Other products from "NEUROSOFT, OOO"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04650075330074 Focus 2-channel neurodiagnostic testing system designed to enable reliable recording, 2-channel neurodiagnostic testing system designed to enable reliable recording, display and documentation of electrophysiological information from thehuman nervous and muscular systems in a clinical environment. The system enables the healthcare provider to perform evoked potentials, nerve conductions and needle EMG studies as an aid in the evaluation of patients with central and peripheral nervous system symptoms. JXE,IKN Device, Nerve Conduction Velocity Measurement,Electromyograph, Diagnostic 2 Focus
2 04650075333174 MEGA-TMS The device is intended for magnetic stimulation of peripheral nerves. The obtain The device is intended for magnetic stimulation of peripheral nerves. The obtained responses of stimulated structures can be recorded with EMG system for further diagnostic evaluation. GWF Stimulator, Electrical, Evoked Response 2 MEGA-TMS
3 04650075330197 TMS The Neurosoft TMS system is indicated for the treatment of Major Depressive Dis The Neurosoft TMS system is indicated for the treatment of Major Depressive Disorder in adult patients who have failed to receive satisfactory improvement from prior antidepressant medications in the current episode. OBP Transcranial Magnetic Stimulator 2 Neurosoft
4 04650075330081 CloudEKG The CloudEKG device is a 12 standard leads battery operated unit intended for The CloudEKG device is a 12 standard leads battery operated unit intended for recording and transmitting standard electrocardiogram signals for cardiac monitoring and diagnosis by healthcare professionals.Recorded signals are processed by the device and transmitted to a PC or hand-held monitoring device wirelessly using Bluetooth technology.The transmitted signals are displayed on the monitoring device to allow for their review, analysis, saving and printing by healthcare professionals.CloudEKG can be 'used in adults and infants weighing less than 22 lbs (10 Kg) but is not appropriate for use to monitor critical patients or perform intracardiac recordings.All measurements obtained with the CloudEKG device should take into account the patient's clinical symptoms and findings to be considered valid and no treatment by drugs or other therapies should be initiated based solely on the measurements obtained with the device. DXH Transmitters And Receivers, Electrocardiograph, Telephone 2 CloudEKG
5 04650075333211 CloudEEG The digital systems CloudEEG are intended for use as digital neurophysiological The digital systems CloudEEG are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 19 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
6 04650075330135 Neuron-Spectrum-4/P The digital systems Neuron-Spectrum- 4/P are intended for use as digital neurop The digital systems Neuron-Spectrum- 4/P are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 21EEG channels, up to 4 polygraphic channels ,1 breath channel and 2 direct current channels.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
7 04650075330128 Neuron-Spectrum-4 The digital systems Neuron-Spectrum-4 are intended for use as digital neurophys The digital systems Neuron-Spectrum-4 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 21 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
8 04650075330111 Neuron-Spectrum-3 The digital systems Neuron-Spectrum-3 are intended for use as digital neurophys The digital systems Neuron-Spectrum-3 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 19 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
9 04650075330098 Neuron-Spectrum-1 The digital systems Neuron-Spectrum-1 are intended for use as digital neurophys The digital systems Neuron-Spectrum-1 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 8 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
10 04650075330036 Neuro-Audio The Neuro-Audio system is indicated for use in the recording and analysis of hum The Neuro-Audio system is indicated for use in the recording and analysis of human physiological data used for the diagnosis of auditory and hearing-related functions. It is intended as an aid to healthcare professionals trained and skilled in audiology. The system assists in the evaluation, documentation and diagnosis of ear disorders in humans using evoked potentials (EP), electrocochleography (ECochG), auditory brainstem response (ABR), auditory steady-state response (ASSR), otoacoustic emission (OAE) and pure tone audiometry (PTA).The device is intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals and experimental laboratories.The patient group includes all ages and genders. GWJ,EWO Stimulator, Auditory, Evoked Response,Audiometer 2 Neuro-Audio
