Other products from "NIDEK CO.,LTD."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04987669101421 1.0 Data Acquisition Service for NAVIS-EX (hereafter referred to as DAS) acquires da Data Acquisition Service for NAVIS-EX (hereafter referred to as DAS) acquires data from measurement devices and transfers it to NAVIS-EX.In addition to acquisition of measurement data, DAS registers patients newly registered with the ALScan/CEM-530 to NAVIS-EX. NFJ System, Image Management, Ophthalmic 2 Data Acquisition Service for NAVIS-EX
2 04987669101360 1.1 The AL-Scan Viewer for NAVIS-EX software (hereafter referred to as AL-Scan Viewe The AL-Scan Viewer for NAVIS-EX software (hereafter referred to as AL-Scan Viewer) is used to handle the AL-Scan data within NAVIS-EX. This function is added to the computer as a plug-in for NAVISEX. The measured value data and waveform can be displayed, the IOL power can be calculated, andthe toric lens assist data can be created. The AL-Scan data is imported to NAVIS-EX using separate software, Data Acquisition Service. NFJ System, Image Management, Ophthalmic 2 AL-Scan Viewer for NAVIS-EX
3 04987669101322 11143-7500 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(25G/Coaxial)
4 04987669101292 11143-6700 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(27G/Straight)
5 04987669101285 11143-6600 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(25G/Angled)
6 04987669101124 GDA01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.*1 Safety Optics with Low Impact on Cornea HQF Laser, Ophthalmic 2 Attachable delivery unit (SL130)
7 04987669100899 17434-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system.ZEISS SL130 type is available. HQF Laser, Ophthalmic 2 Attachable delivery unit (SL130)
8 04987669100851 GYC-500 The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for oph The NIDEK Green Laser Photocoagulator GYC-500 is a laser photocoagulator for ophthalmology using a 532 nm diode-pumped solid-state laser (green laser beam) as the treatment beam source. The device incorporates a diode-pumped laser that enables efficient laser beam emission at 532 nm. For the laser beam delivery, various types of delivery units may be employed. This allows performance of transpupillary photocoagulation using a slit lamp or binocular indirect ophthalmoscope. HQF Laser, Ophthalmic 2 Green Laser Photocoagulator
9 04987669100776 OPD-Scan III The NIDEK refractive power / corneal analyzer OPD-Scan III (hereafter referred t The NIDEK refractive power / corneal analyzer OPD-Scan III (hereafter referred to as “the device”) measures objective refractive error, corneal curvature, shape of the anterior corneal surface (topography), and pupil size of the patient’s eye, and analyzes wavefront aberration. The measured refractive error can be used for reference when prescribing corrective lenses such as glasses or contact lenses. HLQ,HKO Keratoscope, Ac-Powered,Refractometer, Ophthalmic 1 REFRACTIVE POWER / CORNEAL ANALYZER
10 04987669100561 F-10 The F-10 captures and records the confocal images of fundus by laser scanning us The F-10 captures and records the confocal images of fundus by laser scanning using a selection of laser colors: IR (infrared), blue, green, and red. Indocyanine green (ICG) angiography and fluorescein angiography (FAG) are also possible. MYC Ophthalmoscope, Laser, Scanning 2 OPHTHALMOSCOPE
11 04987669100523 NAVIS-EX The NAVIS-EX image filing software is software that acquires data from the follo The NAVIS-EX image filing software is software that acquires data from the following NIDEK fundus photography devices and files it for easy transfer to external systems. NAVIS-EX is equipped with functions for image acquiring, image display, image drawing, image processing, image measurement, panorama image creation, stereo image observation, composite image creation, and Follow-Up. (According to the image, available functions are limited.) Image data can be transferred by network or e-mail. NAVIS-EX can construct a network among multiple terminals and refers to and edits data from the clientPC. NFG,NFF,MYC,HKI,HPT,OBO,HJO,NFJ Device, Communications, Images, Ophthalmic,Device, Storage, Images, Ophthalmic,O Device, Communications, Images, Ophthalmic,Device, Storage, Images, Ophthalmic,Ophthalmoscope,Laser,Scanning,Camera, Ophthalmic, Ac-Powered,Perimeter, Automatic, Ac-Powered,Tomography, Optical Coherence,Biomicroscope, Slit-Lamp, Ac-Powered,System, Image Management, Ophthalmic 1 Image filing software
