No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04987669101421 1.0 Data Acquisition Service for NAVIS-EX (hereafter referred to as DAS) acquires da Data Acquisition Service for NAVIS-EX (hereafter referred to as DAS) acquires data from measurement devices and transfers it to NAVIS-EX.In addition to acquisition of measurement data, DAS registers patients newly registered with the ALScan/CEM-530 to NAVIS-EX. NFJ System, Image Management, Ophthalmic 2 Data Acquisition Service for NAVIS-EX
2 04987669101360 1.1 The AL-Scan Viewer for NAVIS-EX software (hereafter referred to as AL-Scan Viewe The AL-Scan Viewer for NAVIS-EX software (hereafter referred to as AL-Scan Viewer) is used to handle the AL-Scan data within NAVIS-EX. This function is added to the computer as a plug-in for NAVISEX. The measured value data and waveform can be displayed, the IOL power can be calculated, andthe toric lens assist data can be created. The AL-Scan data is imported to NAVIS-EX using separate software, Data Acquisition Service. NFJ System, Image Management, Ophthalmic 2 AL-Scan Viewer for NAVIS-EX
3 04987669101322 11143-7500 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(25G/Coaxial)
4 04987669101292 11143-6700 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(27G/Straight)
5 04987669101285 11143-6600 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(25G/Angled)
6 04987669101124 GDA01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.*1 Safety Optics with Low Impact on Cornea HQF Laser, Ophthalmic 2 Attachable delivery unit (SL130)
7 04987669100899 17434-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system.ZEISS SL130 type is available. HQF Laser, Ophthalmic 2 Attachable delivery unit (SL130)
8 04987669100851 GYC-500 The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for oph The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for ophthalmology using a 532 nm diode-pumped solid-state laser (green laser beam) as the treatment beam source. The device incorporates a diode-pumped laser that enables efficient laser beam emission at 532 nm. For the laser beam delivery, various types of delivery units may be employed. This allows performance of transpupillary photocoagulation using a slit lamp or binocular indirect ophthalmoscope. HQF Laser, Ophthalmic 2 Green Laser Photocoagulator
9 04987669100776 OPD-Scan III The NIDEK refractive power / corneal analyzer OPD-Scan III (hereafter referred t The NIDEK refractive power / corneal analyzer OPD-Scan III (hereafter referred to as “the device”) measures objective refractive error, corneal curvature, shape of the anterior corneal surface (topography), and pupil size of the patient’s eye, and analyzes wavefront aberration. The measured refractive error can be used for reference when prescribing corrective lenses such as glasses or contact lenses. HLQ,HKO Keratoscope, Ac-Powered,Refractometer, Ophthalmic 1 REFRACTIVE POWER / CORNEAL ANALYZER
10 04987669100561 F-10 The F-10 captures and records the confocal images of fundus by laser scanning us The F-10 captures and records the confocal images of fundus by laser scanning using a selection of laser colors: IR (infrared), blue, green, and red. Indocyanine green (ICG) angiography and fluorescein angiography (FAG) are also possible. MYC Ophthalmoscope, Laser, Scanning 2 OPHTHALMOSCOPE
11 04987669100523 NAVIS-EX The NAVIS-EX image filing software is software that acquires data from the follo The NAVIS-EX image filing software is software that acquires data from the following NIDEK fundus photography devices and files it for easy transfer to external systems. NAVIS-EX is equipped with functions for image acquiring, image display, image drawing, image processing, image measurement, panorama image creation, stereo image observation, composite image creation, and Follow-Up. (According to the image, available functions are limited.) Image data can be transferred by network or e-mail. NAVIS-EX can construct a network among multiple terminals and refers to and edits data from the clientPC. NFG,NFF,MYC,HKI,HPT,OBO,HJO,NFJ Device, Communications, Images, Ophthalmic,Device, Storage, Images, Ophthalmic,O Device, Communications, Images, Ophthalmic,Device, Storage, Images, Ophthalmic,Ophthalmoscope,Laser,Scanning,Camera, Ophthalmic, Ac-Powered,Perimeter, Automatic, Ac-Powered,Tomography, Optical Coherence,Biomicroscope, Slit-Lamp, Ac-Powered,System, Image Management, Ophthalmic 1 Image filing software
