The vital signs monitor is intended to be used for monitoring, displaying, revie
The vital signs monitor is intended to be used for monitoring, displaying, reviewing, storing and alarming of multiple physiological parameters including temperature(TEMP), Pulse Oxygen Saturation(BLT-SpO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Carbon dioxide(CO2)
MWI
Monitor,Physiological,Patient(Without Arrhythmia Detection Or Alarms)
The Monitor is used to monitor patient’s physiological parameters such as ECG、Re
The Monitor is used to monitor patient’s physiological parameters such as ECG、Respiration Rate( RESP)、Oxygen Saturation (BLT-SpO2)、Non-invasive Blood Pressure (NIBP)、Invasive Blood Pressure( IBP)、Temperature (TEMP)、Carbon dioxide (CO2) 、Anesthetic Gas (AG )and Impedance Cardiograph (ICG) continuously
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The Monitor is used to monitor patient’s physiological parameters such as ECG、Re
The Monitor is used to monitor patient’s physiological parameters such as ECG、Respiration Rate( RESP)、Oxygen Saturation (BLT-SpO2)、Non-invasive Blood Pressure (NIBP)、Invasive Blood Pressure( IBP)、Temperature (TEMP)、Carbon dioxide (CO2) 、Anesthetic Gas (AG )and Impedance Cardiograph (ICG) continuously
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The Monitor is intended to be used for monitoring, displaying, reviewing, storin
The Monitor is intended to be used for monitoring, displaying, reviewing, storing and alarming of multiple physiological parameters including ECG, Heart Rate(HR), Respiration Rate(RESP), Temperature(TEMP), Pulse Oxygen Saturation(BLT-SpO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Invasive Blood Pressure( IBP) and Carbon dioxide(CO2) of adult, pediatric and neonatal patient.
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The Monitor is intended to be used for monitoring, displaying, reviewing, storin
The Monitor is intended to be used for monitoring, displaying, reviewing, storing and alarming of multiple physiological parameters including ECG, Heart Rate(HR), Respiration Rate(RESP), Temperature(TEMP), Oxygen Saturation(BLT-SpO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Carbon dioxide(CO2) of adult, pediatric and neonatal patient.
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The Monitor is intended to be used for monitoring, displaying, reviewing, storin
The Monitor is intended to be used for monitoring, displaying, reviewing, storing and alarming of multiple physiological parameters including ECG(3-lead, 5-lead, 12-lead selectable), arrhythmia detection, ST segment analysis, Heart Rate(HR), Respiration Rate(RESP), Temperature(TEMP), Pulse Oxygen Saturation(Masimo-SpO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Invasive Blood Pressure(IBP), Carbon dioxide(CO2), Anesthetic Gas(AG), Impedance Cardiograph(ICG), Cerebral State Index(CSI), Bispectral Index(BIS), Total Hemoglobin(SpHb), Carboxyhemoglobin(SpCO), and Methemoglobin(SpMet).
MWI
Monitor,Physiological,Patient(Without Arrhythmia Detection Or Alarms)
The Monitor is intended to be used for monitoring, displaying, reviewing, storin
The Monitor is intended to be used for monitoring, displaying, reviewing, storing and alarming of multiple physiological parameters including ECG(3-lead, 5-lead, 12-lead selectable), arrhythmia detection, ST segment analysis, HR, Respiration Rate(RESP), TEMP, Pulse Oxygen Saturation(BLT-SpO2), PR, NIBP, IBP, CO2, Anesthetic Gas(AG), Impedance Cardiograph(ICG), CSI, BIS, SpHb, SpCO, and SpMet
MWI
Monitor,Physiological,Patient(Without Arrhythmia Detection Or Alarms)
The monitor is indicated for spot checking of functional arterial SpO2(BLT-SpO2)
The monitor is indicated for spot checking of functional arterial SpO2(BLT-SpO2), and pulse rate of patient.
RScribe 12-Lead Multi-Channel Electrocardiograph - version 6, current software C
RScribe 12-Lead Multi-Channel Electrocardiograph - version 6, current software CD; WAM Wireless Acquisition Module; Adult and pediatric interpretation; Software kit; No power cord; No printer; Suction electrodes (6) and clamps (4); AHA 10 wire, 12-lead lead set with banana plugs; Standard connectivity-includes XML order and XML/PDF output (required for HL7 interfacing)
Connex Cardio WAM ECG acquisition module v2, without lead wires, for use with Co
Connex Cardio WAM ECG acquisition module v2, without lead wires, for use with Connex Cardio