Other products from "EURO-DIAGNOSTICA AB"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07340058410479 FAJO200 FAJO200 DHN Antinuclear Antibody, Indirect Immunofluorescent, Antigen, Control 2 DIASTAT anti-Jo-1
2 07340058410417 FMIT200 FMIT200 DBM Antimitochondrial Antibody, Indirect Immunofluorescent, Antigen, Control 2 DIASTAT anti-Mitochondrial
3 07340058410110 FATG200 FATG200 JZO System, Test, Thyroid Autoantibody 2 DIASTAT anti-thyroglobulin
4 07340058410721 GP104X GP104X DBL Multiple Autoantibodies, Indirect Immunofluorescent, Antigen, Control 2 WIESLAB anti-GBM semi quantitative kit
5 07340058410707 GCP100 GCP100 MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 WIESLAB antiGBM, ANCA Screen kit
6 07340058410936 CapPR3 US CapPR3 US MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 WIESLAB Capture PR3 ANCA
7 07340058410615 FCCP100 FCCP100 NHX Antibodies, Anti-Cyclic Citrullinated Peptide (Ccp) 2 EDIA anti-CCP
8 07340058410509 FAID200 FAID200 LJM Antinuclear Antibody (Enzyme-Labeled), Antigen, Controls 2 DIASTAT ENA Profile
9 07340058410486 FANA200 FANA200 LKJ Antinuclear Antibody, Antigen, Control 2 DIASTAT ANA
10 07340058410233 FCAR100M FCAR100M MID System, Test, Anticardiolipin Immunological 2 DIASTAT anti-Cardiolipin IgM
11 07340058410059 FASM200 FASM200 LKP Anti-Sm Antibody, Antigen And Control 2 DIASTST anti-Sm
12 07340058410035 FDNA100 FDNA100 KTL Anti-Dna Indirect Immunofluorescent Solid Phase 2 DIASTAT anti-dsDNA
13 07340058410028 FRNP200 FRNP200 LKP Anti-Sm Antibody, Antigen And Control 2 DIASTAT anti-Sm/RNP
14 07340058410011 FALA200 FALA200 LKO Anti-Rnp Antibody, Antigen And Control 2 DIASTAT anti-La (SS-B)
15 07340058410431 CCPoint20US CCPoint20US NHX Antibodies, Anti-Cyclic Citrullinated Peptide (Ccp) 2 CCPoint
16 07340058410493 FSWS200 FSWS200 LLL Extractable Antinuclear Antibody, Antigen And Control 2 DIASTAT ENA Single Well Screen
17 07340058410400 FCAR100T FCAR100T MID System, Test, Anticardiolipin Immunological 2 DIASTAT total anti-Cardiolipin
18 07340058410196 FCAR100G FCAR100G MID System, Test, Anticardiolipin Immunological 2 DIASTAT anti-Cardiolipin IgG
19 07340058410158 FBGP100 FBGP100 MSV System,Test,Antibodies,B2 - Glycoprotein I (B2 - Gpi) 2 DIASTAT anti-B2-Glycoprotein-1 IgM
20 07340058410004 FARO300 FARO300 LKO Anti-Rnp Antibody, Antigen And Control 2 DIASTAT anti-Ro (SS-A)
21 07340058410943 CapMPO US CapMPO US MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 WIESLAB Capture MPO-ANCA
22 07340058410639 CP111 CP111 MOB Test System, Antineutrophil Cytoplasmic Antibodies (Anca) 2 WIESLAB ANCA Screen kit
23 07340058410134 FTPO300 FTPO300 JZO System, Test, Thyroid Autoantibody 2 DIASTAT anti-Thyroid Peroxidase
24 07340058412077 RB310 RB310 JME Radioimmunoassay, Glucagon 1 EURIA Glucagon
25 07340058410462 FSCL200 FSCL200 LKJ Antinuclear Antibody, Antigen, Control 2 DIASTAT anti-SCL-70
26 07340058412015 MD302 MD302 CGC Radioimmunoassay, Gastrin 1 EURIA Gastrin
27 07340058410868 RA-96PLUS RA-96PLUS NHX Antibodies, Anti-Cyclic Citrullinated Peptide (Ccp) 2 IMMUNOSCAN CCPlus
Other products with the same Product Code "MSV"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00855360006236 11854 11854 INTENDED USEAn enzyme-linked immunoassay (ELISA) for the detection of IgG antibo INTENDED USEAn enzyme-linked immunoassay (ELISA) for the detection of IgG antibodies to complexes formed byoxidized low-density lipoprotein (oxLDL) with β2-glycoprotein I (β2GPI) in individuals with systemic lupuserythematosus (SLE) and lupus-like disorders (antiphospholipid syndrome). For In Vitro Diagnostic Use Only.SUMMARY AND EXPLANATION OF THE ASSAYThe antiphospholipid syndrome (APS) is one of the most common causes of acquired hypercoagulability(thrombophilia) It is frequently diagnosed in the context of a systemic autoimmune disorder such asSLE (secondary APS), however, it may also occur in the absence of an obvious underlying disease(primary APS). Oxidative stress and oxLDL formation are common in patients with SLE and APS suggesting an important relationship between