CAREvent DRA hand held automatic resuscitator is pneumatically powered, time/vol
CAREvent DRA hand held automatic resuscitator is pneumatically powered, time/volume cycled ventilatlatory resuscitator. It provides trained individuals with a safe and effective means of providing artificial ventilation during respiratory and cardiac arrest. The CAREvent DRA delivers automatic ventilation with controlled flow rate, airway pressure, tidal volume and frequency. Patients are protected from over inflation and potential barotraumas by an audible Pressure Relief System. In addition, CAREvent DRA allows the breathing patient to “Demand Breathe” on 100% oxygen at their own rate and volume. The 01CV3400 is a kit which consists of a CAREvent DRA resuscitator, a pressure regulator, a universal resuscitation facemask, an oxygen mask with oxygen tubing, a oxygen supply hose and a carrying case.
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator, a pres
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator, a pressure regulator and an aspirator in carrying case.O-Two Demand Valve Resuscitator comes standard with pressure relief system and audible alarm as well a manual ventilation button conveniently located on the front of the resuscitator. The manual ventilation flow rate is fixed at 40 L/min. During spontaneous respirations, the Demand valve resuscitator is designed to provide 100% oxygen to the patient with minimal inspiratory effort. The oxygen demand flow is controlled by the patient’s inspiratory effort with aminimum peak flow rate of 140 L/min to accommodate the patient’s own respiratory distress situation.
The SMART BAG MO Manual Resuscitator is Bag Valve Mask Resuscitator comprising a
The SMART BAG MO Manual Resuscitator is Bag Valve Mask Resuscitator comprising a self inflating bag, a one way valve and a face mask designed to supply accurate controlled ventilation to a non-breathing patient by the compression of the bag portion of the device by the operator. Similar in all respects to the conventional BVMs, the SMART BAG MO offers accurate controlled ventilation that significantly reduces the risk of gastric insufflation. The patient’s airway pressure is maintained at an optimally low level due to the SMART® technology in the bag that responds to both the rescuer’s squeeze of the bag and the patient’s own respiratory condition. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing Child patient.
The disposable Child EASY GRIP® Bag Valve Mask Resuscitator is a reusable device
The disposable Child EASY GRIP® Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing CHILD patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.The Child EASY GRIP resuscitator comes standard with a Pressure Relief Valve set at 40 cm H2O which can be overridden by the operator.
The Adult EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for ma
The Adult EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing ADULT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.
Fingertip Pulse Oximeter is a portable non-invasive, spot-check, oxygen saturati
Fingertip Pulse Oximeter is a portable non-invasive, spot-check, oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult and pediatric patient at home, and hospital (including clinical use and in internist/surgery, Anesthesia, intensive care and etc.). Not for continuously monitoring.
CAREvent ALS+ is intended to provide artificial ventilation for patients during
CAREvent ALS+ is intended to provide artificial ventilation for patients during respiratory and cardiac arrest. The single control for the simultaneous adjustment of ventilation frequency and tidal volume has 12 settings for a range of patients from 20 kg body weight to large adults. A separate Manual/Automatic control allows the operator to turn off the automatic cycling and ventilate the patient manually. Patients are protected from over inflation and potential barotraumas by an audible Pressure Relief System. CAREvent ALS+ also includes an airway Pressure Gauge and pneumatic alarm for Low Pressure Input Pressure. It also allows the breathing patient to “Demand Breathe” on 100% oxygen at their own rate and volume.
The Rescue Breather consists of a one-way valve that has a large block is placed
The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider. Each Rescue Breather is packed with a pair of gloves in a Red nylon keychain/belt pouch.
CAREvent MRI is pneumatically powered, time/volume cycled, intermittent positive
CAREvent MRI is pneumatically powered, time/volume cycled, intermittent positive pressure patient ventilators specifically designed for use by trained personnel in the pre-hospital, hospital, interhospital and air ambulance environments. It has independent controls for minute volume and frequency that provide a comprehensive range of 12 ventilation frequencies and 12 minute-volume settings. This provides a possible 144 combinations of delivered tidal volume and respiratory rate. The various modes of operation of the ventilators support the resuscitation and transportation of a wide range of patients (from infants to adults).The CAREvent MRI contains no ferrous metals and is suitable for use in a three-Tesla MRI environment.
CAREvent PAR assists the rescuer in providing efficient and effective CPR by pro
CAREvent PAR assists the rescuer in providing efficient and effective CPR by providing with audible and visual prompts for chest compression, ventilation timing and automatic ventilation. The visual prompts aid the rescuer in their CPR efforts by providing illuminated pictograms of the CPR process, timed with the audible voice prompts. These voice and visual prompts help to significantly reduce interruptions in chest compression. The audible and visual warnings of mask leakage or airway obstruction assist the rescuer in ensuring that adequate tidal volumes are delivered.