12 04987669100011 EC-5000 NIDEK EXCIMER LASER CORNEAL SURGERY SYSTEM, model EC-5000CXIII, is an ophthalmic NIDEK EXCIMER LASER CORNEAL SURGERY SYSTEM, model EC-5000CXIII, is an ophthalmic laser system used for correction of corneal refraction and ablation of the corneal surface. The system is composed of a laser generator which produces an excimer laser radiation of wavelength193nm, a beam delivery unit, an optical system for observation, a gas system, and a computer for system control. The system is designed to be user friendly for easy and safe operation with NIDEK’s advanced optoelectronic technology. LZS Excimer Laser System 3 NA
13 04987669101414 TS-310 The TS-310 is a space-saving automated refraction system that uses a combination The TS-310 is a space-saving automated refraction system that uses a combination of the refractor head of the RT-3100 and a control box.• With the high precision LCD, visual acuity of 5 m as well as near visual acuity of 40 cm can be measured with the same accuracy as a standard refraction using actual distances.• The objective data measured by a NIDEK auto refractometer and the lensometry data measured by a NIDEK lensmeter can be imported and used in this device. HKN,HOX Refractor, Manual, Non-Powered, Including Phoropter,Chart, Visual Acuity 1 Tabletop Refraction System
14 04987669101346 1.13 The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) LZS Excimer Laser System 3 Final Fit
15 04987669101247 11143-6200 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(20G/Angled)
16 04987669101131 GDB01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated.*1 Safety Optics with Low Impact on Cornea HQF Laser, Ophthalmic 2 Slit lamp delivery unit (NIDEK SL)
17 04987669101117 YLC-500 The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagu The NIDEK YELLOW LASER PHOTOCOAGULATOR YLC-500 is an ophthalmic laser photocoagulator consisting of a main laser device, a control box, and a power supply. With various types of laser delivery units, it comprises a photocoagulation system. The YLC-500 uses a 577 nm optically pumped semiconductor laser (yellow laser beam) as the treatment beam source. The pumped yellow laser beam (treatment beam) and the aiming beam (635 nm, red laser beam) are fed coaxially into the fiber optic cable. The output terminal of the fiber optic cable is connected to a delivery unit. The laser beam is formed into the desired spot size by the optical system, then the laser beam is emitted to the target area. The delivery units are equipped with a protective filter that protects the physician’s eyes from exposure to the treatment beam reflected from the patient’s eye or contact lens. HQF Laser, Ophthalmic 2 Yellow Laser Photocoagulator
18 04987669100301 17118-0000 This Endophotocoagulation Delivery Unit is used for endophotocoagulation. The de This Endophotocoagulation Delivery Unit is used for endophotocoagulation. The delivery unit is comprised of an endophoto probe, a relay adapter, a protective filter unit, and a carrying case. The photocoagulation laser system can be easily formed by connecting the endophoto probe to theGREEN LASER PHOTOCOAGULATOR Model GYC-1000 main body and connecting the protective filter to the GYC-1000 main body and the surgical microscope. This photocoagulation laser system enables endophotocoagulation with the green laser (wavelength: 532 nm) while observing theaffected area through the surgical microscope. This delivery unit is intended to be used with the protective filter unit attached to surgical microscopes. NIDEK provides following four types of delivery units according to the types of protective filters and the surgical microscopes*1.Before use, check the type of your surgical microscope and delivery unit. GEX Powered Laser Surgical Instrument 2 Endophotocoagulation delivery unit
19 04987669100066 TONOREF II AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objecti AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objective refraction, corneal shape measurement, and non-contact tonometry measurement by incorporating a standard auto ref/keratometer and non-contact tonometer into one unit. The objective refraction function measures spherical powers, cylindrical powers and cylinder axis. The corneal shape measurement function measures the radius of corneal curvature (corneal refractive powers), the direction of the steepest meridian, and the amount of corneal astigmatism. The non-contact tonometry function measures the intraocular pressure without contacting the eye. HKX,HKO,HLQ Tonometer, Ac-Powered,Refractometer, Ophthalmic,Keratoscope, Ac-Powered 1 AUTO REF/KERATO/TONOMETER
20 04987669100042 1.12 The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) LZS Excimer Laser System 3 Final Fit™
21 04987669100035 1.11US The Final Fit software receives the measured data from the Refractive Power/Corn The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data) LZS Excimer Laser System 3 Final Fit™
