Programmed Death Ligand 1 (73-10) monoclonal antibody is intended to be used for
Programmed Death Ligand 1 (73-10) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of endogenous PD-L1 protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Anaplastic Lymphoma Kinase (5A4) monoclonal antibody is intended to be used for
Anaplastic Lymphoma Kinase (5A4) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of endogenous ALK and ALK fusion proteins in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Cytokeratin (AE1/AE3) monoclonal antibody is intended to be used for the qualita
Cytokeratin (AE1/AE3) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human cytokeratins 56.5, 50, 50’, 48 and 40 kD of the acidic subfamily and 65 to 67, 64, 59, 58, 56 and 52 kD of the basic subfamily in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Human Herpesvirus (Type 8) (13B10) monoclonal antibody is intended to be used fo
Human Herpesvirus (Type 8) (13B10) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human herpesvirus (Type 8) (latent nuclear antigen) in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Muc-6 Glycoprotein (CLH5) monoclonal antibody is intended to be used for the qua
Muc-6 Glycoprotein (CLH5) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of Muc-6 glycoprotein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Muc-5AC Glycoprotein (CLH2) monoclonal antibody is intended to be used for the q
Muc-5AC Glycoprotein (CLH2) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of Muc-5AC Glycoprotein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Muc-1 Glycoprotein (Ma695) monoclonal antibody is intended to be used for the qu
Muc-1 Glycoprotein (Ma695) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of Muc-1 Glycoprotein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
c-erbB-2 Oncoprotein (CB11) monoclonal antibody is intended to be used for the q
c-erbB-2 Oncoprotein (CB11) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of c-erbB-2 oncoprotein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
c-erbB-2 Oncoprotein (CB11) monoclonal antibody is intended to be used for the q
c-erbB-2 Oncoprotein (CB11) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of c-erbB-2 oncoprotein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Inhibin Alpha (R1) monoclonal antibody is intended to be used for the qualitativ
Inhibin Alpha (R1) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human inhibin alpha in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Immunoglobulin G (RWP49) monoclonal antibody is intended to be used for the qual
Immunoglobulin G (RWP49) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of immunoglobulin G in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD15 (MMA) monoclonal antibody is intended to be used for the qualitative identi
CD15 (MMA) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD15 protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Carcinoembryonic Antigen (CD66e) (COL-1) monoclonal antibody is intended to be u
Carcinoembryonic Antigen (CD66e) (COL-1) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of carcinoembryonic antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD79a (JCB117) monoclonal antibody is intended to be used for the qualitative id
CD79a (JCB117) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD79a protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Alpha-Methylacyl-CoA Racemase (EPMU1) antibody is intended to be used for the qu
Alpha-Methylacyl-CoA Racemase (EPMU1) antibody is intended to be used for the qualitative identification by light microscopy of alpha-methylacyl-CoA racemase molecules in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Napsin A (IP64) antibody is intended to be used for the qualitative identificati
Napsin A (IP64) antibody is intended to be used for the qualitative identification by light microscopy of napsin A molecules in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Enhancer of Zeste Homolog 2 (Drosophila) (EZH2) (6A10) monoclonal antibody is in
Enhancer of Zeste Homolog 2 (Drosophila) (EZH2) (6A10) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human EZH2 antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Cyclin D1 (EP12) monoclonal antibody is intended to be used for the qualitative
Cyclin D1 (EP12) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of cyclin D1 protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
von Willebrand Factor (36B11) monoclonal antibody is intended to be used for the
von Willebrand Factor (36B11) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human von Willebrand Factor in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD13 (38C12) monoclonal antibody is intended to be used for the qualitative iden
CD13 (38C12) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD13 antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Oct-3/4 (N1NK) monoclonal antibody is intended to be used for the qualitative id
Oct-3/4 (N1NK) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of Oct-3/4 antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Muc-2 (Ccp58) antibody is intended to be used for the qualitative identification
Muc-2 (Ccp58) antibody is intended to be used for the qualitative identification by light microscopy of Muc-2 glycoprotein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Chromogranin A (5H7) monoclonal antibody is intended to be used for the qualitat
Chromogranin A (5H7) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human chromogranin A in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD117 (EP10) monoclonal antibody is intended to be used for the qualitative iden
CD117 (EP10) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human c-kit oncoprotein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Immunoglobulin D (DRN1C) monoclonal antibody is intended to be used for the qual
Immunoglobulin D (DRN1C) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of Immunoglobulin D in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD31 (JC70A) monoclonal antibody is intended to be used for the qualitative iden
CD31 (JC70A) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD31 (PECAM-1) molecules in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD163 (10D6) monoclonal antibody is intended to be used for the qualitative iden
CD163 (10D6) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD163 antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Mammaglobin (EP249) monoclonal antibody is intended to be used for the qualitati
Mammaglobin (EP249) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of humanMammaglobin protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system(includes Leica BOND-MAX system and Leica BOND-III system).
