Other products from "LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 06936733770320 3521 DXC Clamp, Vascular Vasc Band
2 06936733737057 SD-S35260 The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
3 06936733737071 SD-A35260 The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
4 06936733736920 SD-S35180 The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
5 06936733736944 SD-A35180 The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
6 06936733736876 ST-A35150 The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
7 06936733736852 ST-S35150 The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic The ULTRASKIN Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
8 06936733736814 SD-A35150 The ULTRASKINTM Hydrophilic Guide Wire consists of a Nitinol core wire, a plasti The ULTRASKINTM Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
9 06936733736777 SD-S35150 The ULTRASKINTM Hydrophilic Guide Wire consists of a Nitinol core wire, a plasti The ULTRASKINTM Hydrophilic Guide Wire consists of a Nitinol core wire, a plastic jacket with hydrophilic coating. The wire distal curve comes in different shapes such as straight, J angled and angled. The guide wire is radiopactitive under fluoroscopy. DQX Wire, Guide, Catheter 2 ULTRASKIN
10 06936733740927 RS070518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
11 06936733740910 RS061118S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
12 06936733740903 RS060725S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
13 06936733740897 RS060721S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
14 06936733740880 RS060718S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
15 06936733740873 RS060518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
16 06936733740866 RS051118S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
17 06936733740859 RS050725S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
18 06936733740842 RS050721S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
19 06936733740835 RS050718S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
20 06936733740828 RS050518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
21 06936733740811 RS041118S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
22 06936733740804 RS040725S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
23 06936733740798 RS040721S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
24 06936733740781 RS040718S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
25 06936733740774 RS040518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
26 06936733740194 RS071118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
27 06936733740187 RS070718S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
28 06936733740170 RS070518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
29 06936733740163 RS061118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
30 06936733740156 RS060725S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
31 06936733740149 RS060721S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
32 06936733740132 RS060718S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
33 06936733740125 RS060518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
34 06936733740118 RS051118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
35 06936733740101 RS050725S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
36 06936733740002 RS050721S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
37 06936733739983 RS050518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
38 06936733739976 RS041118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
39 06936733739969 RS040725S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
40 06936733739952 RS040721S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
41 06936733739945 RS040718S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
42 06936733739938 RS040518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
43 06936733739877 RS061118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
44 06936733739860 RS051118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
45 06936733739853 RS041118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
46 06936733737576 FS081135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
47 06936733737552 FS071135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
48 06936733737538 FS061135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
49 06936733737514 FS051135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
50 06936733737484 RS071118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. DYB Introducer, Catheter 2 Shoocin
Other products with the same Product Code "DYB"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00886333601561 680156 680156 Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve O Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.70mm x ID 2.90mmx 10cm and Dilator, guidewire 0.9x450mm, Introducers 1.4x70mm, stopcock SHEATH INTRO POP KIT 9FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
2 00886333601547 680154 680154 Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve O Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.35mm x ID 2.51mmx 10cm and Dilator, guidewire 0.9x450mm, Introducers 1.7x70mm,1.4x70mm, stopcock, syringe, scalpel. SHEATH INTRO LINK KIT 8FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
3 00886333601523 680152 680152 Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve O Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve OD 2.76mm x ID 1.90mm x 10cm and Dilator, guidewire 0.9x450mm, Introducers 1.7x70mm,1.4x70mm, stopcock, syringe, scalpel. SHEATH INTRO LINK KIT 6FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
4 00886333601509 680150 680150 Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve O Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.02mm x ID 2.28mm x 10cm and Dilator, guidewire 0.9x450mm, Introducers 1.4x70mm, stopcock, SHEATH INTRO POP KIT 7FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
5 00886333601486 680148 680148 Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve O Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.02mm x ID 2.28mm x 10cm and Dilator, guidewire 0.9x450mm, Introducers 1.7x70mm,1.4x70mm, stopcock, syringe, scalpel. SHEATH INTRO LINK KIT 7FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
6 00886333601400 680140 680140 Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.02mm x ID 2.28mm x 10cm and Dilator; Guidewire 0.9 x 450mm; Introducers 1.7 x 70mm 1.4 x 70mm; Contamination Shield; Stopcock; Syringe; Scalpel. SHEATH INTRO TRAY KIT 7FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
