Other products from "BEIJING CHOICE ELECTRONIC TECHNOLOGY CO., LTD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00846841060830 112-7063 Compressor Nebulizer CAF,BTI Nebulizer (Direct Patient Interface),Compressor, Air, Portable 2 Henry Schein
2 06942820462177 CFT-308C Choicemmed Infrared Thermometer CFT-308C FLL Thermometer, Electronic, Clinical 2 Choicemmed
3 06942820462146 MD300W628 Wrist pulse oximeter MD300W628 PGJ Oximeter, Wellness 2 Choicemmed
4 06942820462139 CFT-308 Infrared Thermometer CFT-308 FLL Thermometer, Electronic, Clinical 2 Choicemmed
5 06942820462085 MD300C23 Choicemmed Fingertip Pulse Oximeter MD300C23 DQA Oximeter 2 Choicemmed
6 06942820462047 MD300C29 Choicemmed Fingertip Pulse Oximeter MD300C29 DQA Oximeter Choicemmed
7 06942820462030 MD300C19 Choicemmed Fingertip Pulse Oximeter MD300C19 DQA Oximeter 2 Choicemmed
8 06942820461781 900-8275 handheld Pulse Oximeter DQA Oximeter 2 Henry Schein
9 06942820460944 MD300I12 Pulse Oximeter DQA Oximeter 2 ChoiceMMed
10 06942820460920 MD300M Pulse Oximeter DQA Oximeter 2 ChoiceMMed
11 00846841012686 MD300CG15 Talking Pulse Oximeter DQA Oximeter 2 ChoiceMMed
12 00846841070891 MD300CN340 mibest Fingtertip Pulse Oximeter MD300CN340 OCH Oximeter, Infrared, Sporting, Aviation 2 mibest
13 00846841070761 MD300CN140 mibest Fingtertip Pulse Oximeter MD300CN140 OCH Oximeter, Infrared, Sporting, Aviation 2 mibest
14 06942820462092 NS-PSOXMW1 INSIGNIA Fingertip Pulse Oximeter NS-PSOXMW1 OCH Oximeter, Infrared, Sporting, Aviation 2 INSIGNIA
15 06942820461767 VPOD Freedom Wrist Pulse Oximeter DQA Oximeter 2 Virtuox
16 06942820460883 MD300W1 Wrist Pulse Oximeter DQA Oximeter 2 ChoiceMMed
17 06942820461026 M-50G SpO2 Sensor DQA Oximeter 2 ChoiceMMed
18 06942820461019 M-50H SpO2 Sensor DQA Oximeter 2 ChoiceMMed
19 06942820461002 M-50A SpO2 Sensor DQA Oximeter 2 ChoiceMMed
20 06942820460999 M-50C SpO2 Sensor DQA Oximeter 2 ChoiceMMed
21 06942820460982 M-50E SpO2 Sensor DQA Oximeter 2 ChoiceMMed
22 06942820460975 M-50B SpO2 Sensor DQA Oximeter 2 ChoiceMMed
23 06942820460968 MD300A Pulse Oximeter DQA Oximeter 2 ChoiceMMed
24 06942820460951 MD300A-E Pulse Oximeter DQA Oximeter 2 ChoiceMMed
25 06942820460937 MD300K1 Pulse Oximeter DQA Oximeter 2 ChoiceMMed
26 06942820460913 MD300I1 Pulse Oximeter DQA Oximeter 2 ChoiceMMed
27 00846841040139 OxyWatch CG11 Fingertip Pulse Oximeter DQA Oximeter 2 ChoiceMMed
28 00846841040122 OxyWatch C6525 Fingertip Pulse Oximeter DQA Oximeter 2 ChoiceMMed
29 00846841040115 OxyWatch CF309 Fingertip Pulse Oximeter DQA Oximeter 2 ChoiceMMed
30 00846841040061 OxyWatch CF315 Fingertip Pulse Oximeter DQA Oximeter 2 ChoiceMMed
31 00846841092237 OxyWatch C9223 Fingertip Pulse Oximeter DQA Oximeter 2 ChoiceMMed
32 00846841080180 MDPS100 Self-adhesive Replacement Gel Pads GXY Electrode, Cutaneous 2 ChoiceMMed
33 00846841080173 MDTS116 Electronic Pulse Stimulator NGX,NUH Stimulator, Muscle, Powered, For Muscle Conditioning,Stimulator, Nerve, Transcut Stimulator, Muscle, Powered, For Muscle Conditioning,Stimulator, Nerve, Transcutaneous, Over-The-Counter 2 ChoiceMMed
34 00846841080166 MDTS111 Electronic Pulse Stimulator NGX,NUH Stimulator, Muscle, Powered, For Muscle Conditioning,Stimulator, Nerve, Transcut Stimulator, Muscle, Powered, For Muscle Conditioning,Stimulator, Nerve, Transcutaneous, Over-The-Counter 2 ChoiceMMed
35 00846841080067 BP10 (1.0) Blood Pressure Monitor DXN System, Measurement, Blood-Pressure, Non-Invasive 2 ChoiceMMed
36 00846841080043 BP11(1.0) Blood Pressure Monitor DXN System, Measurement, Blood-Pressure, Non-Invasive 2 ChoiceMMed
37 00846841071645 OxyWatch C29C ChoiceMMed Pulse Oximeter OxyWatch C29C OCH Oximeter, Infrared, Sporting, Aviation 2 ChoiceMMed
38 00846841070600 OxyWatch C2F ChoiceMMed Fingtertip Pulse Oximeter OxyWatch C2F OCH Oximeter, Infrared, Sporting, Aviation 2 ChoiceMMed
39 00846841070594 OxyWatch C1F ChoiceMMed Fingtertip Pulse Oximeter OxyWatch C1F OCH Oximeter, Infrared, Sporting, Aviation 2 ChoiceMMed
40 00846841070402 MDBP203 Wrist Blood Pressure Monitor DXN System, Measurement, Blood-Pressure, Non-Invasive 2 ChoiceMMed