p120 Catenin (EP66) monoclonal antibody is intended to be used for the qualitati
p120 Catenin (EP66) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human p120 Catenin protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CDX2 (EP25) monoclonal antibody is intended to be used for the qualitative ident
CDX2 (EP25) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CDX2 protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD103 (EP206) monoclonal antibody is intended to be used for the qualitative ide
CD103 (EP206) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD103 proteinin formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BONDMAXsystem and Leica BOND-III system).
CD4 (4B12) monoclonal antibody is intended to be used for the qualitative identi
CD4 (4B12) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD4 antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD20 (L26) monoclonal antibody is intended to be used for the qualitative identi
CD20 (L26) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD20 protein informalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BONDMAXsystem and Leica BOND-III system).
CD20 (L26) monoclonal antibody is intended to be used for the qualitative identi
CD20 (L26) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD20 protein informalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BONDMAXsystem and Leica BOND-III system).
CD10 (56C6) monoclonal antibody is intended to be used for the qualitative ident
CD10 (56C6) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of the human CD10 molecule in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Melanoma Marker (HMB45) monoclonal antibody is intended to be used for the quali
Melanoma Marker (HMB45) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human HMB45 antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD34 (QBEnd/10) monoclonal antibody is intended to be used for the qualitative i
CD34 (QBEnd/10) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human endothelial cell marker (CD34) in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
CD3 (LN10) monoclonal antibody is intended to be used for the qualitative identi
CD3 (LN10) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human CD3 molecule in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Melan A (A103) monoclonal antibody is intended to be used for the qualitative id
Melan A (A103) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human melan A molecule in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Vimentin (V9) monoclonal antibody is intended to be used for the qualitative ide
Vimentin (V9) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human vimentin in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Ki67 (MM1) monoclonal antibody is intended to be used for the qualitative identi
Ki67 (MM1) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human Ki67 nuclear antigen in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Gross Cystic Disease Fluid Protein-15 (23A3) monoclonal antibody is intended to
Gross Cystic Disease Fluid Protein-15 (23A3) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human gross cystic disease fluid protein (15 kD) in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
p63 (7JUL) monoclonal antibody is intended to be used for the qualitative identi
p63 (7JUL) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human p63 protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Cytokeratin 20 (Ks20.8) monoclonal antibody is intended to be used for the quali
Cytokeratin 20 (Ks20.8) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human cytokeratin 20 intermediate filament protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Cytokeratin 20 (Ks20.8) monoclonal antibody is intended to be used for the quali
Cytokeratin 20 (Ks20.8) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human cytokeratin 20 intermediate filament protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Estrogen Receptor Clone 6F11 (ER 6F11) Mouse Monoclonal antibody is intended for
Estrogen Receptor Clone 6F11 (ER 6F11) Mouse Monoclonal antibody is intended for laboratory use to qualitatively identify estrogen receptor (ER) antigen in sections of formalin fixed, paraffin embedded breast cancer tissue by immunohistochemistry methods.
