The Intelesens Aingeal is used to monitor and transmit physiological data to a r
The Intelesens Aingeal is used to monitor and transmit physiological data to a remote application for display or analysis by a clinician. The device can be worn by ambulatory or non-ambulatory adult patients in a healthcare environment to support clinical staff when they are carrying out their routine observations or when a patient would otherwise be in an unmonitored or unobserved situation.This re-usable device is intend to be used on the patient for short term periods only.The device is intended to be used on adult patients for monitoring of ECG, respiration, heart rate, skin temperature and activity levels in a healthcare setting.The device can be used where information on ECG, respiration, heart rate, skin temperature, and activity levels would be useful.The device uses on-board ECG arrhythmia detection algorithms to automatically record and send ECG data if the user is suspected to be experiencing an arrhythmia event. The device transmits the data to the remote application at user defined intervals or upon the detection of an arrhythmia event (arrhythmia or threshold breach).
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The Aingeal 3-Patch Electrode Array is an electrocardiograph (ECG), respiration
The Aingeal 3-Patch Electrode Array is an electrocardiograph (ECG), respiration and temperature electrode. It is a disposable, pre-gelled, self-adhesive, single lead electrode array, which is designed to be used in contact with the patient’s skin. The device is used in conjunction with the Aingeal Device in order to monitor vital signs for ECG, respiration, motion and temperature for ambulatory and non-ambulatory patients in a hospital environment.This is a single use device and is intended to be used on an adult patient for a period of up to 72 hours before a replacement is required.
The zensor monitoring device is a small, lightweight, wearable, non-invasive, re
The zensor monitoring device is a small, lightweight, wearable, non-invasive, re-chargeable battery operated portable system connected to an electrode accessory (single-use disposable Intelesens zensor Electrode Array) which in turn is in contact with the patient’s body. The device is to be used in the patient’s home environment to provide clinicians with patient physiological data, while allowing for patient mobility. The zensor monitoring system provides full disclosure ECG and cardiac event monitoring for adult patients. The physiological parameters monitored include ECG and Respiration waveforms, Heart Rate and Respiration Rate, as well as lethal and high acuity arrhythmias (Asystole, Tachycardia, Ventricular Fibrillation, Bradycardia and Atrial Fibrillation). The zensor monitoring device has the option to store full disclosure ECG & Respiration data and/or wirelessly transmit pre-defined event alerts to the Intelesens zensoronline system for review by healthcare practitioners. All physiological data stored on the device can be downloaded for viewing on Intelesens zensor+ (Ambulatory ECG Full Disclosure ECG and Event Viewer) for later analysis by a clinician.
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The zensor software system is a web and PC based tool assisting clinicians in ma
The zensor software system is a web and PC based tool assisting clinicians in managing patients being monitored with Intelesens' medical devices. The web and PC components of the software can be configured to be used individually or together.The zensoronline software has the option to receive wirelessly transmitted pre-defined event alerts from the Intelesens' monitoring device for review by healthcare practitioners and/or review all physiological data that has been previously stored and downloaded from the monitoring device for later analysis by a clinician.The system is intended to be used to obtain physiological readings for use in routine check-ups. Any events or variations in physiological readings are not intended to be used to summon emergency care.
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The zensor software system is a web and PC based tool assisting clinicians in ma
The zensor software system is a web and PC based tool assisting clinicians in managing patients being monitored with Intelesens' medical devices. The web and PC components of the software can be configured to be used individually or together.The zensor+ software allows review of all physiological data that has been previously stored and downloaded from the monitoring device for later analysis by a clinician.The system is intended to be used to obtain physiological readings for use in routine check-ups. Any events or variations in physiological readings are not intended to be used to summon emergency care.
MHX
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
The zensor electrode array, electrocardiograph (ECG) and respiration electrode i
The zensor electrode array, electrocardiograph (ECG) and respiration electrode is a disposable, pre-gelled, self-adhesive, three lead electrode array, which is in contact with the patient's skin. The device is used in conjunction with the zensor device in order to monitor vital signs for ECG, respiration and motion for ambulatory and non-ambulatory patients in a home environment. This is a single use device and is intended to be used on an adult patient for a period of up to 6 days before a replacement is required.
The zensor electrode array, electrocardiograph (ECG) and respiration electrode i
The zensor electrode array, electrocardiograph (ECG) and respiration electrode is a disposable, pre-gelled, self-adhesive, three lead electrode array, which is in contact with the patient's skin. The device is used in conjunction with the zensor device in order to monitor vital signs for ECG, respiration and motion for ambulatory and non-ambulatory patients in a home environment. This is a single use device and is intended to be used on an adult patient for a period of up to 72 hours before a replacement is required.
International (non-U.S.) model; optional camera that can be used to record video
International (non-U.S.) model; optional camera that can be used to record video of the patient.
International (non-U.S.) model; optional 40 input EEG amplifier for direct recor
International (non-U.S.) model; optional 40 input EEG amplifier for direct recording of EEG and other physiological signals from the patient.
Research model; optional 40 input EEG amplifier for direct recording of EEG and
Research model; optional 40 input EEG amplifier for direct recording of EEG and other physiological signals from the patient.
Optional 40 input EEG amplifier for direct recording of EEG and other physiologi
Optional 40 input EEG amplifier for direct recording of EEG and other physiological signals from the patient.
International (non-U.S.) model; optional 16 input EEG amplifier for direct recor
International (non-U.S.) model; optional 16 input EEG amplifier for direct recording of EEG and other physiological signals from the patient.
Research model; optional 16 input EEG amplifier for direct recording of EEG and
Research model; optional 16 input EEG amplifier for direct recording of EEG and other physiological signals from the patient.
Optional 16 input EEG amplifier for direct recording of EEG and other physiologi
Optional 16 input EEG amplifier for direct recording of EEG and other physiological signals from the patient.
A portable, computer-based system that can continuously record, display, store a
A portable, computer-based system that can continuously record, display, store and analyze physiological data from multiple monitoring sources in real time.
International (non-U.S.) model; a portable, computer-based system that can conti
International (non-U.S.) model; a portable, computer-based system that can continuously record, display, store and analyze physiological data from multiple monitoring sources in real time.
Research model; a portable, computer-based system that can continuously record,
Research model; a portable, computer-based system that can continuously record, display, store and analyze physiological data from multiple monitoring sources in real time.
Domestic (U.S.) model; a portable, computer-based system that can continuously r
Domestic (U.S.) model; a portable, computer-based system that can continuously record, display, store and analyze physiological data from multiple monitoring sources in real time.
IntelliVue NMT Hand Adapter for use with IntelliVue NMT Patient Cable 9898031745
IntelliVue NMT Hand Adapter for use with IntelliVue NMT Patient Cable 989803174581 and IntelliVue Neuro Muscular Transmission Module 865383. Adapter is reusable. 1 Sales Unit = 10 each
The M2786A in combination with the spirometry module M1014A is designed to allow
The M2786A in combination with the spirometry module M1014A is designed to allow measurement of airway pressures, flow, minute volume, tidal volume, airway compliance, airway resistance and CO2.