The handle is proposed as accessory for the carbon offset reamer handles.This is
The handle is proposed as accessory for the carbon offset reamer handles.This is a reusable device.
Offset Reamer handles designed for required minimally invasive surgical approach
Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. Various connections with reamer cutting tool and couplings with power tool (Big AO, Stryker-Zimmer/Hall and Harris) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device.
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø10 x 348 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
A hand-held re-usable surgical device designed to tighten implantable screws int
A hand-held re-usable surgical device designed to tighten implantable screws into bones during orthopedic or traumatologic surgery. Many variable tips exist in several dimensions allowing to be used with a large range of screws. The handle is also available in different kind of shapes. The U-joint permits to screw in various axis orientations
HXX
Screwdriver
1
Hexagonal U-joint screwdriver 3.5mm, S / Z-H coupling
A hand-held re-usable surgical device designed to simultaneously direct the plac
A hand-held re-usable surgical device designed to simultaneously direct the placement and angle of the drill hole and protect the surrounding tissue. It is cannulated to accept a dedicated drill bit size and has a serrated distal end to allow firm placement on the bone. The variable angle is from 25° to 65°.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø16 x 483 mm, can. Ø3.1 mm Hudson coup.
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
HTO
Reamer
1
Femoral IM reamer Ø7.5 x 475 mm, can. Ø3.1 mm Hudson coup.
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø16 x 30 mm, can. Ø3.1 mm
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø13 x 27 mm, can. Ø3.1 mm
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Big AO coup.
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø6.5 x 341 mm, can. Ø2.3 mm, Big AO coup.
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø24 x 39 mm, can. Ø3.4 mm
Intramedullary reamer head is used in combination with the Intramedullary reamer
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
HTO
Reamer
1
IM reamer head dove tail Ø19.5 x 34 mm, can. Ø3.4 mm
A hammer with a mobile mass can be attached to the extraction clamp, as well as
A hammer with a mobile mass can be attached to the extraction clamp, as well as on the hook. It permits to give the necessary impact to extract the knee implants. This is a reusable device.
Hook, in combination with the slap hammer, is intended to help the surgeon to pu
Hook, in combination with the slap hammer, is intended to help the surgeon to pull/liberate the components in area where the access, due to soft tissues, is limited. When the instrument is placed at the femoral distal trochlea groove, it is ideal for pulling off the femoral implant. This is a reusable device.
Offset Reamer handles designed for required minimally invasive surgical approach
Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. Various connections with reamer cutting tool and couplings with power tool (Big AO, Stryker-Zimmer/Hall and Harris) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device.
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h
Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device.
HTO
Reamer
1
Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
Offset Reamer handles designed for required minimally invasive surgical approach
Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. A non clipped and dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device.
Reamer handles designed for all required surgical approach of the hip joint. A d
Reamer handles designed for all required surgical approach of the hip joint. A dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available.The handle could be disassembled allowing the cleaning of the instrument. This is a reusable device.
The drills with a transversal pin, permitting the transmission of the torque, ar
The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool.
To minimize soft tissue damage, two different size displacers have been included
To minimize soft tissue damage, two different size displacers have been included in the kit. The two parts are slotted together and then pushed through the soft tissue until the bone is reached. The central part of the displacer can then be removed, and the tube saw can be inserted. This will stop the saw teeth from ‘snagging’ on and damaging the soft tissue and thus help reduce the recovery time.
To minimize soft tissue damage, two different size displacers have been included
To minimize soft tissue damage, two different size displacers have been included in the kit. The two parts are slotted together and then pushed through the soft tissue until the bone is reached. The central part of the displacer can then be removed, and the tube saw can be inserted. This will stop the saw teeth from ‘snagging’ on and damaging the soft tissue and thus help reduce the recovery time.
Can be used to (1) stabilize the guide in the place, preventing the bone from mo
Can be used to (1) stabilize the guide in the place, preventing the bone from moving, and (2) help disassemble the ergonomic torque handle from the tube saw.
To prevent the bones from moving while they are being cut, a jig has been includ
To prevent the bones from moving while they are being cut, a jig has been included. K-wires are passed through the jig and are then drilled into each carpal bone. The tube saw can then be passed through the centre and the cut made.
To prevent the bones from moving while they are being cut, a jig has been includ
To prevent the bones from moving while they are being cut, a jig has been included. K-wires are passed through the jig and are then drilled into each carpal bone. The tube saw can then be passed through the centre and the cut made.
A spike has been included in the kit, this is to be inserted through the body of
A spike has been included in the kit, this is to be inserted through the body of the tube saw and is used to centralize the saw when starting the cut.
A spike has been included in the kit, this is to be inserted through the body of
A spike has been included in the kit, this is to be inserted through the body of the tube saw and is used to centralize the saw when starting the cut.
The graft extractors are used to remove the ‘plug’ of bone from the end of the t
The graft extractors are used to remove the ‘plug’ of bone from the end of the tube saw after it has been removed.
The graft extractors are used to remove the ‘plug’ of bone from the end of the t
The graft extractors are used to remove the ‘plug’ of bone from the end of the tube saw after it has been removed.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, a
The 8 tube saws, ranging from 6.5mm Outside Diameter to 17mm Outside Diameter, are sized so that the inside diameter of the larger saw will cut a dowel that will compression fit into the hole formed by the outer diameter of the next size down. The saws and the accompanying instrumentation will allow accurate removal of damaged arthritic bone and insertion of a healthy bone dowel to encourage fusion.