11 04650075330371 Neuro-IOM Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for in Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for intraoperative neurophysiologic monitoring: the device provides information to assess a patient’s neurophysiological status.The system allows to monitor the functional integrity and/or mapping of central and peripheral nervous system including motor and sensory pathways. It is provided in III different configurations:I. 32/B II. 32/S III. 16/S The system ensures the following IOM modalities: free-run EMG (electromyography), direct nerve stimulation including pedicle screw test, SSEP (somatosensory evoked potentials), MEP (motor evoked potentials), EEG (electroencephalography), AEP (au-ditory evoked potentials), VEP (visual evoked potentials), direct cortical stimulation. Also the train-of-four (TOF) stimulation is performed.The system is not intended to measure the vital signs. It records the data to be inter-preted by the neuromonitoring specialist. GWF,GWE,GWJ,OLT,PDQ Stimulator, Electrical, Evoked Response,Stimulator, Photic, Evoked Response,Stim Stimulator, Electrical, Evoked Response,Stimulator, Photic, Evoked Response,Stimulator, Auditory, Evoked Response,Non-Normalizing Quantitative Electroencephalograph Software,Neurosurgical Nerve Locator 2 Neuro-IOM
12 04650075330296 CloudTMS The CloudTMS system is indicated for the treatment of Major Depressive Disorder The CloudTMS system is indicated for the treatment of Major Depressive Disorder in adult patients who have failed to receive satisfactory improvement from prior antidepressant medications in the current episode. OBP Transcranial Magnetic Stimulator 2 CloudTMS
Other products with the same Product Codes "GWQ, OLV, OLT"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00850154007086 RS-0003 RS-0003 Cervello Software for use with Blackrock Neuromed systems, version 1.04 and all Cervello Software for use with Blackrock Neuromed systems, version 1.04 and all sub releases. CERVELLO SOFTWARE BLACKROCK NEUROMED, LLC
2 00850154007086 RS-0003 RS-0003 Cervello Software for use with Blackrock Neuromed systems, version 1.04 and all Cervello Software for use with Blackrock Neuromed systems, version 1.04 and all sub releases. CERVELLO SOFTWARE BLACKROCK NEUROMED, LLC
3 00850154007079 NM-0354 NM-0354 Micromed MORPHEUS Amplifer for HOME LTM. MORPHEUS BLACKROCK NEUROMED, LLC
4 00850154007079 NM-0354 NM-0354 Micromed MORPHEUS Amplifer for HOME LTM. MORPHEUS BLACKROCK NEUROMED, LLC
5 00850154007055 7524 7524 JackBox with 64 Common Reference Inputs, with 6 of them to be switched to Bipola JackBox with 64 Common Reference Inputs, with 6 of them to be switched to Bipolar, to be used with CERVELLO 64 Series Headboxes JB CERVELLO 64 BLACKROCK NEUROMED, LLC
6 00850154007055 7524 7524 JackBox with 64 Common Reference Inputs, with 6 of them to be switched to Bipola JackBox with 64 Common Reference Inputs, with 6 of them to be switched to Bipolar, to be used with CERVELLO 64 Series Headboxes JB CERVELLO 64 BLACKROCK NEUROMED, LLC
7 00850154007048 7512 7512 JackBox with 32 Common Reference Inputs, 21 arranged as Head Shape, 8 to be swit JackBox with 32 Common Reference Inputs, 21 arranged as Head Shape, 8 to be switched to Bipolar, to be used with CERVELLO 32 Series Headboxes JB CERVELLO 32 BLACKROCK NEUROMED, LLC
8 00850154007048 7512 7512 JackBox with 32 Common Reference Inputs, 21 arranged as Head Shape, 8 to be swit JackBox with 32 Common Reference Inputs, 21 arranged as Head Shape, 8 to be switched to Bipolar, to be used with CERVELLO 32 Series Headboxes JB CERVELLO 32 BLACKROCK NEUROMED, LLC
9 00850154007031 NM-0262 NM-0262 Cervello 64 LTM / Ambulatory Headbox, needs Jack Box - WiFi Model CERVELLO 64 W BLACKROCK NEUROMED, LLC
10 00850154007031 NM-0262 NM-0262 Cervello 64 LTM / Ambulatory Headbox, needs Jack Box - WiFi Model CERVELLO 64 W BLACKROCK NEUROMED, LLC
11 00850154007024 NM-0261 NM-0261 Cervello 32 LTM / Ambulatory Headbox, needs Jack Box - WiFi Model CERVELLO 32 W BLACKROCK NEUROMED, LLC
12 00850154007024 NM-0261 NM-0261 Cervello 32 LTM / Ambulatory Headbox, needs Jack Box - WiFi Model CERVELLO 32 W BLACKROCK NEUROMED, LLC
13 00850154007017 7523 7523 Cervello 64 LTM / Ambulatory Headbox, needs Jack Box - Bluetooth Model CERVELLO 64 BLACKROCK NEUROMED, LLC
14 00850154007017 7523 7523 Cervello 64 LTM / Ambulatory Headbox, needs Jack Box - Bluetooth Model CERVELLO 64 BLACKROCK NEUROMED, LLC
15 00850154007000 7511 7511 Cervello 32 LTM / Ambulatory Headbox, needs Jack Box - Bluetooth Model CERVELLO 32 BLACKROCK NEUROMED, LLC
16 00850154007000 7511 7511 Cervello 32 LTM / Ambulatory Headbox, needs Jack Box - Bluetooth Model CERVELLO 32 BLACKROCK NEUROMED, LLC
17 00850033571035 473xxxx HydroCel Geodesic Sensor Net - HCGSN 130 MAGSTIM, INC.