12 04987669100011 EC-5000 NIDEK EXCIMER LASER CORNEAL SURGERY SYSTEM, model EC-5000CXIII, is an ophthalmic NIDEK EXCIMER LASER CORNEAL SURGERY SYSTEM, model EC-5000CXIII, is an ophthalmic laser system used for correction of corneal refraction and ablation of the corneal surface. The system is composed of a laser generator which produces an excimer laser radiation of wavelength193nm, a beam delivery unit, an optical system for observation, a gas system, and a computer for system control. The system is designed to be user friendly for easy and safe operation with NIDEK’s advanced optoelectronic technology. LZS Excimer Laser System 3 NA
13 04987669101414 TS-310 The TS-310 is a space-saving automated refraction system that uses a combination The TS-310 is a space-saving automated refraction system that uses a combination of the refractor head of the RT-3100 and a control box.• With the high precision LCD, visual acuity of 5 m as well as near visual acuity of 40 cm can be measured with the same accuracy as a standard refraction using actual distances.• The objective data measured by a NIDEK auto refractometer and the lensometry data measured by a NIDEK lensmeter can be imported and used in this device. HKN,HOX Refractor, Manual, Non-Powered, Including Phoropter,Chart, Visual Acuity 1 Tabletop Refraction System
14 04987669101346 1.13 The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) LZS Excimer Laser System 3 Final Fit
15 04987669101247 11143-6200 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(20G/Angled)
16 04987669101131 GDB01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated.*1 Safety Optics with Low Impact on Cornea HQF Laser, Ophthalmic 2 Slit lamp delivery unit (NIDEK SL)
17 04987669101117 YLC-500 The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagu The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagulator consisting of a main laser device, a control box, and a power supply. With various types of laser delivery units, it comprises a photocoagulation system. The YLC-500 uses a 577 nm optically pumped semiconductor laser (yellow laser beam) as the treatment beam source. The pumped yellow laser beam (treatment beam) and the aiming beam (635 nm, red laser beam) are fed coaxially into the fiber optic cable. The output terminal of the fiber optic cable is connected to a delivery unit. The laser beam is formed into the desired spot size by the optical system, then the laser beam is emitted to the target area. The delivery units are equipped with a protective filter that protects the physician’s eyes from exposure to the treatment beam reflected from the patient’s eye or contact lens. HQF Laser, Ophthalmic 2 Yellow Laser Photocoagulator
18 04987669100301 17118-0000 This Endophotocoagulation Delivery Unit is used for endophotocoagulation. The de This Endophotocoagulation Delivery Unit is used for endophotocoagulation. The delivery unit is comprised of an endophoto probe, a relay adapter, a protective filter unit, and a carrying case. The photocoagulation laser system can be easily formed by connecting the endophoto probe to theGREEN LASER PHOTOCOAGULATOR Model GYC-1000 main body and connecting the protective filter to the GYC-1000 main body and the surgical microscope. This photocoagulation laser system enables endophotocoagulation with the green laser (wavelength: 532 nm) while observing theaffected area through the surgical microscope. This delivery unit is intended to be used with the protective filter unit attached to surgical microscopes. NIDEK provides following four types of delivery units according to the types of protective filters and the surgical microscopes*1.Before use, check the type of your surgical microscope and delivery unit. GEX Powered Laser Surgical Instrument 2 Endophotocoagulation delivery unit
