No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07640121880902 RFT100VA-V1 Isolates the SDM from mains for use in home use environments. LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Isolation Transformer 100-120V
2 07640121880773 V-STATS_CD PC based software required a) to configure special (safety-relevant) settings of PC based software required a) to configure special (safety-relevant) settings of the SenTec Digital Monitor (SDM), b) to manage ‘SDM Parameters Settings’ and c) to download trend data from the internal memory of the SDM to a PC. It includes features to analyze and view the downloaded trend data. The V-STATS™ software includes the V-CareNeT™ Package, which enables remote monitoring and alarm surveillance for multiple SDMs being connected to the same network as the PC with V-STATS™. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 V-STATS™ Installation CD
3 07640121880766 PSG Cable P The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable P
4 07640121880438 SSET-N Neonatal Starter Set contains:Multi-Site Attachment Rings for mature/intact skin Neonatal Starter Set contains:Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Neonatal Starter Set
5 07640121880315 PSG-X The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG-X
6 07640121880087 MC-R The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC-R) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. To enable an economic and cost saving membrane change, the Membrane Changer after use can be reloaded with a new Membrane Changer Insert (MC-I). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Membrane Changer (reloadable) / single unit
7 07640121880964 PAK-MI A combination of single-use products intended to attach the Sentec sensors to co A combination of single-use products intended to attach the Sentec sensors to conventional measurement sites, recommended for adult, pediatric and neonatal patients with mature/intact skin KLK,LKD,LPP,DPZ,DQA Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon- Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Oximeter, Ear,Oximeter 2 Patient Application Kit for mature intact skin
8 07640121880643 PSG Cable D The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable D
9 17640121880862 GEL-SD The Contact Gel is required for proper CO2 gas conduction from the patient's Ski The Contact Gel is required for proper CO2 gas conduction from the patient's Skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor Membrane. GEL-SD is delivered in single dose vials each containing 0.3 g of the solution and is intended for single use. LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Contact Gel
10 07640121880698 PSG Cable J The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable J
11 07640121880933 MC The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. The MC is single-use. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Membrane Changer (single-use) / single unit
12 07640121880810 ECe-MI Single patient use sensor application ear clip, recommended for adult, pediatric Single patient use sensor application ear clip, recommended for adult, pediatric and neonatal patients with mature/intact skin LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Ear Clip easy
13 07640121880797 MARe-MI Single use sensor application ring, recommended for adult, pediatric and neonata Single use sensor application ring, recommended for adult, pediatric and neonatal patients with mature/intact skin LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Multi-Site Attachment Ring for mature/intact skin
14 07640121880636 PSG Cable C The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable C
15 07640121880223 MAR-MI MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for patients with mature, intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Multi-Site Attachment Ring for mature/intact skin
16 07640121880070 GEL-04 The Contact Gel is required for proper CO2 gas conduction from the patient’s ski The Contact Gel is required for proper CO2 gas conduction from the patient’s skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor membrane. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Contact Gel
17 07640121880957 PAK-EC A combination of single-use products intended to attach the Sentec sensors to th A combination of single-use products intended to attach the Sentec sensors to the earlobe of the patient, recommended for patients with mature/intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Patient Application Kit with Ear Clip for mature/intact skin
18 07640121880681 PSG Cable H The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable H
19 07640121880568 SA-MAR The Staysite Adhesive (SA-MAR), is an optional, single-use adhesive which is ind The Staysite Adhesive (SA-MAR), is an optional, single-use adhesive which is indicated for use with Multi-Site Attachment Rings, models MAR-MI and MAR-SF if more secure attachment is required. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Staysite Adhesive