lipid peroxidation and clotting activation (hypercoagulability). The presence of circulating IgG anti-oxLDL-β2GPI antibodies seem to be etiologically important. PRINCIPLE OF THE TESTThis test is an indirect ELISA detecting IgG anti-oxLDL-β2GPI antibodies. Diluted serum samples, calibrator(s), and controls are incubated in microwells coated with the oxLDL- β2GPI complex. After the removal of unbound serum proteins by washing, anti-human IgG antibodies, labeled with horseradish peroxidase (HRP), are added. Following another wash, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of IgG anti-oxLDL-β2GPI antibody. Results are obtained by reading the OD of each well in a spectrophotometer. Calibrator sera are provided, with the IgG anti-oxLDL-β2GPI antibody concentration expressed in G Units. A log-log regression analysis is performed with calibrator values plotted against calibrator mean O.D.’s. Controls and patient results are determined from the calibration curve. Refer to product package insert. Anti-AtherOxTM IgG Test Kit (OxLDL-B2GPI IgG Antibody) CORGENIX MEDICAL CORPORATION
2 00855360006199 13372 13372 INTENDED USE For the detection and semi-quantitation of IgA anti-β2GPl antibodie INTENDED USE For the detection and semi-quantitation of IgA anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.SUMMARY OF THE TEST Anti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgA anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgA, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgA anti-β2GPl antibody concentrations expressed in A units. Controls and patient results are determined from the calibration curve. Refer to product package insert. Corgenix Anti-Beta 2 Glycoprotein I IgA Semi-Quantitative Test Kit (192 Well) CORGENIX MEDICAL CORPORATION
3 00855360006182 13371 13371 INTENDED USE For the detection and semi-quantitation of IgM anti-β2GPl antibodie INTENDED USE For the detection and semi-quantitation of IgM anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.SUMMARY OF THE TEST Anti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgM anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl.. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgM, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgM anti-β2GPl antibody concentrations expressed in M units. Controls and patient results are determined from the calibration curve. Refer to Product package insert. Corgenix Anti-Beta 2 Glycoprotein I IgM Semi-Quantitative Test Kit (192 Well) CORGENIX MEDICAL CORPORATION
4 00855360006175 13370 13370 INTENDED USE For the detection and semi-quantitation of IgG anti-β2GPl antibodie INTENDED USE For the detection and semi-quantitation of IgG anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Use Only.SUMMARY AND EXPLANATION OF THE I TEST Anti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgG anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome. PRINCIPLE OF THE TEST The test is s an indirect ELISA. Diluted serum/ plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum/plasma proteins by washing, antibodies specific for human IgG, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgG anti-β2GPl antibody concentrations expressed in G units.. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert. Corgenix Anti-Beta 2 Glycoprotein I IgG Semi-Quantitative Test Kit (192 Well) CORGENIX MEDICAL CORPORATION
5 00855360006168 038-001 038-001 INTENDED USEFor the detection and semi-quantitation of IgM anti-β2GPl antibodies INTENDED USEFor the detection and semi-quantitation of IgM anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.SUMMARY OF THE TESTAnti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionicphospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgM anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.PRINCIPLE OF THE TESTThe test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgM, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgM anti-β2GPl antibody concentrations expressed in M units. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert. REAADS Anti-Beta 2 Glycoprotein I IgM Semi-Quantitative Test Kit (96 Well) CORGENIX MEDICAL CORPORATION
