No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07640121880902 RFT100VA-V1 Isolates the SDM from mains for use in home use environments. LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Isolation Transformer 100-120V
2 07640121880773 V-STATS_CD PC based software required a) to configure special (safety-relevant) settings of PC based software required a) to configure special (safety-relevant) settings of the SenTec Digital Monitor (SDM), b) to manage ‘SDM Parameters Settings’ and c) to download trend data from the internal memory of the SDM to a PC. It includes features to analyze and view the downloaded trend data. The V-STATS™ software includes the V-CareNeT™ Package, which enables remote monitoring and alarm surveillance for multiple SDMs being connected to the same network as the PC with V-STATS™. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 V-STATS™ Installation CD
3 07640121880766 PSG Cable P The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable P
4 07640121880438 SSET-N Neonatal Starter Set contains:Multi-Site Attachment Rings for mature/intact skin Neonatal Starter Set contains:Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Neonatal Starter Set
5 07640121880315 PSG-X The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG-X
6 07640121880087 MC-R The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC-R) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. To enable an economic and cost saving membrane change, the Membrane Changer after use can be reloaded with a new Membrane Changer Insert (MC-I). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Membrane Changer (reloadable) / single unit
7 07640121880704 PSG Cable K The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable K
8 07640121880964 PAK-MI A combination of single-use products intended to attach the Sentec sensors to co A combination of single-use products intended to attach the Sentec sensors to conventional measurement sites, recommended for adult, pediatric and neonatal patients with mature/intact skin KLK,LKD,LPP,DPZ,DQA Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon- Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Oximeter, Ear,Oximeter 2 Patient Application Kit for mature intact skin
9 07640121880643 PSG Cable D The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable D
10 17640121880862 GEL-SD The Contact Gel is required for proper CO2 gas conduction from the patient's Ski The Contact Gel is required for proper CO2 gas conduction from the patient's Skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor Membrane. GEL-SD is delivered in single dose vials each containing 0.3 g of the solution and is intended for single use. LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Contact Gel
11 07640121880698 PSG Cable J The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable J
12 07640121880933 MC The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. The MC is single-use. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Membrane Changer (single-use) / single unit
13 07640121880810 ECe-MI Single patient use sensor application ear clip, recommended for adult, pediatric Single patient use sensor application ear clip, recommended for adult, pediatric and neonatal patients with mature/intact skin LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Ear Clip easy
14 07640121880797 MARe-MI Single use sensor application ring, recommended for adult, pediatric and neonata Single use sensor application ring, recommended for adult, pediatric and neonatal patients with mature/intact skin LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Multi-Site Attachment Ring for mature/intact skin
15 07640121880636 PSG Cable C The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable C
16 07640121880223 MAR-MI MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for patients with mature, intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Multi-Site Attachment Ring for mature/intact skin
17 07640121880070 GEL-04 The Contact Gel is required for proper CO2 gas conduction from the patient’s ski The Contact Gel is required for proper CO2 gas conduction from the patient’s skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor membrane. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Contact Gel
18 07640121880957 PAK-EC A combination of single-use products intended to attach the Sentec sensors to th A combination of single-use products intended to attach the Sentec sensors to the earlobe of the patient, recommended for patients with mature/intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Patient Application Kit with Ear Clip for mature/intact skin
19 07640121880681 PSG Cable H The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable H
20 07640121880568 SA-MAR The Staysite Adhesive (SA-MAR), is an optional, single-use adhesive which is ind The Staysite Adhesive (SA-MAR), is an optional, single-use adhesive which is indicated for use with Multi-Site Attachment Rings, models MAR-MI and MAR-SF if more secure attachment is required. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Staysite Adhesive
21 07640121880308 SSET_nG Standard Starter Set (without Service Gas) contains:Ear Clips (EC-MI)Multi-Site Standard Starter Set (without Service Gas) contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04) DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Standard Starter Set (without Service Gas)
22 07640121880803 MARe-SF Single use sensor application ring, recommended for adult, pediatric and neonata Single use sensor application ring, recommended for adult, pediatric and neonatal patients with sensitive/fragile skin LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Multi-Site Attachment Ring for fragile/sensitive skin
23 07640121880728 PSG Cable M The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG). LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable M
24 07640121880667 PSG Cable F The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable F
25 07640121880506 MC-I The Membrane Changer (MC-R) is a reloadable tool to change the membrane of SenTe The Membrane Changer (MC-R) is a reloadable tool to change the membrane of SenTec TC Sensors. Prior reuse, the Membrane Changer (MC-R) must be reloaded with a new Membrane Changer Insert (MC-I). The MC-I is single-use DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Membrane Changer Inserts
26 07640121880445 SSET-N_nG Neonatal Starter Set (without Service Gas) contains:Multi-Site Attachment Rings Neonatal Starter Set (without Service Gas) contains:Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) DQA,DPZ,KLK,LKD,LPP Oximeter,Oximeter, Ear,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter,Oximeter, Ear,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Neonatal Starter Set (without Service Gas)
27 07640121880230 MAR-SF MAR-SF is intended to attach SenTec TC Sensors to various measurement sites for MAR-SF is intended to attach SenTec TC Sensors to various measurement sites for patients with sensitive, fragile but intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Multi-Site Attachment Ring for fragile/sensitive skin
28 07640121880094 SSET Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for m Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) LPP,KLK,DQA,DPZ,LKD Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear,Monitor, Carbon-Dioxide, Cutaneous 2 Standard Starter Set
