Other products from "INTERACOUSTICS A/S"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 05711117180213 AD226 EWO Audiometer 2 Interacoustics
2 05711117101621 AD629 EWO Audiometer 2 Interacoustics
3 05711117070736 Affinity 2.0 ETW,EWO Calibrator, Hearing Aid / Earphone And Analysis Systems,Audiometer 2 Interacoustics
4 05711117180329 AA222 ETY Tester, Auditory Impedance 2 Interacoustics
5 05711117223583 VisualEyes EyeSeeCam vHIT GWN Nystagmograph 2 Interacoustics
6 05711117223576 Orion Autotraverse Basic GWN Nystagmograph 2 Interacoustics
7 05711117223569 Orion Comprehensive Basic GWN Nystagmograph 2 Interacoustics
8 05711117223552 VisualEyes 525 GWN Nystagmograph 2 Interacoustics
9 05711117223545 VisualEyes 515 GWN Nystagmograph 2 Interacoustics
10 05711117180565 EyeSeeCam GWN Nystagmograph 2 Interacoustics
11 05711117223538 VisualEyes 505 GWN Nystagmograph 2 Interacoustics
12 05711117223095 Luna EWO Audiometer 2 Interacoustics
13 05711117219098 TRV LXV Apparatus, Vestibular Analysis U Interacoustics
14 05711117199574 Aqua Stim ETP Stimulator, Caloric-Water 1 Interacoustics
15 05711117198218 Affinity Compact ETW,EWO Calibrator, Hearing Aid / Earphone And Analysis Systems,Audiometer 2 Interacoustics
16 05711117197877 AD528 Audiometer EWO Audiometer 2 Interacoustics
17 05711117196313 Lyra EWO Audiometer 2 Interacoustics
18 05711117195989 VisualEyes 505 GWN Nystagmograph 2 Interacoustics
19 05711117190823 Sera GWJ,EWO Stimulator, Auditory, Evoked Response,Audiometer 2 Interacoustics
20 05711117180558 VisualEyes 525 GWN Nystagmograph 2 Interacoustics
21 05711117180541 VisualEyes 515 GWN Nystagmograph 2 Interacoustics
22 05711117180497 2D-VOGfw GWN Nystagmograph 2 Interacoustics
23 05711117180459 OtoRead EWO Audiometer 2 Interacoustics
24 05711117180305 PA5 EWO Audiometer 2 Interacoustics
25 05711117180282 MT10 ETY Tester, Auditory Impedance 2 Interacoustics
26 05711117180268 Equinox 2.0 ETW,EWO Calibrator, Hearing Aid / Earphone And Analysis Systems,Audiometer 2 Interacoustics
27 05711117180251 AT235 ETY Tester, Auditory Impedance 2 Interacoustics
28 05711117180244 AS608 EWO Audiometer 2 Interacoustics
29 05711117180206 AC40 EWO Audiometer 2 Interacoustics
30 05711117089189 Callisto ETW,EWO Calibrator, Hearing Aid / Earphone And Analysis Systems,Audiometer 2 Interacoustics
31 05711117082104 Titan EWO,GWJ,ETY Audiometer,Stimulator, Auditory, Evoked Response,Tester, Auditory Impedance 2 Interacoustics
32 05711117076677 Eclipse GWJ,EWO Stimulator, Auditory, Evoked Response,Audiometer 2 Interacoustics
33 05711117221848 EARturtle ETT Cushion, Earphone (For Audiometric Testing) Sanibel Supply
34 05711117199369 Pre-wired electrode GXY Electrode, Cutaneous Sanibel
35 05711117199352 Snap electrode Pouch of 60 electrodes GXY Electrode, Cutaneous Sanibel
36 05711117199345 Tab electrode GXY Electrode, Cutaneous Sanibel
37 05711117199338 Snap electrode GXY Electrode, Cutaneous Sanibel
38 05711117199321 Snap electrode GXY Electrode, Cutaneous Sanibel
39 05711117180572 TM electrode GXY Electrode, Cutaneous 2 Sanibel
40 05711117129687 TAB Electrode Pouch with 100 electrodes (10 cards with 10 each) GXY Electrode, Cutaneous Sanibel
Other products with the same Product Code "KHH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 05713315009266 8-04-13330 AirCal Caloric Stimulator, Extended (Extended length - 4m) ICS GN OTOMETRICS A/S
2 05713315009259 8-04-13320 AirCal Caloric Stimulator, Extended (Extended length - 4m) ICS GN OTOMETRICS A/S
3 05713315009242 8-04-13301 AirCal Caloric Stimulator, Extended (Extended length - 4m) ICS GN OTOMETRICS A/S
4 05713315009235 8-04-13300 AirCal Caloric Stimulator (Standard length - 3m) ICS GN OTOMETRICS A/S
5 05713315004131 "AirCal Caloric Stimulator, Extended GN Otometrics A/S GN OTOMETRICS A/S
6 05713315004124 "AirCal Caloric Stimulator, Extended GN Otometrics A/S GN OTOMETRICS A/S
7 05713315002533 Specula, disposable GN Otometrics A/S GN OTOMETRICS A/S
8 05711117199567 Air Fx Interacoustics INTERACOUSTICS A/S
9 B516310130 AirStar 115V 31013 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements.The handle is equipped with an otoscope head where a disposable ear tips can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation.By default, temperature values are 27°C, 30°C, 44°C and 47°C.Five stimulation times are available: 40, 60, 80,100 and 120sWarm air caloric stimulatorMinimal temperature reachable: 5°C over the ambient temperatureMaximal temperature reachable: 48°CAir flow: fixed, from 10 to 13l/min, without ear tipTimerIntended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to thecaloric testing process. Instrumentation Difra SA INSTRUMENTATION DIFRA SA