20 07640121880308 SSET_nG Standard Starter Set (without Service Gas) contains:Ear Clips (EC-MI)Multi-Site Standard Starter Set (without Service Gas) contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04) DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Standard Starter Set (without Service Gas)
21 07640121880803 MARe-SF Single use sensor application ring, recommended for adult, pediatric and neonata Single use sensor application ring, recommended for adult, pediatric and neonatal patients with sensitive/fragile skin LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Multi-Site Attachment Ring for fragile/sensitive skin
22 07640121880728 PSG Cable M The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG). LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable M
23 07640121880667 PSG Cable F The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable F
24 07640121880506 MC-I The Membrane Changer (MC-R) is a reloadable tool to change the membrane of SenTe The Membrane Changer (MC-R) is a reloadable tool to change the membrane of SenTec TC Sensors. Prior reuse, the Membrane Changer (MC-R) must be reloaded with a new Membrane Changer Insert (MC-I). The MC-I is single-use DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Membrane Changer Inserts
25 07640121880445 SSET-N_nG Neonatal Starter Set (without Service Gas) contains:Multi-Site Attachment Rings Neonatal Starter Set (without Service Gas) contains:Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) DQA,DPZ,KLK,LKD,LPP Oximeter,Oximeter, Ear,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter,Oximeter, Ear,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Neonatal Starter Set (without Service Gas)
26 07640121880230 MAR-SF MAR-SF is intended to attach SenTec TC Sensors to various measurement sites for MAR-SF is intended to attach SenTec TC Sensors to various measurement sites for patients with sensitive, fragile but intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Multi-Site Attachment Ring for fragile/sensitive skin
27 07640121880094 SSET Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for m Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) LPP,KLK,DQA,DPZ,LKD Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear,Monitor, Carbon-Dioxide, Cutaneous 2 Standard Starter Set
28 07640121880049 EC-MI The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. S The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. Suitable for patients with earlobes of sufficient size and mature, intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Ear Clip
29 07640121880032 AC-150 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Digital Sensor Adapter Cable, 150 cm
30 07640121880889 SDM_WPC This cover will protect the SenTec Digital Monitor (SDM) from dripping water whe This cover will protect the SenTec Digital Monitor (SDM) from dripping water when the device is tilted up to 15° (IPX2). LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 SDM Water Protection Cover
31 07640121880858 GEL-04 The Contact Gel is required for proper CO2 gas conduction from the patient's ski The Contact Gel is required for proper CO2 gas conduction from the patient's skin to the SenTec TC Sensors. Every time a SenTec TC Sensor is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor membrane. LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Contact Gel 2ml
32 07640121880759 SDM-PO2 Stand alone monitor with colour display for continuous non-invasive vital parame Stand alone monitor with colour display for continuous non-invasive vital parameter monitoring, with integrated docking station for sensor storage and calibration. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 SenTec Digital Monitor (with activated PO2 channel)
33 07640121880735 PSG Cable N The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable N
34 07640121880674 PSG Cable G The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable G
35 07640121880650 PSG Cable E The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable E
36 07640121880629 PSG Cable B The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable B
37 07640121880490 MC-SET The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC-R) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. To enable an economic and cost saving membrane change, the Membrane Changer after use can be reloaded with a new Membrane Changer Insert (MC-I). The memrane changer set contains the MC-R and inserts (MC-I) to reload.Membrane Changer Set [1 membrane changer, 1 insert] DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Membrane Changer Set
38 07640121880162 AC-250 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Digital Sensor Adapter Cable, 250 cm
39 07640121880056 GAS-0812 The Service Gas is required for the calibration of the PCO2-part of SenTec TC Se The Service Gas is required for the calibration of the PCO2-part of SenTec TC Sensors. Depending on usage of the SDMS one Service Gas cylinder lasts for approx. 3 to 4 weeks. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Service gas