22 04987669101575 CP-9 The Nidek CHART PROJECTOR CP-9 is a chart presenting device that can achieve ref The Nidek CHART PROJECTOR CP-9 is a chart presenting device that can achieve refraction at a distance of 2.9 m to 6.1 m (standard 5 m).The main unit is operated by a wireless remote control or the control box on a motorized refractor (RT). HOX Chart, Visual Acuity 1 CHART PROJECTOR
23 04987669101452 YC-200 The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system cons The OPHTHALMIC YAG LASER SYSTEM YC-200 is an ophthalmic pulsed-laser system consisting of a main body containing the laser, a head rest, a control box, and a connector box. The device uses a 1,064 nm pulsed Nd: YAG laser as the treatment beam source. Laser pulses are generated using a method called passive Q-switching. With this method, short high-power pulses can be emitted. At the target, the emitted pulses cause photodisruption, which is fragmentation of tissue using light energy. HQF,HJO Laser, Ophthalmic,Biomicroscope, Slit-Lamp, Ac-Powered 2 Ophthalmic YAG Laser System
24 04987669101049 DS-10G DS-10G is a digital hand-held camera used to record digital photographs and vide DS-10G is a digital hand-held camera used to record digital photographs and video of the human body. FXF Speculum, Illuminated 1 DIGITAL MEDICAL SCOPE
25 04987669101001 DS-20F NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital phot NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. PJZ Camera, Ophthalmic, General-Use 2 DIGITAL MEDICAL SCOPE
26 04987669100967 17166-6100 Expansion box is the optional accessory that is used to connect a scan delivery Expansion box is the optional accessory that is used to connect a scan delivery unit and the external devices (LAN cable, barcode scanner, or magnetic card reader) to the GYC-500. HQF Laser, Ophthalmic 2 Expansion box
27 04987669101377 SL-2000 The NIDEK SLIT LAMP SL-2000 is used to magnify the eyeball, eyelid, and eyelash The NIDEK SLIT LAMP SL-2000 is used to magnify the eyeball, eyelid, and eyelash of patients for observation, using slit illumination light. HJO Biomicroscope, Slit-Lamp, Ac-Powered 2 Slit Lamp
28 04987669101032 DS-10E DS-10E is a digital hand-held otoscope used to record digital photographs and vi DS-10E is a digital hand-held otoscope used to record digital photographs and video of the human ear’s canal and tympanic membrane. ERA Otoscope 1 DIGITAL MEDICAL SCOPE
29 04987669100998 DS-10F NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital pho NIDEK DS-10F is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. HKI Camera, Ophthalmic, Ac-Powered 2 DIGITAL MEDICAL SCOPE
30 04987669101179 GEA01 The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to co The delivery unit is connected to the YELLOW LASER PHOTOCOAGULATOR YLC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a yellow laser beam (577 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system (SOLIC *1) that ensures low laser power density on the anterior segment is incorporated. The ZEISS SL130 type is available.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). The ZEISS SL130 type is available: *1 Safety Optics with Low Impact on Cornea HQF Laser, Ophthalmic 2 Scan Attachable delivery unit (SL130)
31 04987669101070 DS-10 Control Unit The assembly system (control unit & DS-10EA Adapter & existing endoscope in the The assembly system (control unit & DS-10EA Adapter & existing endoscope in the market) can be used to record digital photographs and video ofthe body. FTT,ERA,FSP,FXF,HKI Camera, Still, Surgical,Otoscope,Loupe, Diagnostic/Surgical,Speculum, Illuminate Camera, Still, Surgical,Otoscope,Loupe, Diagnostic/Surgical,Speculum, Illuminated,Camera, Ophthalmic, Ac-Powered 1 DIGITAL MEDICAL SCOPE
32 04987669101056 DS-10EA DS-10EA Adapter is designed to connect the control unit of DS-10 and the existin DS-10EA Adapter is designed to connect the control unit of DS-10 and the existing endoscope in the market. The assembly system (control unit & DS-10EA Adapter & existing endoscope in the market) can be used to record digital photographs and video of the body. FTT Camera, Still, Surgical 1 DIGITAL MEDICAL SCOPE
33 04987669101025 DS-10D DS-10D is a digital hand-held dermatoscope used to record digital photographs an DS-10D is a digital hand-held dermatoscope used to record digital photographs and video of the human skin. FSP Loupe, Diagnostic/Surgical 1 DIGITAL MEDICAL SCOPE
34 04987669101018 DS-10A DS-10A is a digital hand-held anterior scope used to record digital photographs DS-10A is a digital hand-held anterior scope used to record digital photographs and video of anterior area of the human eye and surrounding area. FXF Speculum, Illuminated 1 DIGITAL MEDICAL SCOPE
35 04987669100905 17441-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. HAAG 900 series type is available. HQF Laser, Ophthalmic 2 Attachable delivery unit (900BQ)
