Other products from "WALLAC OY"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 06438147009718 B117-100 B117-100 For use with the DELFIA® Platewash or the AutoDELFIA® automatic immunoassay system. PPM General Purpose Reagent 1 DELFIA Wash Concentrate
2 06438147367917 3309-002U 3309-002U For the quantitative determination of total galactose concentration in dried blo For the quantitative determination of total galactose concentration in dried blood.Note: Kit contains multiple packages. JIA Enzymatic Methods, Galactose 1 GSP Neonatal Total Galactose kit
3 06438147356829 3046-0010 3046-0010 NeoBase™ 2 Succinylacetone Assay Solution is intended for in vitro diagnostic us NeoBase™ 2 Succinylacetone Assay Solution is intended for in vitro diagnostic use with the NeoBase 2 Non-derivatized MSMS kit and the NeoBase2 Non-derivatized Assay Solutions to extract succinylacetone from blood samples dried on filter paper. NQL System, Test, Amino Acids, Free Carnitines And Acylcarnitines Tandem Mass Spectrometry 2 NeoBase 2 Succinylacetone Assay Solution
4 06438147356706 2024-0010 2024-0010 The chemagic 360-D is an automated laboratory instrument used in preanalytical p The chemagic 360-D is an automated laboratory instrument used in preanalytical preparation of samples through magnetic particle separation technology for use with in vitro diagnostic clinical sample concentrating kits. The instrument is intended for use by healthcare professionals such as laboratory personnel or physicians who are trained in molecular biology techniques. JJH Clinical Sample Concentrator 1 chemagic 360-D
5 06438147344406 B064-112-P2 B064-112-P2 Time-resolved fluoroimmunoassay for the quantitative determination of human Inhibin A. NDR Enzyme Immunoassay, Inhibin-A 1 AutoDELFIA Inhibin A kit Level Calibrators
6 06438147311859 3040-001U 3040-001U For the quantitative determination of amino acid, acylcarnitine and free carniti For the quantitative determination of amino acid, acylcarnitine and free carnitine concentrations in dried blood. NQL System, Test, Amino Acids, Free Carnitines And Acylcarnitines Tandem Mass Spectrometry 2 NeoBase Non-derivatized MSMS kit
7 06438147299645 3304-0010 3304-0010 For the quantitative determination of europium (Eu³⁺) in dissociation-enhanced t For the quantitative determination of europium (Eu³⁺) in dissociation-enhanced time-resolved fluoroimmunoassays. PPM General Purpose Reagent 1 DELFIA Inducer
8 06438147295692 3041-0020 3041-0020 This reagent package is intended for sample processing in the assay of in vitro This reagent package is intended for sample processing in the assay of in vitro measurement and evaluation of the concentrations of amino acids, succinylacetone and acylcarnitines in dried blood spot samples (DBS) on filter paper.This reagent package is used together with the NeoBase Non-derivatized MSMS Kit and the NeoBase Succinylacetone Assay Solution. NQL System, Test, Amino Acids, Free Carnitines And Acylcarnitines Tandem Mass Spectrometry 2 NeoBase Non-derivatized Assay Solutions
9 06438147291359 3018-001B 3018-001B For the semi-quantitative determination of biotinidase in dried blood. Note: Kit For the semi-quantitative determination of biotinidase in dried blood. Note: Kit contains multiple packages. NAK System,Test,Biotinidase 2 Neonatal Biotinidase kit
10 06438147291342 3018-0010 3018-0010 For the semi-quantitative determination of biotinidase in dried blood. Note: Kit For the semi-quantitative determination of biotinidase in dried blood. Note: Kit contains multiple packages. NAK System,Test,Biotinidase 2 Neonatal Biotinidase kit
11 06438147246137 3025-0010 3025-0010 For in vitro use with the RESOLVE Hemoglobin Kits for isoelectric focusing. GKA Abnormal Hemoglobin Quantitation 2 RESOLVE Systems Hb Elution Solution
12 06438147246120 3024-0010 3024-0010 For in vitro use with the RESOLVE Hemoglobin Kits for isoelectric focusing. GKA Abnormal Hemoglobin Quantitation 2 RESOLVE Systems Hb Elution Solution