40 07640121880971 PAK-SF A combination of single-use products intended to attach the Sentec Sensors to co A combination of single-use products intended to attach the Sentec Sensors to conventional measurement sites, recommended for adult, pediatric and neonatal patients with sensitive/fragile skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Patient Application Kit for sensitive/fragile skin
41 07640121880742 OV-A/P/N Digital Sensor for non-invasive and continuous measurement of transcutaneous car Digital Sensor for non-invasive and continuous measurement of transcutaneous carbon dioxide and oxygen partial pressure as well as pulse oximetry. Suitable for adult, pediatric and neonatal patients. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 OxiVenT™ Sensor
42 07640121880711 PSG Cable L The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG). LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable L
43 07640121880513 VS-A/P/N Digital Sensor for non-invasive and continuous measurement of transcutaneous car Digital Sensor for non-invasive and continuous measurement of transcutaneous carbon dioxide partial pressure and pulse oximetry. Suitable for adult, pediatric and neonatal patients. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 V-Sign™ Sensor 2
44 07640121880179 AC-750 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Digital Sensor Adapter Cable, 750 cm
45 07640121880612 PSG Cable A The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable A
46 07640121880018 SDM Stand alone monitor with colour display for continuous non-invasive vital parame Stand alone monitor with colour display for continuous non-invasive vital parameter monitoring, with integrated docking station for sensor storage and calibration. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 SenTec Digital Monitor (without activated PO2 channel)
Other products with the same Product Codes "LPP, LKD, KLK, DQA, DPZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 17640121880862 GEL-SD The Contact Gel is required for proper CO2 gas conduction from the patient's Ski The Contact Gel is required for proper CO2 gas conduction from the patient's Skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor Membrane. GEL-SD is delivered in single dose vials each containing 0.3 g of the solution and is intended for single use. Contact Gel SENTEC AG
2 17640121880862 GEL-SD The Contact Gel is required for proper CO2 gas conduction from the patient's Ski The Contact Gel is required for proper CO2 gas conduction from the patient's Skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor Membrane. GEL-SD is delivered in single dose vials each containing 0.3 g of the solution and is intended for single use. Contact Gel SENTEC AG
3 17640121880862 GEL-SD The Contact Gel is required for proper CO2 gas conduction from the patient's Ski The Contact Gel is required for proper CO2 gas conduction from the patient's Skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor Membrane. GEL-SD is delivered in single dose vials each containing 0.3 g of the solution and is intended for single use. Contact Gel SENTEC AG
4 17640121880862 GEL-SD The Contact Gel is required for proper CO2 gas conduction from the patient's Ski The Contact Gel is required for proper CO2 gas conduction from the patient's Skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor Membrane. GEL-SD is delivered in single dose vials each containing 0.3 g of the solution and is intended for single use. Contact Gel SENTEC AG
5 17640121880862 GEL-SD The Contact Gel is required for proper CO2 gas conduction from the patient's Ski The Contact Gel is required for proper CO2 gas conduction from the patient's Skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor Membrane. GEL-SD is delivered in single dose vials each containing 0.3 g of the solution and is intended for single use. Contact Gel SENTEC AG
6 17290018446154 N9+ Nonagon N9+ NONAGON LTD
7 15700693095285 0640210 0640210 CAL gas 6 cyl. Calibration Gas RADIOMETER BASEL AG
8 15700693095285 0640210 0640210 CAL gas 6 cyl. Calibration Gas RADIOMETER BASEL AG
9 15700693095285 0640210 0640210 CAL gas 6 cyl. Calibration Gas RADIOMETER BASEL AG
10 15700693095285 0640210 0640210 CAL gas 6 cyl. Calibration Gas RADIOMETER BASEL AG
11 15694311111467 NOX-T3S_USF 511112 Nox T3s System NOX MEDICAL EHF.
12 15694311110804 NOX-T3D_USF 511119 Nox T3® Demo System with WristOx2 NOX MEDICAL EHF.
13 15694311110569 NOX-T3_USF 511110 Nox T3® System with WristOx2 NOX MEDICAL EHF.
14 15019517069419 6015R BCI SMITHS MEDICAL MD, INC.
15 15019517053708 3375 BCI SMITHS MEDICAL MD, INC.
16 15019517043051 3419 BCI SMITHS MEDICAL ASD, INC.
17 15019517043044 WW3350 BCI SMITHS MEDICAL ASD, INC.
18 15019517043037 3178 BCI SMITHS MEDICAL MD, INC.
19 15019517042511 1303 BCI SMITHS MEDICAL MD, INC.
20 15019517042504 1302 BCI SMITHS MEDICAL MD, INC.
21 15019517042498 1301 BCI SMITHS MEDICAL MD, INC.
