No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 04987669101421 | 1.0 | Data Acquisition Service for NAVIS-EX (hereafter referred to as DAS) acquires da Data Acquisition Service for NAVIS-EX (hereafter referred to as DAS) acquires data from measurement devices and transfers it to NAVIS-EX.In addition to acquisition of measurement data, DAS registers patients newly registered with the ALScan/CEM-530 to NAVIS-EX. | NFJ | System, Image Management, Ophthalmic | 2 | Data Acquisition Service for NAVIS-EX | |
2 | 04987669101360 | 1.1 | The AL-Scan Viewer for NAVIS-EX software (hereafter referred to as AL-Scan Viewe The AL-Scan Viewer for NAVIS-EX software (hereafter referred to as AL-Scan Viewer) is used to handle the AL-Scan data within NAVIS-EX. This function is added to the computer as a plug-in for NAVISEX. The measured value data and waveform can be displayed, the IOL power can be calculated, andthe toric lens assist data can be created. The AL-Scan data is imported to NAVIS-EX using separate software, Data Acquisition Service. | NFJ | System, Image Management, Ophthalmic | 2 | AL-Scan Viewer for NAVIS-EX | |
3 | 04987669101322 | 11143-7500 | It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. | GEX | Powered Laser Surgical Instrument | 2 | Sterilized Endophoto Probe(25G/Coaxial) | |
4 | 04987669101292 | 11143-6700 | It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. | GEX | Powered Laser Surgical Instrument | 2 | Sterilized Endophoto Probe(27G/Straight) | |
5 | 04987669101285 | 11143-6600 | It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. | GEX | Powered Laser Surgical Instrument | 2 | Sterilized Endophoto Probe(25G/Angled) | |
6 | 04987669101124 | GDA01 | The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.*1 Safety Optics with Low Impact on Cornea | HQF | Laser, Ophthalmic | 2 | Attachable delivery unit (SL130) | |
7 | 04987669100899 | 17434-0000 | The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system.ZEISS SL130 type is available. | HQF | Laser, Ophthalmic | 2 | Attachable delivery unit (SL130) | |
8 | 04987669100851 | GYC-500 | The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for oph The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for ophthalmology using a 532 nm diode-pumped solid-state laser (green laser beam) as the treatment beam source. The device incorporates a diode-pumped laser that enables efficient laser beam emission at 532 nm. For the laser beam delivery, various types of delivery units may be employed. This allows performance of transpupillary photocoagulation using a slit lamp or binocular indirect ophthalmoscope. | HQF | Laser, Ophthalmic | 2 | Green Laser Photocoagulator | |
9 | 04987669100776 | OPD-Scan III | The NIDEK refractive power / corneal analyzer OPD-Scan III (hereafter referred t The NIDEK refractive power / corneal analyzer OPD-Scan III (hereafter referred to as “the device”) measures objective refractive error, corneal curvature, shape of the anterior corneal surface (topography), and pupil size of the patient’s eye, and analyzes wavefront aberration. The measured refractive error can be used for reference when prescribing corrective lenses such as glasses or contact lenses. | HLQ,HKO | Keratoscope, Ac-Powered,Refractometer, Ophthalmic | 1 | REFRACTIVE POWER / CORNEAL ANALYZER | |
10 | 04987669100561 | F-10 | The F-10 captures and records the confocal images of fundus by laser scanning us The F-10 captures and records the confocal images of fundus by laser scanning using a selection of laser colors: IR (infrared), blue, green, and red. Indocyanine green (ICG) angiography and fluorescein angiography (FAG) are also possible. | MYC | Ophthalmoscope, Laser, Scanning | 2 | OPHTHALMOSCOPE | |
11 | 04987669100523 | NAVIS-EX | The NAVIS-EX image filing software is software that acquires data from the follo The NAVIS-EX image filing software is software that acquires data from the following NIDEK fundus photography devices and files it for easy transfer to external systems. NAVIS-EX is equipped with functions for image acquiring, image display, image drawing, image processing, image measurement, panorama image creation, stereo image observation, composite image creation, and Follow-Up. (According to the image, available functions are limited.) Image data can be transferred by network or e-mail. NAVIS-EX can construct a network among multiple terminals and refers to and edits data from the clientPC. | NFG,NFF,MYC,HKI,HPT,OBO,HJO,NFJ | Device, Communications, Images, Ophthalmic,Device, Storage, Images, Ophthalmic,O Device, Communications, Images, Ophthalmic,Device, Storage, Images, Ophthalmic,Ophthalmoscope,Laser,Scanning,Camera, Ophthalmic, Ac-Powered,Perimeter, Automatic, Ac-Powered,Tomography, Optical Coherence,Biomicroscope, Slit-Lamp, Ac-Powered,System, Image Management, Ophthalmic | 1 | Image filing software | |
