Other products from "RAPID MEDICAL LTD"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07290015107143 ANPP7188 The Comaneci is intended for use in the neurovasculature to assist in the coil e The Comaneci is intended for use in the neurovasculature to assist in the coil embolization of wide-necked intracranial aneurysms under fluoroscopic guidance. The Comaneci is comprised of a collapsible, fully retrievable, fine wire construction mounted on a wire shaft that expands to comply with the vessel diameter. It is delivered through a neurovascular microcatheter. The Comaneci is provided with a 3.5 French (F) peelable loading sheath. PUU Temporary Coil Embolization Assist Device Comaneci Petit
2 07290015107150 ANPP7199 The Comaneci is intended for use in the neurovasculature to assist in the coil e The Comaneci is intended for use in the neurovasculature to assist in the coil embolization of wide-necked intracranial aneurysms under fluoroscopic guidance. The Comaneci is comprised of a collapsible, fully retrievable, fine wire construction mounted on a wire shaft that expands to comply with the vessel diameter. It is delivered through a neurovascular microcatheter. The Comaneci is provided with a 3.5 French (F) peelable loading sheath. PUU Temporary Coil Embolization Assist Device Comaneci 17
3 07290015107303 TRPP7144 TRPP7144 The Tigertriever 13 device is a stentriever that is comprised of an adjustable n The Tigertriever 13 device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. The Tigertriever 13 Revascularization Device is supplied sterile and is intended for single-use only by physicians trained in neuro-interventional catheterization and the treatment of ischemic stroke. NRY Catheter, Thrombus Retriever 2 Tigertriever 13 Revascularization Device
4 07290015107242 DRSR7463 The Drivewire Guidewire is intended for general intravascular use, including the The Drivewire Guidewire is intended for general intravascular use, including the neuro and peripheral vasculature. The Drivewire Guidewire is intended to facilitate the selective placement of diagnostic or therapeutic catheters. This device is not intended for use in coronary arteries. MOF,DQX Guide, Wire, Catheter, Neurovasculature,Wire, Guide, Catheter Drivewire SR
5 07290015107136 ANPP7177 The Comaneci is intended for use in the neurovasculature to assist in the coil e The Comaneci is intended for use in the neurovasculature to assist in the coil embolization of wide-necked intracranial aneurysms under fluoroscopic guidance. The Comaneci is comprised of a collapsible, fully retrievable, fine wire construction mounted on a wire shaft that expands to comply with the vessel diameter. It is delivered through a neurovascular microcatheter. The Comaneci is provided with a 3.5 French (F) peelable loading sheath. PUU Temporary Coil Embolization Assist Device Comaneci
6 07290015107266 TRPP7155 TRPP7155 The Tigertriever device is a stentriever that is comprised of an adjustable niti The Tigertriever device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. Two versions of the device are available. The standard version Tigertriever (TRPP7155) has a net length of 32mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.021 inches. The shorter version Tigertriever 17 (TRPP7166) has a net length of 23 mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.017 inches. The Tigertriever is provided with a 3.5 Fr peelable loading sheath. NRY Catheter, Thrombus Retriever Tigertriever Revascularization Device
7 07290015107273 TRPP7166 The Tigertriever device is a stentriever that is comprised of an adjustable niti The Tigertriever device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. Two versions of the device are available. The standard version Tigertriever (TRPP7155) has a net length of 32mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.021 inches. The shorter version Tigertriever 17 (TRPP7166) has a net length of 23 mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.017 inches. The Tigertriever is provided with a 3.5 Fr peelable loading sheath. NRY Catheter, Thrombus Retriever Tigertriever 17 Revascularization Device
