Other products from "ADVANCED SURGICAL CONCEPTS LIMITED"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 05391530440097 WA58015T This device is intended for use as an endoscopic instrument(s) and/or camera por This device is intended for use as an endoscopic instrument(s) and/or camera port during minimally invasive abdominal surgery.The ASC TriPort15 is a sterile, disposable endoscopic multi-instrument port. The device consists of the following:• An Introducer that allows the insertion of the Base Retractor into the abdomen through an incision.• A Base Retractor that retracts in an abdominal incision to allow laparoscopic instruments pass through to the abdomen. • A Boot contains three instrument valves and two ports that allow insufflation of the abdomen or venting of electrocautery gases. The Boot maintains pneumoperitoneum when attached and allows specimen removal when detached. OTJ Laparoscopic Single Port Access Device TriPort15
2 05391530440073 WA58010T This device is intended for use as an endoscopic instrument(s) and/or camera por This device is intended for use as an endoscopic instrument(s) and/or camera port during minimally invasive abdominal surgery.The ASC TriPort+ is a sterile, disposable endoscopic multi-instrument port. The device consists of the following:• An Introducer that allows the insertion of the Base Retractor into the abdomen through an incision.• A Base Retractor that retracts in an abdominal incision to allow laparoscopic instruments pass through to the abdomen. • A Boot contains four instrument valves and two ports that allow insufflation of the abdomen or venting of electrocautery gases. The Boot maintains pneumoperitoneum when attached and allows specimen removal when detached. OTJ,GCJ Laparoscopic Single Port Access Device,Laparoscope, General & Plastic Surgery 2 TriPort+
3 05391530440127 GAR-1 The Guardenia contained extraction system is indicated to contain and isolate ti The Guardenia contained extraction system is indicated to contain and isolate tissue during, or prior to, surgical removal and/or extracorporeal manual morcellation.A system for the containment of tissue for reduction, with a scalpel (or similar instrument), and extraction.The device will retract the incision & contain the tissue being extracted. The device will provide protection of the containment component from inadvertent damage from sharp instruments used in the reduction process. GCJ Laparoscope, General & Plastic Surgery 2 Guardenia
4 05391530440004 WA90500US The PneumoLiner device is intended for use as a multiple instrument port and tis The PneumoLiner device is intended for use as a multiple instrument port and tissue containment system during minimally invasive gynecologic laparoscopic surgery to enable the isolation and containment of tissue, considered benign, resected during single-port or multi-site laparoscopic surgery during power morcellation and removal. The PneumoLiner is compatible with bipolar or electromechanical laparoscopic power morcellators that are between 15mm and 18mm in shaft outer diameter and 135mm and 180mm in shaft working length and which have an external component that allows for the proper orientation of the laparoscope to perform a contained morcellation.The ASC PneumoLiner Device has two main components. It consists of:1. The PneumoLiner, a tissue pouch intended to provide a space within the abdomen for the safe morcellation of tissue; and2. A laparoscopic multi-instrument port.1. Multi-instrument PortThe laparoscopic multi-instrument port is comprised of the following three sub-components:The Retractor Introducer which delivers the Distal Ring of the Retractor through a premade incision, into the abdominal cavity.The Retractor which retracts an abdominal incision to allow the passage of laparoscopic instruments and provides an anchor for the Valve Component.The Boot Assembly which maintains the pneumoperitoneum established for the surgical procedure.2. PneumoLinerThe PneumoLiner, has two sub-components:An Introducer for delivery of the PneumoLiner.The PneumoLiner, that when under pneumoperitoneum provides a space for morcellation of the chosen tissue that can be visualized. PMU Containment System, Laparoscopic Power Morcellation, With Instrument Port 2 PneumoLiner
Other products with the same Product Code "OTJ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 08719324463201 Introducer Clamp Type C 314-104 The purpose of the symphonX™ Introducer Clamp is to fix / snug fit lock the symp The purpose of the symphonX™ Introducer Clamp is to fix / snug fit lock the symphonX™ Introducer to the trocar in axial direction during surgery. symphonX™ FORTIMEDIX SURGICAL B.V.
2 08719324463195 Introducer Clamp Type B 314-103 The purpose of the symphonX™ Introducer Clamp is to fix / snug fit lock the symp The purpose of the symphonX™ Introducer Clamp is to fix / snug fit lock the symphonX™ Introducer to the trocar in axial direction during surgery. symphonX™ FORTIMEDIX SURGICAL B.V.
3 08719324463188 Introducer Clamp Type A 314-102 The symphonX™ Introducer Clamp is to fix / snug fit lock the symphonX™ Introduce The symphonX™ Introducer Clamp is to fix / snug fit lock the symphonX™ Introducer to the trocar in axial direction during surgery. symphonX™ FORTIMEDIX SURGICAL B.V.
4 08719324463171 Hub Cap & Sealing Unit 314-201 Device for use in combination with the symphonX Introducer during minimally inva Device for use in combination with the symphonX Introducer during minimally invasive abdominal laparoscopic surgical procedures symphonX™ FORTIMEDIX SURGICAL B.V.