Cytokeratin 7 (RN7) monoclonal antibody is intended to be used for the qualitati
Cytokeratin 7 (RN7) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human cytokeratin 7 intermediate filament protein in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Cytokeratin 14 (LL002) monoclonal antibody is intended to be used for the qualit
Cytokeratin 14 (LL002) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human cytokeratin 14 in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Lambda Light Chain (SHL53) monoclonal antibody is intended to be used for the qu
Lambda Light Chain (SHL53) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human lambda light chains in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Kappa Light Chain (CH15) monoclonal antibody is intended to be used for the qual
Kappa Light Chain (CH15) monoclonal antibody is intended to be used for the qualitative identification by light microscopy of human kappa light chains in formalin-fixed, paraffin-embedded tissue by immunohistochemical staining using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
The BOND FISH Kit enables the user to perform fluorescence in situ hybridization
The BOND FISH Kit enables the user to perform fluorescence in situ hybridization (FISH) on the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Anti-Fluorescein Antibody is intended for use with fluorescein-labeled nucleic a
Anti-Fluorescein Antibody is intended for use with fluorescein-labeled nucleic acid probes bound to specific nucleotide sequences informalin-fixed, paraffin-embedded tissue by in situ hybridization (ISH) using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Anti-Biotin Antibody is intended for use with biotin-labeled nucleic acid probes
Anti-Biotin Antibody is intended for use with biotin-labeled nucleic acid probes bound to specific nucleotide sequences in formalin-fixed, paraffin-embedded tissue by in situ hybridization (ISH) using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
The Stringency Wash Solution is intended for use with nucleic acid probes to red
The Stringency Wash Solution is intended for use with nucleic acid probes to reduce non-specific hybridization in formalin-fixed, paraffin-embedded tissue when performing in situ hybridization (ISH) using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
Anti-Fluorescein Antibody is intended for use with fluorescein-labeled nucleic a
Anti-Fluorescein Antibody is intended for use with fluorescein-labeled nucleic acid probes bound to specific nucleotide sequences in formalin-fixed, paraffin-embedded tissue by in situ hybridization (ISH) using the automated BOND system (includes Leica BOND-MAX system and Leica BOND-III system).
The BOND Aspirating Probe Cleaning System is intended for automated cleaning of
The BOND Aspirating Probe Cleaning System is intended for automated cleaning of aspirating probes on BOND instruments, using the aspirating probe cleaning protocol installed in BOND systems (includes Leica BOND-MAX system and Leica BOND-III system).
The NovocastraTM Peroxidase Block RE7101 is intended for use in the peroxidase b
The NovocastraTM Peroxidase Block RE7101 is intended for use in the peroxidase based immunohistochemical (IHC) staining procedures described in the Instructions for Use of the NovocastraTM Peroxidase Detection Systems RE7110-K/RE7120-K, NovocastraTM Concentrated Peroxidase Detection System RE7130-K and NovoLinkTM Polymer Detection Systems RE7140-K/RE7150-K.
The Novocastra™ Protein Block RE7102 is intended for use in immunohistochemical
The Novocastra™ Protein Block RE7102 is intended for use in immunohistochemical (IHC) staining procedure described in the Instructions for Use of the NovocastraTM Peroxidase Detection Systems RE7110-K/RE7120-K, NovocastraTM Concentrated Peroxidase Detection System RE7130-K and NovoLinkTM Polymer Detection Systems RE7140-K/RE7150-K.
Novocastra™ Hematoxylin RE7107 is intended for use in immunohistochemical (IHC)
Novocastra™ Hematoxylin RE7107 is intended for use in immunohistochemical (IHC) staining procedures such as those described in the Instructions for Use of the Novocastra™ Peroxidase Detection Systems RE7110-K/RE7120-K, Novocastra™ Concentrated Peroxidase Detection System RE7130-K and Novolink™ Polymer Detection Systems RE7140-K/RE7150-K.
The Novocastra™ Epitope Retrieval Solutions RE7113, RE7114, RE7116 and RE7119 ar
The Novocastra™ Epitope Retrieval Solutions RE7113, RE7114, RE7116 and RE7119 are intended for Heat Induced Epitope Retrieval on formalin-fixed, paraffin-embedded tissue sections as part of an immunohistochemical procedure.
The Novocastra™ Epitope Retrieval Solutions RE7113, RE7114, RE7116 and RE7119 ar
The Novocastra™ Epitope Retrieval Solutions RE7113, RE7114, RE7116 and RE7119 are intended for Heat Induced Epitope Retrieval on formalin-fixed, paraffin-embedded tissue sections as part of an immunohistochemical procedure.
The Novocastra™ Epitope Retrieval Solutions RE7113, RE7114, RE7116 and RE7119 ar
The Novocastra™ Epitope Retrieval Solutions RE7113, RE7114, RE7116 and RE7119 are intended for Heat Induced Epitope Retrieval on formalin-fixed, paraffin-embedded tissue sections as part of an immunohistochemical procedure.
