Other products from "NEUROSOFT, OOO"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04650075330074 Focus 2-channel neurodiagnostic testing system designed to enable reliable recording, 2-channel neurodiagnostic testing system designed to enable reliable recording, display and documentation of electrophysiological information from thehuman nervous and muscular systems in a clinical environment. The system enables the healthcare provider to perform evoked potentials, nerve conductions and needle EMG studies as an aid in the evaluation of patients with central and peripheral nervous system symptoms. JXE,IKN Device, Nerve Conduction Velocity Measurement,Electromyograph, Diagnostic 2 Focus
2 04650075333174 MEGA-TMS The device is intended for magnetic stimulation of peripheral nerves. The obtain The device is intended for magnetic stimulation of peripheral nerves. The obtained responses of stimulated structures can be recorded with EMG system for further diagnostic evaluation. GWF Stimulator, Electrical, Evoked Response 2 MEGA-TMS
3 04650075330197 TMS The Neurosoft TMS system is indicated for the treatment of Major Depressive Dis The Neurosoft TMS system is indicated for the treatment of Major Depressive Disorder in adult patients who have failed to receive satisfactory improvement from prior antidepressant medications in the current episode. OBP Transcranial Magnetic Stimulator 2 Neurosoft
4 04650075330081 CloudEKG The CloudEKG device is a 12 standard leads battery operated unit intended for The CloudEKG device is a 12 standard leads battery operated unit intended for recording and transmitting standard electrocardiogram signals for cardiac monitoring and diagnosis by healthcare professionals.Recorded signals are processed by the device and transmitted to a PC or hand-held monitoring device wirelessly using Bluetooth technology.The transmitted signals are displayed on the monitoring device to allow for their review, analysis, saving and printing by healthcare professionals.CloudEKG can be 'used in adults and infants weighing less than 22 lbs (10 Kg) but is not appropriate for use to monitor critical patients or perform intracardiac recordings.All measurements obtained with the CloudEKG device should take into account the patient's clinical symptoms and findings to be considered valid and no treatment by drugs or other therapies should be initiated based solely on the measurements obtained with the device. DXH Transmitters And Receivers, Electrocardiograph, Telephone 2 CloudEKG
5 04650075333211 CloudEEG The digital systems CloudEEG are intended for use as digital neurophysiological The digital systems CloudEEG are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 19 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
6 04650075330128 Neuron-Spectrum-4 The digital systems Neuron-Spectrum-4 are intended for use as digital neurophys The digital systems Neuron-Spectrum-4 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 21 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
7 04650075330111 Neuron-Spectrum-3 The digital systems Neuron-Spectrum-3 are intended for use as digital neurophys The digital systems Neuron-Spectrum-3 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 19 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
8 04650075330104 Neuron-Spectrum-2 The digital systems Neuron-Spectrum-2 are intended for use as digital neurophys The digital systems Neuron-Spectrum-2 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 16 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
9 04650075330098 Neuron-Spectrum-1 The digital systems Neuron-Spectrum-1 are intended for use as digital neurophys The digital systems Neuron-Spectrum-1 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 8 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
10 04650075330036 Neuro-Audio The Neuro-Audio system is indicated for use in the recording and analysis of hum The Neuro-Audio system is indicated for use in the recording and analysis of human physiological data used for the diagnosis of auditory and hearing-related functions. It is intended as an aid to healthcare professionals trained and skilled in audiology. The system assists in the evaluation, documentation and diagnosis of ear disorders in humans using evoked potentials (EP), electrocochleography (ECochG), auditory brainstem response (ABR), auditory steady-state response (ASSR), otoacoustic emission (OAE) and pure tone audiometry (PTA).The device is intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals and experimental laboratories.The patient group includes all ages and genders. GWJ,EWO Stimulator, Auditory, Evoked Response,Audiometer 2 Neuro-Audio