13 06438147149865 4010-0010 4010-0010 For use with the DELFIA® Platewash after dilution with deionized water. PPM General Purpose Reagent 1 DELFIA Wash Concentrate
14 06438147064564 1296-026 1296-026 1296-026 DELFIA Platewash is a washer designed for automatic washing of microtit 1296-026 DELFIA Platewash is a washer designed for automatic washing of microtitration strips or plates. It is self-contained, having built-in pumps for vacuum and dispensing and supplied with all the bottles and tubing needed for operation. For use with DELFIA analytes, ready-made programs are accessible. LXG Equipment, Laboratory, General Purpose, Labeled Or Promoted For A Specific Medical Use 1 DELFIA Platewash
15 06438147013890 1296-071 1296-071 Wallac 1296-071 DBS Puncher is a microprocessor controlled automatic puncher for Wallac 1296-071 DBS Puncher is a microprocessor controlled automatic puncher for DELFIA® tests performed on filter paper in microplate format. It punches out a disk from a bloodspot on filter paper; this disk then falls into a microtitration well. Punch disk size depends on the punch head installed. Up to 99 disks can be punched into the same well. When the selected number of disks has been punched for a well, the plate is moved to the next position so that the next disk(s) can be punched out. Up to two plates can be loaded to DBS puncher. A microtitration 96-well format plate and Corning Costar deep well tray can be loaded at the same time. Plates consisting of twelve eight-well strips are also supported. LXG Equipment, Laboratory, General Purpose, Labeled Or Promoted For A Specific Medical Use 1 Wallac DBS Puncher
16 06438147009336 B007-101 B007-101 Time-resolved fluoroimmunoassay for the quantitative determination of human chor Time-resolved fluoroimmunoassay for the quantitative determination of human chorionic gonadotropin (hCG). JHJ Agglutination Method, Human Chorionic Gonadotropin 2 AutoDELFIA hCG kit
17 06438147009206 A031-101 A031-101 Time-resolved fluoroimmunoassay for the quantitative determination of human lute Time-resolved fluoroimmunoassay for the quantitative determination of human luteinizing hormone (hLH). CEP Radioimmunoassay, Luteinizing Hormone 1 DELFIA hLH Spec kit
18 06438147009176 A007-101 A007-101 Time-resolved fluoroimmunoassay for the quantitative determination of human chor Time-resolved fluoroimmunoassay for the quantitative determination of human chorionic gonadotropin (hCG). JHJ Agglutination Method, Human Chorionic Gonadotropin 2 DELFIA hCG kit
19 06438147005291 1244-114 1244-114 For use with the DELFIA® Platewash or the AutoDELFIA® automatic immunoassay system. PPM General Purpose Reagent 1 DELFIA Wash Concentrate
20 06438147312009 3301-001U 3301-001U For the quantitative determination of human thyrotropin (thyroid stimulating hor For the quantitative determination of human thyrotropin (thyroid stimulating hormone - hTSH) in dried blood. JLW Radioimmunoassay, Thyroid-Stimulating Hormone 2 GSP Neonatal hTSH kit
21 06438147312139 3302-001U 3302-001U For the quantitative determination of thyroxine (T4) in dried blood. KLI Enzyme Immunoassay, Non-Radiolabeled, Total Thyroxine 2 GSP Neonatal Thyroxine (T4) kit
22 06438147295708 3042-0020 3042-0020 The NeoBase™ Succinylacetone Assay Solution is intended for in vitro diagnostic The NeoBase™ Succinylacetone Assay Solution is intended for in vitro diagnostic use with the NeoBase Non-derivatized MSMS Kit and the NeoBase non-derivatized Assay Solutions. The NeoBase™ Succinylacetone Assay Solution is used for the measurement and evaluation of succinylacetone concentration from blood samples dried on filter paper (DBS). NQL System, Test, Amino Acids, Free Carnitines And Acylcarnitines Tandem Mass Spectrometry 2 NeoBase Succinylacetone Assay Solution
23 06438147153312 5002-0180 5002-0180 Specimen Gate® Laboratory is a modular laboratory information management system Specimen Gate® Laboratory is a modular laboratory information management system intended for use as a calculator/data processing software for the storage, retrieval, and processing of laboratory data in newborn screening laboratories. JQP Calculator/Data Processing Module, For Clinical Use 1 Specimen Gate Laboratory