7 00886333601387 680138 680138 Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.70mm x ID 2.90mm x 10cm and Dilator; Guidewire 0.9 x 450mm; Introducers 1.7 x 70mm 1.4 x 70mm; Stopcock; Syringe; Scalpel. SHEATH INTRO LINK KIT 9FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
8 00886333601363 680136 680136 Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.70mm x ID 2.90mm x 10cm and Dilator; Guidewire 0.9 x 450mm; Introducers 1.7 x 70mm 1.4 x 70mm; Contamination Shield; Stopcock; Syringe; Scalpel. SHEATH INTRO KIT 9FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
9 00886333601349 680134 680134 Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.53mm x ID 2.74mm x 10cm and Dilator; Guidewire 0.9 x 450mm; Introducers 1.4 x 70mm; Stopcock SHEATH INTRO POP KIT 8.5FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
10 00886333601325 680132 680132 Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.53mm x ID 2.74mm x 10cm and Dilator; Guidewire 0.9 x 450mm; Introducers 1.7 x 70mm 1.4 x 70mm; Stopcock; Syringe; Scalpel. SHEATH INTRO LINK KIT 8.5FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
11 00886333601301 680130 680130 Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD Kits contents: Precutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.35mm x ID 2.51mm x 10cm and Dilator; Guidewire 0.9 x 450mm; Introducer 1.4 x 70mm; Stopcock SHEATH INTRO POP KIT 8FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
12 00886333601288 680128 680128 Catheter 6FR, Percutaneous Sheath Introducer with Sideport Haemostasiss Valve OD Catheter 6FR, Percutaneous Sheath Introducer with Sideport Haemostasiss Valve OD 2.76mm x ID 1.90mm x 10cm and Dilator, guidewire 0.9x450mm, introducers 1.7x70mm 1.4x70mm, contamination shield, stopcock, syringe and scalpel. SHEATH INTRO KIT 6FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
13 00886333601264 680126 680126 Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve O Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.35mm x ID 2.51mmx 10cm and Dilator, guidewire 0.9x450mm, Introducers 1.7x70mm,1.4x70mm, Contamination Shield, stopcock, syringe, scalpel. SHEATH INTRO KIT 8FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
14 00886333601240 680124 680124 Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve O Kits Contents : Percutaneous Sheath Introducer with Sideport Haemostasis Valve OD 3.53mm x ID 2.74mm x 10cm and Dilator, guidewire 0.9x450mm, Introducers 1.7x70mm,1.4x70mm, Contamination Shield, stopcock, syringe, scalpel. SHEATH INTRO 8.5FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
15 00886333601226 680122 680122 Catheter 6FR, Percutaneous Sheath Introducer with Sideport Haemostasiss Valve OD Catheter 6FR, Percutaneous Sheath Introducer with Sideport Haemostasiss Valve OD 2.76mm x ID 1.90mm, guidewire 0.9x450mm, introducer 1.4x70mm and stopcock. SHEATH INTRO POP KIT 6FR L5 MULT=5/50 ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
16 00886333225729 TPS006 TPS006 Scorpion®X - Portal Vein Access Set Scorpion ARGON MEDICAL DEVICES, INC.
17 00886333225552 TPS005 TPS005 Scorpion® - Portal Vein Access Set Scorpion ARGON MEDICAL DEVICES, INC.
18 00886333224647 TPS003 TPS003 Traveler™16 (16ga Needle Portal Vein Access Set) Traveler ARGON MEDICAL DEVICES, INC.
19 00886333224630 TPS002 TPS002 Traveler™21 (21ga Needle Portal Vein Access Set) Traveler ARGON MEDICAL DEVICES, INC.
20 00886333224623 TPS001 TPS001 Traveler™38 (0.038" Stylet Portal Vein Access Set) Traveler ARGON MEDICAL DEVICES, INC.
21 00886333218554 TL-19N TL-19N TLAB Transjugular Liver Biopsy System TLAB Transjugular Liver Biopsy System ARGON MEDICAL DEVICES, INC.
22 00886333218547 TL-19S TL-19S TLAB Transjugular Liver Biopsy System TLAB Transjugular Liver Biopsy System ARGON MEDICAL DEVICES, INC.
23 00886333218530 TL-18N TL-18N TLAB Transjugular Liver Biopsy System TLAB Transjugular Liver Biopsy System ARGON MEDICAL DEVICES, INC.
24 00886333218523 TL-18S TL-18S TLAB Transjugular Liver Biopsy System TLAB Transjugular Liver Biopsy System ARGON MEDICAL DEVICES, INC.
25 00886333218516 TL-19 TL-19 TLAB Transjugular Liver Access Biopsy System TLAB Transjugular Liver Access Biopsy System ARGON MEDICAL DEVICES, INC.
26 00886333218509 TL-18C TL-18C TLAB Transjugular Liver Biopsy System TLAB Transjugular Liver Biopsy System ARGON MEDICAL DEVICES, INC.
27 00886333217717 384062 384062 FirstStic™ Needle Introducer 26ga (1.9F) FirstStic™ Needle Introducer ARGON MEDICAL DEVICES, INC.
28 00886333213061 490029 490029 Long Sheath Introducer 9F Long Sheath Introducer ARGON MEDICAL DEVICES, INC.
29 00886333213047 490009 490009 Long Sheath Introducer 9F Long Sheath Introducer ARGON MEDICAL DEVICES, INC.
30 00886333213030 490008 490008 Long Sheath Introducer 8F Long Sheath Introducer ARGON MEDICAL DEVICES, INC.
31 00886333210503 392404 392404 Obturator 5F x 6.4" (16.2cm) Obturator ARGON MEDICAL DEVICES, INC.
32 00886333210497 392403 392403 Obturator 7F x 6.4" (16.2cm) Obturator ARGON MEDICAL DEVICES, INC.
33 00886333007059 391704400E 391704400E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
34 00886333007042 391705400E 391705400E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
35 00886333004331 391605500E 391605500E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
36 00886333004324 391605400E 391605400E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
37 00886333004317 391605000E 391605000E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
38 00886333004300 391604500E 391604500E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
39 00886333004294 391604400E 391604400E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
40 00886333004287 391604300E 391604300E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
41 00886333004270 391604000E 391604000E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
42 00886333004263 391605300E 391605300E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
43 00886333004256 391505500E 391505500E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
44 00886333004249 391505400E 391505400E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
45 00886333004232 391505300E 391505300E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
46 00886333004225 391505000E 391505000E V•Stick™ Vascular Access Set 5F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
47 00886333004218 391504500E 391504500E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
48 00886333004201 391504400E 391504400E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
49 00886333004195 391504300E 391504300E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.
50 00886333004188 391504000E 391504000E V•Stick™ Vascular Access Set 4F V•Stick™ Vascular Access Set ARGON MEDICAL DEVICES, INC.