6 00855360006151 037-001 037-001 INTENDED USEFor the detection and semi-quantitation of IgG anti-β2GPl antibodies INTENDED USEFor the detection and semi-quantitation of IgG anti-β2GPl antibodies in individuals with systemic lupuserythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Use Only.SUMMARY OF THE TESTAnti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgG anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.PRINCIPLE OF THE TESTThe test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgG, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgG anti-β2GPl antibody concentrations expressed in G units. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert. REAADS Anti-Beta 2 Glycoprotein I IgG Semi-Quantitative Test Kit (96 Well) CORGENIX MEDICAL CORPORATION
7 00855360006144 039-001 039-001 INTENDED USEFor the detection and semi-quantitation of IgA anti-β2GPl antibodies INTENDED USEFor the detection and semi-quantitation of IgA anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Use Only.SUMMARY OF THE TESTAnti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgA anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.PRINCIPLE OF THE TESTThe test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgA, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgA anti-β2GPl antibody concentrations expressed in A units. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert. REAADS Anti-Beta 2 Glycoprotein I IgA Semi-Quantitative Test Kit (96 Well) CORGENIX MEDICAL CORPORATION
8 00847865012997 SW4.1_1 6652165B Manual & CDs, APLS IgA IFU, SW4.1_v1, US Only BioPlex 2200 BIO-RAD LABORATORIES, INC.
9 00847865012980 SW4.1V1 6652065B Manual & CDs, APLS IgM IFU, SW4.1_v1 BioPlex 2200 BIO-RAD LABORATORIES, INC.
10 00847865012973 SW4.1V1 6651975B APLS IgG, IgM and IgA Assay Protocol File CD, SW4.1_v1 US Only BioPlex 2200 BIO-RAD LABORATORIES, INC.
11 00847865012966 SW4.1V1 6651965B Manual & CDs, APLS IgG IFU, SW4.1_v1, US Only BioPlex 2200 BIO-RAD LABORATORIES, INC.
12 00847865012522 SW4_1 6651965A Manual & CDs, BioPlex 2200 APLS IgG IFU, SW4_v1, US Only BioPlex 2200 BIO-RAD LABORATORIES, INC.
13 00847865012515 SW4_1 6652065A Manual & CDs, APLS IgM IFU, SW4_v1, US Only BioPlex 2200 BIO-RAD LABORATORIES, INC.
14 00847865012508 SW4_1 6651975A APLS IgG, IgM and IgA Assay Protocol File CD, SW4_v1 BioPlex 2200 BIO-RAD LABORATORIES, INC.
15 00847865002998 SW4_1 6652165A Manual & CDs, APLS IgA IFU, SW4_v1, US Only BioPlex 2200 BIO-RAD LABORATORIES, INC.
16 00847865000710 6652150 6652150 APLS IgA Reagent Pack BioPlex 2200 BIO-RAD LABORATORIES, INC.
17 00847865000666 6652050 6652050 APLS IgM Reagent Pack BioPlex 2200 BIO-RAD LABORATORIES, INC.
18 00847865000604 6651950 6651950 APLS IgG Reagent Pack BioPlex 2200 BIO-RAD LABORATORIES, INC.
19 00847817018282 425-2160 425-2160 Autoimmune EIA Anti-Phosphatidylserine IgA Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
20 00847817018275 425-2140 425-2140 Autoimmune EIA Anti-Phosphatidylserine IgM Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
21 00847817018268 425-2120 425-2120 Autoimmune EIA Anti-Phosphatidylserine IgG Test Autoimmune EIA BIO-RAD LABORATORIES, INC.
22 00847817018251 425-2100 425-2100 Autoimmune EIA Anti-ß2 Glycoprotein I IgA Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
23 00847817018244 425-2080 425-2080 Autoimmune EIA Anti-?2 Glycoprotein I IgM Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
24 00847817018237 425-2060 425-2060 Autoimmune EIA Anti-ß2 Glycoprotein I IgG Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
25 00847817018220 425-2040 425-2040 Autoimmune EIA Anti-Cardiolipin IgA Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
26 00847817018213 425-2020 425-2020 Autoimmune EIA Anti-Cardiolipin IgM Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
27 00847817018206 425-2000 425-2000 Autoimmune EIA Anti-Cardiolipin IgG Test Kit Autoimmune EIA BIO-RAD LABORATORIES, INC.
