Other products from "NEUROSOFT, OOO"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04650075330074 Focus 2-channel neurodiagnostic testing system designed to enable reliable recording, 2-channel neurodiagnostic testing system designed to enable reliable recording, display and documentation of electrophysiological information from thehuman nervous and muscular systems in a clinical environment. The system enables the healthcare provider to perform evoked potentials, nerve conductions and needle EMG studies as an aid in the evaluation of patients with central and peripheral nervous system symptoms. JXE,IKN Device, Nerve Conduction Velocity Measurement,Electromyograph, Diagnostic 2 Focus
2 04650075333174 MEGA-TMS The device is intended for magnetic stimulation of peripheral nerves. The obtain The device is intended for magnetic stimulation of peripheral nerves. The obtained responses of stimulated structures can be recorded with EMG system for further diagnostic evaluation. GWF Stimulator, Electrical, Evoked Response 2 MEGA-TMS
3 04650075330197 TMS The Neurosoft TMS system is indicated for the treatment of Major Depressive Dis The Neurosoft TMS system is indicated for the treatment of Major Depressive Disorder in adult patients who have failed to receive satisfactory improvement from prior antidepressant medications in the current episode. OBP Transcranial Magnetic Stimulator 2 Neurosoft
4 04650075333211 CloudEEG The digital systems CloudEEG are intended for use as digital neurophysiological The digital systems CloudEEG are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 19 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
5 04650075330135 Neuron-Spectrum-4/P The digital systems Neuron-Spectrum- 4/P are intended for use as digital neurop The digital systems Neuron-Spectrum- 4/P are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 21EEG channels, up to 4 polygraphic channels ,1 breath channel and 2 direct current channels.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
6 04650075330128 Neuron-Spectrum-4 The digital systems Neuron-Spectrum-4 are intended for use as digital neurophys The digital systems Neuron-Spectrum-4 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 21 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
7 04650075330111 Neuron-Spectrum-3 The digital systems Neuron-Spectrum-3 are intended for use as digital neurophys The digital systems Neuron-Spectrum-3 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 19 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
8 04650075330104 Neuron-Spectrum-2 The digital systems Neuron-Spectrum-2 are intended for use as digital neurophys The digital systems Neuron-Spectrum-2 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 16 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
9 04650075330098 Neuron-Spectrum-1 The digital systems Neuron-Spectrum-1 are intended for use as digital neurophys The digital systems Neuron-Spectrum-1 are intended for use as digital neurophysiological systems intended for recording, processing and display biopotential signals such as Electroencephalography (EEG) and long-latency Evoked Potential (EP). Polysomnography (PSG) derives from Electroencephalography (EEG) by the means of a dedicated software module and dedicated electrodes.The devices are portable and can register up to 8 EEG channels, 1 polygraphic channel and 1 breath channel.The devices do not provide alarms, do not provide automated event marking and do not provide to the user any diagnostic conclusion about the patient's condition. They are intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals experimental laboratories and sleep laboratories. The patient group includes all ages and sexes. GWQ,OLV,OLT Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electro Full-Montage Standard Electroencephalograph,Standard Polysomnograph With Electroencephalograph,Non-Normalizing Quantitative Electroencephalograph Software 2 Neuron-Spectrum
10 04650075330036 Neuro-Audio The Neuro-Audio system is indicated for use in the recording and analysis of hum The Neuro-Audio system is indicated for use in the recording and analysis of human physiological data used for the diagnosis of auditory and hearing-related functions. It is intended as an aid to healthcare professionals trained and skilled in audiology. The system assists in the evaluation, documentation and diagnosis of ear disorders in humans using evoked potentials (EP), electrocochleography (ECochG), auditory brainstem response (ABR), auditory steady-state response (ASSR), otoacoustic emission (OAE) and pure tone audiometry (PTA).The device is intended for use in the patient care institutions, diagnostics centers, neurosurgical hospitals and experimental laboratories.The patient group includes all ages and genders. GWJ,EWO Stimulator, Auditory, Evoked Response,Audiometer 2 Neuro-Audio
11 04650075330371 Neuro-IOM Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for in Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for intraoperative neurophysiologic monitoring: the device provides information to assess a patient’s neurophysiological status.The system allows to monitor the functional integrity and/or mapping of central and peripheral nervous system including motor and sensory pathways. It is provided in III different configurations:I. 32/B II. 32/S III. 16/S The system ensures the following IOM modalities: free-run EMG (electromyography), direct nerve stimulation including pedicle screw test, SSEP (somatosensory evoked potentials), MEP (motor evoked potentials), EEG (electroencephalography), AEP (au-ditory evoked potentials), VEP (visual evoked potentials), direct cortical stimulation. Also the train-of-four (TOF) stimulation is performed.The system is not intended to measure the vital signs. It records the data to be inter-preted by the neuromonitoring specialist. GWF,GWE,GWJ,OLT,PDQ Stimulator, Electrical, Evoked Response,Stimulator, Photic, Evoked Response,Stim Stimulator, Electrical, Evoked Response,Stimulator, Photic, Evoked Response,Stimulator, Auditory, Evoked Response,Non-Normalizing Quantitative Electroencephalograph Software,Neurosurgical Nerve Locator 2 Neuro-IOM
12 04650075330296 CloudTMS The CloudTMS system is indicated for the treatment of Major Depressive Disorder The CloudTMS system is indicated for the treatment of Major Depressive Disorder in adult patients who have failed to receive satisfactory improvement from prior antidepressant medications in the current episode. OBP Transcranial Magnetic Stimulator 2 CloudTMS
Other products with the same Product Code "DXH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00073796267902 BP7900 BP7900 Blood Pressure Monitor and single channel EKG device. Complete Blood Pressure Monitor +EKG OMRON HEALTHCARE, INC.