12 | 04987669100011 | EC-5000 | NIDEK EXCIMER LASER CORNEAL SURGERY SYSTEM, model EC-5000CXIII, is an ophthalmic NIDEK EXCIMER LASER CORNEAL SURGERY SYSTEM, model EC-5000CXIII, is an ophthalmic laser system used for correction of corneal refraction and ablation of the corneal surface. The system is composed of a laser generator which produces an excimer laser radiation of wavelength193nm, a beam delivery unit, an optical system for observation, a gas system, and a computer for system control. The system is designed to be user friendly for easy and safe operation with NIDEK’s advanced optoelectronic technology. | LZS | Excimer Laser System | 3 | NA | |
13 | 04987669101414 | TS-310 | The TS-310 is a space-saving automated refraction system that uses a combination The TS-310 is a space-saving automated refraction system that uses a combination of the refractor head of the RT-3100 and a control box.• With the high precision LCD, visual acuity of 5 m as well as near visual acuity of 40 cm can be measured with the same accuracy as a standard refraction using actual distances.• The objective data measured by a NIDEK auto refractometer and the lensometry data measured by a NIDEK lensmeter can be imported and used in this device. | HKN,HOX | Refractor, Manual, Non-Powered, Including Phoropter,Chart, Visual Acuity | 1 | Tabletop Refraction System | |
14 | 04987669101346 | 1.13 | The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) | LZS | Excimer Laser System | 3 | Final Fit | |
15 | 04987669101247 | 11143-6200 | It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. | GEX | Powered Laser Surgical Instrument | 2 | Sterilized Endophoto Probe(20G/Angled) | |
16 | 04987669101131 | GDB01 | The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated.*1 Safety Optics with Low Impact on Cornea | HQF | Laser, Ophthalmic | 2 | Slit lamp delivery unit (NIDEK SL) | |
17 | 04987669101117 | YLC-500 | The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagu The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagulator consisting of a main laser device, a control box, and a power supply. With various types of laser delivery units, it comprises a photocoagulation system. The YLC-500 uses a 577 nm optically pumped semiconductor laser (yellow laser beam) as the treatment beam source. The pumped yellow laser beam (treatment beam) and the aiming beam (635 nm, red laser beam) are fed coaxially into the fiber optic cable. The output terminal of the fiber optic cable is connected to a delivery unit. The laser beam is formed into the desired spot size by the optical system, then the laser beam is emitted to the target area. The delivery units are equipped with a protective filter that protects the physician’s eyes from exposure to the treatment beam reflected from the patient’s eye or contact lens. | HQF | Laser, Ophthalmic | 2 | Yellow Laser Photocoagulator | |
18 | 04987669100301 | 17118-0000 | This Endophotocoagulation Delivery Unit is used for endophotocoagulation. The de This Endophotocoagulation Delivery Unit is used for endophotocoagulation. The delivery unit is comprised of an endophoto probe, a relay adapter, a protective filter unit, and a carrying case. The photocoagulation laser system can be easily formed by connecting the endophoto probe to theGREEN LASER PHOTOCOAGULATOR Model GYC-1000 main body and connecting the protective filter to the GYC-1000 main body and the surgical microscope. This photocoagulation laser system enables endophotocoagulation with the green laser (wavelength: 532 nm) while observing theaffected area through the surgical microscope. This delivery unit is intended to be used with the protective filter unit attached to surgical microscopes. NIDEK provides following four types of delivery units according to the types of protective filters and the surgical microscopes*1.Before use, check the type of your surgical microscope and delivery unit. | GEX | Powered Laser Surgical Instrument | 2 | Endophotocoagulation delivery unit | |