24 06438147009183 A017-201 A017-201 Time-resolved fluoroimmunoassay for the quantitative determination of human foll Time-resolved fluoroimmunoassay for the quantitative determination of human follicle stimulating hormone (hFSH). CGJ Radioimmunoassay, Follicle-Stimulating Hormone 1 DELFIA hFSH kit
25 06438147335022 1235-5220 1235-5220 The AutoDELFIA® system (Sample Processor and Plate Processor) is intended to be The AutoDELFIA® system (Sample Processor and Plate Processor) is intended to be used as an aid in screening with associated AutoDELFIA® reagent kits for neonatal screening and prenatal screening. It is an automatic immunoassay system designed to automatically perform assays using the proven and widely used method of time-resolved fluorometry. It is intended for in vitro quantitative determination of analytes as described by the associated assays. The function, specific disorder, condition or risk factor to be identified, the specimen type, and testing population are based on and described within the intended purpose of the applicable assay. The AutoDELFIA® system is intended to be used by trained laboratory personnel. KHO Fluorometer, For Clinical Use 1 AutoDELFIA Automatic Immunoassay System
26 06438147335008 1235-5110 1235-5110 The AutoDELFIA® system (Sample Processor and Plate Processor) is intended to be The AutoDELFIA® system (Sample Processor and Plate Processor) is intended to be used as an aid in screening with associated AutoDELFIA® reagent kits for neonatal screening and prenatal screening. It is an automatic immunoassay system designed to automatically perform assays using the proven and widely used method of time-resolved fluorometry. It is intended for in vitro quantitative determination of analytes as described by the associated assays. The function, specific disorder, condition or risk factor to be identified, the specimen type, and testing population are based on and described within the intended purpose of the applicable assay. The AutoDELFIA® system is intended to be used by trained laboratory personnel. KHO Fluorometer, For Clinical Use 1 AutoDELFIA Automatic Immunoassay System
27 06438147009343 B007-112 B007-112 Time-resolved fluoroimmunoassay for the quantitative determination of human chor Time-resolved fluoroimmunoassay for the quantitative determination of human chorionic gonadotropin (hCG). JHJ Agglutination Method, Human Chorionic Gonadotropin 2 AutoDELFIA hCG kit
28 06438147000814 FR-9400 FR-9400 For detection of normal and variant hemoglobins. GKA Abnormal Hemoglobin Quantitation 2 RESOLVE Systems Neonatal Hemoglobin Kit
29 06438147000791 FR-9360 FR-9360 For detection of normal and variant hemoglobins. GKA Abnormal Hemoglobin Quantitation 2 RESOLVE Systems Neonatal Hemoglobin Kit
30 06438147362615 3311-001U 3311-001U For the quantitative determination of Creatine Kinase -MM (CK-MM) concentration For the quantitative determination of Creatine Kinase -MM (CK-MM) concentration in dried blood.Note: Kit contains multiple packages. QJE Muscular Dystrophy Newborn Screening Test 2 GSP Neonatal Creatine Kinase -MM kit
31 06438147344208 3207-0010 3207-0010 For DNA extraction from human plasma or blood. JJH Clinical Sample Concentrator 1 chemagic DNA CS200 Kit
32 06438147321704 3303-001U 3303-001U For the quantitative determination of GALT (galactose-1-phosphate uridyl transfe For the quantitative determination of GALT (galactose-1-phosphate uridyl transferase) activity in dried blood. Note: Kit contains multiple packages. KQP Fluorescent Proc. (Qual.), Galactose-1-Phosphate Uridyl Transferase 2 GSP Neonatal GALT kit
33 06438147320523 3306-001U 3306-001U For the quantitative determination of immunoreactive trypsin (IRT) in dried blood. JNO N-Benzoyl-L-Arginine Ethyl Ester (U.V.), Trypsin 1 GSP Neonatal IRT kit
