Other products from "MPS PRECIMED SA"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07640187916652 T10924 T10924 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø45
2 07640187914092 T18180 T18180 The handle is proposed as accessory for the carbon offset reamer handles.This is The handle is proposed as accessory for the carbon offset reamer handles.This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Handle for carbon offset reamer handle
3 07640187913538 T18044 T18044 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø70 with round tooth
4 07640187913620 T18053 T18053 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø79 with round tooth
5 07640187916867 T18381 T18381 Offset Reamer handles designed for required minimally invasive surgical approach Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. Various connections with reamer cutting tool and couplings with power tool (Big AO, Stryker-Zimmer/Hall and Harris) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Carbon offset reamer handle Harris with parking
6 07640187916829 T10941 T10941 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø62
7 07640187916782 T10937 T10937 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø58
8 07640187916751 T10934 T10934 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø55
9 07640187916744 T10933 T10933 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø54
10 07640187916621 T10921 T10921 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø42
11 07640187915754 T7649 T7649 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø10 x 348 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
12 07640187913453 T18036 T18036 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø62 with round tooth
13 07640187914290 T12632 T12632 A hand-held re-usable surgical device designed to tighten implantable screws int A hand-held re-usable surgical device designed to tighten implantable screws into bones during orthopedic or traumatologic surgery. Many variable tips exist in several dimensions allowing to be used with a large range of screws. The handle is also available in different kind of shapes. The U-joint permits to screw in various axis orientations HXX Screwdriver 1 Hexagonal U-joint screwdriver 3.5mm, S / Z-H coupling
14 07640187913651 T2806 T2806 A hand-held re-usable surgical device designed to simultaneously direct the plac A hand-held re-usable surgical device designed to simultaneously direct the placement and angle of the drill hole and protect the surrounding tissue. It is cannulated to accept a dedicated drill bit size and has a serrated distal end to allow firm placement on the bone. The variable angle is from 25° to 65°. FZX Guide, Surgical, Instrument 1 Adjustable drill guide, Ø4.62 mm, 25° to 65°
15 07640187913316 T18022 T18022 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø48 with round tooth
16 07640187913224 T18013 T18013 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø39 with round tooth
17 07640187913088 T17827 T17827 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø70 with round tooth
18 07640187913002 T17819 T17819 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø62 with round tooth
19 07640187912869 T17805 T17805 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø48 with round tooth
20 07640187912777 T17796 T17796 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø39 with round tooth
21 07640187912630 T18243 T18243 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø70 with round tooth
22 07640187912555 T18235 T18235 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø62 with round tooth
23 07640187912418 T18221 T18221 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø48 with round tooth
24 07640187912326 T18212 T18212 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø39 with round tooth
25 07640187912104 T7552 T7552 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
26 07640187912098 T18189 T18189 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
27 07640187912067 T18161 T18161 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø16 x 483 mm, can. Ø3.1 mm Hudson coup.
28 07640187911862 T18152 T18152 Femoral monobloc intramedullary reamer is used to ream the medullary cavity of f Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. HTO Reamer 1 Femoral IM reamer Ø7.5 x 475 mm, can. Ø3.1 mm Hudson coup.
29 07640187911848 T18379 T18379 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø16 x 30 mm, can. Ø3.1 mm
30 07640187911787 T18373 T18373 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø13 x 27 mm, can. Ø3.1 mm
31 07640187911435 T5357 T5357 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Big AO coup.
32 07640187911374 T4867 T4867 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø6.5 x 341 mm, can. Ø2.3 mm, Big AO coup.
33 07640187911329 T10309 T10309 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø24 x 39 mm, can. Ø3.4 mm
34 07640187911237 T3419 T3419 Intramedullary reamer head is used in combination with the Intramedullary reamer Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable. HTO Reamer 1 IM reamer head dove tail Ø19.5 x 34 mm, can. Ø3.4 mm
35 07640187910520 T14585 T14585 A hammer with a mobile mass can be attached to the extraction clamp, as well as A hammer with a mobile mass can be attached to the extraction clamp, as well as on the hook. It permits to give the necessary impact to extract the knee implants. This is a reusable device. HXL Mallet 1 Slap hammer
36 07640187910490 T14587 T14587 Hook, in combination with the slap hammer, is intended to help the surgeon to pu Hook, in combination with the slap hammer, is intended to help the surgeon to pull/liberate the components in area where the access, due to soft tissues, is limited. When the instrument is placed at the femoral distal trochlea groove, it is ideal for pulling off the femoral implant. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Hook
37 07640187916874 T18382 T18382 Offset Reamer handles designed for required minimally invasive surgical approach Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. Various connections with reamer cutting tool and couplings with power tool (Big AO, Stryker-Zimmer/Hall and Harris) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Carbon offset reamer handle AO with parking
38 07640187916836 T10942 T10942 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø63
39 07640187916775 T10936 T10936 Acetabular reamer for hip arthroplasty HTO Reamer 1 Penenberg's acetabular reamer Ø57
40 07640187915747 T7648 T7648 Humeral monobloc intramedullary reamer is used to ream the medullary cavity of h Humeral monobloc intramedullary reamer is used to ream the medullary cavity of humeral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool. This is a reusable device. HTO Reamer 1 Humeral IM reamer Ø9.5 x 347 mm, can. Ø2.3 mm, Stryker/Zimmer-Hall coup.