11 04650075330371 Neuro-IOM Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for in Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for intraoperative neurophysiologic monitoring: the device provides information to assess a patient’s neurophysiological status.The system allows to monitor the functional integrity and/or mapping of central and peripheral nervous system including motor and sensory pathways. It is provided in III different configurations:I. 32/B II. 32/S III. 16/S The system ensures the following IOM modalities: free-run EMG (electromyography), direct nerve stimulation including pedicle screw test, SSEP (somatosensory evoked potentials), MEP (motor evoked potentials), EEG (electroencephalography), AEP (au-ditory evoked potentials), VEP (visual evoked potentials), direct cortical stimulation. Also the train-of-four (TOF) stimulation is performed.The system is not intended to measure the vital signs. It records the data to be inter-preted by the neuromonitoring specialist. GWF,GWE,GWJ,OLT,PDQ Stimulator, Electrical, Evoked Response,Stimulator, Photic, Evoked Response,Stim Stimulator, Electrical, Evoked Response,Stimulator, Photic, Evoked Response,Stimulator, Auditory, Evoked Response,Non-Normalizing Quantitative Electroencephalograph Software,Neurosurgical Nerve Locator 2 Neuro-IOM
12 04650075330296 CloudTMS The CloudTMS system is indicated for the treatment of Major Depressive Disorder The CloudTMS system is indicated for the treatment of Major Depressive Disorder in adult patients who have failed to receive satisfactory improvement from prior antidepressant medications in the current episode. OBP Transcranial Magnetic Stimulator 2 CloudTMS
Other products with the same Product Codes "GWQ, OLV, OLT"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10846446066050 31759-001 31759-001 SWR KIT, SOMNOSTAR 11.2 HOTFIX SomnoStar CAREFUSION CORPORATION
2 10846446065046 28009-001 28009-001 CD,SOMNOSTAR VER 11.1 Somnostar CAREFUSION CORPORATION
3 10846446033328 30862-001 30862-001 CD, LabManager HL7 Hotfix Somnostar CAREFUSION CORPORATION
4 10846446033298 29675-001 29675-001 SOMNOSTAR 11 UPGRADE Somnostar CAREFUSION CORPORATION
5 10846446033274 28481-001 28481-001 SWR KIT SOMNOSTAR VER 11 SWR BUNDLE FIRST LIC Somnostar CAREFUSION CORPORATION
6 10846446033267 27686-001 27686-001 SOMNOSTAR SECURITY ADMIN Somnostar CAREFUSION CORPORATION
7 10846446033250 27188-001 27188-001 SWR,KIT SOMNOSTAR 10.2 VID UPG Somnostar CAREFUSION CORPORATION
8 10846446033243 27187-001 27187-001 SOMNOSTAR 10.2 VIDEO UPGRADE KIT Somnostar CAREFUSION CORPORATION
9 10846446032628 28482-001 28482-001 SWR KIT RPT CENTER SSPRO VER 11 Somnostar CAREFUSION CORPORATION
10 10846446032611 28477-001 28477-001 SWR KIT SSPRO NEW SYS VER 11 Somnostar CAREFUSION CORPORATION
11 10846446032604 28483-001 28483-001 SOMNOSTAR Z4 SYSTEM VER 11 Somnostar CAREFUSION CORPORATION
12 10846446032598 28484-001 28484-001 ACQ STN 1 BED Z4 VER 11 Somnostar CAREFUSION CORPORATION
13 10846446032550 28008-001 28008-001 SWR KIT SSPRO SOFTWARE VER 11 Somnostar CAREFUSION CORPORATION
14 10846446032260 63783 63783 SOFTWARE KIT LABMANAGER SQL PATCH Somnostar CAREFUSION CORPORATION
15 10846446032208 26322-001 26322-001 LABMANAGER WORD 2013 REPORT HOTFIX CD Somnostar CAREFUSION CORPORATION
16 10846446032185 23486-001 23486-001 SWR KIT SSPRO NEW SYS VER 10 Somnostar CAREFUSION CORPORATION
17 10846446031485 22312-001 22312-001 SWR KIT SSPRO SOFTWARE VER 10.2 Somnostar CAREFUSION CORPORATION
18 10846446025422 23586-001 23586-001 SOMNOSTAR Z4 SYSTEM VER 10 Somnostar CAREFUSION CORPORATION
19 10846446025415 23474-001 23474-001 SWR KIT RPT CENTER SSPRO VER 10 Somnostar CAREFUSION CORPORATION
20 10846446025392 23469-001 23469-001 ACQ STN 1 BED Z4 VER 10 Somnostar CAREFUSION CORPORATION
21 10846446024913 16623 16623 PWR SPLY/+15V 50W PSU V32 Somnostar CAREFUSION CORPORATION
22 10846446024524 11626 11626 KIT,z4 LEAD(NOTE: this GTIN is not associated with the marketed product) Somnostar CAREFUSION CORPORATION
23 10846446021080 776612 776612 SWR KIT LABMGR SQL SETUP WIZARD Somnostar CAREFUSION CORPORATION
24 10846446020304 69329 69329 CAREFUSION,THERMOCOUPLE (ADULT) - This GTIN is not associated with the marketed product Somnostar CAREFUSION CORPORATION
25 10846446020274 63734 63734 SWR KIT SSPRO SOFTWARE VER 9 Somnostar CAREFUSION CORPORATION
26 10846446020151 16955 16955 CABLE ASSY,OVERMOLD,50 PIN,HEADBOX Somnostar CAREFUSION CORPORATION
27 10846446020144 16954 16954 ASSY/AMP SLEEP RC 9.1+ Somnostar CAREFUSION CORPORATION
28 10846446020076 16610 16610 HEADBOX ASSEMBLY Somnostar CAREFUSION CORPORATION
29 10843997005804 2479 SedLine™ EEG Sensor MASIMO CORPORATION
30 10841983103084 NC-143E NC-143E Electrode Clip, Limb NA NIHON KOHDEN AMERICA, INC.