34 06438147311040 2021-0010 2021-0010 The GSP® instrument is a fully automated, high throughput batch analyzer for tim The GSP® instrument is a fully automated, high throughput batch analyzer for time-resolved and prompt fluorescence analysis of samples in microtitration plates. It is intended for in vitro quantitative / qualitative determination of analytes in body fluids. The GSP instrument and GSP chemistries are for professional use only. KHO Fluorometer, For Clinical Use 1 Genetic Screening Processor
35 06438147292523 B024-104 B024-104 For the quantitative determination of 17α-OH-progesterone (17-OHP) in dried blood. JLX Radioimmunoassay, 17-Hydroxyprogesterone 1 AutoDELFIA Neonatal 17α-OH-progesterone kit
36 06438147292486 B024-112 B024-112 For the quantitative determination of 17α-OH-progesterone (17-OHP) in dried blood. JLX Radioimmunoassay, 17-Hydroxyprogesterone 1 AutoDELFIA Neonatal 17α-OH-progesterone kit
37 06438147292479 B024-01C B024-01C For the quantitative determination of 17α-OH-progesterone (17-OHP) in dried blood. JLX Radioimmunoassay, 17-Hydroxyprogesterone 1 AutoDELFIA Neonatal 17α-OH-progesterone kit
38 06438147119158 B138-100 B138-100 For use with the AutoDELFIA® and the DELFIA® kits for sample dilution. PPM General Purpose Reagent 1 DELFIA Diluent II
39 06438147244898 4022-0010 4022-0010 For use with the AutoDELFIA® and the DELFIA® kits for sample dilution. PPM General Purpose Reagent 1 DELFIA Diluent 3
40 06438147244881 4021-0010 4021-0010 For use with the AutoDELFIA® and the DELFIA® kits for sample dilution. PPM General Purpose Reagent 1 DELFIA Diluent 3
41 06438147140466 A032-310 A032-310 Time-resolved fluoroimmunoassay for the quantitative determination of human thyr Time-resolved fluoroimmunoassay for the quantitative determination of human thyrotropin (thyroid stimulating hormone - hTSH) in dried blood. JLW Radioimmunoassay, Thyroid-Stimulating Hormone 2 DELFIA Neonatal hTSH kit
42 06438147009770 B132-100 B132-100 For use with the AutoDELFIA® and the DELFIA® kits for sample dilution. PPM General Purpose Reagent 1 DELFIA Diluent II
43 06438147009763 B131-100 B131-100 For use with the AutoDELFIA® and the DELFIA® kits for sample dilution. PPM General Purpose Reagent 1 DELFIA Diluent II
44 06438147001279 NG-4100 NG-4100 For the quantitative determination of GALT (galactose-1-phosphate uridyl transfe For the quantitative determination of GALT (galactose-1-phosphate uridyl transferase) in dried blood. Note: Kit contains multiple packages. KQP Fluorescent Proc. (Qual.), Galactose-1-Phosphate Uridyl Transferase 2 Neonatal GALT kit
45 06438147001262 NG-1100 NG-1100 For the quantitative determination of GALT (galactose-1-phosphate uridyl transfe For the quantitative determination of GALT (galactose-1-phosphate uridyl transferase) in dried blood. Note: Kit contains multiple packages. KQP Fluorescent Proc. (Qual.), Galactose-1-Phosphate Uridyl Transferase 2 Neonatal GALT kit
46 06438147356218 3093-001U 3093-001U For the quantitative measurement of the activity of certain lysosomal enzymes in For the quantitative measurement of the activity of certain lysosomal enzymes in dried blood spots.Note: Kit contains multiple packages. PQW Alpha-D-Galactosidase A (Gla) Newborn Screening Test System 2 NeoLSD MSMS kit
47 06438147355037 B095-112 B095-112 Time-resolved fluoroimmunoassay for the quantitative determination of unconjugat Time-resolved fluoroimmunoassay for the quantitative determination of unconjugated estriol (uE3). CGI Radioimmunoassay, Estriol 1 AutoDELFIA Unconjugated Estriol (uE3) kit
48 06438147355013 B095-101U B095-101U Time-resolved fluoroimmunoassay for the quantitative determination of unconjugat Time-resolved fluoroimmunoassay for the quantitative determination of unconjugated estriol (uE3). CGI Radioimmunoassay, Estriol 1 AutoDELFIA Unconjugated Estriol (uE3) kit