41 00846841070242 T201 Infrared Ear Thermometer FLL Thermometer, Electronic, Clinical 2 ChoiceMMed
42 00846841061233 CBP1E3 Arm-type Fully Automatic Digital Blood Pressure Monitor DXN System, Measurement, Blood-Pressure, Non-Invasive 2 ChoiceMMed
43 00846841061226 CBP1E1 Arm-type Fully Automatic Digital Blood Pressure Monitor DXN System, Measurement, Blood-Pressure, Non-Invasive 2 ChoiceMMed
44 00846841060861 MDTS101 TENS-Transcutaneous electrical nerve stimulator for pain relief IPF,GZJ Stimulator, Muscle, Powered,Stimulator, Nerve, Transcutaneous, For Pain Relief 2 ChoiceMMed
45 00846841060854 T200 Infrared Ear Thermometer FLL Thermometer, Electronic, Clinical 2 ChoiceMMed
46 00846841060847 T100 Digital Thermometer FLL Thermometer, Electronic, Clinical 2 ChoiceMMed
47 00846841060823 BJ120105 Deluxe Blood Pressure Kit DXN System, Measurement, Blood-Pressure, Non-Invasive 2 ChoiceMMed
48 00846841060816 BJ120100 Automatic Blood Pressure Monitor DXN System, Measurement, Blood-Pressure, Non-Invasive 2 ChoiceMMed
49 00846841060762 MDN105 Compressor Nebulizer CAF,BTI Nebulizer (Direct Patient Interface),Compressor, Air, Portable 2 ChoiceMMed
50 00846841060755 BJ120110 Fully Automatic Digital Wrist Blood Pressure Monitor DXN System, Measurement, Blood-Pressure, Non-Invasive 2 Blue Jay
Other products with the same Product Code "DQA"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 07640121880971 PAK-SF A combination of single-use products intended to attach the Sentec Sensors to co A combination of single-use products intended to attach the Sentec Sensors to conventional measurement sites, recommended for adult, pediatric and neonatal patients with sensitive/fragile skin. Patient Application Kit for sensitive/fragile skin SENTEC AG
2 07640121880964 PAK-MI A combination of single-use products intended to attach the Sentec sensors to co A combination of single-use products intended to attach the Sentec sensors to conventional measurement sites, recommended for adult, pediatric and neonatal patients with mature/intact skin Patient Application Kit for mature intact skin SENTEC AG
3 07640121880957 PAK-EC A combination of single-use products intended to attach the Sentec sensors to th A combination of single-use products intended to attach the Sentec sensors to the earlobe of the patient, recommended for patients with mature/intact skin. Patient Application Kit with Ear Clip for mature/intact skin SENTEC AG
4 07640121880933 MC The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. The MC is single-use. Membrane Changer (single-use) / single unit SENTEC AG
5 07640121880902 RFT100VA-V1 Isolates the SDM from mains for use in home use environments. Isolation Transformer 100-120V SENTEC AG
6 07640121880889 SDM_WPC This cover will protect the SenTec Digital Monitor (SDM) from dripping water whe This cover will protect the SenTec Digital Monitor (SDM) from dripping water when the device is tilted up to 15° (IPX2). SDM Water Protection Cover SENTEC AG
7 07640121880858 GEL-04 The Contact Gel is required for proper CO2 gas conduction from the patient's ski The Contact Gel is required for proper CO2 gas conduction from the patient's skin to the SenTec TC Sensors. Every time a SenTec TC Sensor is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor membrane. Contact Gel 2ml SENTEC AG
8 07640121880810 ECe-MI Single patient use sensor application ear clip, recommended for adult, pediatric Single patient use sensor application ear clip, recommended for adult, pediatric and neonatal patients with mature/intact skin Ear Clip easy SENTEC AG
9 07640121880803 MARe-SF Single use sensor application ring, recommended for adult, pediatric and neonata Single use sensor application ring, recommended for adult, pediatric and neonatal patients with sensitive/fragile skin Multi-Site Attachment Ring for fragile/sensitive skin SENTEC AG