19 04987669100066 TONOREF II AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objecti AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objective refraction, corneal shape measurement, and non-contact tonometry measurement by incorporating a standard auto ref/keratometer and non-contact tonometer into one unit. The objective refraction function measures spherical powers, cylindrical powers and cylinder axis. The corneal shape measurement function measures the radius of corneal curvature (corneal refractive powers), the direction of the steepest meridian, and the amount of corneal astigmatism. The non-contact tonometry function measures the intraocular pressure without contacting the eye. HKX,HKO,HLQ Tonometer, Ac-Powered,Refractometer, Ophthalmic,Keratoscope, Ac-Powered 1 AUTO REF/KERATO/TONOMETER
20 04987669100042 1.12 The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) LZS Excimer Laser System 3 Final Fit™
21 04987669100035 1.11US The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) LZS Excimer Laser System 3 Final Fit™
22 04987669101575 CP-9 The Nidek CHART PROJECTOR CP-9 is a chart presenting device that can achieve ref The Nidek CHART PROJECTOR CP-9 is a chart presenting device that can achieve refraction at a distance of 2.9 m to 6.1 m (standard 5 m).The main unit is operated by a wireless remote control or the control box on a motorized refractor (RT). HOX Chart, Visual Acuity 1 CHART PROJECTOR
23 04987669101452 YC-200 The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system cons The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system consisting of a main body containing the laser, a head rest, a control box, and a connector box. The device uses a 1,064 nm pulsed Nd: YAG laser as the treatment beam source. Laser pulses are generated using a method called passive Q-switching. With this method, short high-power pulses can be emitted. At the target, the emitted pulses cause photodisruption, which is fragmentation of tissue using light energy. HQF,HJO Laser, Ophthalmic,Biomicroscope, Slit-Lamp, Ac-Powered 2 Ophthalmic YAG Laser System
24 04987669101049 DS-10G DS-10G is a digital hand-held camera used to record digital photographs and vide DS-10G is a digital hand-held camera used to record digital photographs and video of the human body. FXF Speculum, Illuminated 1 DIGITAL MEDICAL SCOPE
25 04987669101001 DS-20F NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital phot NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. PJZ Camera, Ophthalmic, General-Use 2 DIGITAL MEDICAL SCOPE
26 04987669100967 17166-6100 Expansion box is the optional accessory that is used to connect a scan delivery Expansion box is the optional accessory that is used to connect a scan delivery unit and the external devices (LAN cable, barcode scanner, or magnetic card reader) to the GYC-500. HQF Laser, Ophthalmic 2 Expansion box
27 04987669101377 SL-2000 The NIDEK SLIT LAMP SL-2000 is used to magnify the eyeball, eyelid, and eyelash The NIDEK SLIT LAMP SL-2000 is used to magnify the eyeball, eyelid, and eyelash of patients for observation, using slit illumination light. HJO Biomicroscope, Slit-Lamp, Ac-Powered 2 Slit Lamp
28 04987669101032 DS-10E DS-10E is a digital hand-held otoscope used to record digital photographs and vi DS-10E is a digital hand-held otoscope used to record digital photographs and video of the human ear’s canal and tympanic membrane. ERA Otoscope 1 DIGITAL MEDICAL SCOPE
29 04987669100998 DS-10F NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital pho NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. HKI Camera, Ophthalmic, Ac-Powered 2 DIGITAL MEDICAL SCOPE
30 04987669101179 GEA01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). The ZEISS SL130 type is available: *1 Safety Optics with Low Impact on Cornea HQF Laser, Ophthalmic 2 Scan Attachable delivery unit (SL130)
31 04987669101070 DS-10 Control Unit The assembly system (control unit & DS-10EA Adapter & existing endoscope in the The assembly system (control unit & DS-10EA Adapter & existing endoscope in the market) can be used to record digital photographs and video ofthe body. FTT,ERA,FSP,FXF,HKI Camera, Still, Surgical,Otoscope,Loupe, Diagnostic/Surgical,Speculum, Illuminate Camera, Still, Surgical,Otoscope,Loupe, Diagnostic/Surgical,Speculum, Illuminated,Camera, Ophthalmic, Ac-Powered 1 DIGITAL MEDICAL SCOPE
32 04987669101056 DS-10EA DS-10EA Adapter is designed to connect the control unit of DS-10 and the existin DS-10EA Adapter is designed to connect the control unit of DS-10 and the existing endoscope in the market. The assembly system (control unit & DS-10EA Adapter & existing endoscope in the market) can be used to record digital photographs and video of the body. FTT Camera, Still, Surgical 1 DIGITAL MEDICAL SCOPE
