Other products from "NORDICNEUROLAB AS"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 07090042052061 CRI-1.0 Control Room Interface (CRI) is part of Visual System HD.CRI is the interface un Control Room Interface (CRI) is part of Visual System HD.CRI is the interface unit for video signal in (HDMI) and eye tracking video out (HDMI).The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays, Visual System HD. LNH System, Nuclear Magnetic Resonance Imaging 2 Control Room Interface
2 07090042052092 VPS-1.1 Visual System Power Supply (VPS) for NordicNeuroLab's Visual System HDShielded e Visual System Power Supply (VPS) for NordicNeuroLab's Visual System HDShielded enclosure containing the Power Supply Unit for the Visual System HD which is located in the MR environment. VPS is part of NordicNeuroLab’s VisualSystem HD. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays. LNH System, Nuclear Magnetic Resonance Imaging 2 Visual System Power Supply
3 07090042051064 LCD 3.1 NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard HDMI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with an integrated VGA camera. LNH System, Nuclear Magnetic Resonance Imaging 2 Inroom Viewing Device
4 07090042051033 LDC 3.0 NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard DVI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with a integrated VGA camera. LNH System, Nuclear Magnetic Resonance Imaging 2 Inroom Viewing Device
5 07090042054058 SB- 3.2 SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directl SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings. LNH System, Nuclear Magnetic Resonance Imaging 2 SyncBox
6 07090042054034 SB 3.0 SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directl SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings. LNH System, Nuclear Magnetic Resonance Imaging 2 SyncBox
7 07090042054010 4.0 The ResponseGrip is an MRI-safe patient response device, providing real-time fee The ResponseGrip is an MRI-safe patient response device, providing real-time feedback of a patient response. The ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. LNH System, Nuclear Magnetic Resonance Imaging 2 ResponseGrips
8 07090042055017 FLT 2.1 Fiberlink transmitter is part of NordicNeuroLab’s fMRI System.Fiberlink transmit Fiberlink transmitter is part of NordicNeuroLab’s fMRI System.Fiberlink transmitter converts audio and video signals into an optical signal for transmission.Fiberlink transmitter is used togheter with NordicNeuroLab’s Visual System and Audio System. LNH System, Nuclear Magnetic Resonance Imaging 2 Fiberlink transmitter
9 07090042054041 RGI-2.2 ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Re ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PCThe ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. LNH System, Nuclear Magnetic Resonance Imaging 2 ResponseGrip Interface
10 07090042054027 2.0 ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Re ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PCThe ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces. LNH System, Nuclear Magnetic Resonance Imaging 2 ResponseGrip Interface
11 07090042053020 HPS 1.0 Head Phones Slim is part of NordicNeuroLab’s Audio System.The AudioSystem allows Head Phones Slim is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone Slim is designed specifically for use in the MR environment, and are compatible with MR system up to 3T. LNH System, Nuclear Magnetic Resonance Imaging 2 HeadPhones Slim
12 07090042051057 LPS-3.1 LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosur LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosure containing the Power Supply Unit for the LCD Monitor which is located in the MR environment. LPS is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor. LNH System, Nuclear Magnetic Resonance Imaging 2 LCD Power Supply
13 07090042059046 1.1 LLZ System, Image Processing, Radiological 2 nordicDSC
