Other products from "STRYKER CORPORATION"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07613327392852 6371 6373-000-000 FPO STRETCHER, WHEELED 2 NA
2 00860002177779 910-01947 910-01947 MSX System, network and communication, physiological monitors 2 Engage Medical Device Alert Notification System (EMDAN)
3 00816728021650 Narrow / Flat 104008 Illuminator, Narrow/Flat FSZ Light, Surgical, Carrier 2 PhotonGuide
4 00816728021490 175mm Retractor A175SE LT Adapt Smoke Evacuation Retractor, 175mm GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
5 00816728021476 A155WSE A155WSE LT Adapt Smoke Evacuation Retractor, 155mm, Wide GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
6 00816728021452 155mm Retractor A155SE LT Adapt Smoke Evacuation Retractor, 155mm GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
7 00816728021445 A135WTSE A135WTSE LT Adapt Smoke Evacuation Retractor, 135mm, Wide, Teeth GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
8 00816728021438 A135WSE A135WSE LT Adapt Smoke Evacuation Retractor, 135mm, Wide GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
9 00816728021414 135mm Retractor A135SE LT Adapt Smoke Evacuation Retractor, 135mm GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
10 00816728021391 A90WSE A90WSE LT Adapt Smoke Evacuation Retractor, 90mm, Wide GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
11 00816728021377 90mm Retractor A90SE LT Adapt Smoke Evacuation Retractor, 90mm GAD Retractor 1 Eikon LT Adapt Smoke Evacuation
12 00816728020974 11109 11109 Glenoid Retractor GAD RETRACTOR 1 N/A
13 00816728020967 E1SL E1SL Retractor, Standard, Long GAD RETRACTOR 1 Eiberg
14 00816728020950 E1S E1S Retractor, Standard GAD RETRACTOR 1 Eiberg
15 00816728020646 Wide / Flat 104015 Illuminator, Wide/Flat FSZ Light, Surgical, Carrier 2 PhotonGuide
16 00816728020554 A38D A38D Deaver 38mm Wide Retractor GAD RETRACTOR 1 N/A
17 00816728020547 A25D A25D Deaver 25mm Wide Retractor GAD RETRACTOR 1 N/A
18 00816728020226 FC1B FC1B Bifurcated Fiber Optic Cable 11.5ft FST Light, Surgical, Fiberoptic 2 N/A
19 00816728020202 FC1SP FC1SP Single Fiber Optic Cable 10ft, Pink FST Light, Surgical, Fiberoptic 2 N/A
20 00816728020196 FC1S FC1S Single Fiber Optic Cable 10ft FST Light, Surgical, Fiberoptic 2 N/A
21 37613252633144 CAT02009 CAT02009 FLEXSTICK PASSER WIRE NBH ACCESSORIES,ARTHROSCOPIC NA
22 34546540756979 234-500-227 234-500-227 .027" CROSS-SCREW FLEXIBLE CANNULA WITH SLEEVES NBH ACCESSORIES,ARTHROSCOPIC NA
23 34546540756504 234-030-027 234-030-027 1.0MM X 14IN NITINOL GUIDE WIRE NBH ACCESSORIES,ARTHROSCOPIC NA
24 34546540756412 234-030-018 234-030-018 1.5MM X 14IN NITINOL GUIDE WIRE NBH ACCESSORIES,ARTHROSCOPIC NA
25 30816728021569 S175 S175 LT Adapt Smoke Evacuation Retractor, 175mm, Reusable Slat GAD Retractor Eikon LT Adapt Smoke Evacuation
26 30816728021552 S155 S155 LT Adapt Smoke Evacuation Retractor, 155mm, Reusable Slat GAD Retractor Eikon LT Adapt Smoke Evacuation
27 30816728021545 S135 S135 LT Adapt Smoke Evacuation Retractor, 135mm, Reusable Slat GAD Retractor Eikon LT Adapt Smoke Evacuation
28 30816728021538 S90 S90 LT Adapt Smoke Evacuation Retractor, 90mm, Reusable Slat GAD Retractor Eikon LT Adapt Smoke Evacuation
29 07613327541519 6083 6083-032-000 IV Pole FPO STRETCHER, WHEELED 2 Havasu
30 07613327582048 5220030275 5220-030-275 7.5mm Acorn TPS M HBE DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) 2 N/A
31 07613327582031 5220030260 5220-030-260 6mm Acorn TPS M HBE DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) 2 N/A
32 07613327582024 5220030290 5220-030-290 9mm Acorn TPS M HBE DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) 2 N/A
33 07613327572117 650705550003 650705550003 FPO STRETCHER, WHEELED 2 Power-PRO 2, High Configuration - No WIFI
34 07613327568998 0794111090 0794-111-090 QBL Software License JQP Calculator/data processing module, for clinical use 1 N/A
35 07613327563245 3910955221 3910-955-221 ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 1.4MM AND 1.8MM (NON-SLID ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 1.4MM AND 1.8MM (NON-SLIDING) XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
36 07613327563238 3910965032 3910-965-032 ALPHAVENT SUTURE ANCHOR 6.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS #2 XBRAID S SUTURE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