33 04987669101025 DS-10D DS-10D is a digital hand-held dermatoscope used to record digital photographs an DS-10D is a digital hand-held dermatoscope used to record digital photographs and video of the human skin. FSP Loupe, Diagnostic/Surgical 1 DIGITAL MEDICAL SCOPE
34 04987669101018 DS-10A DS-10A is a digital hand-held anterior scope used to record digital photographs DS-10A is a digital hand-held anterior scope used to record digital photographs and video of anterior area of the human eye and surrounding area. FXF Speculum, Illuminated 1 DIGITAL MEDICAL SCOPE
35 04987669100905 17441-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. HAAG 900 series type is available. HQF Laser, Ophthalmic 2 Attachable delivery unit (900BQ)
36 04987669100882 17432-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. NIDEK SL-1800 type is available. HQF Laser, Ophthalmic 2 Attachable delivery unit (SL-1800)
37 04987669100875 17431-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. The ZEISS 30 SL type is availabe. HQF Laser, Ophthalmic 2 Attachable delivery unit (30SL/M)
38 04987669100837 PM-700 The PD meter model PM-700 is a pupillary distance meter improved with a built-in The PD meter model PM-700 is a pupillary distance meter improved with a built-in computer and LCD digital display. HLG Pupillometer, Ac-Powered 1 PD Meter
39 04987669100431 NT-530 The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry mea The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology. HKX Tonometer, Ac-Powered 2 NON CONTACT TONOMETER
40 04987669100424 NT-510 The NON CONTACT TONOMETER Model NT-510 is designed for non-contact tonometry mea The NON CONTACT TONOMETER Model NT-510 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology. HKX Tonometer, Ac-Powered 2 NON CONTACT TONOMETER
41 04987669100288 17112-0000 This unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC- 1000 This unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC- 1000 (main body) to comprise the photocoagulation system and applied to the treatment of the affected area using the B.I.O. delivery unit (HEINE OMEGA 500). The comprised photocoagulation system makes it possible to switch between photocoagulation with the green laser beam (wavelength: 532 nm) and observation with the B.I.O. GEX Powered Laser Surgical Instrument 2 BIO delivery unit (Heine OMEGA)
42 04987669100233 17402-0000 This delivery unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model This delivery unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC-1000 (main body) to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800. The integrated delivery unit which incorporates the SL-1800 comprises the photocoagulation system in connection with the GYC-1000 main body. The attachable delivery unit is mainly the photocoagulation unit and the protective filter unit. They are attached to your slit lamp (NIDEK SL-1800) to comprise the integrated delivery unit. The comprisedintegrated delivery is connected to the GYC-1000 to comprise the photocoagulation system. This photocoagulation system allows the operator to select between photocoagulation with the green laser beam (wavelength: 532 nm) and observation of the affected area with the slit lamp. GEX Powered Laser Surgical Instrument 2 Attachable delivery unit (SL-1800)
43 04987669100134 17462-0000 This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body. A attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit.They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a slit lamp delivery unit. The comprised slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. HQF Laser, Ophthalmic 2 Attachable delivery unit (SL-1800)