29 07640121880049 EC-MI The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. S The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. Suitable for patients with earlobes of sufficient size and mature, intact skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Ear Clip
30 07640121880032 AC-150 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Digital Sensor Adapter Cable, 150 cm
31 07640121880889 SDM_WPC This cover will protect the SenTec Digital Monitor (SDM) from dripping water whe This cover will protect the SenTec Digital Monitor (SDM) from dripping water when the device is tilted up to 15° (IPX2). LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 SDM Water Protection Cover
32 07640121880858 GEL-04 The Contact Gel is required for proper CO2 gas conduction from the patient's ski The Contact Gel is required for proper CO2 gas conduction from the patient's skin to the SenTec TC Sensors. Every time a SenTec TC Sensor is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor membrane. LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 Contact Gel 2ml
33 07640121880759 SDM-PO2 Stand alone monitor with colour display for continuous non-invasive vital parame Stand alone monitor with colour display for continuous non-invasive vital parameter monitoring, with integrated docking station for sensor storage and calibration. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 SenTec Digital Monitor (with activated PO2 channel)
34 07640121880735 PSG Cable N The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable N
35 07640121880674 PSG Cable G The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable G
36 07640121880650 PSG Cable E The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable E
37 07640121880629 PSG Cable B The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable B
38 07640121880490 MC-SET The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC-R) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. To enable an economic and cost saving membrane change, the Membrane Changer after use can be reloaded with a new Membrane Changer Insert (MC-I). The memrane changer set contains the MC-R and inserts (MC-I) to reload.Membrane Changer Set [1 membrane changer, 1 insert] DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Membrane Changer Set
39 07640121880162 AC-250 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Digital Sensor Adapter Cable, 250 cm
40 07640121880056 GAS-0812 The Service Gas is required for the calibration of the PCO2-part of SenTec TC Se The Service Gas is required for the calibration of the PCO2-part of SenTec TC Sensors. Depending on usage of the SDMS one Service Gas cylinder lasts for approx. 3 to 4 weeks. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia Service gas
41 07640121880971 PAK-SF A combination of single-use products intended to attach the Sentec Sensors to co A combination of single-use products intended to attach the Sentec Sensors to conventional measurement sites, recommended for adult, pediatric and neonatal patients with sensitive/fragile skin. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Patient Application Kit for sensitive/fragile skin
42 07640121880742 OV-A/P/N Digital Sensor for non-invasive and continuous measurement of transcutaneous car Digital Sensor for non-invasive and continuous measurement of transcutaneous carbon dioxide and oxygen partial pressure as well as pulse oximetry. Suitable for adult, pediatric and neonatal patients. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 OxiVenT™ Sensor
43 07640121880711 PSG Cable L The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG). LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable L
44 07640121880513 VS-A/P/N Digital Sensor for non-invasive and continuous measurement of transcutaneous car Digital Sensor for non-invasive and continuous measurement of transcutaneous carbon dioxide partial pressure and pulse oximetry. Suitable for adult, pediatric and neonatal patients. DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 V-Sign™ Sensor 2
45 07640121880179 AC-750 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). DPZ,DQA,KLK,LKD,LPP Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anes Oximeter, Ear,Oximeter,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia 2 Digital Sensor Adapter Cable, 750 cm
46 07640121880612 PSG Cable A The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) LPP,LKD,KLK,DQA,DPZ Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthe Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia,Monitor, Carbon-Dioxide, Cutaneous,Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia,Oximeter,Oximeter, Ear 2 PSG Cable A
Other products with the same Product Codes "DPZ, DQA, KLK, LKD, LPP"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 B632MDB01006 MO1 MDB01006 Mediblu MEDIBLU MEDICAL LLC
2 B595L2050R0 L2050R Pulse Oximetry Sensor L2050R The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use b The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure, and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.The Vios Chest Sensor and Adapter are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients. Vios Monitoring System Pulse Oximetry Sensor MURATA VIOS PRIVATE LIMITED
3 B595L2050G0 L2050G Adapter L2050G The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use b The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure, and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.The Vios Chest Sensor and Adapter are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients. Vios Montioring System Adapter MURATA VIOS PRIVATE LIMITED
4 B595L2050G0 L2050G Adapter L2050G The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use b The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure, and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.The Vios Chest Sensor and Adapter are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients. Vios Montioring System Adapter MURATA VIOS PRIVATE LIMITED
5 B595CS20500 CS2050 Chest Sensor CS2050 The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use b The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure, and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.The Vios Chest Sensor and Adapter are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients. Vios Monitoring System Chest Sensor MURATA VIOS PRIVATE LIMITED
6 B595CS20500 CS2050 Chest Sensor CS2050 The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use b The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure, and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.The Vios Chest Sensor and Adapter are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients. Vios Monitoring System Chest Sensor MURATA VIOS PRIVATE LIMITED
7 B595BSM20500 BSM2050 Software BSM2050 The Vios Monitoring System (VMS) Bedside Monitor is intended for use by medicall The Vios Monitoring System (VMS) Bedside Monitor is intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure, and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.The VMS Bedside Monitor is intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients. Vios Monitoring System Bedside Monitor MURATA VIOS PRIVATE LIMITED
8 B595BSM20500 BSM2050 Software BSM2050 The Vios Monitoring System (VMS) Bedside Monitor is intended for use by medicall The Vios Monitoring System (VMS) Bedside Monitor is intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure, and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.The VMS Bedside Monitor is intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients. Vios Monitoring System Bedside Monitor MURATA VIOS PRIVATE LIMITED