22 10889483007532 9-6001-00 SunMed Finger Pulse Oximeter with Case Sunmed SUNMED, LLC
23 M745CBSP2 CBSP2 CBSP2 CBSP2 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
24 M745CBSP1 CBSP1 CBSP1 CBSP1 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
25 M745CBHPN1 CBHPN1 CBHPN1 CBHPN1 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
26 M745CBHPHP1 CBHPHP1 CBHPHP1 CBHPHP1 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
27 M745CB10641 CB10641 CB10641 CB10641 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
28 M745CB10640 CB10640 CB10640 CB10640 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
29 M745CB10639 CB10639 CB10639 CB10639 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
30 M745CB10590 CB10590 CB10590 CB10590 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
31 M745CB10588 CB10588 CB10588 CB10588 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
32 M745CB10587 CB10587 CB10587 CB10587 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
33 M745CB10586 CB10586 CB10586 CB10586 - Pulse Oximeter Adapter Cable AIV AMERICAN IV PRODUCTS, INC.
34 10888277400726 HCSM70P HCSM70P OXIMETER,PULSE,FINGERCLIP, PEDIATRIC Medline MEDLINE INDUSTRIES, INC.
35 10885632143977 CL9101 Cable Extension/Adapter SpO2 2.2m Nellcor Drager Compatible Reusable Not Made Wi Cable Extension/Adapter SpO2 2.2m Nellcor Drager Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
36 10885632143656 CL8104 Cable Extension/Adapter SpO2 2.2m Masimo *REF* Compatible Reusable Not Made With Cable Extension/Adapter SpO2 2.2m Masimo *REF* Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
37 10885632143649 CL7502 Cable Trusignal Interconnect SpO2 Datex Connector 2.2m Reusable Not Made With Na Cable Trusignal Interconnect SpO2 Datex Connector 2.2m Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
38 10885632143625 CL7308 Sensor SpO2 3.0m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex Sensor SpO2 3.0m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
39 10885632143618 CL7307 Sensor SpO2 Ear Clip 1.1m Ge Datex Compatible Reusable Not Made With Natural Rub Sensor SpO2 Ear Clip 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
40 10885632143601 CL7306 Sensor SpO2 3.0m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex Sensor SpO2 3.0m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
41 10885632143595 CL7304 Sensor SpO2 Ear Clip 1.1m Ge Datex Compatible Reusable Not Made With Natural Rub Sensor SpO2 Ear Clip 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
42 10885632143588 CL7303 Sensor SpO2 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex Sensor SpO2 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
43 10885632143571 CL7302 Sensor SpO2 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex Sensor SpO2 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
44 10885632143564 CL7301 Sensor SpO2 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex Sensor SpO2 1.1m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
45 10885632143526 CL7103 Cable Extension/Adapter SpO2 2.2m Ge Datex Compatible Reusable Not Made With Nat Cable Extension/Adapter SpO2 2.2m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
46 10885632143519 CL7102 Cable Extension/Adapter SpO2 2.2m Ge Datex Compatible Reusable Not Made With Nat Cable Extension/Adapter SpO2 2.2m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
47 10885632143502 CL7101 Cable Extension/Adapter SpO2 2.2m Ge Datex Compatible Reusable Not Made With Nat Cable Extension/Adapter SpO2 2.2m Ge Datex Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
48 10885632143496 CL6305 Sensor SpO2 Ear 1.1m Masimo Lncs TC-1 Compatible Reusable Not Made With Natural Sensor SpO2 Ear 1.1m Masimo Lncs TC-1 Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
49 10885632143489 CL6304 Sensor SpO2 Pediatric 1.1m Masimo Compatible Reusable Not Made With Natural Rubb Sensor SpO2 Pediatric 1.1m Masimo Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.
50 10885632143472 CL6302 Sensor SpO2 Pediatric 1.1m Masimo Compatible Reusable Not Made With Natural Rubb Sensor SpO2 Pediatric 1.1m Masimo Compatible Reusable Not Made With Natural Rubber Latex MediChoice Medichoice OWENS & MINOR DISTRIBUTION, INC.