44 04987669100080 MC-500 The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for ophthalmology with the light source of wavelengths 647, 577, and 532 nm. As the conventional laser photocoagulators, the MC-500 can be used for retinal photocoagulation for treatment of ocular fundus diseases like diabetic retinopathy, age-related macular degeneration, retinopathy of prematurity, and retinal detachment, or for laser iridotomy and laser trabeculoplasty for treatment of glaucoma. The device incorporates two types of lasers (diode-pumped solid state laser and laser diode) which enable efficient obtainment of laser beam oscillation of each wavelength. As the conventional device, various types of laser delivery units can be used. Therefore, transpupillary photocoagulation can be performed using various delivery units such as slit lamps and binocular indirect ophthalmoscope. HQF Laser, Ophthalmic 2 Multicolor Laser Photocoagulator
45 04987669100059 CP-770 The NIDEK Chart Projector CP-770 is a test chart presenting device which can ach The NIDEK Chart Projector CP-770 is a test chart presenting device which can achieve refraction distance from 2.9 m to 6.1 m. The device is controlled by a wireless remote control or a control box on the refractor (RT).The CP-770 features the following:• Equipped with 33 types of charts (27 types for Type UK) including various kinds of binocular charts• Program function that allows chart presentation with the touch of a button• Versatile masking function that can even offer the display of even a single character• Chart brightness adjustability to the installation conditions• Switchable function between display and non-display of visual acuity of the chart• A long-life LED for the illumination light source HOX Chart, Visual Acuity 1 CHART PROJECTOR
46 04987669101315 11143-7300 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(23G/Coaxial)
47 04987669101087 DS-20 Control Unit NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital phot NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. DS-20 consists of control unit and optical lens DS-20F (Digital Eye Fundus Camera). PJZ Camera, Ophthalmic, General-Use 2 DIGITAL MEDICAL SCOPE
48 04987669100936 17454-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated. A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). ZEISS SL130 type is available. HQF Laser, Ophthalmic 2 Scan attachable delivery unit (SL130)
49 04987669100516 RS-3000 Advance The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera t The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera that allows non-invasive and non-contact observation of the shape of the fundus or retina. Fundus surface images (hereafter referred to as SLO image) are captured with the confocal laser scanning using a near-infrared light source with a wavelength of 785 nm. Cross-sectional images of the retina (hereafter referred to as OCT image) are captured with the optical interferometer using an infrared light source with a wavelength of 880 nm. With the images captured using the RS-3000 Advance, the shape and structure of the fundus or retina can be observed, and diseases can be observed. This system is comprised of the main body for capturing images, a computer (hereafter called PC) for storing and analyzing captured images, PC monitor, and an isolation transformer.In addition, the image filing software NAVIS-EX (hereafter referred to as NAVIS-EX) offers the following features:• Image analysis functions such as 3D/map color display or retinal thickness analysis• Networking for data review or analysis on PCs in separate locations OBO Tomography, Optical Coherence 2 OPTICAL COHERENCE TOMOGRAPHY
50 04987669100202 GYC-1000 The GREEN LASER PHOTOCOAGULATOR SYSTEM GYC-1000 is an ophthalmological photocoag The GREEN LASER PHOTOCOAGULATOR SYSTEM GYC-1000 is an ophthalmological photocoagulation system using a solid state laser (green laser beam) with a wavelength of 532nm. Like conventional laser photocoagulation systems, this system is used in ophthalmic surgical procedures, including retinal and macular photocoagulation, iridotomy and trabeculoplasty.Since the GYC-1000 uses a diode laser as its pumping light source, the efficient oscillation of the 532nm laser beam can be obtained. As the GYC-1000 can be used with various kinds of delivery units, the system can be applied to transpupillary photocoagulation using the slit lamp or indirect ophthalmoscope, and to intraocular photocoagulation using the endophotocoagulation probe. GEX Powered Laser Surgical Instrument 2 GREEN LASER PHOTOCOAGULATOR SYSTEM
Other products with the same Product Code "GEX"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04548213020911 MEY-1-A AdvErL EVO J.MORITA MFG.CORP.