10 B516310120 AirStar 230V 31012 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements.The handle is equipped with an otoscope head where a disposable ear tips can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation.By default, temperature values are 27°C, 30°C, 44°C and 47°C.Five stimulation times are available: 40, 60, 80,100 and 120sWarm air caloric stimulatorMinimal temperature reachable: 5°C over the ambient temperatureMaximal temperature reachable: 48°CAir flow: fixed, from 10 to 13l/min, without ear tipTimerIntended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to thecaloric testing process. Instrumentation Difra SA INSTRUMENTATION DIFRA SA
11 B516175530 CoolStar 115V 3.0 17553 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements. The handle is equipped with an otoscope head where a disposable ear tip can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation. CoolStar is ideal when water can not be used for stimulation , when water inlet and outlet are not available in the examination room and when ambient room temperature exceeds 22 C. Instrumentation Difra INSTRUMENTATION DIFRA SA
12 B51617553 CoolStar 115V 3.0 17553 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements.The handle is equipped with an otoscope head where a disposable ear tip can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation.CoolStar is ideal when water can not be used for stimulation (tympanic membrane perforation, …), when water inlet and outlet are not available in the examination room and when ambient room temperature exceeds 22°C.Cool and warm air caloric stimulatorMinimal temperature reachable: 10°C with water temperature in glass jar below 50°CMaximal temperature reachable: 49,8°CAir flow: fixed, from 8 to 10l/min, without ear tipTimer: Five stimulation times are available: 40, 60, 80,100 and 120sIntended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to the caloric testing process.Glass jar with connection for demineralized water, holder and connections Instrumentation Difra INSTRUMENTATION DIFRA SA
13 B516174850 AirStar 2.0 17485 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements.The handle is equipped with an otoscope head where a disposable ear tips can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation.By default, temperature values are 27°C, 30°C, 44°C and 47°C.Five stimulation times are available: 40, 60, 80,100 and 120sWarm air caloric stimulatorMinimal temperature reachable: 5°C over the ambient temperatureMaximal temperature reachable: 48°CAir flow: fixed, from 10 to 13l/min, without ear tipTimerIntended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to thecaloric testing process. Instrumentation Difra INSTRUMENTATION DIFRA SA
14 B51617485 AirStar 2.0 17485 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements.The handle is equipped with an otoscope head where a disposable ear tips can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation.By default, temperature values are 27°C, 30°C, 44°C and 47°C.Five stimulation times are available: 40, 60, 80,100 and 120sWarm air caloric stimulatorMinimal temperature reachable: 5°C over the ambient temperatureMaximal temperature reachable: 48°CAir flow: fixed, from 10 to 13l/min, without ear tipTimerIntended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to thecaloric testing process. Instrumentation Difra INSTRUMENTATION DIFRA SA
15 B516174810 CoolStar 230V 3.0 17481 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements. The handle is equipped with an otoscope head where a disposable ear tip can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation. CoolStar is ideal when water can not be used for stimulation , when water inlet and outlet are not available in the examination room and when ambient room temperature exceeds 22 C. Instrumentation Difra INSTRUMENTATION DIFRA SA
16 B51617481 CoolStar 230V 3.0 17481 The air caloric stimulator is a device that delivers a stream of air to the ear The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements.The handle is equipped with an otoscope head where a disposable ear tip can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation.CoolStar is ideal when water can not be used for stimulation (tympanic membrane perforation, …), when water inlet and outlet are not available in the examination room and when ambient room temperature exceeds 22°C.Cool and warm air caloric stimulatorMinimal temperature reachable: 10°C with water temperature in glass jar below 50°CMaximal temperature reachable: 49,8°CAir flow: fixed, from 8 to 10l/min, without ear tipTimer: Five stimulation times are available: 40, 60, 80,100 and 120sIntended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to the caloric testing process.Glass jar with connection for demineralized water, holder and connections Instrumentation Difra INSTRUMENTATION DIFRA SA