19 | 04987669100066 | TONOREF II | AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objecti AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objective refraction, corneal shape measurement, and non-contact tonometry measurement by incorporating a standard auto ref/keratometer and non-contact tonometer into one unit. The objective refraction function measures spherical powers, cylindrical powers and cylinder axis. The corneal shape measurement function measures the radius of corneal curvature (corneal refractive powers), the direction of the steepest meridian, and the amount of corneal astigmatism. The non-contact tonometry function measures the intraocular pressure without contacting the eye. | HKX,HKO,HLQ | Tonometer, Ac-Powered,Refractometer, Ophthalmic,Keratoscope, Ac-Powered | 1 | AUTO REF/KERATO/TONOMETER | |
20 | 04987669100042 | 1.12 | The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) | LZS | Excimer Laser System | 3 | Final Fit™ | |
21 | 04987669100035 | 1.11US | The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) | LZS | Excimer Laser System | 3 | Final Fit™ | |
22 | 04987669101575 | CP-9 | The Nidek CHART PROJECTOR CP-9 is a chart presenting device that can achieve ref The Nidek CHART PROJECTOR CP-9 is a chart presenting device that can achieve refraction at a distance of 2.9 m to 6.1 m (standard 5 m).The main unit is operated by a wireless remote control or the control box on a motorized refractor (RT). | HOX | Chart, Visual Acuity | 1 | CHART PROJECTOR | |
23 | 04987669101452 | YC-200 | The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system cons The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system consisting of a main body containing the laser, a head rest, a control box, and a connector box. The device uses a 1,064 nm pulsed Nd: YAG laser as the treatment beam source. Laser pulses are generated using a method called passive Q-switching. With this method, short high-power pulses can be emitted. At the target, the emitted pulses cause photodisruption, which is fragmentation of tissue using light energy. | HQF,HJO | Laser, Ophthalmic,Biomicroscope, Slit-Lamp, Ac-Powered | 2 | Ophthalmic YAG Laser System | |
24 | 04987669101049 | DS-10G | DS-10G is a digital hand-held camera used to record digital photographs and vide DS-10G is a digital hand-held camera used to record digital photographs and video of the human body. | FXF | Speculum, Illuminated | 1 | DIGITAL MEDICAL SCOPE | |
25 | 04987669101001 | DS-20F | NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital phot NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. | PJZ | Camera, Ophthalmic, General-Use | 2 | DIGITAL MEDICAL SCOPE | |
26 | 04987669100967 | 17166-6100 | Expansion box is the optional accessory that is used to connect a scan delivery Expansion box is the optional accessory that is used to connect a scan delivery unit and the external devices (LAN cable, barcode scanner, or magnetic card reader) to the GYC-500. | HQF | Laser, Ophthalmic | 2 | Expansion box | |
27 | 04987669101377 | SL-2000 | The NIDEK SLIT LAMP SL-2000 is used to magnify the eyeball, eyelid, and eyelash The NIDEK SLIT LAMP SL-2000 is used to magnify the eyeball, eyelid, and eyelash of patients for observation, using slit illumination light. | HJO | Biomicroscope, Slit-Lamp, Ac-Powered | 2 | Slit Lamp | |
28 | 04987669101032 | DS-10E | DS-10E is a digital hand-held otoscope used to record digital photographs and vi DS-10E is a digital hand-held otoscope used to record digital photographs and video of the human ear’s canal and tympanic membrane. | ERA | Otoscope | 1 | DIGITAL MEDICAL SCOPE | |
29 | 04987669100998 | DS-10F | NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital pho NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. | HKI | Camera, Ophthalmic, Ac-Powered | 2 | DIGITAL MEDICAL SCOPE | |
30 | 04987669101179 | GEA01 | The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). The ZEISS SL130 type is available: *1 Safety Optics with Low Impact on Cornea | HQF | Laser, Ophthalmic | 2 | Scan Attachable delivery unit (SL130) | |
31 | 04987669101070 | DS-10 Control Unit | The assembly system (control unit & DS-10EA Adapter & existing endoscope in the The assembly system (control unit & DS-10EA Adapter & existing endoscope in the market) can be used to record digital photographs and video ofthe body. | FTT,ERA,FSP,FXF,HKI | Camera, Still, Surgical,Otoscope,Loupe, Diagnostic/Surgical,Speculum, Illuminate Camera, Still, Surgical,Otoscope,Loupe, Diagnostic/Surgical,Speculum, Illuminated,Camera, Ophthalmic, Ac-Powered | 1 | DIGITAL MEDICAL SCOPE | |