2 04547497771090 Opelaser Lite Ⅱ Opelaser YOSHIDA DENTAL MFG. CO., LTD., THE
3 04547497771052 Opelaser PROⅡ Opelaser YOSHIDA DENTAL MFG. CO., LTD., THE
4 04260438610066 FT IR400/440PI-3/SM-F 500211L M250400S FiberTech® LEONI FIBER OPTICS GMBH
5 04260438610042 FT IR600T-3/SGFM-F 000021L M290800S FiberTech® LEONI FIBER OPTICS GMBH
6 04260438610035 FT IR400T-3/SGFM-F 000031L M290400S FiberTech® LEONI FIBER OPTICS GMBH
7 04260438610028 FT IR600/720HCN-3/SL-SF-2000 012011L M280300S FiberTech® LEONI FIBER OPTICS GMBH
8 04260438610011 FT IR600/660HCT-3/SL-F 130011L M240600S FiberTech® LEONI FIBER OPTICS GMBH
9 04260438610004 FT IR400/420HCT-3/SL-F 130011L M240400S FiberTech® LEONI FIBER OPTICS GMBH
10 G256SEB2503PUS1 SEB-250-3P-US SEB2503PUS Sebacia Microparticles Box of 9 vials Sebacia Microparticles CORONADO AESTHETICS, LLC
11 G050OXYLIGHT0 OXYLIGHT The OxyLight system is a skin care therapy system that that uses multiple therap The OxyLight system is a skin care therapy system that that uses multiple therapeutic modalities delivered through different attachments or handles. The system includes a panel that irradiates Blue, Red and Yellow LED light for photodynamic therapy and Oxygen spray therapy as well as a microdermabrasion handle. OXYLIGHT RAJA MEDICAL
12 EOBN270123S0 Laser Surgery Fiber - Radial Emission Fiber 600µm Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jac Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
13 EOBN270122S0 Laser Surgery Fiber - Radial Emission Fiber 400µm Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jack Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
14 EOBN270120S0 Laser Surgery Fiber - Radial Emission Fiber 600µm Vein Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefze Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
15 EOBN270119S0 Laser Surgery Fiber - Radial Emission Fiber 600µm Stopper Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, whi Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
16 EOBN270118S0 Laser Surgery Fiber - Radial Emission Fiber 400µm Vein Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
17 EOBN270117S0 Laser Surgery Fiber - Radial Emission Fiber 400µm Stopper Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, whit Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
18 EOBN270082S0 Corona 360 Radial Fiber 600µm Corona 360 Radial Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel J Corona 360 Radial Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket with length marking, customized connector, white bend protection, distal conical tip with silica capillary dome, capillary OD 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
19 EOBN270055S0 Radial Emission Fiber 400µm Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Ja Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, LUER adapter, distal conical tip with silica capillary dome, capillary OD 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
20 EOBN270029S0 Corona 360 Fiber 600µm Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket with length marking, customized connector, white bend protection, distal conical tip with silica capillary dome, capillary OD 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
21 EOBN230053S0 Laser Surgery Fiber - Chirurgie Bare Fiber 320µm NA OBERON GMBH FIBER TECHNOLOGIES
22 EOBN230052N0 Laser Surgery Fiber - Dental Bare Fiber 320µm NA OBERON GMBH FIBER TECHNOLOGIES
23 EOBN230051N0 Laser Surgery Fiber - Dental Bare Fiber 200µm NA OBERON GMBH FIBER TECHNOLOGIES
24 EOBN230031S0 Dental Surgery Fiber 320µm Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating, Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating, standard SMA 905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, Silicone tubing OD 2mm, distal flat tip, cleaved, 10cm freestanding fiber, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, single packed, NA OBERON GMBH FIBER TECHNOLOGIES
25 EOBN220126S0 Laser Surgery Fiber 600µm Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, SMA 905 holmium connector with knurl nut, PEEK protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, 3mm stripped, NA 0.22, length 3m +/-0,2m, sterile EO, double packed NA OBERON GMBH FIBER TECHNOLOGIES