CAREvent DRA hand held automatic resuscitator is pneumatically powered, time/vol
CAREvent DRA hand held automatic resuscitator is pneumatically powered, time/volume cycled ventilatlatory resuscitator. It provides trained individuals with a safe and effective means of providing artificial ventilation during respiratory and cardiac arrest. The CAREvent DRA delivers automatic ventilation with controlled flow rate, airway pressure, tidal volume and frequency. Patients are protected from over inflation and potential barotraumas by an audible Pressure Relief System. In addition, CAREvent DRA allows the breathing patient to “Demand Breathe” on 100% oxygen at their own rate and volume.
This Bag Valve Mask Resuscitator kit contains an Adult EASY GRIP® PVC Bag Valve
This Bag Valve Mask Resuscitator kit contains an Adult EASY GRIP® PVC Bag Valve Mask Resuscitator, three different sizes Guedel Airways and two different sizes Face masks for adult patients. The Adult EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing ADULT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag. The Resuscitator comes with a Pressure Relief Valve set at 70 cm H2O, which can be overridden by the operator if desired.
The Adult EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for ma
The Adult EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing ADULT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.The Resuscitator comes with a Pressure Relief Valve set at 70 cm H2O, which can be overridden by the operator if desired.
The infant EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for m
The infant EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing INFANT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.The Infant EASY GRIP resuscitator comes standard with a Pressure Relief Valve set at 40 cm H2O which can be overridden by the operator.
The Child EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for ma
The Child EASY GRIP® PVC Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing CHILD patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.The Child EASY GRIP resuscitator comes standard with a Pressure Relief Valve set at 40 cm H2O which can be overridden by the operator.
The infant EASY GRIP® Silicone Bag Valve Mask Resuscitator is a reusable device
The infant EASY GRIP® Silicone Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing INFANT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.The Infant EASY GRIP resuscitator comes standard with a Pressure Relief Valve set at 40 cm H2O which can be overridden by the operator.
The Child EASY GRIP® Silicone Bag Valve Mask Resuscitator is a reusable device f
The Child EASY GRIP® Silicone Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing CHILD patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.The Child EASY GRIP resuscitator comes standard with a Pressure Relief Valve set at 40 cm H2O which can be overridden by the operator.
The Adult EASY GRIP® Silicone Bag Valve Mask Resuscitator is a reusable device f
The Adult EASY GRIP® Silicone Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing ADULT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.
The disposable Adult EASY GRIP® Bag Valve Mask Resuscitator is a reusable device
The disposable Adult EASY GRIP® Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing ADULT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.
The disposable Adult EASY GRIP® Bag Valve Mask Resuscitator is a reusable device
The disposable Adult EASY GRIP® Bag Valve Mask Resuscitator is a reusable device for manual ventilation. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing ADULT patient. When used with a supplemental oxygen supply, the device may provide 100% oxygen on every squeeze of the bag.
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
O-Two Disposable Pressure Manometer is intended for use where monitoring airway
O-Two Disposable Pressure Manometer is intended for use where monitoring airway pressure is desired. This device provides a visual indication of air way pressure to be used on O_Two Single-use "open Circuit" CPAP System.
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting
BYE
Attachment, Breathing, Positive End Expiratory Pressure
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressur
The O-Two single-use open CPAP delivery system provides 5-20 cmH2O CPAP pressure to patients. The adjustment of the CPAP level is achieved by adjusting the output flow from oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting:
BYE
Attachment, Breathing, Positive End Expiratory Pressure
O-Two Demand Valve Resuscitator comes standard with pressure relief system and a
O-Two Demand Valve Resuscitator comes standard with pressure relief system and audible alarm as well a manual ventilation button conveniently located on the front of the resuscitator. The manual ventilation flow rate is fixed at 40 L/min. During spontaneous respirations, the Demand valve resuscitator is designed to provide 100% oxygen to the patient with minimal inspiratory effort. The oxygen demand flow is controlled by the patient’s inspiratory effort with aminimum peak flow rate of 140 L/min to accommodate the patient’s own respiratory distress situation.
The O-Two Statvac® II Aspirator is capable of effectively suctioning out excessi
The O-Two Statvac® II Aspirator is capable of effectively suctioning out excessive quantities of fluid/particles from a patient’s oro/naso pharynx. The lightweight aspirator is designed to be attached to any 50 psi DISS outlet. The ON/OFF shuttle provides for fast actuation of the aspirator in an emergency. Continuous suction is provided by simply depressing the “GREEN” shuttle control. The aspiration can be quickly and easily turned off by depressing the “RED” shuttle control button on the opposite side of the aspirator.