36 04987669100882 17432-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. NIDEK SL-1800 type is available. HQF Laser, Ophthalmic 2 Attachable delivery unit (SL-1800)
37 04987669100875 17431-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated.A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system. The ZEISS 30 SL type is availabe. HQF Laser, Ophthalmic 2 Attachable delivery unit (30SL/M)
38 04987669100837 PM-700 The PD meter model PM-700 is a pupillary distance meter improved with a built-in The PD meter model PM-700 is a pupillary distance meter improved with a built-in computer and LCD digital display. HLG Pupillometer, Ac-Powered 1 PD Meter
39 04987669100431 NT-530 The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry mea The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology. HKX Tonometer, Ac-Powered 2 NON CONTACT TONOMETER
40 04987669100288 17112-0000 This unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC- 1000 This unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC- 1000 (main body) to comprise the photocoagulation system and applied to the treatment of the affected area using the B.I.O. delivery unit (HEINE OMEGA 500). The comprised photocoagulation system makes it possible to switch between photocoagulation with the green laser beam (wavelength: 532 nm) and observation with the B.I.O. GEX Powered Laser Surgical Instrument 2 BIO delivery unit (Heine OMEGA)
41 04987669100233 17402-0000 This delivery unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model This delivery unit is connected to the NIDEK GREEN LASER PHOTOCOAGULATOR, Model GYC-1000 (main body) to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800. The integrated delivery unit which incorporates the SL-1800 comprises the photocoagulation system in connection with the GYC-1000 main body. The attachable delivery unit is mainly the photocoagulation unit and the protective filter unit. They are attached to your slit lamp (NIDEK SL-1800) to comprise the integrated delivery unit. The comprisedintegrated delivery is connected to the GYC-1000 to comprise the photocoagulation system. This photocoagulation system allows the operator to select between photocoagulation with the green laser beam (wavelength: 532 nm) and observation of the affected area with the slit lamp. GEX Powered Laser Surgical Instrument 2 Attachable delivery unit (SL-1800)
42 04987669100134 17462-0000 This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, M This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body. A attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit.They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a slit lamp delivery unit. The comprised slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. HQF Laser, Ophthalmic 2 Attachable delivery unit (SL-1800)
43 04987669100080 MC-500 The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for ophthalmology with the light source of wavelengths 647, 577, and 532 nm. As the conventional laser photocoagulators, the MC-500 can be used for retinal photocoagulation for treatment of ocular fundus diseases like diabetic retinopathy, age-related macular degeneration, retinopathy of prematurity, and retinal detachment, or for laser iridotomy and laser trabeculoplasty for treatment of glaucoma. The device incorporates two types of lasers (diode-pumped solid state laser and laser diode) which enable efficient obtainment of laser beam oscillation of each wavelength. As the conventional device, various types of laser delivery units can be used. Therefore, transpupillary photocoagulation can be performed using various delivery units such as slit lamps and binocular indirect ophthalmoscope. HQF Laser, Ophthalmic 2 Multicolor Laser Photocoagulator
44 04987669100059 CP-770 The NIDEK Chart Projector CP-770 is a test chart presenting device which can ach The NIDEK Chart Projector CP-770 is a test chart presenting device which can achieve refraction distance from 2.9 m to 6.1 m. The device is controlled by a wireless remote control or a control box on the refractor (RT).The CP-770 features the following:• Equipped with 33 types of charts (27 types for Type UK) including various kinds of binocular charts• Program function that allows chart presentation with the touch of a button• Versatile masking function that can even offer the display of even a single character• Chart brightness adjustability to the installation conditions• Switchable function between display and non-display of visual acuity of the chart• A long-life LED for the illumination light source HOX Chart, Visual Acuity 1 CHART PROJECTOR