5 08719324463003 Introducer 314-101 The symphonX™ Introducer is intended to establish a path of entry for laparoscop The symphonX™ Introducer is intended to establish a path of entry for laparoscopic Instruments for use during minimally invasive abdominal laparoscopic surgery in combination with the symphonX™ (short) Instruments. symphonX™ FORTIMEDIX SURGICAL B.V.
6 05391530440110 WA58010Q This device is intended for use as a multiple instrument and/or camera port duri This device is intended for use as a multiple instrument and/or camera port during minimally invasive abdominal laparoscopic surgery.The ASC QuadPort+ is a sterile, disposable endoscopic multi-instrument port. The device consists of the following:• An Introducer that allows the insertion of the Base Retractor into the abdomen through an incision.• A Base Retractor that retracts in an abdominal incision to allow laparoscopic instruments pass through to the abdomen. • A Boot contains five instrument valves and two ports that allow insufflation of the abdomen or venting of electrocautery gases. The Boot maintains pneumoperitoneum when attached and allows specimen removal when detached. QuadPort+ ADVANCED SURGICAL CONCEPTS LIMITED
7 05391530440097 WA58015T This device is intended for use as an endoscopic instrument(s) and/or camera por This device is intended for use as an endoscopic instrument(s) and/or camera port during minimally invasive abdominal surgery.The ASC TriPort15 is a sterile, disposable endoscopic multi-instrument port. The device consists of the following:• An Introducer that allows the insertion of the Base Retractor into the abdomen through an incision.• A Base Retractor that retracts in an abdominal incision to allow laparoscopic instruments pass through to the abdomen. • A Boot contains three instrument valves and two ports that allow insufflation of the abdomen or venting of electrocautery gases. The Boot maintains pneumoperitoneum when attached and allows specimen removal when detached. TriPort15 ADVANCED SURGICAL CONCEPTS LIMITED
8 05391530440073 WA58010T This device is intended for use as an endoscopic instrument(s) and/or camera por This device is intended for use as an endoscopic instrument(s) and/or camera port during minimally invasive abdominal surgery.The ASC TriPort+ is a sterile, disposable endoscopic multi-instrument port. The device consists of the following:• An Introducer that allows the insertion of the Base Retractor into the abdomen through an incision.• A Base Retractor that retracts in an abdominal incision to allow laparoscopic instruments pass through to the abdomen. • A Boot contains four instrument valves and two ports that allow insufflation of the abdomen or venting of electrocautery gases. The Boot maintains pneumoperitoneum when attached and allows specimen removal when detached. TriPort+ ADVANCED SURGICAL CONCEPTS LIMITED
9 04055207021088 8850501 8850501 TWO-WAY TAP reusable NA RICHARD WOLF GMBH
10 04055207021071 8850243 8850243 SILICONE SEALING INSERT with three valve accesses, PACK=3 PCS, with connection SILICONE SEALING INSERT with three valve accesses, PACK=3 PCS, with connection for CO2 insufflation / smoke aspiration, reusable KEYPORT RICHARD WOLF GMBH
11 04055207021064 8850010 8850010 SLEEVE FOR SEALING CAP 8908 CAP 10MM reusable NA RICHARD WOLF GMBH
12 04055207021057 8850005 8850005 SLEEVE FOR SEALING CAP 89.02 CAP 5.8MM reusable NA RICHARD WOLF GMBH
13 04055207011386 885031 885031 TROCAR TIP DULL SZ 24MM with central channel for primary insufflation, for sing TROCAR TIP DULL SZ 24MM with central channel for primary insufflation, for single port trocar sleeve 885030, reusable KEYPORT RICHARD WOLF GMBH
14 04055207011379 885030 885030 TROCAR SLEEVE SINGLE PORT 35MM plastic sleeve with thread anchoring, wl 36mm, t TROCAR SLEEVE SINGLE PORT 35MM plastic sleeve with thread anchoring, wl 36mm, triangular shape, interface for mounting arm (EndoMotion mounting arm 37500.001 and U-shaped mounting arm 8840.9721) and fixation possible to fascia suture interface for silicone sealing insert, reusable KEYPORT RICHARD WOLF GMBH
15 04055207011362 885021 885021 TROCAR TIP DULL SZ 21MM distal tip rounded-dull, with central channel for prima TROCAR TIP DULL SZ 21MM distal tip rounded-dull, with central channel for primary insufflation, for single port trocar sleeve 885020, reusable KEYPORT RICHARD WOLF GMBH
16 04055207011355 885020 885020 TROCAR SLEEVE SINGLE PORT 31MM plastic sleeve with thread anchoring, wl 30mm, t TROCAR SLEEVE SINGLE PORT 31MM plastic sleeve with thread anchoring, wl 30mm, triangular shape, interface for mounting arm (EndoMotion mounting arm 37500.001 and U-shaped mounting arm 8840.9721) and fixation possible to fascia suture interface for silicone sealing insert, reusable KEYPORT RICHARD WOLF GMBH
17 04055207011348 885015 885015 ADAPTER FOR SEALING CAP 8931 CAP 15MM reusable NA RICHARD WOLF GMBH
18 04055207011331 885010 885010 ADAPTER FOR SEALING CAP 8908 CAP 10MM reusable NA RICHARD WOLF GMBH
19 04055207011324 885005 885005 ADAPTER FOR SEALING CAP 89.02 CAP 5MM reusable NA RICHARD WOLF GMBH