The Icare ic200 (TA031) tonometer is a hand-held, battery operated device, which
The Icare ic200 (TA031) tonometer is a hand-held, battery operated device, which measures intraocular pressure (IOP) without the need for topical anesthesia. The Icare ic200 tonometer measures the IOP by utilizing the rebound method. The Icare ic200 tonometer is intended to be used for the measurement of intraocular pressure of the human eye. Icare ic200 allows IOP measurement of patients in all positions between sitting and supine positions. IOP measurement result can be transferred to printer or to a PC via Bluetooth connection.
The Icare tonometer is used in the diagnosis, follow up and screening of glaucom
The Icare tonometer is used in the diagnosis, follow up and screening of glaucoma. It is based on induction-based rebound method, which allows intraocular pressure (IOP) to be measured accurately, rapidly and without an anesthetic.The Icare tonometer TA01i is intended to be used for the measurement of intraocular pressure of the human eye.
Schiotz tonometer with inclined scale, manufactured and certified by Gulden Opht
Schiotz tonometer with inclined scale, manufactured and certified by Gulden Ophthalmic, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights
Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when o
Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when ordering this replacement part, service charge included in price listed
Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured
Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured and certified by Gulden Ophthalmics, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights
Manual tonometer used to gauge internal pressure within the eye. An allen wrench
Manual tonometer used to gauge internal pressure within the eye. An allen wrench can be used to adjust weight settings.
Manual Tonometer is used to gauge the internal pressure of the eye using weights
Manual Tonometer is used to gauge the internal pressure of the eye using weights and a tonometer tip.
The Non-Contact Tonometer is intended to be used to measure the intraocular pres
The Non-Contact Tonometer is intended to be used to measure the intraocular pressure of the human eye.
The Non-Contact Tonometer is intended to be used to measure the intraocular pres
The Non-Contact Tonometer is intended to be used to measure the intraocular pressure of the human eye.
It is a manual device intended for measurement of intraocular pressure by applan
It is a manual device intended for measurement of intraocular pressure by applanation (applying a small flat disk to the cornea) to aid the diagnosis of glaucoma
It is a manual device intended for measurement of intraocular pressure by applan
It is a manual device intended for measurement of intraocular pressure by applanation (applying a small flat disk to the cornea) to aid the diagnosis of glaucoma
It is a manual device intended for measurement of intraocular pressure by applan
It is a manual device intended for measurement of intraocular pressure by applanation (applying a small flat disk to the cornea) to aid the diagnosis of glaucoma