14 07090042052085 VHD-1.1 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD) LNH System, Nuclear Magnetic Resonance Imaging 2 Visual System HD
15 07090042052108 VHD-1.2 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD) LNH System, Nuclear Magnetic Resonance Imaging 2 Visual System HD
16 07090042052023 ETC 2.0 LNH System, Nuclear Magnetic Resonance Imaging 2 Eye Tracker Camera
17 07090042059022 1.3 NordicNeuroLab’s nordicAktiva is a stimulus presentation and workflow software w NordicNeuroLab’s nordicAktiva is a stimulus presentation and workflow software which controls the presentation of stimuli during fMRI exams and has been designed specifically with the clinical user in mind. With an intuitive interface and detailed, easy-to-follow instructions, the user is guided step-by-step through the process of presenting stimuli during MR image acquisition. nordicAktiva runs on the stimulus presentation PC to which the NNL fMRI Hardware System is connected. Through the latter audiovisual stimuli are presented to, and feedback is collected from the patient. LNH System, Nuclear Magnetic Resonance Imaging 2 nordicAktiva
18 07090042059015 2.3 The nordicBrainEx Software is a post-processing application for dynamic MRI data The nordicBrainEx Software is a post-processing application for dynamic MRI data developed with focuson ease of use and high performance on a standard Windows workstation. The software providescomprehensive functionality for dynamic image analysis and visualization of MRI data, where signalchanges over time are analyzed to determine various modality dependent functional parameters. Thefollowing algorithms provide the main functional analyses of the application.- BOLD: BOLD fMRI analysis is used to highlight small magnetic susceptibility changes in thehuman brain in areas with altered blood-flow resulting from neuronal activity.- DTI: Diffusion analysis is used to visualize local water diffusion properties from the analysis ofdiffusion-weighted MRI data. Fiber tracking utilizes the directional dependency of the diffusionto display the white matter structure in the brain.- DSC: Calculations of perfusion related parameters that provide information about the bloodvessel structure and characteristics. Examples of such maps are blood volume, blood flow, timeto peak, mean transit time and leakage.In addition to these specific functional analyses, the application also provides general visualization tools,a database for data handling, and a reporting feature. This is to ensure that the workflow of theapplication is optimized to ensure efficiency and high throughput in a clinical environment. LLZ System, Image Processing, Radiological 2 nordicBrainEx
19 07090042055024 SIU 2.0 Shielded Interface Unit (SIU) is part of NordicNeuroLab’s fMRI System.SIU is a s Shielded Interface Unit (SIU) is part of NordicNeuroLab’s fMRI System.SIU is a shielded enclosure for the Power Supply Unit, Electrostatic Energizer (audio amplifier), Optical Electrical Adapter Unit and Display Interface. SIU is used togheter with NordicNeuroLab’s Visual System and Audio System.SIU hardware configuration is dependent on the system setup and which Visual System components and Audio System components that are included in the fMRI system LNH System, Nuclear Magnetic Resonance Imaging 2 Shielded Interface Unit
20 07090042053044 CC 2.3 CommunicationConsole is part of NordicNeuroLab’s Audio System.The AudioSystem al CommunicationConsole is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. The Communication Console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone. LNH System, Nuclear Magnetic Resonance Imaging 2 CommunicationConsole
21 07090042052078 1.1 The VisualSystem HD allows video signals from the stimulus presentation PC to en The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD)The VisualSystem Power Cable (VPC) provides connection between the VisualSystem Power Supply (VPS) And the coil mounted displays (VHD) LNH System, Nuclear Magnetic Resonance Imaging 2 VisualSystem Power Cable (VPC)