28 00845714004353 2308 2308 Serum Diluent IMMCO DIAGNOSTICS IMMCO DIAGNOSTICS, INC.
29 00845714004247 2308-1 2308-1 WASH BUFFER IMMCO DIAGNOSTICS IMMCO DIAGNOSTICS, INC.
30 00845714002939 2513 2513 Enzyme Substrate IMMCO DIAGNOSTICS IMMCO DIAGNOSTICS, INC.
31 00845714002793 2310 2310 Stop Solution IMMCO DIAGNOSTICS IMMCO DIAGNOSTICS, INC.
32 00845714002458 5152S 5152S B2GP1 Screen ELISA Immco DIagnostics, Inc. IMMCO DIAGNOSTICS, INC.
33 00845714002441 5152M 5152M B2GP1 IgM ELISA Immco Diagnostics, Inc. IMMCO DIAGNOSTICS, INC.
34 00845714002434 5152G 5152G B2GP1 IgG ELISA Immco DIagnostics, Inc. IMMCO DIAGNOSTICS, INC.
35 00845714002427 5152A 5152A B2GP1 IgA ELISA Immco Diagnostics, Inc IMMCO DIAGNOSTICS, INC.
36 00845714000645 1152M 1152M Anti-B2-GP1 IgG Antibody ELISA IMMCO DIAGNOSTICS IMMCO DIAGNOSTICS, INC.
37 00845714000638 1152G 1152G Anti-B2-GP1 IgG Antibody ELISA IMMCO DIAGNOSTICS IMMCO DIAGNOSTICS, INC.
38 00817273020402 720-830 "720-830 anti-β2 Glycoprotein I IgG/IgM Test Kit" Diamedix DIAMEDIX CORPORATION
39 00816879020243 FGA24 96 well ELISA for the detection of Anti-B2-Glycoprotein I IgA antibodies in human serum Autostat II Anti-B2-Glycoprotein I IgA HYCOR BIOMEDICAL LLC
40 00816879020236 FGA23 96 well ELISA for the detection of Anti-B2-Glycoprotein I IgM antibodies in human serum Autostat II Anti-B2-Glycoprotein I IgM HYCOR BIOMEDICAL LLC
41 00816879020229 FGA22 96 well ELISA for the detection of Anti-B2-Glycoprotein I IgG antibodies in human serum Autostat II Anti-B2-Glycoprotein I IgG HYCOR BIOMEDICAL LLC
42 B24235B2SHUE010 35-B2SHU-E01 35-B2SHU-E01 Anti-Beta 2 Glycoprotein Screen ELISA is a solid phase enzyme immunoassay employ Anti-Beta 2 Glycoprotein Screen ELISA is a solid phase enzyme immunoassay employing native Beta-2glycoprotein I highly purified from human plasma for the combined quantitative and qualitative detection of IgA, IgG and IgM antibodies against Beta-2-glycoprotein I in human serum. Anti-Beta 2 Glycoprotein Screen ELISA AMERICAN LABORATORY PRODUCTS COMPANY, LTD.
43 08426951298778 00009800015 00009800015 1. HemosIL Acustar ß2GP1-Domain1 Reagent Cartridge (Cat. No. 000098000162. 1 Re 1. HemosIL Acustar ß2GP1-Domain1 Reagent Cartridge (Cat. No. 000098000162. 1 Resuspension buffer (Cat. No. 00009800019) 3. 1 HemosIL Acustar ß2GP1-Domain1 Calibrator 1 (Cat. No. 00009800017):4. 1 HemosIL Acustar ß2GP1-Domain1 Calibrator 2 (Cat. 00009800018): HemosIL AcuStar Anti-B2GPI Domain 1 INSTRUMENTATION LABORATORY COMPANY
44 08426951289271 701250 1. 1 QUANTA Flash B2GP1 IgM Reagent Cartridge2. 1 QUANTA Flash B2GP1 IgM Calibr 1. 1 QUANTA Flash B2GP1 IgM Reagent Cartridge2. 1 QUANTA Flash B2GP1 IgM Calibrator 1 3. 1 QUANTA Flash B2GP1 IgM Calibrator 2 QUANTA Flash® B2GP1 IgM Reagents INOVA DIAGNOSTICS, INC.