10 07640121880797 MARe-MI Single use sensor application ring, recommended for adult, pediatric and neonata Single use sensor application ring, recommended for adult, pediatric and neonatal patients with mature/intact skin Multi-Site Attachment Ring for mature/intact skin SENTEC AG
11 07640121880773 V-STATS_CD PC based software required a) to configure special (safety-relevant) settings of PC based software required a) to configure special (safety-relevant) settings of the SenTec Digital Monitor (SDM), b) to manage ‘SDM Parameters Settings’ and c) to download trend data from the internal memory of the SDM to a PC. It includes features to analyze and view the downloaded trend data. The V-STATS™ software includes the V-CareNeT™ Package, which enables remote monitoring and alarm surveillance for multiple SDMs being connected to the same network as the PC with V-STATS™. V-STATS™ Installation CD SENTEC AG
12 07640121880766 PSG Cable P The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable P SENTEC AG
13 07640121880759 SDM-PO2 Stand alone monitor with colour display for continuous non-invasive vital parame Stand alone monitor with colour display for continuous non-invasive vital parameter monitoring, with integrated docking station for sensor storage and calibration. SenTec Digital Monitor (with activated PO2 channel) SENTEC AG
14 07640121880742 OV-A/P/N Digital Sensor for non-invasive and continuous measurement of transcutaneous car Digital Sensor for non-invasive and continuous measurement of transcutaneous carbon dioxide and oxygen partial pressure as well as pulse oximetry. Suitable for adult, pediatric and neonatal patients. OxiVenT™ Sensor SENTEC AG
15 07640121880445 SSET-N_nG Neonatal Starter Set (without Service Gas) contains:Multi-Site Attachment Rings Neonatal Starter Set (without Service Gas) contains:Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) Neonatal Starter Set (without Service Gas) SENTEC AG
16 07640121880735 PSG Cable N The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable N SENTEC AG
17 07640121880728 PSG Cable M The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG). PSG Cable M SENTEC AG
18 07640121880711 PSG Cable L The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG). PSG Cable L SENTEC AG
19 07640121880704 PSG Cable K The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable K SENTEC AG
20 07640121880698 PSG Cable J The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable J SENTEC AG
21 07640121880681 PSG Cable H The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable H SENTEC AG
22 07640121880674 PSG Cable G The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable G SENTEC AG
23 07640121880667 PSG Cable F The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable F SENTEC AG
24 07640121880650 PSG Cable E The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable E SENTEC AG
25 07640121880643 PSG Cable D The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable D SENTEC AG
26 07640121880636 PSG Cable C The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable C SENTEC AG
27 07640121880629 PSG Cable B The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable B SENTEC AG
28 07640121880612 PSG Cable A The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG Cable A SENTEC AG
29 07640121880568 SA-MAR The Staysite Adhesive (SA-MAR), is an optional, single-use adhesive which is ind The Staysite Adhesive (SA-MAR), is an optional, single-use adhesive which is indicated for use with Multi-Site Attachment Rings, models MAR-MI and MAR-SF if more secure attachment is required. Staysite Adhesive SENTEC AG
30 07640121880513 VS-A/P/N Digital Sensor for non-invasive and continuous measurement of transcutaneous car Digital Sensor for non-invasive and continuous measurement of transcutaneous carbon dioxide partial pressure and pulse oximetry. Suitable for adult, pediatric and neonatal patients. V-Sign™ Sensor 2 SENTEC AG
31 07640121880506 MC-I The Membrane Changer (MC-R) is a reloadable tool to change the membrane of SenTe The Membrane Changer (MC-R) is a reloadable tool to change the membrane of SenTec TC Sensors. Prior reuse, the Membrane Changer (MC-R) must be reloaded with a new Membrane Changer Insert (MC-I). The MC-I is single-use Membrane Changer Inserts SENTEC AG