32 | 04987669101056 | DS-10EA | DS-10EA Adapter is designed to connect the control unit of DS-10 and the existin DS-10EA Adapter is designed to connect the control unit of DS-10 and the existing endoscope in the market. The assembly system (control unit & DS-10EA Adapter & existing endoscope in the market) can be used to record digital photographs and video of the body. | FTT | Camera, Still, Surgical | 1 | DIGITAL MEDICAL SCOPE | |
33 | 04987669101025 | DS-10D | DS-10D is a digital hand-held dermatoscope used to record digital photographs an DS-10D is a digital hand-held dermatoscope used to record digital photographs and video of the human skin. | FSP | Loupe, Diagnostic/Surgical | 1 | DIGITAL MEDICAL SCOPE | |
34 | 04987669101018 | DS-10A | DS-10A is a digital hand-held anterior scope used to record digital photographs DS-10A is a digital hand-held anterior scope used to record digital photographs and video of anterior area of the human eye and surrounding area. | FXF | Speculum, Illuminated | 1 | DIGITAL MEDICAL SCOPE | |
35 | 04987669100905 | 17441-0000 | The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. HAAG 900 series type is available. | HQF | Laser, Ophthalmic | 2 | Attachable delivery unit (900BQ) | |
36 | 04987669100882 | 17432-0000 | The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. NIDEK SL-1800 type is available. | HQF | Laser, Ophthalmic | 2 | Attachable delivery unit (SL-1800) | |
37 | 04987669100875 | 17431-0000 | The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. The ZEISS 30 SL type is availabe. | HQF | Laser, Ophthalmic | 2 | Attachable delivery unit (30SL/M) | |
38 | 04987669100837 | PM-700 | The PD meter model PM-700 is a pupillary distance meter improved with a built-in The PD meter model PM-700 is a pupillary distance meter improved with a built-in computer and LCD digital display. | HLG | Pupillometer, Ac-Powered | 1 | PD Meter | |
39 | 04987669100431 | NT-530 | The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry mea The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology. | HKX | Tonometer, Ac-Powered | 2 | NON CONTACT TONOMETER | |
40 | 04987669100424 | NT-510 | The NON CONTACT TONOMETER Model NT-510 is designed for non-contact tonometry mea The NON CONTACT TONOMETER Model NT-510 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology. | HKX | Tonometer, Ac-Powered | 2 | NON CONTACT TONOMETER | |
41 | 04987669100288 | 17112-0000 | This unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC- 1000 This unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC- 1000 (main body) to comprise the photocoagulation system and applied to the treatment of the affected area using the B.I.O. delivery unit (HEINE OMEGA 500). The comprised photocoagulation system makes it possible to switch between photocoagulation with the green laser beam (wavelength: 532 nm) and observation with the B.I.O. | GEX | Powered Laser Surgical Instrument | 2 | BIO delivery unit (Heine OMEGA) | |
42 | 04987669100233 | 17402-0000 | This delivery unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model This delivery unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC-1000 (main body) to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800. The integrated delivery unit which incorporates the SL-1800 comprises the photocoagulation system in connection with the GYC-1000 main body. The attachable delivery unit is mainly the photocoagulation unit and the protective filter unit. They are attached to your slit lamp (NIDEK SL-1800) to comprise the integrated delivery unit. The comprisedintegrated delivery is connected to the GYC-1000 to comprise the photocoagulation system. This photocoagulation system allows the operator to select between photocoagulation with the green laser beam (wavelength: 532 nm) and observation of the affected area with the slit lamp. | GEX | Powered Laser Surgical Instrument | 2 | Attachable delivery unit (SL-1800) | |
43 | 04987669100134 | 17462-0000 | This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body. A attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit.They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a slit lamp delivery unit. The comprised slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. | HQF | Laser, Ophthalmic | 2 | Attachable delivery unit (SL-1800) | |