22 07090042053013 HP 1.3 Head Phones is part of NordicNeuroLab’s Audio System.The AudioSystem allows audi Head Phones is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone is designed specifically for use in the MR environment, and are compatible with MR system up to 3T. LNH System, Nuclear Magnetic Resonance Imaging 2 Headphones
23 07090042052016 CMD 2.3 Coil Mounted Display is part of NordicNeuroLab’s VisualSystem. The VisualSystem Coil Mounted Display is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.Coil Mounted Display is a flexible solution for presenting visual stimuli inside the MR scanner, which is based on OLED technology. LNH System, Nuclear Magnetic Resonance Imaging 2 Coil Mounted Display
Other products with the same Product Code "LNH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10841962118726 10841962118726 RT-B889KYCF2A Encompass™ Fibreplast® Variable Perf Open View Anterior Only Encompass™ SRS Fibreplast® Anterior Mask QFIX
2 10841962111406 RT-B889KYCF RT-B889KYCF Encompass Head Only Open View Thermoplastic System Encompass™ SRS Fibreplast™ System QFIX
3 10841962111390 RT-B889KYCF2 RT-B889KYCF2 Encompass Fibreplast Variable Perf Open View Mask System Encompass™ SRS Fibreplast™ System QFIX
4 10841962111277 RT-5100-05 RT-5100-05 Lithotomy AirShuttle™ Lithotomy AirShuttle™ QFIX
5 10841962111260 RT-5100-04 RT-5100-04 BoS™ AirShuttle™ BoS™ AirShuttle™ QFIX
6 10841962111253 RT-5100-02 RT-5100-02 Portrait™ AirShuttle™ Portrait™ AirShuttle™ QFIX
7 10841962111246 RT-5100-01 RT-5100-01 Slate AirShuttle™ Slate AirShuttle™ QFIX
8 10841962111239 RT-5100 RT-5100 AirDrive Trolley™ AirDrive Trolley™ QFIX
9 10841962111123 RT-4558CB03 RT-4558CB03 ZiFix Traverse™ Abdominal/Thoracic Motion Control System ZiFix Traverse™ QFIX
10 10841962110980 RT-4800-B2 RT-4800-B2 InfinityLock™ SBRT Compression Bridge, Large InfinityLock™ QFIX
11 10841962110973 RT-4800-B1 RT-4800-B1 InfinityLock™ SBRT Compression Bridge, Small InfinityLock™ QFIX
12 10841962110966 RT-4800-01 RT-4800-01 Alta™ Multipurpose Device Alta™ QFIX
13 10841962110928 10841962110928 RT-B889KYCF2A Encompass™ Fibreplast® Variable Perf Open View Anterior Only Encompass™ SRS Fibreplast™ Anterior Mask QFIX
14 10841962110775 RT-4600-03-MRI RT-4600-03-MRI SRS MR Adapter for Portrait™ and S-Type Devices SRS MR Adapter QFIX
15 10841962110768 RT-4600-03 RT-4600-03 SRS Adapter for Portrait™ and S-Type Devices SRS Adapter QFIX
16 10841962110713 RT-5100-06 RT-5100-06 Symphony™ Brachytherapy Transfer Device with Cutout Symphony™ QFIX
17 10841962110706 RT-5100-05 RT-5100-05 Symphony™ Brachytherapy Transfer Device Symphony™ QFIX
18 10841962110508 RT-4558CB02 RT-4558CB02 ZiFix™ Abdominal/Thoracic Motion Control System ZiFix™ QFIX
19 10841962110447 RT-5100-04 RT-5100-04 Symphony™ Bos™ Transfer Device Symphony™ BoS™ QFIX
20 10841962109564 RT-5100-03 RT-5100-03 Symphony Brachytherapy Transfer Device Symphony™ QFIX
21 10841962109557 RT-5100-02 RT-5100-02 Symphony Portrait Head/Neck Transfer Device Symphony™ Portrait™ QFIX
22 10841962109540 RT-5100-01 RT-5100-01 Symphony Standard Transfer Device Symphony™ QFIX
23 10841962109533 RT-5100 RT-5100 Symphony™ Patient Trolley Symphony™ QFIX
24 10841962109526 RT-B889KYCF RT-B889KYCF Encompass Head Only Open View Thermoplastic System Encompass™ SRS Fibreplast™ System QFIX
25 10841962109519 RT-B889KYCF2 RT-B889KYCF2 Encompass Fibreplast Variable Perf Open View Mask System Encompass™ SRS Fibreplast™ System QFIX
26 10841962109502 RT-4600KV-01 RT-4600KV-01 kVue Encompass SRS Insert with E0 headrest & hand grip array Encompass™ QFIX
27 10841962109496 RT-4600-01-MRI RT-4600-01-MRI Encompass SRS MRI Standalone Device with E0 headrest & hand grip array Encompass™ QFIX
28 10841962109489 RT-4600-01 RT-4600-01 Encompass SRS Stand Alone Device with E0 headrest & hand grip array Encompass™ QFIX
29 10841439112585 MTAPCIN1832SG MTAPCIN1832SG Head-only open-face narrow thermoplastic with hair cover Solstice™ Thermoplastic Frame MEDTEC, INC.