37 07613327563221 3910965221 3910-965-221 ALPHAVENT SUTURE ANCHOR 6.5MM PEEK, SUTURE ANCHOR WITH 1.4MM AND 1.8MM (NON-SLID ALPHAVENT SUTURE ANCHOR 6.5MM PEEK, SUTURE ANCHOR WITH 1.4MM AND 1.8MM (NON-SLIDING) XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
38 07613327563214 3910955032 3910-955-032 ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS #2 XBRAID S SUTURE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
39 07613327563207 3910965222 3910-965-222 ALPHAVENT SUTURE ANCHOR 6.5MM PEEK, SUTURE ANCHOR WITH #2 XBRAID S SUTURE AND 1. ALPHAVENT SUTURE ANCHOR 6.5MM PEEK, SUTURE ANCHOR WITH #2 XBRAID S SUTURE AND 1.8MM (NON-SLIDING) XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
40 07613327563191 3910955132 3910-955-132 ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS #2 XBRAID S SUT ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS #2 XBRAID S SUTURE WITH MO-6 TAPERED NEEDLES MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
41 07613327563184 3910955222 3910-955-222 ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH #2 XBRAID S SUTURE AND 1. ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH #2 XBRAID S SUTURE AND 1.8MM (NON-SLIDING) XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
42 07613327563177 3910955022 3910-955-022 ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 2 STRANDS #2 XBRAID S SUTURE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
43 07613327563160 3910965031 3910-965-031 ALPHAVENT SUTURE ANCHOR 6.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID TT ALPHAVENT SUTURE ANCHOR 6.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
44 07613327537246 6080 6080-216-020 IV Pole FPO STRETCHER, WHEELED 2 Havasu
45 07613327563153 3910955031 3910-955-031 ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID TT ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
46 07613327563146 3910955021 3910-955-021 ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 2 STRANDS 1.4MM XBRAID TT ALPHAVENT SUTURE ANCHOR 5.5MM PEEK, SUTURE ANCHOR WITH 2 STRANDS 1.4MM XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
47 07613327563115 3910947131 3910-947-131 ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID T ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID TT SUTURE TAPE WITH MO-6 TAPERED NEEDLES MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
48 07613327563108 3910947031 3910-947-031 ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID T ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH 3 STRANDS 1.4MM XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
49 07613327563092 3910947222 3910-947-222 ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH #2 XBRAID S SUTURE AND 1 ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH #2 XBRAID S SUTURE AND 1.8MM (NON-SLIDING) XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
50 07613327563085 3910947221 3910-947-221 ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH 1.4MM AND 1.8MM (NON-SLI ALPHAVENT SUTURE ANCHOR 4.75MM PEEK, SUTURE ANCHOR WITH 1.4MM AND 1.8MM (NON-SLIDING) XBRAID TT SUTURE TAPE MBI Fastener, fixation, nondegradable, soft tissue 2 AlphaVent
Other products with the same Product Code "OCZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 M84972020 7202 7202 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
2 M84948500 4850 4850 A control handle for a flexible manual device used in combination with a compati A control handle for a flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. The device is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket Handle HOBBS MEDICAL, INC.
3 M84948320 4832 4832 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
4 M84948300 4830 4830 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
5 M84948240 4824 4824 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
6 M84948220 4822 4822 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
7 M84948160 4816 4816 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
8 M84948140 4814 4814 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
9 M84948080 4808 4808 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
10 M84948060 4806 4806 A flexible manual device used in combination with a compatible endoscope to gras A flexible manual device used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with a helical shaped basket which is operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reusable device. Hobbs Helical Retrieval Basket HOBBS MEDICAL, INC.