45 04987669101315 11143-7300 It is used to deliver the laser beam from the main laser device into the eye. Th It is used to deliver the laser beam from the main laser device into the eye. The sterilized endophoto probe comes already sterilized at the factory and is disposable. Sterilized endophoto probes are available in a variety of tip shapes and diameters. GEX Powered Laser Surgical Instrument 2 Sterilized Endophoto Probe(23G/Coaxial)
46 04987669101087 DS-20 Control Unit NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital phot NIDEK DS-20 is a digital hand-held eye-fundus camera used to record digital photographs and video of fundus (including retina, macula and optic disc) of the human eye and surrounding area. DS-20 consists of control unit and optical lens DS-20F (Digital Eye Fundus Camera). PJZ Camera, Ophthalmic, General-Use 2 DIGITAL MEDICAL SCOPE
47 04987669100936 17454-0000 The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to com The delivery unit is connected to the Green Laser Photocoagulator GYC-500 to comprise the photocoagulation system and to treat affected areas using a slit lamp. The photocoagulation system enables photocoagulation using a green laser beam (532 nm) while observing the patient’s eye with the slit lamp. In order to reduce damages to the ocular media, the optical system that ensures low laser power density on the anterior segment is incorporated. A delivery unit to be attached to an existing slit lamp mounted on an existing motorized optical table. The delivery unit is then connected to the main laser device to comprise the photocoagulation system (with the scan function). ZEISS SL130 type is available. HQF Laser, Ophthalmic 2 Scan attachable delivery unit (SL130)
48 04987669100516 RS-3000 Advance The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera t The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera that allows non-invasive and non-contact observation of the shape of the fundus or retina. Fundus surface images (hereafter referred to as SLO image) are captured with the confocal laser scanning using a near-infrared light source with a wavelength of 785 nm. Cross-sectional images of the retina (hereafter referred to as OCT image) are captured with the optical interferometer using an infrared light source with a wavelength of 880 nm. With the images captured using the RS-3000 Advance, the shape and structure of the fundus or retina can be observed, and diseases can be observed. This system is comprised of the main body for capturing images, a computer (hereafter called PC) for storing and analyzing captured images, PC monitor, and an isolation transformer.In addition, the image filing software NAVIS-EX (hereafter referred to as NAVIS-EX) offers the following features:• Image analysis functions such as 3D/map color display or retinal thickness analysis• Networking for data review or analysis on PCs in separate locations OBO Tomography, Optical Coherence 2 OPTICAL COHERENCE TOMOGRAPHY
49 04987669100202 GYC-1000 The GREEN LASER PHOTOCOAGULATOR SYSTEM GYC-1000 is an ophthalmological photocoag The GREEN LASER PHOTOCOAGULATOR SYSTEM GYC-1000 is an ophthalmological photocoagulation system using a solid state laser (green laser beam) with a wavelength of 532nm. Like conventional laser photocoagulation systems, this system is used in ophthalmic surgical procedures, including retinal and macular photocoagulation, iridotomy and trabeculoplasty.Since the GYC-1000 uses a diode laser as its pumping light source, the efficient oscillation of the 532nm laser beam can be obtained. As the GYC-1000 can be used with various kinds of delivery units, the system can be applied to transpupillary photocoagulation using the slit lamp or indirect ophthalmoscope, and to intraocular photocoagulation using the endophotocoagulation probe. GEX Powered Laser Surgical Instrument 2 GREEN LASER PHOTOCOAGULATOR SYSTEM
50 04987669100172 17467-0000 The scan attachable delivery unit is mainly comprised of a photocoagulation unit The scan attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit. They are attached to the Carl Zeiss Meditec SL 130 (Zeiss SL 130) to comprise a scan slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 to comprise a photocoagulation system. The photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. HQF Laser, Ophthalmic 2 Scan attachable delivery unit (SL130)
Other products with the same Product Code "HKX"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 M6333974340 39-7434 39-7434 TONOMETER NON-CONTACT HORUS JEDMED JEDMED INSTRUMENT COMPANY
2 08800019600428 HNT-1 HNT-1 The Non-Contact Tonometer is intended to be used to measure the intraocular pres The Non-Contact Tonometer is intended to be used to measure the intraocular pressure of the human eye. Non-contact Tonometer HNT-1 HUVITZ CO., LTD.