30 10841439112578 MTAPCID1832SG MTAPCID1832SG Head-only open-face standard thermoplastic with hair cover Solstice™ Thermoplastic Frame MEDTEC, INC.
31 10841439112561 MTAPCIN1832 MTAPCIN1832 Head-only narrow thermoplastic with hair cover Solstice™ Thermoplastic Frame MEDTEC, INC.
32 10841439112554 MTAPCID1832 MTAPCID1832 Head-only standard thermoplastic with hair cover Solstice™ Thermoplastic Frame MEDTEC, INC.
33 10841439111328 MTAPUDMP MTAPUDMP Head-only FirmFit™ thermoplastic (2.3mm) SnapFrame™ Type-S™ Thermoplastic MEDTEC, INC.
34 10841439111311 MTAPUDMPSG MTAPUDMPSG Head-only open face FirmFit™ Thermoplastic (2.3mm) SnapFrame™ Type-S™ Thermoplastic MEDTEC, INC.
35 10841439111304 MTAPSDMP MTAPSDMP Head, neck and shoulder FirmFit™ thermoplastic (2.3mm) SnapFrame™ Type-S™ Thermoplastic MEDTEC, INC.
36 10841439110222 MTAPUIW1832VT MTAPUIW1832VT 30.5cm extra wide IMRT perforation thermoplastic (3.2mm) Uni-frame® Thermoplastic MEDTEC, INC.
37 10841439110215 MTAPUID1832CLRD MTAPUID1832CLRD 25.4cm head-only IMRT Style 18 Freedomview thermoplastic (3.2mm), Radius Bottom Type-S™ Thermoplastic MEDTEC, INC.
38 10841439110208 MTAPUID181332RD MTAPUID181332RD 35.6cm IMRT Style 18 thermoplastic (3.2mm) Radius Bottom Type-S™ Thermoplastic MEDTEC, INC.
39 10841439110185 991145 991145 LPR51 mask with profiles Mastercast™ Pro MEDTEC, INC.
40 10841439110178 990045 990045 LPR45 mask with profiles Mastercast™ Pro MEDTEC, INC.
41 10841439110161 990044 990044 LPR44 mask with profiles Mastercast™ Pro MEDTEC, INC.
42 10841439110154 960030 960030 PR3 Non-Perfo mask Posicast® Thermoplastic MEDTEC, INC.
43 10841439108885 MTVRTW MTVRTW Vision RT 3.2mm wide Uni-frame® Thermoplastic MEDTEC, INC.
44 10841439108878 MTVRTR MTVRTR Reloadable, Vision RT 3.2mm Uni-frame® Thermoplastic MEDTEC, INC.
45 10841439107048 MTPLHAI0203 MTPLHAI0203 45.7 x 55.9cm IMRT thermoplastic (3.2mm) HipFix® Thermoplastic MEDTEC, INC.
46 10841439107031 MTPLHA0202 MTPLHA0202 45.7 x 55.9cm standard perforated thermoplastic (3.2mm) HipFix® Thermoplastic MEDTEC, INC.
47 10841439107024 MTPLHA0201 MTPLHA0201 45.7 x 55.9cm solid thermoplastic (3.2mm) HipFix® Thermoplastic MEDTEC, INC.
48 10841439104320 MTHFX1822S MTHFX1822S 45.7 x 55.9cm solid thermoplastic (3.2mm) HipFix® Thermoplastic MEDTEC, INC.
49 10841439104313 MTHFX18222.4S MTHFX18222.4S 45.7 x 55.9cm solid thermoplastic (2.4mm) HipFix® Thermoplastic MEDTEC, INC.
50 10841439104306 MTHFX18222.4 MTHFX18222.4 45.7 x 55.9cm standard perforated thermoplastic (2.4mm) HipFix® Thermoplastic MEDTEC, INC.