Other products from "NORDICNEUROLAB AS"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07090042052061 CRI-1.0 Control Room Interface (CRI) is part of Visual System HD.CRI is the interface un Control Room Interface (CRI) is part of Visual System HD.CRI is the interface unit for video signal in (HDMI) and eye tracking video out (HDMI).The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays, Visual System HD. LNH System, Nuclear Magnetic Resonance Imaging 2 Control Room Interface
2 07090042052092 VPS-1.1 Visual System Power Supply (VPS) for NordicNeuroLab's Visual System HDShielded e Visual System Power Supply (VPS) for NordicNeuroLab's Visual System HDShielded enclosure containing the Power Supply Unit for the Visual System HD which is located in the MR environment. VPS is part of NordicNeuroLab’s VisualSystem HD. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays. LNH System, Nuclear Magnetic Resonance Imaging 2 Visual System Power Supply
3 07090042051064 LCD 3.1 NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard HDMI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with an integrated VGA camera. LNH System, Nuclear Magnetic Resonance Imaging 2 Inroom Viewing Device
4 07090042051033 LDC 3.0 NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard DVI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with a integrated VGA camera. LNH System, Nuclear Magnetic Resonance Imaging 2 Inroom Viewing Device
5 07090042054058 SB- 3.2 SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directl SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings. LNH System, Nuclear Magnetic Resonance Imaging 2 SyncBox
6 07090042054034 SB 3.0 SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directl SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings. LNH System, Nuclear Magnetic Resonance Imaging 2 SyncBox
7 07090042054010 4.0 The ResponseGrip is an MRI-safe patient response device, providing real-time fee The ResponseGrip is an MRI-safe patient response device, providing real-time feedback of a patient response. The ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. LNH System, Nuclear Magnetic Resonance Imaging 2 ResponseGrips
8 07090042055017 FLT 2.1 Fiberlink transmitter is part of NordicNeuroLab’s fMRI System.Fiberlink transmit Fiberlink transmitter is part of NordicNeuroLab’s fMRI System.Fiberlink transmitter converts audio and video signals into an optical signal for transmission.Fiberlink transmitter is used togheter with NordicNeuroLab’s Visual System and Audio System. LNH System, Nuclear Magnetic Resonance Imaging 2 Fiberlink transmitter
9 07090042054041 RGI-2.2 ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Re ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PCThe ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. LNH System, Nuclear Magnetic Resonance Imaging 2 ResponseGrip Interface
10 07090042053020 HPS 1.0 Head Phones Slim is part of NordicNeuroLab’s Audio System.The AudioSystem allows Head Phones Slim is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone Slim is designed specifically for use in the MR environment, and are compatible with MR system up to 3T. LNH System, Nuclear Magnetic Resonance Imaging 2 HeadPhones Slim
11 07090042051057 LPS-3.1 LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosur LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosure containing the Power Supply Unit for the LCD Monitor which is located in the MR environment. LPS is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor. LNH System, Nuclear Magnetic Resonance Imaging 2 LCD Power Supply
12 07090042051040 LPS 3.0 LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosur LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosure containing the Power Supply Unit for the LCD Monitor which is located in the MR environment. LPS is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor. LNH System, Nuclear Magnetic Resonance Imaging 2 LCD Power Supply
13 07090042059046 1.1 LLZ System, Image Processing, Radiological 2 nordicDSC
14 07090042052085 VHD-1.1 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD) LNH System, Nuclear Magnetic Resonance Imaging 2 Visual System HD
15 07090042052108 VHD-1.2 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD) LNH System, Nuclear Magnetic Resonance Imaging 2 Visual System HD
16 07090042052023 ETC 2.0 LNH System, Nuclear Magnetic Resonance Imaging 2 Eye Tracker Camera