3 08800019600176 HNT-7000 HNT-7000 The Non-Contact Tonometer is intended to be used to measure the intraocular pres The Non-Contact Tonometer is intended to be used to measure the intraocular pressure of the human eye. Non-contact Tonometer HNT-7000 HUVITZ CO., LTD.
4 08437016886021 OP-1S OPTILASA OPTILASA S.L.
5 08437016886014 OP-1H OPTILASA OPTILASA S.L.
6 06430033850947 TP022 Sales package 20pcs of TP022 probes Probes for HOME ICARE FINLAND OY
7 06430033850626 TP022 Single unit blister package Probes for HOME ICARE FINLAND OY
8 06430033850565 TP01s Icare tonometer probes ICARE FINLAND OY
9 06430033850473 TA011 The Icare ic100 tonometer is based on induction-based rebound method, which allo The Icare ic100 tonometer is based on induction-based rebound method, which allows intraocular pressure (IOP) to be measured accurately, rapidlyand without an anesthetic. The Icare ic100 tonometer is intended to be used for the measurement of intraocular pressure of the human eye. Icare ic100 ICARE FINLAND OY
10 06430033850237 TA022 Icare HOME tonometer ICARE FINLAND OY
11 06430033850060 TA01i The Icare tonometer is used in the diagnosis, follow up and screening of glaucom The Icare tonometer is used in the diagnosis, follow up and screening of glaucoma. It is based on induction-based rebound method, which allows intraocular pressure (IOP) to be measured accurately, rapidly and without an anesthetic.The Icare tonometer TA01i is intended to be used for the measurement of intraocular pressure of the human eye. Icare TA01i ICARE FINLAND OY
12 05055272711746 2417-P-2000 Pulsair Desktop (complete) KEELER LIMITED
13 05055272707237 2414-P-2001 Pulsair Intellipuff KEELER LIMITED
14 04987669100431 NT-530 The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry mea The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology. NON CONTACT TONOMETER NIDEK CO.,LTD.
15 04987669100424 NT-510 The NON CONTACT TONOMETER Model NT-510 is designed for non-contact tonometry mea The NON CONTACT TONOMETER Model NT-510 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology. NON CONTACT TONOMETER NIDEK CO.,LTD.
16 04987669100066 TONOREF II AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objecti AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objective refraction, corneal shape measurement, and non-contact tonometry measurement by incorporating a standard auto ref/keratometer and non-contact tonometer into one unit. The objective refraction function measures spherical powers, cylindrical powers and cylinder axis. The corneal shape measurement function measures the radius of corneal curvature (corneal refractive powers), the direction of the steepest meridian, and the amount of corneal astigmatism. The non-contact tonometry function measures the intraocular pressure without contacting the eye. AUTO REF/KERATO/TONOMETER NIDEK CO.,LTD.
17 04987646804109 TO8K The Kowa KT-800 is indicated for measuring intraocular pressure without contacti The Kowa KT-800 is indicated for measuring intraocular pressure without contacting the eye to aid in the screening and diagnosis of glaucoma. KOWA KT-800 KOWA COMPANY,LTD.