31 10841983102742 TL-274T3 TL-274T3 SpO2 probe Child / Infant (from 3 to 20 kg) Finger or toe, disposable BluPRO® NIHON KOHDEN AMERICA, INC.
32 10841983102735 TL-273T3 TL-273T3 SpO2 probe Adults (40 kg or more) Finger or toe, disposable BluPRO® NIHON KOHDEN AMERICA, INC.
33 10841983102728 TL-272T3 TL-272T3 SpO2 probe Child (from 10 to 50 kg) Finger or toe, disposable BluPRO® NIHON KOHDEN AMERICA, INC.
34 10841983102711 TL-271T3 TL-271T3 SpO2 probe Adults (30 kg or more) Finger or toe, disposable, 160cm cable BluPRO® NIHON KOHDEN AMERICA, INC.
35 10841983102704 TL-271T TL-271T SpO2 probe Adults (30 kg or more) Finger or toe, disposable, 80cm cable BluPRO® NIHON KOHDEN AMERICA, INC.
36 10841983102704 TL-271T TL-271T SpO2 probe Adults (30 kg or more) Finger or toe, disposable, 80cm cable BluPRO® NIHON KOHDEN AMERICA, INC.
37 10841983102704 TL-271T TL-271T SpO2 probe Adults (30 kg or more) Finger or toe, disposable, 80cm cable BluPRO® NIHON KOHDEN AMERICA, INC.
38 10841983102674 TL-062S TL-062S SpO2 probe Child, infant (from 3 to 15 kg) Toe, disposable NA NIHON KOHDEN AMERICA, INC.
39 10841983102674 TL-062S TL-062S SpO2 probe Child, infant (from 3 to 15 kg) Toe, disposable NA NIHON KOHDEN AMERICA, INC.
40 10841983102674 TL-062S TL-062S SpO2 probe Child, infant (from 3 to 15 kg) Toe, disposable NA NIHON KOHDEN AMERICA, INC.
41 10841983102667 TL-052S TL-052S SpO2 probe Adults, child (from 15 to 50 kg) Finger, disposable NA NIHON KOHDEN AMERICA, INC.
42 10841983102667 TL-052S TL-052S SpO2 probe Adults, child (from 15 to 50 kg) Finger, disposable NA NIHON KOHDEN AMERICA, INC.
43 10841983102667 TL-052S TL-052S SpO2 probe Adults, child (from 15 to 50 kg) Finger, disposable NA NIHON KOHDEN AMERICA, INC.
44 10841983101530 YG-213T YG-213T Airway adapter for neonate and child, TG-970P NA NIHON KOHDEN AMERICA, INC.
45 10841983101523 YG-211T YG-211T Airway adapter for adult and child NA NIHON KOHDEN AMERICA, INC.
46 10841522106279 90481 N/A EEG Module Trulink SPACELABS HEALTHCARE (WASHINGTON), INC
47 10841522100253 91482 91482 MODULE BISX, 91482 UltraviewSL SPACELABS HEALTHCARE (WASHINGTON), INC
48 10190752173545 466631 466631 ELECTRODES BLUE SENSOR DISP WET GEL LTV VYAIRE MEDICAL, INC.
49 10190752167629 24-773170-102 24-773170-102 RESPITRACE Q.D.C. Avea VYAIRE MEDICAL, INC.
50 10190752161993 28008-001 28008-001 SWR KIT SSPRO SOFTWARE VER 11 SOMNOSTAR VYAIRE MEDICAL, INC.