18 00850033571011 479xxxx MicroCel Geodesic Sensor Net - MCGSN 100 Series MAGSTIM, INC.
19 00850033571004 140xxxx Geodesic EEG System - GES 400 Series MAGSTIM, INC.
20 00850015266546 SP29-1002.LE(GER) Sleep Profiler PSG2 LE Device Kit No Belts (PM3) German Sleep Profiler PSG2 ADVANCED BRAIN MONITORING, INC.
21 00850015266539 SP40-1001.LE(GER) Sleep Profiler LE Device Kit German Sleep Profiler ADVANCED BRAIN MONITORING, INC.
22 00850015266522 SP40-1001.LE(ITA) Sleep Profiler LE Device Kit Italian Sleep Profiler ADVANCED BRAIN MONITORING, INC.
23 00850015266423 XS30-4210.2 X-Small 10-20 Single-Use Strip Kit (Qty 2) X-Series ADVANCED BRAIN MONITORING, INC.
24 00850015266416 30-4210 X-Small 10-20 Single-Use Strip X-Series ADVANCED BRAIN MONITORING, INC.
25 00850015266409 02-4321 Disposable Foam Sensors (Qty 252) X-Series ADVANCED BRAIN MONITORING, INC.
26 00850015266348 XS30-1007 X24 Stat System Kit Clinical X-Series ADVANCED BRAIN MONITORING, INC.
27 00850015266331 XS30-4212.5 Medium 10-20 Single-Use Strip Kit (Qty 5) X-Series ADVANCED BRAIN MONITORING, INC.
28 00850015266324 XS30-4211.5 Small 10-20 Single-Use Strip Kit (Qty 5) X-Series ADVANCED BRAIN MONITORING, INC.
29 00850015266317 XS30-4212 Medium 10-20 Single-Use Strip Kit X-Series ADVANCED BRAIN MONITORING, INC.
30 00850015266300 XS30-4211 Small 10-20 Single-Use Strip Kit X-Series ADVANCED BRAIN MONITORING, INC.
31 00850015266294 30-4212 Medium 10-20 Single-Use Strip X-Series ADVANCED BRAIN MONITORING, INC.
32 00850015266287 30-4211 Small 10-20 Single-Use Strip X-Series ADVANCED BRAIN MONITORING, INC.
33 00850015266225 SP40-1001 Sleep Profiler Device Kit (No sensors) Sleep Profiler ADVANCED BRAIN MONITORING, INC.
34 00850015266201 UN03-4007 Effort Cable Single Channel Kit Sleep Profiler PSG2 ADVANCED BRAIN MONITORING, INC.
35 00850008393259 BWMini HST Compass SI1842 Polysomnograph BWMini HST Compass Neurovirtual NEUROVIRTUAL USA, INC.
36 00850008393242 BWMini HST PV2312 Polysomnograph BWMini HST Neurovirtual NEUROVIRTUAL USA, INC.
37 00850008393235 BWMini EEG PV2310 Electroencephalograph BWMini EEG Neurovirtual NEUROVIRTUAL USA, INC.
38 00850008393228 BWMini PSG PV2311 Polysomnograph BWMini PSG Neurovirtual NEUROVIRTUAL USA, INC.
39 00850008393211 BWIII PSG Plus PV2009 Polysomnograph and Electroencephalograph BWIII PSG Plus Neurovirtual NEUROVIRTUAL USA, INC.
40 00850008393211 BWIII PSG Plus PV2009 Polysomnograph and Electroencephalograph BWIII PSG Plus Neurovirtual NEUROVIRTUAL USA, INC.
41 00850008393204 BWIII PSG PV2008 Polysomnograph BWIII PSG Neurovirtual NEUROVIRTUAL USA, INC.
42 00850008393198 BWIII EEG Plus PV2007 Electroencephalograph BWIII EEG Plus Neurovirtual NEUROVIRTUAL USA, INC.
43 00850008393181 BWIII EEG PV2006 Electroencephalograph BWIII EEG Neurovirtual NEUROVIRTUAL USA, INC.
44 00850008393174 BWIII Basics PV2010 Electroencephalograph BWIII Basics Neurovirtual NEUROVIRTUAL USA, INC.
45 00843997012355 9185 Sedline™ Monitor MASIMO CORPORATION
46 00843997009096 9513 Sedline® Seditation Monitor MASIMO CORPORATION
47 00843997007955 3637 SedLine® Patient Cable MASIMO CORPORATION
48 00843997005814 2480 SedLine Patient Cable MASIMO CORPORATION
49 00841983104329 EEG-1260A EEG-1260A NEUROFAX ACQUISITION, SML FRM Neurofax NIHON KOHDEN AMERICA, INC.
50 00841983104008 A/ONEBED-SCORE-11X A/ONEBED-SCORE-11X Polysomnography Sleep System Version 11 Polysmith Sleep System NIHON KOHDEN AMERICA, INC.