The O-Two Statvac® II Aspirator is capable of effectively suctioning out excessi
The O-Two Statvac® II Aspirator is capable of effectively suctioning out excessive quantities of fluid/particles from a patient’s oro/naso pharynx. The lightweight aspirator is designed to be attached to any 50 psi DISS outlet. The ON/OFF shuttle provides for fast actuation of the aspirator in an emergency. Continuous suction is provided by simply depressing the “GREEN” shuttle control. The aspiration can be quickly and easily turned off by depressing the “RED” shuttle control button on the opposite side of the aspirator.
o_two e700 is electronically controlled, pneumatically powered ventilators with
o_two e700 is electronically controlled, pneumatically powered ventilators with a AC/DC power adapter and an internal rechargeable Lithium Ion battery pack used to power the electronics, intended for use during transport to provide resuscitation and/or ventilatory support to wide range of patients in respiratory distress or arrest.It is a time-cycled, volume-constant and pressure-controlled emergency and transport ventilator designed for use in the pre-hospital, intra-hospital, inter-hospital and transport settings. It is intended for use with adult, child and infant patients with a tidal volume from 50 ml upwards who are in respiratory and/or cardiac arrest or respiratory distress who require ventilatory support.
CAREvent ALS kit 01CV3212 contains a CAREvent ALS resuscitator, a pressure regul
CAREvent ALS kit 01CV3212 contains a CAREvent ALS resuscitator, a pressure regulator, and an aspirator in moulded case with a Yankauer Scution Tip with Tubing.CAREvent ALS hand held automatic resuscitator is pneumatically powered, time/volume cycled ventilatlatory resuscitator. It provides trained individuals with a safe and effective means of providing artificial ventilation during respiratory and cardiac arrest. The CAREvent ALS delivers automatic ventilation with controlled flow rates, airway pressure, tidal volume and frequencies. Patients are protected from over inflation and potential barotraumas by an audible Pressure Relief System. In addition, CAREvent ALS allows the breathing patient to “Demand Breathe” on 100% oxygen at their own rate and volume.
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator, a pres
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator, a pressure regulator and an aspirator in moulded case.O-Two Demand Valve Resuscitator comes standard with pressure relief system and audible alarm as well a manual ventilation button conveniently located on the front of the resuscitator. The manual ventilation flow rate is fixed at 40 L/min. During spontaneous respirations, the Demand valve resuscitator is designed to provide 100% oxygen to the patient with minimal inspiratory effort. The oxygen demand flow is controlled by the patient’s inspiratory effort with aminimum peak flow rate of 140 L/min to accommodate the patient’s own respiratory distress situation.
The SMART BAG MO Manual Resuscitator is Bag Valve Mask Resuscitator comprising a
The SMART BAG MO Manual Resuscitator is Bag Valve Mask Resuscitator comprising a self inflating bag, a one way valve and a face mask designed to supply accurate controlled ventilation to a non-breathing patient by the compression of the bag portion of the device by the operator. Similar in all respects to the conventional BVMs, the SMART BAG MO offers accurate controlled ventilation that significantly reduces the risk of gastric insufflation. The patient’s airway pressure is maintained at an optimally low level due to the SMART® technology in the bag that responds to both the rescuer’s squeeze of the bag and the patient’s own respiratory condition. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing Adult patient. For SMART BAG MO, the flow limiting valve can be disabled to permit conventional operation of the resuscitator.
The SMART BAG MO Manual Resuscitator is Bag Valve Mask Resuscitator comprising a
The SMART BAG MO Manual Resuscitator is Bag Valve Mask Resuscitator comprising a self inflating bag, a one way valve and a face mask designed to supply accurate controlled ventilation to a non-breathing patient by the compression of the bag portion of the device by the operator. Similar in all respects to the conventional BVMs, the SMART BAG MO offers accurate controlled ventilation that significantly reduces the risk of gastric insufflation. The patient’s airway pressure is maintained at an optimally low level due to the SMART® technology in the bag that responds to both the rescuer’s squeeze of the bag and the patient’s own respiratory condition. It is designed for use in various clinical settings to provide respiratory support to the respiratory distressed or non-breathing Child patient. For SMART BAG MO, the flow limiting valve can be disabled to permit conventional operation of the resuscitator. The Child resuscitator comes standard with a Pressure Relief Valve set at 40 cm H2O which can be overridden by the operator.
Rescue Breather® CPR Pocket Ventilator provides the rescuer with a safe and effe
Rescue Breather® CPR Pocket Ventilator provides the rescuer with a safe and effective means to perform life saving expired air resuscitation while offering maximum protection from the potential risks of disease transfer for both the patient and the rescuer.The Rescue Breather® CPR Pocket Ventilator comes standard with a disposable Low-Resistance Clear One-Way-Valve with built-in 3M Filtrete® Filter, protected Oxygen inlet, adjustable Head Strap, pair of “Latex Free” Nitrile Gloves, Instructions leaflet and Clam Shell Carrying Case.
