVE, INC.
21 00887517999443 Z700224-11 CoRoent SI Trial Guide, 11x17x14mm 10° NuVasive NUVASIVE, INC.
22 00887517999436 Z700224-12 CoRoent SI Trial Guide, 12x17x14mm 10° NuVasive NUVASIVE, INC.
23 00887517999429 Z700224-13 CoRoent SI Trial Guide, 13x17x14mm 10° NuVasive NUVASIVE, INC.
24 00887517999412 Z700224-14 CoRoent SI Trial Guide, 14x17x14mm 10° NuVasive NUVASIVE, INC.
25 00887517999405 Z700224-15 CoRoent SI Trial Guide, 15x17x14mm 10° NuVasive NUVASIVE, INC.
26 00887517999399 Z700224-16 CoRoent SI Trial Guide, 16x17x14mm 10° NuVasive NUVASIVE, INC.
27 00887517999382 Z700224-31 CoRoent SI Trial Guide, 11x17x14mm 15° NuVasive NUVASIVE, INC.
28 00887517999375 Z700224-32 CoRoent SI Trial Guide, 12x17x14mm 15° NuVasive NUVASIVE, INC.
29 00887517999368 Z700224-33 CoRoent SI Trial Guide, 13x17x14mm 15° NuVasive NUVASIVE, INC.
30 00887517999351 Z700224-34 CoRoent SI Trial Guide, 14x17x14mm 15° NuVasive NUVASIVE, INC.
31 00887517999344 Z700224-35 CoRoent SI Trial Guide, 15x17x14mm 15° NuVasive NUVASIVE, INC.
32 00887517999337 Z700224-36 CoRoent SI Trial Guide, 16x17x14mm 15° NuVasive NUVASIVE, INC.
33 00887517999320 Z700251-06 COHERE Trial Rasp, 6x12x4mm NuVasive NUVASIVE, INC.
34 00887517999313 Z700251-07 COHERE Trial Rasp, 7x12x4mm NuVasive NUVASIVE, INC.
35 00887517999306 Z700251-08 COHERE Trial Rasp, 8x12x4mm NuVasive NUVASIVE, INC.
36 00887517999290 Z700251-09 COHERE Trial Rasp, 9x12x4mm NuVasive NUVASIVE, INC.
37 00887517999283 Z700251-10 COHERE Trial Rasp, 10x12x4mm NuVasive NUVASIVE, INC.
38 00887517999276 Z113020-01 Swan Cobb - Superior NuVasive NUVASIVE, INC.
39 00887517999269 Z113020-02 Swan Cobb - Inferior NuVasive NUVASIVE, INC.
40 00887517999252 Z200161 Swan Paddle Sizer NuVasive NUVASIVE, INC.
41 00887517999245 Z200166-2 XL-TDR Angled Inserter - Crest Angle NuVasive NUVASIVE, INC.
42 00887517999238 Z200166-201 XL-TDR Angled Inserter-Crest Angle, Left NuVasive NUVASIVE, INC.
43 00887517999207 Z600093-1 Pedicle Marker System - Inserter NuVasive NUVASIVE, INC.
44 00887517998750 Z700161-106 CoRoent-S ACR Trial Rasp, 15x12x6mm 10° NuVasive NUVASIVE, INC.
45 00887517998743 Z700161-107 CoRoent-S ACR Trial Rasp, 15x12x7mm 10° NuVasive NUVASIVE, INC.
46 00887517998736 Z700161-108 CoRoent-S ACR Trial Rasp, 15x12x8mm 10° NuVasive NUVASIVE, INC.
47 00887517998729 Z700161-206 CoRoent-S ACR Trial Rasp, 15x12x6mm 15° NuVasive NUVASIVE, INC.
48 00887517998712 Z700161-207 CoRoent-S ACR Trial Rasp, 15x12x7mm 15° NuVasive NUVASIVE, INC.
49 00887517998705 Z700161-208 CoRoent-S ACR Trial Rasp, 15x12x8mm 15° NuVasive NUVASIVE, INC.
50 00887517996206 10001170 RELINE Driver, Adjustable Cam Lock ReLine NUVASIVE, INC.