17 07090042059022 1.3 NordicNeuroLab’s nordicAktiva is a stimulus presentation and workflow software w NordicNeuroLab’s nordicAktiva is a stimulus presentation and workflow software which controls the presentation of stimuli during fMRI exams and has been designed specifically with the clinical user in mind. With an intuitive interface and detailed, easy-to-follow instructions, the user is guided step-by-step through the process of presenting stimuli during MR image acquisition. nordicAktiva runs on the stimulus presentation PC to which the NNL fMRI Hardware System is connected. Through the latter audiovisual stimuli are presented to, and feedback is collected from the patient. LNH System, Nuclear Magnetic Resonance Imaging 2 nordicAktiva
18 07090042059015 2.3 The nordicBrainEx Software is a post-processing application for dynamic MRI data The nordicBrainEx Software is a post-processing application for dynamic MRI data developed with focuson ease of use and high performance on a standard Windows workstation. The software providescomprehensive functionality for dynamic image analysis and visualization of MRI data, where signalchanges over time are analyzed to determine various modality dependent functional parameters. Thefollowing algorithms provide the main functional analyses of the application.- BOLD: BOLD fMRI analysis is used to highlight small magnetic susceptibility changes in thehuman brain in areas with altered blood-flow resulting from neuronal activity.- DTI: Diffusion analysis is used to visualize local water diffusion properties from the analysis ofdiffusion-weighted MRI data. Fiber tracking utilizes the directional dependency of the diffusionto display the white matter structure in the brain.- DSC: Calculations of perfusion related parameters that provide information about the bloodvessel structure and characteristics. Examples of such maps are blood volume, blood flow, timeto peak, mean transit time and leakage.In addition to these specific functional analyses, the application also provides general visualization tools,a database for data handling, and a reporting feature. This is to ensure that the workflow of theapplication is optimized to ensure efficiency and high throughput in a clinical environment. LLZ System, Image Processing, Radiological 2 nordicBrainEx
19 07090042055024 SIU 2.0 Shielded Interface Unit (SIU) is part of NordicNeuroLab’s fMRI System.SIU is a s Shielded Interface Unit (SIU) is part of NordicNeuroLab’s fMRI System.SIU is a shielded enclosure for the Power Supply Unit, Electrostatic Energizer (audio amplifier), Optical Electrical Adapter Unit and Display Interface. SIU is used togheter with NordicNeuroLab’s Visual System and Audio System.SIU hardware configuration is dependent on the system setup and which Visual System components and Audio System components that are included in the fMRI system LNH System, Nuclear Magnetic Resonance Imaging 2 Shielded Interface Unit
20 07090042053044 CC 2.3 CommunicationConsole is part of NordicNeuroLab’s Audio System.The AudioSystem al CommunicationConsole is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. The Communication Console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone. LNH System, Nuclear Magnetic Resonance Imaging 2 CommunicationConsole
21 07090042052078 1.1 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD)The VisualSystem Power Cable (VPC) provides connection between the VisualSystem Power Supply (VPS) And the coil mounted displays (VHD) LNH System, Nuclear Magnetic Resonance Imaging 2 VisualSystem Power Cable (VPC)
22 07090042053013 HP 1.3 Head Phones is part of NordicNeuroLab’s Audio System.The AudioSystem allows audi Head Phones is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone is designed specifically for use in the MR environment, and are compatible with MR system up to 3T. LNH System, Nuclear Magnetic Resonance Imaging 2 Headphones
23 07090042052016 CMD 2.3 Coil Mounted Display is part of NordicNeuroLab’s VisualSystem. The VisualSystem Coil Mounted Display is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.Coil Mounted Display is a flexible solution for presenting visual stimuli inside the MR scanner, which is based on OLED technology. LNH System, Nuclear Magnetic Resonance Imaging 2 Coil Mounted Display
Other products with the same Product Code "LNH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 08800086200019 V-B-mN1-01 Veuron-Brain-mN1 HEURON CO.,LTD.