18 04582273612167 FT-1000 220V NON-CONTACT TONOMETER TOMEY CORPORATION.
19 04582273612150 FT-1000 The NON-CONTACT TONOMETER FT-1000 is a tonometer designed using a non-contact me The NON-CONTACT TONOMETER FT-1000 is a tonometer designed using a non-contact measurement system. Air puff gently measures the intraocular pressure of the human eye. NON-CONTACT TONOMETER TOMEY CORPORATION.
20 04582273611740 FT-1000 The NON-CONTACT TONOMETER FT-100 is a tonometer designed using a non-contact mea The NON-CONTACT TONOMETER FT-100 is a tonometer designed using a non-contact measurement system Air puff gently measures the intraocular pressure of the human eye. NON-CONTACT TONOMETER TOMEY CORPORATION.
21 04582273600263 FT-1000 NON-CONTACT TONOMETER TOMEY CORPORATION.
22 04562123288179 CT-80 COMPUTERIZED TONOMETER CT-80 TOPCON CORPORATION
23 04549292074369 TX-20 CANON INC. CANON INC.
24 04049584014085 72300 The Corvis® ST is a non-contact tonometer equipped with an opticalPachymetry fun The Corvis® ST is a non-contact tonometer equipped with an opticalPachymetry function.The Corvis® ST measures intraocular pressure without contact with the eyeby applying an air puff to the eye. During the air puff the eye getsilluminated by a 9 mm slit through the apex and a built-in high-speedcamera records the movement of the eye with more than 4000 images persecond.The high-speed camera uses a sequence of 140 Scheimpflug images of thecornea which are analyzed by a built-in computer.Intra ocular pressure is determined by the detection of the applanationmoments of the cornea. Corvis STL OCULUS OPTIKGERÄTE GESELLSCHAFT MIT BESCHRÄNKTER HAFTUNG
25 04047844051276 Grip forceps LSZ1101-A An orthopedic manual surgical instrument is a nonpowered hand-held device intend An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. DIPLOMAT Def. SIGNUS MEDIZINTECHNIK GMBH
26 04047844051269 Grip forceps LSZ1101 An orthopedic manual surgical instrument is a nonpowered hand-held device intend An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. DIPLOMAT Def. SIGNUS MEDIZINTECHNIK GMBH
27 03664188002200 VX220 The VX220 is a multifunctional eye diagnostic device. There are several operatio The VX220 is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: keratometer, corneal topographer, tonometer,and pachymeter and retro illumination VISIONIX LUNEAU TECHNOLOGY OPERATIONS
28 03664188001203 VX120 The VX120 is a multifunctional eye diagnostic device. There are several operatio The VX120 is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefracter keratometer, corneal topographer, tonometer, pachymeter and retro illumination. VISIONIX LUNEAU TECHNOLOGY OPERATIONS
29 03664188001180 VX118 The VX118 is a multifunctional eye diagnostic device. There are several operatio The VX118 is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefracter keratometer, corneal topographer, pachymeter and retro illumination. VISIONIX LUNEAU TECHNOLOGY OPERATIONS
30 03664188000909 VX130 The VX130 is a multi-function diagnostic device combining wavefront aberometer, The VX130 is a multi-function diagnostic device combining wavefront aberometer, corneal topographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation Photographing the eye and taking images of the eye to evaluate the thickness of the centralcornea. Full cornea thickness map Scheimpflug imaging Anterior chamber imaging Pupil ImageImage of the cornea relative to the iris VISIONIX LUNEAU TECHNOLOGY OPERATIONS
31 03664188000046 VX120+ The VX120+ is a multi-function diagnostic device combining corneal topographer, The VX120+ is a multi-function diagnostic device combining corneal topographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation. Photographing the eye and taking images of the eye to evaluate the thickness of the cornea.Analysis of the tear film and evaluation of tear film non-invasive tear break-up time (NITBUT)Meibomian glands imagingEvaluation of tear meniscus height VISIONIX LUNEAU TECHNOLOGY OPERATIONS
32 03664188000039 VX130+ The VX130+ is a multifunctional eye diagnostic device. There are several operati The VX130+ is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefractometer, keratometer, corneal topographer, tonometer, multi-slit pachymeter, tear-film analyzer , and retro illumination.The VX130+ is a multi-function diagnostic device combining wavefront aberometer, cornealtopographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation Photographing the eye and taking images of the eye to evaluate the thickness of the central cornea. Full cornea thickness map Scheimpflug imaging Anterior chamber imaging Pupil ImageImage of the cornea relative to the irisAnalysis of the tear film and evaluation of tear film non-invasive tear break-up time (NITBUT)Meibomian glands imagingEvaluation of tear meniscus height VISIONIX LUNEAU TECHNOLOGY OPERATIONS