41 07640187913545 T18045 T18045 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø71 with round tooth
42 07640187914078 T17728 T17728 Offset Reamer handles designed for required minimally invasive surgical approach Offset Reamer handles designed for required minimally invasive surgical approach of the hip joint. A non clipped and dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available. It could be disassembled in 5 parts allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Carbon offset reamer handle Stryker / Zimmer-Hall
43 07640187913521 T18043 T18043 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø69 with round tooth
44 07640187913972 T17780 T17780 Reamer handles designed for all required surgical approach of the hip joint. A d Reamer handles designed for all required surgical approach of the hip joint. A dual connection with reamer cutting tool and 3 couplings with power tool (Big AO, Stryker-Zimmer/Hall and Hudson) are available.The handle could be disassembled allowing the cleaning of the instrument. This is a reusable device. LXH Orthopedic Manual Surgical Instrument 1 Straight reamer handle AO dual coupling
45 07640187913941 T2288 T2288 The drills with a transversal pin, permitting the transmission of the torque, ar The drills with a transversal pin, permitting the transmission of the torque, are re-usable rotary cutting instruments used in surgery for drilling cylindrical holes into bone. The cutting action is determined by the cutting edges. A range of diameter and length is proposed.The drills are used with a power tool. HTW Bit, Drill 1 Bayonet drill Ø3.2 x 52 mm
46 07640187913354 T18026 T18026 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø52 with round tooth
47 07640187913279 T18018 T18018 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø44 with round tooth
48 07640187913170 T17836 T17836 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø79 with round tooth
49 07640187913095 T17828 T17828 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø71 with round tooth
50 07640187913071 T17826 T17826 Acetabular reamer for hip arthroplasty HTO Reamer 1 Acetabular reamer Ø69 with round tooth
Other products with the same Product Code "HTW"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04046963371739 GC479R GC479R CRANIOPLATE 1.5 DRILL D:1.1 L:5 DENTAL CRANIOPLATE AESCULAP AG
2 04046963371722 GC478R GC478R CRANIOPLATE 1.5 DRILL D:1.1 L:3 DENTAL CRANIOPLATE AESCULAP AG
3 04046963313104 FW092SU FW092SU S4C OCCIPUT DRILL BIT D3.9MM S4 CERVICAL AESCULAP AG
4 04046963313098 FW091SU FW091SU S4C OCCIPUT DRILL BIT D2.9MM S4 CERVICAL AESCULAP AG
5 04046955280124 ND005NR ND005NR FEMORAL HEAD EXTRACTION DRILL SQ.LINE AESCULAP AG
6 04046955196227 ME403R ME403R ARCADIUS XP C BALL JOINT DRILL ARCADIUS XP C AESCULAP IMPLANT SYSTEMS, LLC
7 04042409403644 IU 7420-13-1U IU 7420-13-1U Twist drill ø2.0, L 130, coil 30, quick coupling single use NA AAP IMPLANTATE AG
8 04042409401664 IU 7020-05-1U Drill CS 2.7, ø2.0, L 105, quick coupling, single use NA AAP IMPLANTATE AG
9 04042409401657 IU 7017-05-1U Drill CS 2.0, ø1.7, L 105, quick coupling, single use NA AAP IMPLANTATE AG
10 04042409401640 IU 7020-05 Drill CS 2.7, ø2.0, L 105, quick coupling, sterile NA AAP IMPLANTATE AG
11 04042409401633 IU 7017-05 Drill CS 2.0, ø1.7, L 105, quick coupling, sterile NA AAP IMPLANTATE AG
12 04042409397516 IU 7420-16-1U Twist drill ø2.0, L 150, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
13 04042409397509 IU 7420-16 Twist drill ø2.0, L 150, coil 50, quick coupling NA AAP IMPLANTATE AG
14 04042409396458 IU 7427-23-1U Twist drill ø2.7, L 220, quick coupling, scaled, single use NA AAP IMPLANTATE AG
15 04042409396441 IU 7427-16-1U Twist drill ø2.7, L 150, quick coupling, scaled, single use NA AAP IMPLANTATE AG