Novocastra™ IHC Diluent RE7133 is intended for use as a diluent for Novocastra™
Novocastra™ IHC Diluent RE7133 is intended for use as a diluent for Novocastra™ primary antibodies, Novocastra™ ConcentratedBiotinylated Secondary Antibody RE7108 and Novocastra™ Concentrated Streptavidin-HRP RE7109 in immunohistochemical (IHC) procedures.
NovocastraTM Enzyme Proteinase K (IHC) is intended for the enzymatic pretreatmen
NovocastraTM Enzyme Proteinase K (IHC) is intended for the enzymatic pretreatment of formalin-fixed, paraffin-embedded tissue sections prior to incubation with a primary antibody in an immunohistochemical (IHC) procedure.
"The MGB Alert Platinum Master Mix is intended for use in the development of lab
"The MGB Alert Platinum Master Mix is intended for use in the development of laboratory assays whichtarget DNA analytes using real-time PCR. The MGB Alert Platinum Master Mix itself generates nodiagnostic information or data."
The MGB Alert Platinum Master Mix is intended for use in the development of labo
The MGB Alert Platinum Master Mix is intended for use in the development of laboratory assays which target DNA analytes using real-time PCR. The MGB Alert Platinum Master Mix itself generates no diagnostic information or data.
The MGB Alert Platinum Master Mix is intended for use in the development of labo
The MGB Alert Platinum Master Mix is intended for use in the development of laboratory assays which target DNA analytes using real-time PCR. The MGB Alert Platinum Master Mix itself generates no diagnostic information or data.
The MGB Alert Platinum Master Mix is intended for use in the development of labo
The MGB Alert Platinum Master Mix is intended for use in the development of laboratory assays which target DNA analytes using real-time PCR. The MGB Alert Platinum Master Mix itself generates no diagnostic information or data.
The MGB Alert PCR Master Mix package includes ready to use 2x master mix contain
The MGB Alert PCR Master Mix package includes ready to use 2x master mix containinga non-Taq thermostable enzyme lacking exonuclease activity and provided in antibodyinactivated form. An initial high-temperature incubation step denatures the antibodies toactivate the enzyme. The master mix also includes Uracil-DNA Glycosylase (UDG) anddUTP to prevent carry-over contamination. MGB Alert PCR Enhancer and MGB Alert 25 mMMgCl2 are provided for additional flexibility in optimizing reaction conditions.
The MGB Alert One-Step Reverse Transcriptase PCR Master Mix package includes a 2
The MGB Alert One-Step Reverse Transcriptase PCR Master Mix package includes a 2X mastermix containing a thermostable polymerase with exonuclease activity and provided in hot-start format.Included are 100X reverse transcriptase, 50X RNase inhibitor, and RNase-free water in separatetubes.
The MGB Alert PCR Master Mix package includes ready to use 2x master mix contain
The MGB Alert PCR Master Mix package includes ready to use 2x master mix containing a non-Taq thermostable enzyme lacking exonuclease activity and provided in antibody inactivated form. An initial high-temperature incubation step denatures the antibodies to activate the enzyme. The master mix also includes Uracil-DNA Glycosylase (UDG) and dUTP to prevent carry-over contamination. MGB Alert PCR Enhancer and MGB Alert 25 mM MgCl2 are provided for additional flexibility in optimizing reaction conditions.
The MGB Alert Platinum Master Mix is intended for use in the development of labo
The MGB Alert Platinum Master Mix is intended for use in the development of laboratory assays which target DNA analytes using real-time PCR. The MGB Alert Platinum Master Mix itself generates no diagnostic information or data.
The MGB Alert PCR Master Mix package includes ready to use 2x master mix contain
The MGB Alert PCR Master Mix package includes ready to use 2x master mix containinga non-Taq thermostable enzyme lacking exonuclease activity and provided in antibodyinactivated form. An initial high-temperature incubation step denatures the antibodies toactivate the enzyme. The master mix also includes Uracil-DNA Glycosylase (UDG) anddUTP to prevent carry-over contamination. MGB Alert PCR Enhancer and MGB Alert 25 mMMgCl2 are provided for additional flexibility in optimizing reaction conditions.