2 08056304454744 100009910 Magnifico MSK ESAOTE SPA
3 08056304454737 100009900 Magnifico Open ESAOTE SPA
4 08056304451095 9800020010 S-scan ESAOTE SPA
5 08056304450081 101003000 O-scan ESAOTE SPA
6 08056304450074 9800020015 Standard Configuration S-scan ESAOTE SPA
7 08056304450029 101002000 G-scan Brio ESAOTE SPA
8 07350140460312 US031 AMRA Profiler 4 AMRA MEDICAL AB
9 07340024700030 11 SyMRI is a post-processing software medical device intended for use in visualiza SyMRI is a post-processing software medical device intended for use in visualization of the brain. SyMRI analyzes input data from MR imaging systems. SyMRI utilizes data from a multi-delay, multi-echo acquisition (MDME) to generate parametric maps of R1, R2 relaxation rates, and proton density (PD). SyMRI can generate multiple image contrasts from the parametric maps. SyMRI enables post-acquisition image contrast adjustment. SyMRI is indicated for head imaging.SyMRI is also intended for automatic labeling, visualization and volumetric quantification of segmentable brain tissues from a set of MR images. Brain tissue volumes are determined based on modeling of parametric maps from MDME images. When interpreted by a trained physician, SyMRI images can provide information useful in determining diagnosis. SyMRI should always be used in combination with at least one other, conventional MR acquisition (e.g. T2-FLAIR). SyMRI SYNTHETICMR AB (PUBL)
10 07340024700023 10 SyMRI is a post-processing software medical device intended for use in visualiza SyMRI is a post-processing software medical device intended for use in visualization of the brain. SyMRI analyzes input data from MR imaging systems. SyMRI utilizes data from a multi-delay, multi-echo acquisition (MDME) to generate parametric maps of R1, R2 relaxation rates, and proton density (PD). SyMRI can generate multiple image contrasts from the parametric maps. SyMRI enables post-acquisition image contrast adjustment. SyMRI is indicated for head imaging.When interpreted by a trained physician, SyMRI images can provide information useful in determining diagnosis. SyMRI should always be used in combination with at least one other, conventional MR acquisition (e.g. T2-FLAIR). SyMRI SYNTHETICMR AB (PUBL)
11 07090042059022 1.3 NordicNeuroLab’s nordicAktiva is a stimulus presentation and workflow software w NordicNeuroLab’s nordicAktiva is a stimulus presentation and workflow software which controls the presentation of stimuli during fMRI exams and has been designed specifically with the clinical user in mind. With an intuitive interface and detailed, easy-to-follow instructions, the user is guided step-by-step through the process of presenting stimuli during MR image acquisition. nordicAktiva runs on the stimulus presentation PC to which the NNL fMRI Hardware System is connected. Through the latter audiovisual stimuli are presented to, and feedback is collected from the patient. nordicAktiva NORDICNEUROLAB AS
12 07090042055024 SIU 2.0 Shielded Interface Unit (SIU) is part of NordicNeuroLab’s fMRI System.SIU is a s Shielded Interface Unit (SIU) is part of NordicNeuroLab’s fMRI System.SIU is a shielded enclosure for the Power Supply Unit, Electrostatic Energizer (audio amplifier), Optical Electrical Adapter Unit and Display Interface. SIU is used togheter with NordicNeuroLab’s Visual System and Audio System.SIU hardware configuration is dependent on the system setup and which Visual System components and Audio System components that are included in the fMRI system Shielded Interface Unit NORDICNEUROLAB AS
13 07090042055017 FLT 2.1 Fiberlink transmitter is part of NordicNeuroLab’s fMRI System.Fiberlink transmit Fiberlink transmitter is part of NordicNeuroLab’s fMRI System.Fiberlink transmitter converts audio and video signals into an optical signal for transmission.Fiberlink transmitter is used togheter with NordicNeuroLab’s Visual System and Audio System. Fiberlink transmitter NORDICNEUROLAB AS
14 07090042054058 SB- 3.2 SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directl SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings. SyncBox NORDICNEUROLAB AS
15 07090042054041 RGI-2.2 ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Re ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PCThe ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. ResponseGrip Interface NORDICNEUROLAB AS
16 07090042054034 SB 3.0 SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directl SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings. SyncBox NORDICNEUROLAB AS
17 07090042054027 2.0 ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Re ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PCThe ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. ResponseGrip Interface NORDICNEUROLAB AS
18 07090042054010 4.0 The ResponseGrip is an MRI-safe patient response device, providing real-time fee The ResponseGrip is an MRI-safe patient response device, providing real-time feedback of a patient response. The ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. ResponseGrips NORDICNEUROLAB AS
19 07090042053044 CC 2.3 CommunicationConsole is part of NordicNeuroLab’s Audio System.The AudioSystem al CommunicationConsole is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. The Communication Console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone. CommunicationConsole NORDICNEUROLAB AS
20 07090042053020 HPS 1.0 Head Phones Slim is part of NordicNeuroLab’s Audio System.The AudioSystem allows Head Phones Slim is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone Slim is designed specifically for use in the MR environment, and are compatible with MR system up to 3T. HeadPhones Slim NORDICNEUROLAB AS