49 06438147352401 5002-0540 5002-0540 The MSMS Workstation is intended for use as a calculator/data processing softwar The MSMS Workstation is intended for use as a calculator/data processing software for the storage, retrieval, and processing of mass spectrometry data. JQP Calculator/Data Processing Module, For Clinical Use 1 MSMS Workstation
50 06438147119745 B083-C01 B083-C01 Time-resolved fluoroimmunoassay for the quantitative determination of unconjugat Time-resolved fluoroimmunoassay for the quantitative determination of unconjugated estriol (uE3). CGI Radioimmunoassay, Estriol 1 AutoDELFIA Unconjugated Estriol (uE3) kit
Other products with the same Product Code "JQP"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 07640172343012 PTB ProTube is designed to automate biological sample collection process. ProTube en ProTube is designed to automate biological sample collection process. ProTube ensures the biological sample collection phase is carried out safely and in a traceable way. ProTube is designed to support positive patient identification, order review, automatic tube recognition, automatic tube labelling, production of single labels for biological sample containers, sample check-out and monitoring of transport parameters. ProTube INPECO SA
2 07640172343005 PTB The ProTube System is designed to automate biological sample collection process. The ProTube System is designed to automate biological sample collection process. ProTube ensures the biological sample collection phase is carried out safely and in a traceable way. The ProTube System is designed to support positive patient identification, order review, automatic tube recognition, automatic tube labelling, production of single labels for biological sample containers and sample check-out. ProTube INPECO SA
3 07613336177129 09180443001 09180443001 cobas® infinity central lab ROCHE DIAGNOSTICS GMBH
4 07613336164846 08763640001 08763640001 cobas pro B-Gate update Kit ROCHE DIAGNOSTICS GMBH
5 07613336164280 08739170001 08739170001 cobas infinity POC IT solutions ROCHE DIAGNOSTICS GMBH
6 07613336157046 08420254001 08420254001 cobas infinity POC remote access ROCHE DIAGNOSTICS GMBH
7 07613336156520 08368449001 08368449001 BCM for cobas 8100 ROCHE DIAGNOSTICS GMBH
8 07613327568998 0794111090 0794-111-090 QBL Software License N/A STRYKER CORPORATION
9 07613327568981 0694-002-100 0694-002-100 + EMR/QBL APPLICATION SURGICOUNT STRYKER CORPORATION
10 07311091391681 139168 139168 HemoCue® 801 Connect HemoCue® 801 Connect HEMOCUE AB
11 06438147352401 5002-0540 5002-0540 The MSMS Workstation is intended for use as a calculator/data processing softwar The MSMS Workstation is intended for use as a calculator/data processing software for the storage, retrieval, and processing of mass spectrometry data. MSMS Workstation WALLAC OY
12 06438147320905 5002-0500 5002-0500 Specimen Gate® Screening Center™ is intended to be used for data management of n Specimen Gate® Screening Center™ is intended to be used for data management of neonatal screening test results and demographics by qualified laboratory personnel in newborn screening programs. Screening Center WALLAC OY
13 06438147153312 5002-0180 5002-0180 Specimen Gate® Laboratory is a modular laboratory information management system Specimen Gate® Laboratory is a modular laboratory information management system intended for use as a calculator/data processing software for the storage, retrieval, and processing of laboratory data in newborn screening laboratories. Specimen Gate Laboratory WALLAC OY
14 06438147153275 5002-0130 5002-0130 Specimen Gate® PatientCare™ is intended for management of the follow-up workflow Specimen Gate® PatientCare™ is intended for management of the follow-up workflow of a screening system. PatientCare WALLAC OY
15 05700574037314 K5810AA Bench LAB CNV Bench Lab CNV AGILENT TECHNOLOGIES BELGIUM
16 05700574035631 K5849AA Alissa Interpret Alissa Interpret AGILENT TECHNOLOGIES BELGIUM
17 05415062388310 CI4054279 Software to identify heart failure patients who may be at risk of having wtATTR-CM wtATTR-CM AcceleraTTR™ PFIZER INC.