32 07640121880490 MC-SET The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC-R) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. To enable an economic and cost saving membrane change, the Membrane Changer after use can be reloaded with a new Membrane Changer Insert (MC-I). The memrane changer set contains the MC-R and inserts (MC-I) to reload.Membrane Changer Set [1 membrane changer, 1 insert] Membrane Changer Set SENTEC AG
33 07640121880438 SSET-N Neonatal Starter Set contains:Multi-Site Attachment Rings for mature/intact skin Neonatal Starter Set contains:Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) Neonatal Starter Set SENTEC AG
34 07640121880315 PSG-X The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Pol The PSG Adapter Cable is intended to interface the SenTec Digital Monitor to Polygraphs (PG) or Polysomnographs (PSG) PSG-X SENTEC AG
35 07640121880308 SSET_nG Standard Starter Set (without Service Gas) contains:Ear Clips (EC-MI)Multi-Site Standard Starter Set (without Service Gas) contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04) Standard Starter Set (without Service Gas) SENTEC AG
36 07640121880230 MAR-SF MAR-SF is intended to attach SenTec TC Sensors to various measurement sites for MAR-SF is intended to attach SenTec TC Sensors to various measurement sites for patients with sensitive, fragile but intact skin. Multi-Site Attachment Ring for fragile/sensitive skin SENTEC AG
37 07640121880223 MAR-MI MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for patients with mature, intact skin. Multi-Site Attachment Ring for mature/intact skin SENTEC AG
38 07640121880179 AC-750 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). Digital Sensor Adapter Cable, 750 cm SENTEC AG
39 07640121880162 AC-250 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). Digital Sensor Adapter Cable, 250 cm SENTEC AG
40 07640121880094 SSET Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for m Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812) Standard Starter Set SENTEC AG
41 07640121880087 MC-R The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC-R) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. To enable an economic and cost saving membrane change, the Membrane Changer after use can be reloaded with a new Membrane Changer Insert (MC-I). Membrane Changer (reloadable) / single unit SENTEC AG
42 07640121880070 GEL-04 The Contact Gel is required for proper CO2 gas conduction from the patient’s ski The Contact Gel is required for proper CO2 gas conduction from the patient’s skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor membrane. Contact Gel SENTEC AG
43 07640121880056 GAS-0812 The Service Gas is required for the calibration of the PCO2-part of SenTec TC Se The Service Gas is required for the calibration of the PCO2-part of SenTec TC Sensors. Depending on usage of the SDMS one Service Gas cylinder lasts for approx. 3 to 4 weeks. Service gas SENTEC AG
44 07640121880049 EC-MI The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. S The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. Suitable for patients with earlobes of sufficient size and mature, intact skin. Ear Clip SENTEC AG
45 07640121880032 AC-150 Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm). Digital Sensor Adapter Cable, 150 cm SENTEC AG
46 07640121880018 SDM Stand alone monitor with colour display for continuous non-invasive vital parame Stand alone monitor with colour display for continuous non-invasive vital parameter monitoring, with integrated docking station for sensor storage and calibration. SenTec Digital Monitor (without activated PO2 channel) SENTEC AG
47 07630002813549 1610090 1610090 HAMILTON-T1 HAMILTON MEDICAL AG
48 07630002813532 1610060 1610060 HAMILTON-T1 HAMILTON MEDICAL AG
49 07630002813426 1610010 1610010 HAMILTON-C1 HAMILTON MEDICAL AG
50 07630002806091 161009 161009 HAMILTON-T1 HAMILTON MEDICAL AG