9 B510VSM300A1 VSM-300A ADVANCED VITAL SIGNS MONITOR ADVANCED INSTRUMENTATIONS, INC.
10 B510VSM3001 VSM-300 ADVANCED VITAL SIGNS MONITOR ADVANCED INSTRUMENTATIONS, INC.
11 B510PM2000XLPRO1 PM-2000XL PRO ADVANCED PATIENT MONITOR ADVANCED INSTRUMENTATIONS, INC.
12 B510PM2000XLPLUS1 PM-2000XL PLUS ADVANCED PATIENT MONITOR ADVANCED INSTRUMENTATIONS, INC.
13 B510PM2000XL1 PM-2000XL ADVANCED PATIENT MONITOR ADVANCED INSTRUMENTATIONS, INC.
14 B510PM2000TM1 PM-2000TM ADVANCED PATIENT MONITOR ADVANCED INSTRUMENTATIONS, INC.
15 B510PM2000M1 PM-2000M ADVANCED PATIENT MONITOR ADVANCED INSTRUMENTATIONS, INC.
16 B510PM2000APRO1 PM-2000A PRO ADVANCED PATIENT MONITOR ADVANCED INSTRUMENTATIONS, INC.
17 B510PM2000A1 PM-2000A ADVANCED PATIENT MONITOR ADVANCED INSTRUMENTATIONS, INC.
18 B5100602 B510-0602 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
19 B5051300 B505-1300 B500 SERIES PULSE OXIMETER B500 SERIES BETA BIOMED SERVICES INC
20 B5051033B01 B505-1033B B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
21 B5051017 B505-1017 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
22 B505101410 B505-1014-10 B500 PULSE OXIMETER SENSOR B500 Series BETA BIOMED SERVICES INC
23 B5051014 B505-1014 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
24 B5051011N01 B505-1011N B500 SERIES PULSE OXIMETER B500 SERIES BETA BIOMED SERVICES INC
25 B5051011M10 B505-1011M-10 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
26 B5051011M01 B505-1011M B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
27 B5051011 B505-1011 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
28 B5051007 B505-1007 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
29 B5051005 B505-1005 B500 Series Pulse Oximeter Sensor B500 Series BETA BIOMED SERVICES INC
30 B5051002N10 B505-1002N-10 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
31 B5051002N1 B505-1002N B505-1002N B500 PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
32 B5051002 B505-1002 B500 SPO2 PULSE OXIMETER SENSOR B500 Series BETA BIOMED SERVICES INC
33 B5051001 B505-1001 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
34 B425CST070312092 CST070-31209 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
35 B425CST07031202 CST070-3120 pulse Oximeter, with an optional adapter cable for compatible models.SpO2 sensor pulse Oximeter, with an optional adapter cable for compatible models.SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
36 B425CST070310792 CST070-31079 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
37 B425CST07031072 CST070-3107 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
38 B425CST070310692 CST070-31069 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
39 B425CST07031062 CST070-3106 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
40 B425CST070310492 CST070-31049 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
41 B425CST07031042 CST070-3104 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
42 B425CST064316292 CST064-31629 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Ear MEDIAID INC
43 B5011011M01 B501-1011M B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
44 B5011005 B501-1005 B500 SERIES PULSE OXIMETER SENSOR B500 SERIES BETA BIOMED SERVICES INC
45 B425CST07031622 CST070-3162 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
46 B425CST070313092 CST070-31309 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
47 B425CST07031302 CST070-3130 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
48 B425CST070312692 CST070-31269 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
49 B425CST07031262 CST070-3126 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC
50 B425CST070312592 CST070-31259 SpO2 sensors are electro-optical sensors that function without skin penetration, SpO2 sensors are electro-optical sensors that function without skin penetration, electrical contact, or heat transfer. The sensor uses optical means to determine the light absorption of functional arterial hemoglobin by being connected between the patient and the Oximeter. The sensor contains three optical components, (LED) that serves as light sources and one photodiode that acts as light detector. The optical components are housed in adhesive film/rigid spring-loaded clip, or foam and Velcro wrap. The sensor cable is terminated by a connector as specified by the different make/ manufacturer of the pulse Oximeter, with an optional adapter cable for compatible models. Reusable Sensor - Y MEDIAID INC