18 04048534002011 0760-0101 0760-0101 EKF Link is a data and device management system that enables healthcare professi EKF Link is a data and device management system that enables healthcare professionals to transfer, manage, store and display measurement results from point -of-care diagnostic testing analyzers. EKF Link enables the allocation of additional information to measurement results and facilitates the export or transfer of data for documentation purposes.EKF Link is intended to be used as an optional software application with EKF point -of-care analyzers and open to be interfaced to other vendor’s point-of-care testing analyzers verified for connection with EKF Link.EKF Link facilitates the setting of configurable options of connected analyzers. EKF Link EKF-DIAGNOSTIC GMBH
19 04015630942305 06884750001 06884750001 B-Gate Interface ROCHE DIAGNOSTICS GMBH
20 04015630936007 07154003001 07154003001 cobas&#x00AE infinity central lab ROCHE DIAGNOSTICS GMBH
21 04015630929078 05349966001 05349966001 cobas p 701 Post-Analytical Unit ROCHE DIAGNOSTICS GMBH
22 04015630929061 05158494001 05158494001 cobas p 501 post-analytical unit ROCHE DIAGNOSTICS GMBH
23 04015630035342 04420306001 04420306001 cobas IT 1000 ROCHE DIAGNOSTICS GMBH
24 03770027519041 TD-Web TD-Web is a web solution to easily manage orders creation, optimize collection TD-Web is a web solution to easily manage orders creation, optimize collection management and provide real-time results access at the patient’s bedside. TD-Web TECHNIDATA
25 03770027519034 TDWorkstation TDWorkstation is a powerful software designed to interface instruments with any TDWorkstation is a powerful software designed to interface instruments with any Laboratory Information System (LIS) and manage results with efficiency and flexibility. TDWorkstation TECHNIDATA
26 03770027519010 TDHisto/Cyto TDHisto/Cyto is a software used for managing medical information in the field TDHisto/Cyto is a software used for managing medical information in the field of laboratories performing histology, non-gynecological and gynecological cytology and autopsy activities.. TDHisto/Cyto TECHNIDATA
27 03770027519003 TDNexLabs TDNexLabs is a Laboratory Information System (LIS) (software product) intended t TDNexLabs is a Laboratory Information System (LIS) (software product) intended to be used for the management of clinical information.TDNexLabs is intended to be used only by health professionals. TDNexLabs TECHNIDATA
28 00883489001450 GP200 Rightest BIONIME CORPORATION
29 00883489000873 GP200 GE BIONIME CORPORATION
30 00862696000289 0 a calculator/data processing module for clinical use described as electronic dev a calculator/data processing module for clinical use described as electronic device intended to store, retrieve, and process laboratory data. BG Analytics Software ASSOCIATES OF CAPE COD, INC.
31 00859519002247 DMS The Telserve® Data Management System is an accessory to blood glucose monitoring The Telserve® Data Management System is an accessory to blood glucose monitoring systems for the review and evaluation of blood glucose test results to aid in diabetes management. Telserve® Data Management System TELCARE, LLC
32 00859474006397 1.0.6.2 SoftTotalQC SCC SOFT COMPUTER
33 00859474006861 3.5.52.0 SoftMolecular SCC SOFT COMPUTER
34 00859474006854 3.5.52.0 SoftHLA SCC SOFT COMPUTER
35 00859474006847 3.5.52.0 SoftFlowCytometry SCC SOFT COMPUTER
36 00859474006830 3.5.52.0 SoftPathDx SCC SOFT COMPUTER
37 00859474006823 3.5.52.0 SoftCytogenetics SCC SOFT COMPUTER
38 00859474006816 3.5.52.0 SoftBiochemistry SCC SOFT COMPUTER
39 00859474006632 4.5.5.51 SoftLab SCC SOFT COMPUTER
40 00859474006625 4.5.5.51 SoftMic SCC SOFT COMPUTER
41 00859474006618 4.5.5.51 SoftROE SCC SOFT COMPUTER
42 00859474006595 4.5.7.3 SoftMic SCC SOFT COMPUTER
43 00859474006588 4.5.7.3 SoftLab SCC SOFT COMPUTER
44 00859474006571 4.5.7.3 SoftROE SCC SOFT COMPUTER
45 00859474006564 4.5.8.0 SoftROE SCC SOFT COMPUTER
46 00859474006557 4.0.8.4 SoftROE SCC SOFT COMPUTER
47 00859474006540 2.0.4.0 SoftWebPlus SCC SOFT COMPUTER
48 00859474006533 1.1.1.4 SoftWebPlus SCC SOFT COMPUTER
49 00859474006519 4.5.8.0 SoftMic SCC SOFT COMPUTER
50 00859474006502 4.5.8.0 SoftLab SCC SOFT COMPUTER