45 08426951289264 701245 1 QUANTA Flash B2GP1 IgG Reagent Cartridge1 QUANTA Flash B2GP1 IgG Calibrator 1 1 QUANTA Flash B2GP1 IgG Reagent Cartridge1 QUANTA Flash B2GP1 IgG Calibrator 1 1 QUANTA Flash B2GP1 IgG Calibrator 2 QUANTA Flash® B2GP1 IgG Reagents INOVA DIAGNOSTICS, INC.
46 08426951289257 701240 1. 1 QUANTA Flash B2GP1 IgA Reagent Cartridge2. 1 QUANTA Flash B2GP1 IgA Calibra 1. 1 QUANTA Flash B2GP1 IgA Reagent Cartridge2. 1 QUANTA Flash B2GP1 IgA Calibrator 1 3. 1 QUANTA Flash B2GP1 IgA Calibrator 2 QUANTA Flash® B2GP1 IgA Reagents INOVA DIAGNOSTICS, INC.
47 08426950601951 701188 1. 1 QUANTA Flash ß2GP1-Domain1 Reagent Cartridge2. 1 Resuspension buffer 3. 1 T 1. 1 QUANTA Flash ß2GP1-Domain1 Reagent Cartridge2. 1 Resuspension buffer 3. 1 Transfer pipet4. 1 QUANTA Flash ß2GP1-Domain1 Calibrator 15. 1 QUANTA Flash ß2GP1-Domain1 Calibrator 2 QUANTA Flash® B2GP1-Domain 1Reagents INOVA DIAGNOSTICS, INC.
48 08426950596820 701243 1. 1 QUANTA Flash ß2GP1 IgA Reagent Cartridge2. 1 QUANTA Flash ß2GP1 IgA Calibra 1. 1 QUANTA Flash ß2GP1 IgA Reagent Cartridge2. 1 QUANTA Flash ß2GP1 IgA Calibrator 1 3. 1 QUANTA Flash ß2GP1 IgA Calibrator 2 QUANTA Flash® β2GPI IgA Reagents INOVA DIAGNOSTICS, INC.
49 08426950595816 708665.10 1. 10 B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL pre 1. 10 B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL prediluted ELISA Negative Control 3. 5x 1.2mL prediluted 2 GPI IgG ELISA Control4. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator A5. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator B6. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator C7. 5x 1.2mL prediluted 2 GPI IgG ELISA Calibrator D8. 1x 1.2mL prediluted 2 GPI IgG ELISA Calibrator E9. 9x 50mL HRP Sample Diluent10. 10x 25mL HRP Wash Concentrate, 40x concentrate11. 10x 10mL 2 HRP IgG Conjugate, (goat), anti-human IgG12. 10x 10mL TMB Chromogen13. 10x 10mL HRP Stop Solution, 0.344M Sulfuric Acid QUANTA Lite® β2GPI IgG ELISA Bulk Pack INOVA DIAGNOSTICS, INC.
50 08426950594659 708675.10 1. 10x B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL pr 1. 10x B2 GPI ELISA microwell plates (12-1 x 8 wells), with holder2. 5x 1.2mL prediluted ELISA Negative Control 3. 5x 1.2mL prediluted 2 GPI IgA ELISA Control4. 5x 1.2mL prediluted 2 GPI IgA ELISA Calibrator A5. 5x 1.2mL prediluted 2 GPI IgA ELISA Calibrator B6. 5x 1.2mL prediluted 2 GPI IgA ELISA Calibrator C7. 5x 1.2mL prediluted 2 GPI IgA ELISA Calibrator D8. 5x 1.2mL prediluted 2 GPI IgA ELISA Calibrator E9. 9x 50mL HRP Sample Diluent10. 10x 25mL HRP Wash Concentrate, 40x concentrate11. 10x 10mL HRP IgA Conjugate, (goat), anti-human IgA12. 10x 10mL TMB Chromogen13. 10x 10mL HRP Stop Solution, 0.344M Sulfuric Acid QUANTA Lite® β2GPI IgA ELISA Bulk Pack INOVA DIAGNOSTICS, INC.