44 | 04987669100080 | MC-500 | The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for ophthalmology with the light source of wavelengths 647, 577, and 532 nm. As the conventional laser photocoagulators, the MC-500 can be used for retinal photocoagulation for treatment of ocular fundus diseases like diabetic retinopathy, age-related macular degeneration, retinopathy of prematurity, and retinal detachment, or for laser iridotomy and laser trabeculoplasty for treatment of glaucoma. The device incorporates two types of lasers (diode-pumped solid state laser and laser diode) which enable efficient obtainment of laser beam oscillation of each wavelength. As the conventional device, various types of laser delivery units can be used. Therefore, transpupillary photocoagulation can be performed using various delivery units such as slit lamps and binocular indirect ophthalmoscope. | HQF | Laser, Ophthalmic | 2 | Multicolor Laser Photocoagulator | |
45 | 04987669100059 | CP-770 | The NIDEK Chart Projector CP-770 is a test chart presenting device which can ach The NIDEK Chart Projector CP-770 is a test chart presenting device which can achieve refraction distance from 2.9 m to 6.1 m. The device is controlled by a wireless remote control or a control box on the refractor (RT).The CP-770 features the following:• Equipped with 33 types of charts (27 types for Type UK) including various kinds of binocular charts• Program function that allows chart presentation with the touch of a button• Versatile masking function that can even offer the display of even a single character• Chart brightness adjustability to the installation conditions• Switchable function between display and non-display of visual acuity of the chart• A long-life LED for the illumination light source | HOX | Chart, Visual Acuity | 1 | CHART PROJECTOR | |
46 | 04987669101315 | 11143-7300 | It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. | GEX | Powered Laser Surgical Instrument | 2 | Sterilized Endophoto Probe(23G/Coaxial) | |
47 | 04987669101087 | DS-20 Control Unit | NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital phot NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. DS-20 consists of control unit and optical lens DS-20F (Digital Eye Fundus Camera). | PJZ | Camera, Ophthalmic, General-Use | 2 | DIGITAL MEDICAL SCOPE | |
48 | 04987669100936 | 17454-0000 | The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated. A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). ZEISS SL130 type is available. | HQF | Laser, Ophthalmic | 2 | Scan attachable delivery unit (SL130) | |
49 | 04987669100516 | RS-3000 Advance | The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera t The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera that allows non-invasive and non-contact observation of the shape of the fundus or retina. Fundus surface images (hereafter referred to as SLO image) are captured with the confocal laser scanning using a near-infrared light source with a wavelength of 785 nm. Cross-sectional images of the retina (hereafter referred to as OCT image) are captured with the optical interferometer using an infrared light source with a wavelength of 880 nm. With the images captured using the RS-3000 Advance, the shape and structure of the fundus or retina can be observed, and diseases can be observed. This system is comprised of the main body for capturing images, a computer (hereafter called PC) for storing and analyzing captured images, PC monitor, and an isolation transformer.In addition, the image filing software NAVIS-EX (hereafter referred to as NAVIS-EX) offers the following features:• Image analysis functions such as 3D/map color display or retinal thickness analysis• Networking for data review or analysis on PCs in separate locations | OBO | Tomography, Optical Coherence | 2 | OPTICAL COHERENCE TOMOGRAPHY | |
50 | 04987669100202 | GYC-1000 | The GREEN LASER PHOTOCOAGULATOR SYSTEM GYC-1000 is an ophthalmological photocoag The GREEN LASER PHOTOCOAGULATOR SYSTEM GYC-1000 is an ophthalmological photocoagulation system using a solid state laser (green laser beam) with a wavelength of 532nm. Like conventional laser photocoagulation systems, this system is used in ophthalmic surgical procedures, including retinal and macular photocoagulation, iridotomy and trabeculoplasty.Since the GYC-1000 uses a diode laser as its pumping light source, the efficient oscillation of the 532nm laser beam can be obtained. As the GYC-1000 can be used with various kinds of delivery units, the system can be applied to transpupillary photocoagulation using the slit lamp or indirect ophthalmoscope, and to intraocular photocoagulation using the endophotocoagulation probe. | GEX | Powered Laser Surgical Instrument | 2 | GREEN LASER PHOTOCOAGULATOR SYSTEM |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 04548213020911 | MEY-1-A | AdvErL EVO | J.MORITA MFG.CORP. | ||
2 | 04547497771090 | Opelaser Lite Ⅱ | Opelaser | YOSHIDA DENTAL MFG. CO., LTD., THE | ||