11 M8494577OLY0 4577OLY 4577OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
12 M84945770 4577 4577 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
13 M8494575OLY0 4575OLY 4575OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
14 M84945750 4575 4575 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
15 M8494573OLY0 4573OLY 4573OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
16 M84945730 4573 4573 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
17 M8494572OLY0 4572OLY 4572OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
18 M84945720 4572 4572 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
19 M8494571OLY0 4571OLY 4571OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
20 M84945710 4571 4571 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
21 M8494570OLY0 4570OLY 4570OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
22 M84945700 4570 4570 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
23 M8494567OLY0 4567OLY 4567OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
24 M84945670 4567 4567 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
25 M8494565OLY0 4565OLY 4565OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
26 M84945650 4565 4565 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
27 M8494564OLY0 4564OLY 4564OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
28 M84945640 4564 4564 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
29 M8494563OLY0 4563OLY 4563OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
30 M84945630 4563 4563 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
31 M8494562OLY0 4562OLY 4562OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
32 M84945620 4562 4562 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
33 M8494561OLY0 4561OLY 4561OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
34 M84945610 4561 4561 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
35 M8494560OLY0 4560OLY 4560OLY A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
36 M84945600 4560 4560 A flexible device intended to be inserted through an endoscope to ligate, cauter A flexible device intended to be inserted through an endoscope to ligate, cauterize, and cut polyps, or other mucosal lesions in the gastrointestinal (GI) tract, using high frequency current during endotherapy. It consists of a flexible insulated insertion sheath, a snare loop attached to the distal end of the sheath, and an operating wire connected to both the loop and a handle which controls the operating wire. The proximal end of the operating wire is connected to a high frequency power supply unit. This is a single use device. Hobbs Medical Polypectomy Snare HOBBS MEDICAL, INC.
37 16948318968807 M00527550 Rescue Single Use Grasping Forceps Rescue ANREI MEDICAL(HZ) CO.,LTD.
38 16948318903983 M00538350 Rescue Single Use Grasping Forceps Rescue ANREI MEDICAL(HZ) CO.,LTD.
39 16948318903938 M00527750 Rescue Single Use Grasping Forceps Rescue ANREI MEDICAL(HZ) CO.,LTD.
40 16948318903907 M00527650 Rescue Single Use Grasping Forceps Rescue ANREI MEDICAL(HZ) CO.,LTD.
41 16948318903822 M00527450 Rescue Single Use Grasping Forceps Rescue ANREI MEDICAL(HZ) CO.,LTD.
42 M707ES26235 ES26235 ES26235 The Slater Endoscopy Ensizor flexible endoscopic scissors is a single-use flexib The Slater Endoscopy Ensizor flexible endoscopic scissors is a single-use flexible device used in combination with a dedicated 2.8 mm, minimum channel size endoscope, and is intended to cut tissue or sutures during an endoscopic procedure. It is constructed of a flexible metal coil whose distal end is equipped with a pair of cutting blades operated through a control handle at the proximal end. It is introduced into the body cavity through the working endoscope through the working channel of the endoscope The cutting blades are 2.6 mm in diameter with an insertion length of 235 cm. ENSIZOR SLATER ENDOSCOPY LLC
43 M707ES26165 ES26165 ES26165 The Slater Endoscopy Ensizor flexible endoscopic scissors is a single-use flexib The Slater Endoscopy Ensizor flexible endoscopic scissors is a single-use flexible device used in combination with a dedicated 2.8 mm, minimum channel size endoscope, and is intended to cut tissue or sutures during an endoscopic procedure. It is constructed of a flexible metal coil whose distal end is equipped with a pair of cutting blades operated through a control handle at the proximal end. It is introduced into the body cavity through the working endoscope through the working channel of the endoscope The cutting blades are 2.6 mm in diameter with an insertion length of 165 cm. ENSIZOR SLATER ENDOSCOPY LLC
44 10680651927696 92769 60728 HALYARD* Foreign Body Retrieval Basket Halyard AVANOS MEDICAL, INC.
45 10680651927689 92768 60727 HALYARD* Foreign Body Retrieval Basket Halyard AVANOS MEDICAL, INC.
46 10680651927672 92767 60719 HALYARD* Foreign Body Retrieval Basket Halyard AVANOS MEDICAL, INC.
47 10680651927665 92766 60718 HALYARD* Foreign Body Retrieval Basket Halyard AVANOS MEDICAL, INC.
48 10680651927658 92765 60717 HALYARD* Foreign Body Retrieval Basket Halyard AVANOS MEDICAL, INC.
49 10680651927641 92764 60634 HALYARD* Foreign Body Grasping Forceps Halyard AVANOS MEDICAL, INC.
50 10680651927634 92763 60631 HALYARD* Foreign Body Grasping Forceps Halyard AVANOS MEDICAL, INC.