Rescue Breather® CPR Pocket Ventilator provides the rescuer with a safe and effe
Rescue Breather® CPR Pocket Ventilator provides the rescuer with a safe and effective means to perform life saving expired air resuscitation while offering maximum protection from the potential risks of disease transfer for both the patient and the rescuer.The Rescue Breather® CPR Pocket Ventilator comes standard with a disposable Low-Resistance Clear One-Way-Valve with built-in 3M Filtrete® Filter, protected Oxygen inlet, adjustable Head Strap, pair of “Latex Free” Nitrile Gloves, Instructions leaflet and Clam Shell Carrying Case.
CPR Bio-Barrier Training Faceshield is intended to provide CPR trained individua
CPR Bio-Barrier Training Faceshield is intended to provide CPR trained individuals with personal protection from disease transmission during Expired Air Resuscitation (mouth to mouth) and during CPR training on manikins.The use if this device does not guarantee complete protection from disease transmission.
The Rescue Breather consists of a one-way valve that has a large block is placed
The Rescue Breather consists of a one-way valve that has a large block is placed in a patient's mouth, The person providing CPR then blows through the valve to inflate patient's lung. The intended purpose of the valve and the filter is to prevent any cross contamination and potential cross infection by preventing contact with body fluids such as vomit, blood or saliva between patient and first aid provider.
o_two e600 is electronically controlled, pneumatically powered ventilators with
o_two e600 is electronically controlled, pneumatically powered ventilators with a AC/DC power adapter and an internal rechargeable Lithium Ion battery pack used to power the electronics, intended for use during transport to provide resuscitation and/or ventilatory support to wide range of patients in respiratory distress or arrest.It is a time-cycled, volume-constant emergency and transport ventilator designed for use in the pre-hospital, intra-hospital, inter-hospital and transport settings. It is intended for use with adult, child and infant patients with a tidal volume from 50 ml upwards who are in respiratory and/or cardiac arrest or respiratory distress who require ventilatory support.
The Oxygen Demand Valve provides 100% oxygen to patients suffering from respirat
The Oxygen Demand Valve provides 100% oxygen to patients suffering from respiratory distress at the flow rate demanded by the patient.
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator and a p
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator and a pressure regulator in carrying case.O-Two Demand Valve Resuscitator comes standard with pressure relief system and audible alarm as well a manual ventilation button conveniently located on the front of the resuscitator. The manual ventilation flow rate is fixed at 40 L/min. During spontaneous respirations, the Demand valve resuscitator is designed to provide 100% oxygen to the patient with minimal inspiratory effort. The oxygen demand flow is controlled by the patient’s inspiratory effort with aminimum peak flow rate of 140 L/min to accommodate the patient’s own respiratory distress situation.
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator and a p
O-Two Demand Valve Resuscitator Kit contains a Demand Valve resuscitator and a pressure regulator.O-Two Demand Valve Resuscitator comes standard with pressure relief system and audible alarm as well a manual ventilation button conveniently located on the front of the resuscitator. The manual ventilation flow rate is fixed at 40 L/min. During spontaneous respirations, the Demand valve resuscitator is designed to provide 100% oxygen to the patient with minimal inspiratory effort. The oxygen demand flow is controlled by the patient’s inspiratory effort with aminimum peak flow rate of 140 L/min to accommodate the patient’s own respiratory distress situation.
Adult / pediatric CPAP patient circuit, disposable, single patient use 6 feet lo
Adult / pediatric CPAP patient circuit, disposable, single patient use 6 feet long, with large mask, head strap and expiratory filter each
Adult / pediatric CPAP patient circuit, disposable, single patient use 6 feet lo
Adult / pediatric CPAP patient circuit, disposable, single patient use 6 feet long with large mask and head strap each.
Curaplex CPAP Starter Kit incl CPAP Unit, Bag w/Strap, SM Mask, LG Mask, Breathi
Curaplex CPAP Starter Kit incl CPAP Unit, Bag w/Strap, SM Mask, LG Mask, Breathing Circuit w/MED Mask
It is a demand valve with an adult mask and hose. A non-sterile device that is u
It is a demand valve with an adult mask and hose. A non-sterile device that is used to regulate the therapeutic gas flow to a patient in response to the patient's breathing effort. It is used, e.g., in ventilator breathing circuits, resuscitation devices and in on demand analgesia devices. This is a reusable device.
It is a demand valve with a hose without a mask. A non-sterile device that is us
It is a demand valve with a hose without a mask. A non-sterile device that is used to regulate the therapeutic gas flow to a patient in response to the patient's breathing effort. It is used, e.g., in ventilator breathing circuits, resuscitation devices and in on demand analgesia devices. This is a reusable device.