3 | 04547497771052 | Opelaser PROⅡ | Opelaser | YOSHIDA DENTAL MFG. CO., LTD., THE | ||
4 | 04260438610066 | FT IR400/440PI-3/SM-F 500211L | M250400S | FiberTech® | LEONI FIBER OPTICS GMBH | |
5 | 04260438610042 | FT IR600T-3/SGFM-F 000021L | M290800S | FiberTech® | LEONI FIBER OPTICS GMBH | |
6 | 04260438610035 | FT IR400T-3/SGFM-F 000031L | M290400S | FiberTech® | LEONI FIBER OPTICS GMBH | |
7 | 04260438610028 | FT IR600/720HCN-3/SL-SF-2000 012011L | M280300S | FiberTech® | LEONI FIBER OPTICS GMBH | |
8 | 04260438610011 | FT IR600/660HCT-3/SL-F 130011L | M240600S | FiberTech® | LEONI FIBER OPTICS GMBH | |
9 | 04260438610004 | FT IR400/420HCT-3/SL-F 130011L | M240400S | FiberTech® | LEONI FIBER OPTICS GMBH | |
10 | G256SEB2503PUS1 | SEB-250-3P-US | SEB2503PUS | Sebacia Microparticles Box of 9 vials | Sebacia Microparticles | CORONADO AESTHETICS, LLC |
11 | G050OXYLIGHT0 | OXYLIGHT | The OxyLight system is a skin care therapy system that that uses multiple therap The OxyLight system is a skin care therapy system that that uses multiple therapeutic modalities delivered through different attachments or handles. The system includes a panel that irradiates Blue, Red and Yellow LED light for photodynamic therapy and Oxygen spray therapy as well as a microdermabrasion handle. | OXYLIGHT | RAJA MEDICAL | |
12 | EOBN270123S0 | Laser Surgery Fiber - Radial Emission Fiber 600µm | Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jac Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
13 | EOBN270122S0 | Laser Surgery Fiber - Radial Emission Fiber 400µm | Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jack Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
14 | EOBN270120S0 | Laser Surgery Fiber - Radial Emission Fiber 600µm Vein | Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefze Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
15 | EOBN270119S0 | Laser Surgery Fiber - Radial Emission Fiber 600µm Stopper | Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, whi Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
16 | EOBN270118S0 | Laser Surgery Fiber - Radial Emission Fiber 400µm Vein | Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
17 | EOBN270117S0 | Laser Surgery Fiber - Radial Emission Fiber 400µm Stopper | Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, whit Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
18 | EOBN270082S0 | Corona 360 Radial Fiber 600µm | Corona 360 Radial Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel J Corona 360 Radial Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket with length marking, customized connector, white bend protection, distal conical tip with silica capillary dome, capillary OD 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
19 | EOBN270055S0 | Radial Emission Fiber 400µm | Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Ja Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, LUER adapter, distal conical tip with silica capillary dome, capillary OD 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
20 | EOBN270029S0 | Corona 360 Fiber 600µm | Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket with length marking, customized connector, white bend protection, distal conical tip with silica capillary dome, capillary OD 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
21 | EOBN230053S0 | Laser Surgery Fiber - Chirurgie Bare Fiber 320µm | NA | OBERON GMBH FIBER TECHNOLOGIES | ||
22 | EOBN230052N0 | Laser Surgery Fiber - Dental Bare Fiber 320µm | NA | OBERON GMBH FIBER TECHNOLOGIES | ||
23 | EOBN230051N0 | Laser Surgery Fiber - Dental Bare Fiber 200µm | NA | OBERON GMBH FIBER TECHNOLOGIES | ||
24 | EOBN230031S0 | Dental Surgery Fiber 320µm | Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating, Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating, standard SMA 905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, Silicone tubing OD 2mm, distal flat tip, cleaved, 10cm freestanding fiber, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, single packed, | NA | OBERON GMBH FIBER TECHNOLOGIES | |
25 | EOBN220126S0 | Laser Surgery Fiber 600µm | Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, SMA 905 holmium connector with knurl nut, PEEK protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, 3mm stripped, NA 0.22, length 3m +/-0,2m, sterile EO, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
26 | EOBN220051S0 | General Surgery Fiber 400um | Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jack Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA 905 connector with knurl nut, PEEK protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, NA 0.22, length 3m +/-0,2m, sterile EO, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