Other products with the same Product Codes "MOF, DQX"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00857834006971 SP-4089-801 NeoWire HERAEUS MEDICAL COMPONENTS LLC
2 00857834006902 18300376NW-AFB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
3 00857834006896 18300376NW-FB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
4 00857834006889 18180376NW-AFB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
5 00857834006872 18180376NW-FB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
6 00857834006865 18080280NW-ASL Selectiva HERAEUS MEDICAL COMPONENTS, LLC
7 00857834006858 18080280NW-SL Selectiva HERAEUS MEDICAL COMPONENTS, LLC
8 00857834006841 18060280NW-ASL Selectiva HERAEUS MEDICAL COMPONENTS, LLC
9 00857834006834 18060280NW-SL Selectiva HERAEUS MEDICAL COMPONENTS, LLC
10 00857834006827 3530004S-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
11 00857834006810 3518004S-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
12 00857834006803 3514504S-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
13 00857834006797 3508004S-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
14 00857834006780 3530004A-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
15 00857834006773 3518004A-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
16 00857834006766 3514504A-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
17 00857834006759 3508004A-SB Selectiva HERAEUS MEDICAL COMPONENTS, LLC
18 00857834006728 3530004A Selectiva HERAEUS MEDICAL COMPONENTS, LLC
19 00857834006711 3518004A Selectiva HERAEUS MEDICAL COMPONENTS, LLC
20 00857834006704 3514504A Selectiva HERAEUS MEDICAL COMPONENTS, LLC
21 00857834006698 3518004S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
22 00857834006681 3518004S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
23 00857834006674 3514504S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
24 00857834006667 3508004S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
25 00857834006650 1830004A Selectiva HERAEUS MEDICAL COMPONENTS, LLC
26 00857834006643 1808004A Selectiva HERAEUS MEDICAL COMPONENTS, LLC
27 00857834006636 1808004A Selectiva HERAEUS MEDICAL COMPONENTS, LLC
28 00857834006629 1806004A Selectiva HERAEUS MEDICAL COMPONENTS, LLC
29 00857834006612 1830004S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
30 00857834006599 1818004S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
31 00857834006582 1808004S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
32 00857834006575 1806004S Selectiva HERAEUS MEDICAL COMPONENTS, LLC
33 00857834006568 PW-16130-HN Arrow Marked Guidewire HERAEUS MEDICAL COMPONENTS LLC
34 00857834006537 SP-4089-521 NeoWire HERAEUS MEDICAL COMPONENTS LLC
35 00857834006520 SP-4089-520 NeoWire HERAEUS MEDICAL COMPONENTS LLC
36 00857834006513 SP-4089-501 Neowire HERAEUS MEDICAL COMPONENTS LLC
37 00857834006506 SP-4089-500 NeoWire HERAEUS MEDICAL COMPONENTS LLC
38 00857834006490 SP-4089-125 NeoWire HERAEUS MEDICAL COMPONENTS LLC
39 00857834006483 SP-4089-124 NeoWire HERAEUS MEDICAL COMPONENTS LLC
40 00857834006476 SP-4089-123 NeoWire HERAEUS MEDICAL COMPONENTS LLC
41 00857834006469 SP-4089-117 NeoWire HERAEUS MEDICAL COMPONENTS LLC
42 00857834006452 SP-4089-116 NeoWire HERAEUS MEDICAL COMPONENTS LLC
43 00857834006445 SP-4089-110 NeoWire HERAEUS MEDICAL COMPONENTS LLC
44 00857834006438 SP-4089-103 NeoWire HERAEUS MEDICAL COMPONENTS LLC
45 00857834006421 SP-4089-102 NeoWire HERAEUS MEDICAL COMPONENTS LLC
46 00857834006414 SP-4089-101 NeoWire HERAEUS MEDICAL COMPONENTS LLC
47 00857834006407 SP-4089-100 NeoWire HERAEUS MEDICAL COMPONENTS LLC
48 00857834006391 SCG-005 Spring Coil Guidewire HERAEUS MEDICAL COMPONENTS LLC
49 00857834006063 SCG-004 Spring Coil Guidewire HERAEUS MEDICAL COMPONENTS LLC
50 00857834006056 SCG-003 Spring Coil Guidewire HERAEUS MEDICAL COMPONENTS LLC