21 07090042053013 HP 1.3 Head Phones is part of NordicNeuroLab’s Audio System.The AudioSystem allows audi Head Phones is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone is designed specifically for use in the MR environment, and are compatible with MR system up to 3T. Headphones NORDICNEUROLAB AS
22 07090042052108 VHD-1.2 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD) Visual System HD NORDICNEUROLAB AS
23 07090042052092 VPS-1.1 Visual System Power Supply (VPS) for NordicNeuroLab's Visual System HDShielded e Visual System Power Supply (VPS) for NordicNeuroLab's Visual System HDShielded enclosure containing the Power Supply Unit for the Visual System HD which is located in the MR environment. VPS is part of NordicNeuroLab’s VisualSystem HD. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays. Visual System Power Supply NORDICNEUROLAB AS
24 07090042052085 VHD-1.1 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD) Visual System HD NORDICNEUROLAB AS
25 07090042052078 1.1 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD)The VisualSystem Power Cable (VPC) provides connection between the VisualSystem Power Supply (VPS) And the coil mounted displays (VHD) VisualSystem Power Cable (VPC) NORDICNEUROLAB AS
26 07090042052061 CRI-1.0 Control Room Interface (CRI) is part of Visual System HD.CRI is the interface un Control Room Interface (CRI) is part of Visual System HD.CRI is the interface unit for video signal in (HDMI) and eye tracking video out (HDMI).The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays, Visual System HD. Control Room Interface NORDICNEUROLAB AS
27 07090042052023 ETC 2.0 Eye Tracker Camera NORDICNEUROLAB AS
28 07090042052016 CMD 2.3 Coil Mounted Display is part of NordicNeuroLab’s VisualSystem. The VisualSystem Coil Mounted Display is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.Coil Mounted Display is a flexible solution for presenting visual stimuli inside the MR scanner, which is based on OLED technology. Coil Mounted Display NORDICNEUROLAB AS
29 07090042051064 LCD 3.1 NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard HDMI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with an integrated VGA camera. Inroom Viewing Device NORDICNEUROLAB AS
30 07090042051057 LPS-3.1 LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosur LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosure containing the Power Supply Unit for the LCD Monitor which is located in the MR environment. LPS is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor. LCD Power Supply NORDICNEUROLAB AS
31 07090042051040 LPS 3.0 LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosur LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosure containing the Power Supply Unit for the LCD Monitor which is located in the MR environment. LPS is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor. LCD Power Supply NORDICNEUROLAB AS
32 07090042051033 LDC 3.0 NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard DVI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with a integrated VGA camera. Inroom Viewing Device NORDICNEUROLAB AS
33 06971576830114 uMR Omega uMR SHANGHAI UNITED IMAGING HEALTHCARE CO., LTD.
34 06971576830015 uMR 570 Magnetic Resonance Imaging System uMR SHANGHAI UNITED IMAGING HEALTHCARE CO., LTD.
35 06950743801058 ASM-050P (OPENMARK 5000) Magnetic Resonance Imaging System, Model: ASM-050P or OPENMARK 5000 ANKE SHENZHEN ANKE HIGH-TECH CO., LTD.
36 05745000363056 TCL3.2 The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system us The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system uses a markerless sensor based technology for tracking of patient movement during an MRI session. TCL3 Motion Tracking System TRACINNOVATIONS A/S
37 05745000363032 TCL3.2 The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system us The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system uses a markerless sensor based technology for tracking of patient movement during an MRI session. TCL3 Motion Tracking System TRACINNOVATIONS A/S
38 05745000363025 TCL3.2 The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system us The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system uses a markerless sensor based technology for tracking of patient movement during an MRI session. TCL3 Motion Tracking System TRACINNOVATIONS A/S
39 05745000363018 TCL3.2 The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system us The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system uses a markerless sensor based technology for tracking of patient movement during an MRI session. TCL3 Motion Tracking System TRACINNOVATIONS A/S
40 05745000363001 TCL3.2 The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system us The TCL3 Motion Tracking System is an accessory to an MRI scanner. The system uses a markerless sensor based technology for tracking of patient movement during an MRI session. TCL3 Motion Tracking System TRACINNOVATIONS A/S
41 05700002060471 2.7 Neuroreader BRAINREADER APS
42 05700002060464 2.6 Neuroreader BRAINREADER APS
43 05700002060457 2.5 Neuroreader BRAINREADER APS
44 05700002060440 2.4 Neuroreader BRAINREADER APS
45 05700002060433 2.3 Neuroreader BRAINREADER APS
46 05700002060419 2.2.9 Neuroreader BRAINREADER APS
47 05700002060402 2.2.8 Neuroreader BRAINREADER APS
48 05060608880515 11160006Z 11160006Z Radiation therapy QA device QED Detector, 15-25MV (-) 1.5m SUN NUCLEAR CORP.
49 05060608880508 11160003Z 11160003Z Radiation therapy QA device QED Detector, 15-25MV (+) 3m SUN NUCLEAR CORP.
50 05060608880492 11160002Z 11160002Z Radiation therapy QA device QED Detector, 15-25MV (-) 3m SUN NUCLEAR CORP.