33 03615020000380 WAM700 The WAM700 is a multifunctional ophthalmic device. The machine is a combination The WAM700 is a multifunctional ophthalmic device. The machine is a combination of 5 technologies :- Shack Hartmann technology : to measure both low and high order aberrations of the eye, to measure refraction.- Placido disks : for keratometry and for corneal topography measurement.- Non-contact tonometer.- Scheimpflug image : for anterior chamber analysis (pachymetry, irido corneal angle).- Retro illumination : for detection of opacity.Measurement is fully automatic using image processing software and fully automated motors for centering and focusing. The machine includes a fixation target with automatic fogging for accommodation control. WAVE ANALYZER MEDICA 700 ESSILOR INTERNATIONAL
34 00851158007706 ETN-1800 Non-Contact Tonometer Eli Ezer U.S. OPHTHALMIC, L.L.C.
35 00851158007119 TN-180B LuxVision U.S. OPHTHALMIC, L.L.C.
36 00851158007102 TN-150B LuxVision U.S. OPHTHALMIC, L.L.C.
37 00812559012195 16080 AC-powered, non-contact tonometer indicated for measuring intraocular pressure ( AC-powered, non-contact tonometer indicated for measuring intraocular pressure (IOP) to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement. VISUPLAN 500 REICHERT, INC.
38 00812559012188 230678 Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pne Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement. Model 30™ Tip and Membrane Assembly for Pneumatonometer REICHERT, INC.
39 00812559012171 230677 Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pn Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement. Model 30™ Tip and Membrane Assembly for Pneumatonometer REICHERT, INC.
40 00812559012164 230676 One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneu One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement. Model 30™ Tip and Membrane Assembly for Pneumatonometer REICHERT, INC.
41 00812559011976 16170 AC-powered, non-contact tonometer intended to measure the intraocular pressure o AC-powered, non-contact tonometer intended to measure the intraocular pressure of the eye and the biomechanical response of the cornea for the purpose of aiding in the diagnosis and monitoring of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement. Ocular Response Analyzer® G3 REICHERT, INC.
42 00812559011020 16060 AC -powered non-contact tonometer intended to measure the intraocular pressure o AC -powered non-contact tonometer intended to measure the intraocular pressure of the eye, taking into consideration the biomechanical response of the cornea. An air puff is used to momentarily flatten a patient's cornea during the measurement. Reichert® 7CR Auto Tonometer REICHERT, INC.
43 00812559010979 16032 AC powered contact tonometer intended for the measurement of intraocular pressu AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected. Model 30 Pneumatonometer REICHERT, INC.
44 00812559010962 16031 AC powered contact tonometer intended for the measurement of intraocular pressu AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected. Model 30 Pneumatonometer REICHERT, INC.
45 00812559010955 16030 AC powered contact tonometer intended for the measurement of intraocular pressu AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected. Model 30 Pneumatonometer REICHERT, INC.
46 00812559010429 13850 Handheld, battery-powered, non-contact tonometer intended to measure the intraoc Handheld, battery-powered, non-contact tonometer intended to measure the intraocular pressure of the eye. An air puff is used to momentarily flatten a patient's cornea during the measurement. PT100 Portable Non-Contact Tonometer REICHERT, INC.
47 00812559010177 16050 AC powered, non-contact tonometer indicated for measuring intraocular pressure AC powered, non-contact tonometer indicated for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement. Reichert® 7 Auto Tonometer REICHERT, INC.
48 16430033850623 TP022 Sales package 50pcs Probes for HOME ICARE FINLAND OY