27 | EOBN210167S0 | Laser Surgery Fiber 600µm | Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, SMA 905 holmium connector with knurl nut, black protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, 3mm stripped, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
28 | EOBN210138S0 | Fiber Optic for MRI blue | Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop blue 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
29 | EOBN210137S0 | Fiber Optic for MRI green | Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop green 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
30 | EOBN210136S0 | Fiber Optic for MRI yellow | Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop yellow 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
31 | EOBN210135S0 | Fiber Optic for MRI red | Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420 Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop red 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
32 | EOBN210117S0 | Fiber Optic for PLA Long blue | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop blue 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
33 | EOBN210116S0 | Fiber Optic for PLA Long green | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop green 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
34 | EOBN210115S0 | Fiber Optic for PLA Long yellow | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop yellow 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
35 | EOBN210114S0 | Fiber Optic for PLA Long red | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop red 239mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
36 | EOBN210113S0 | Fiber Optic for PLA Short blue | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop blue 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
37 | EOBN210112S0 | Fiber Optic for PLA Short green | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop green 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
38 | EOBN210111S0 | Fiber Optic for PLA Short yellow | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop yellow 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
39 | EOBN210110S0 | Fiber Optic for PLA Short red | Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 42 Fiber Probe for Percutaneous Laser Ablation, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, PVC protection cap, extension sleeve silver, fiber stop red 144mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 2m +/-0,02m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
40 | EOBN200029S0 | Laser Surgery Fiber 600µm 2.6m | Laser Surgery Fiber, core 600µm, fiber OD 950µm, transparent Tefzel Jacket, cust Laser Surgery Fiber, core 600µm, fiber OD 950µm, transparent Tefzel Jacket, customized connector, white bend protection (heat shrink tube), LUER adapter, distal flat tip, cleaved, NA 0.37, length 2,6m +/-0,2m, sterile EO, disposable, double packed | NA | OBERON GMBH FIBER TECHNOLOGIES | |
41 | 04260155593017 | LS03200 | LS03200 | FOX 1064 nm Diode laser, aiming beam 532 nm, coupling 300 um | Diode laser FOX 1064 nm. | A.R.C. LASER GMBH |
42 | 04260155592546 | LS11000 | LS11000 | Wolf 445nm, Diode Laser, Aiming Beam 532nm, Coupling U.C. | Diode Laser Wolf 445nm | A.R.C. LASER GMBH |
43 | 04260155592317 | LL28068s | LL28068s | HiFlex Fiber, 600 micrometers, Universal Centering | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |
44 | 04260155592225 | LL28062s | LL28062s | HiFlex Fiber, 300 micrometer, Universal Centering | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |
45 | 04260155592126 | LL13062s | LL13062s | HiFlex Fiber, 300 micrometer | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |
46 | 04260155591976 | LL28066s | LL28066s | HiFlex Fiber, 400 micrometer, Universal Centering | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |
47 | 04260155591945 | LL13066s | LL13066s | HiFlex Fiber, 400 micrometer | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |
48 | 04260155591518 | LL28059s | LL28059s | Otology probe curved tip 20° universal centering | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |
49 | 04260155591501 | LL28058s | LL28058s | Otology probe long universal centering | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |
50 | 04260155591495 | LL28006s | LL28006s | Bare fiber 400 micrometer universal centering 1470 nm | Laser Surgery Fibers and Probes | A.R.C. LASER GMBH |