16 04042409386565 IU 7420-18-1U Twist drill ø2.0, L 180, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
17 04042409384547 IU 7427-23 Twist drill ø2.7, L 220, coil 50, quick coupling, scaled NA AAP IMPLANTATE AG
18 04042409384530 IU 7427-16 Twist drill ø2.7, L 150, coil 50, quick coupling, scaled NA AAP IMPLANTATE AG
19 04042409382680 IU 7438-22-1U Twist drill ø3.8, L 220, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
20 04042409382673 IU 7438-22 Twist drill ø3.8, L 220, coil 50, quick coupling NA AAP IMPLANTATE AG
21 04042409382406 IU 7020-13-1U Drill CS 2.7, ø2.0, L 85, quick coupling, single use NA AAP IMPLANTATE AG
22 04042409382390 IU 7017-13-1U Drill CS 2.0, ø1.7, L 85, quick coupling, single use NA AAP IMPLANTATE AG
23 04042409380914 IU 7420-15-1U Twist drill ø2.0, L 150, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
24 04042409364174 IU 7420-11-1U Twist drill ø2.0, L 110, coil 30, quick coupling, single use NA AAP IMPLANTATE AG
25 04042409364167 IU 7420-11 Twist drill ø2.0, L 110, coil 30, quick coupling NA AAP IMPLANTATE AG
26 04042409363849 IU 7427-20-1U Twist drill ø2.7, L 200, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
27 04042409363832 IU 7427-20 Twist drill ø2.7, L 200, coil 50, quick coupling NA AAP IMPLANTATE AG
28 04042409360138 IU 7420-10-1U Twist drill ø2.0, L 110, coil 25, quick coupling, single use NA AAP IMPLANTATE AG
29 04042409340031 IU 7438-20-1U Twist drill ø3.8, L 200, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
30 04042409340024 IU 7438-20 Twist drill ø3.8, L 200, coil 50, quick coupling NA AAP IMPLANTATE AG
31 04042409331732 IU 7535-00-1U Twist drill ø3.5, L 95, coil 50, Jacobs chuck, single use NA AAP IMPLANTATE AG
32 04042409331725 IU 7525-00-1U Twist drill ø2.5, L 95, coil 50, Jacobs chuck, single use NA AAP IMPLANTATE AG
33 04042409259296 10-017 Cannulated drill CS 5.8, ø4.3, L 220, Hudson, single use NA AAP IMPLANTATE AG
34 04042409259289 10-016 Cannulated drill CS 7.5, ø5.0, L 220, Hudson, single use NA AAP IMPLANTATE AG
35 04042409259043 IU 7058-22-1U Drill CS 5.8, ø4.3, L 220, I-ø 2.2, Hudson, single use NA AAP IMPLANTATE AG
36 04042409256790 IU 7423-18-1U Twist drill ø2.3, L 180, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
37 04042409255496 IU 7427-22-1U Twist drill ø2.7, L 220, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
38 04042409255151 IU 7445-00-1U Twist drill ø4.5, L 145, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
39 04042409255144 IU 7438-33-1U Twist drill ø3.8, L 310, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
40 04042409255137 IU 7438-25-1U Twist drill ø3.8, L 250, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
41 04042409255120 IU 7438-18-1U Twist drill ø3.8, L 180, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
42 04042409255113 IU 7435-00-1U Twist drill ø3.5, L 110, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
43 04042409255106 IU 7432-33-1U Twist drill ø3.2, L 310, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
44 04042409255090 IU 7432-30-1U Twist drill ø3.2, L 195, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
45 04042409255083 IU 7432-00-1U Twist drill ø3.2, L 145, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
46 04042409255076 IU 7427-15-1U Twist drill ø2.7, L 150, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
47 04042409255069 IU 7427-00-1U Twist drill ø2.7, L 100, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
48 04042409255052 IU 7425-18-1U Twist drill ø2.5, L 180, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
49 04042409255038 IU 7425-00-1U Twist drill ø2.5, L 110, coil 50, quick coupling, single use NA AAP IMPLANTATE AG
50 04042409255007 IU 7420-00-1U Twist drill ø2.0, L 100, coil 50, quick coupling, single use NA AAP IMPLANTATE AG