The Piccolo® AmLyte 13 , used with the Piccolo Xpress® chemistry analyzer, is in
The Piccolo® AmLyte 13 , used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, amylase, aspartate aminotransferase (AST), calcium, c-reactive protein (CRP), creatine kinase, creatinine, glucose, potassium, sodium, total bilirubin and blood urea nitrogen (BUN) in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
The Piccolo® BioChemistry Panel Plus, used with the Piccolo Xpress® chemistry an
The Piccolo® BioChemistry Panel Plus, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), amylase, aspartate aminotransferase (AST), c-reactive protein (CRP), calcium, creatinine, gamma glutamyltransferase (GGT), glucose, total protein, blood urea nitrogen (BUN), and uric acid in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer o
The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended for the in vitro quantitative determination of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL), triglycerides (TRIG), alanine aminotransferase (ALT), aspartate aminotransferase (AST), and glucose (GLU) in capillary (fingerstick) lithium heparinized whole blood, venous lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. From the CHOL, HDL and TRIG determinations, low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), non-HDL cholesterol, and a total cholesterol/high-density lipoprotein cholesterol ratio (TC/H) are calculated by the analyzer.Lipid measurements are used in the diagnosis and treatment of lipid and lipoprotein disorders, atherosclerosis, various liver and renal diseases, diabetes mellitus, and other diseases involving lipid metabolism or various endocrine disorders.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood (venous or capillary) may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® General Chemistry 13 used with the Piccolo blood chemistry analyzer
The Piccolo® General Chemistry 13 used with the Piccolo blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), amylase, aspartate aminotransferase (AST), calcium, creatinine, gamma glutamyltransferase (GGT), glucose, total bilirubin, total protein, blood urea nitrogen (BUN), and uric acid in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Comprehensive Metabolic Panel, used with the Piccolo® blood chemist
The Piccolo® Comprehensive Metabolic Panel, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), aspartate aminotransferase (AST), calcium, chloride, creatinine, glucose, potassium, sodium, total bilirubin, total carbon dioxide, total protein, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Hepatic Function Panel, used with the Piccolo Xpress® chemistry ana
The Piccolo® Hepatic Function Panel, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitroquantitative determinations of alanine aminotransferase, albumin, alkaline phosphatase, aspartate aminotransferase, directbilirubin, total bilirubin, and total protein in heparinized whole blood, heparinized plasma, or serum in a clinical laboratorysetting or point-of-care location.
The Piccolo® General Chemistry 6 , used with the Piccolo® blood chemistry analyz
The Piccolo® General Chemistry 6 , used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine, gamma glutamyltransferase (GGT), glucose, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Liver Panel Plus, used with the Piccolo® blood chemistry analyzer o
The Piccolo® Liver Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, utilizes dry and liquid reagents to provide in vitro quantitative determinations of alanine aminotransferase, albumin, alkaline phosphatase, amylase, aspartate aminotransferase, gamma glutamyltransferase, total bilirubin, and total protein in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
For the quantitative determination of Aspartate Aminotransferase (AST) in human
For the quantitative determination of Aspartate Aminotransferase (AST) in human serum using the Mindray BS-200 analyzer. 2 x 40 ml, 2 x 10 ml
For the quantitative determination of Aspartate Aminotransferase (AST) in human
For the quantitative determination of Aspartate Aminotransferase (AST) in human serum using the Poly-Chem 180 analyzer.6 x 50 ml, 3 x 20 ml
For the quantitative determination of Aspartate Aminotransferase (AST) in human
For the quantitative determination of Aspartate Aminotransferase (AST) in human serum using the Mindray BS-480 analyzer.5 x 60 ml, 5 x 15 ml
For the quantitative determination of Aspartate Aminotransferase (AST) in human
For the quantitative determination of Aspartate Aminotransferase (AST) in human serum. AST is widely distributed in tissues with the highest concentrations found in the liver, heart, skeletal muscle and kidneys. Diseases involving any of these tissues can lead to elevated levels of AST in serum. Following myocardial infarction, AST levels are elevated and reach a peak after 48 to 60 hours.Hepatobiliary diseases such as cirrhosis, metastatic carcinoma and viral hepatitis can show increased levels of AST. Other disorders which can lead to an elevated level of AST are muscular dystrophy, dermatomyositis, acute pancreatitis and infectious mononucleosis.
Pointe AST Reagent packaged for use on the Mindray BA800. 5 x 67ml R1, 5 x 17m
Pointe AST Reagent packaged for use on the Mindray BA800. 5 x 67ml R1, 5 x 17ml R2. For the quantitative determination of Aspartate Aminotransferase (AST) in human serum.
Pointe AST packaged for use on the BS480 Analyzer. 5x60mL, 5x15mL Kit. For the q
Pointe AST packaged for use on the BS480 Analyzer. 5x60mL, 5x15mL Kit. For the quantitative determination of Aspartate Aminotransferase (AST) in human serum on the BS480 Analyzer.
Pointe Scientific, Inc. AST Reagent is for the quantitative determination of Asp
Pointe Scientific, Inc. AST Reagent is for the quantitative determination of Aspartate Aminotransferase (AST) in human serum. Packaged with barcodes for use on AU400, AU480 and AU640.6 x 67ml, 5 x 17ml
AST Reagent, for the quantitative determination of Aspartate Aminotransferase (A
AST Reagent, for the quantitative determination of Aspartate Aminotransferase (AST) in human serum. Size:1 x 2L, 1 x 500mL
Reagent for the quantitative determination of Aspartate Aminotransferase (AST) i
Reagent for the quantitative determination of Aspartate Aminotransferase (AST) in human serum.1 x 30 ml
Reagent for the quantitative determination of Aspartate Aminotransferase (AST) i
Reagent for the quantitative determination of Aspartate Aminotransferase (AST) in human serum.1 x 125 ml