26 EOBN220051S0 General Surgery Fiber 400um Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jack Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA 905 connector with knurl nut, PEEK protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, NA 0.22, length 3m +/-0,2m, sterile EO, double packed NA OBERON GMBH FIBER TECHNOLOGIES
27 EOBN210167S0 Laser Surgery Fiber 600µm Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, SMA 905 holmium connector with knurl nut, black protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, 3mm stripped, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
28 EOBN210138S0 Fiber Optic for MRI blue Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop blue 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
29 EOBN210137S0 Fiber Optic for MRI green Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop green 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
30 EOBN210136S0 Fiber Optic for MRI yellow Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop yellow 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
31 EOBN210135S0 Fiber Optic for MRI red Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop red 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
32 EOBN210117S0 Fiber Optic for PLA Long blue Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop blue 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
33 EOBN210116S0 Fiber Optic for PLA Long green Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop green 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
34 EOBN210115S0 Fiber Optic for PLA Long yellow Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop yellow 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
35 EOBN210114S0 Fiber Optic for PLA Long red Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop red 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
36 EOBN210113S0 Fiber Optic for PLA Short blue Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop blue 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
37 EOBN210112S0 Fiber Optic for PLA Short green Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop green 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
38 EOBN210111S0 Fiber Optic for PLA Short yellow Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop yellow 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
39 EOBN210110S0 Fiber Optic for PLA Short red Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop red 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
40 EOBN200029S0 Laser Surgery Fiber 600µm 2.6m Laser Surgery Fiber, core 600µm, fiber OD 950µm, transparent Tefzel Jacket, cust Laser Surgery Fiber, core 600µm, fiber OD 950µm, transparent Tefzel Jacket, customized connector, white bend protection (heat shrink tube), LUER adapter, distal flat tip, cleaved, NA 0.37, length 2,6m +/-0,2m, sterile EO, disposable, double packed NA OBERON GMBH FIBER TECHNOLOGIES
41 04260155593017 LS03200 LS03200 FOX 1064 nm Diode laser, aiming beam 532 nm, coupling 300 um Diode laser FOX 1064 nm. A.R.C. LASER GMBH
42 04260155592546 LS11000 LS11000 Wolf 445nm, Diode Laser, Aiming Beam 532nm, Coupling U.C. Diode Laser Wolf 445nm A.R.C. LASER GMBH
43 04260155592317 LL28068s LL28068s HiFlex Fiber, 600 micrometers, Universal Centering Laser Surgery Fibers and Probes A.R.C. LASER GMBH
44 04260155592225 LL28062s LL28062s HiFlex Fiber, 300 micrometer, Universal Centering Laser Surgery Fibers and Probes A.R.C. LASER GMBH
45 04260155592126 LL13062s LL13062s HiFlex Fiber, 300 micrometer Laser Surgery Fibers and Probes A.R.C. LASER GMBH
46 04260155591976 LL28066s LL28066s HiFlex Fiber, 400 micrometer, Universal Centering Laser Surgery Fibers and Probes A.R.C. LASER GMBH
47 04260155591945 LL13066s LL13066s HiFlex Fiber, 400 micrometer Laser Surgery Fibers and Probes A.R.C. LASER GMBH
48 04260155591518 LL28059s LL28059s Otology probe curved tip 20° universal centering Laser Surgery Fibers and Probes A.R.C. LASER GMBH
49 04260155591501 LL28058s LL28058s Otology probe long universal centering Laser Surgery Fibers and Probes A.R.C. LASER GMBH
50 04260155591495 LL28006s LL28006s Bare fiber 400 micrometer universal centering 1470 nm Laser Surgery Fibers and Probes A.R.C. LASER GMBH