2 B635BIOFLUX1A0 1.0 BIOFLUX BIOTRICITY INC
3 B635BIOFLUX100 1.0 BIOFLUX BIOTRICITY INC
4 B287ECG01U0 ECG01-U ECG01-Universal The ECG Check is intended for self-testing by patients at home. This 1-leadcardi The ECG Check is intended for self-testing by patients at home. This 1-leadcardiac monitor allows remote patients to display and transmit their EGG data tomedical professionals via a communication device to a remote server.Specifically, the EGG Check is indicated for patients who are concerned abouttheir heart rhythm and have experienced the following symptoms that aresuggestive of abnormal heart rhythms:* Skipped Beats* Pounding Heart (Palpitations)* Heart Racing or Irregular Pulse* Lightheadedness or Faintness* History of ArrhythmiasPrescription ECG Check CARDIAC DESIGNS INC.
5 B210AC0210 AC-021 The AliveCor KardiaMobile Card System is a single-channel electrocardiogram (ECG The AliveCor KardiaMobile Card System is a single-channel electrocardiogram (ECG) device that is intended to record, store, transfer, display, and analyze single-channel ECG rhythms. KardiaMobile Card ALIVECOR, INC.
6 B210AC0190 AC-019 KardiaMobile 6L ALIVECOR, INC.
7 B210AC0090 AC-009 Kardia Mobile ALIVECOR, INC.
8 B147PACETRAKSPEAKS0 Pacetrak Plus rev 4 (PP4-Pacetrak Plus Speaks) Transmitters and Receivers, Electrocardiograph, Telephone Pacetrak Plus rev 4 UNIVERSAL MEDICAL, INC.
9 B147PACETRAKPLUSENR0 Pacetrak Plus Rev 5(PP5-Pactrak Plus ENR) Transmitters and Receivers, Electrocardiograph, Telephone Pacetrak Plus Rev 5 UNIVERSAL MEDICAL, INC.
10 B147HTSMW010 Heartrak Smart Wireless Rev 1 Transmitters and Receivers, Electrocardiograph, Telephone Heartrak Smart Wireless Rev 1 UNIVERSAL MEDICAL, INC.
11 B147HTSMAF50 Heartrak Smart AF Transmitters and Receivers, Electrocardiograph, Telephone Heartrak Smart AF UNIVERSAL MEDICAL, INC.
12 B147HTSM50 Heartrak Smart Rev 5 Transmitters and Receivers, Electrocardiograph, Telephone Heartrak Smart Rev 5 UNIVERSAL MEDICAL, INC.
13 B147HTECAT020 Heartrak ECAT 2 Transmitters and Receivers, Electrocardiograph, Telephone Heartrak ECAT 2 UNIVERSAL MEDICAL, INC.
14 B147HTECAT010 Heartrak ECAT Transmitters and Receivers, Electrocardiograph, Telephone Heartrak ECAT UNIVERSAL MEDICAL, INC.
15 B147HT20 Heartrak 2 Telephone electrocardiograph transmitter and receiver Heartrak 2 UNIVERSAL MEDICAL, INC.
16 B147FSAIR0 Fusion Air Transmitters and Receivers, Electrocardiograph, Telephone Fusion Air UNIVERSAL MEDICAL, INC.
17 B147EC0 eCardiostation Software Software with CardioStation eCardiostation Software UNIVERSAL MEDICAL, INC.
18 B147CSTTM010 CardioStation Transtelephonic Module Transmitters and Receivers, Electrocardiograph, Telephone Cardiostation Transtelephonic Module UNIVERSAL MEDICAL, INC.
19 B147CSS0 Cardiostation Standalone Software Cardiostation Software sold with wireless devices. Cardiostation Premier Stand Alone Software UNIVERSAL MEDICAL, INC.
20 B147CA0 Cardiostation® Advantage Software Cardiostation Software sold with TTM module. Cardiostation® Advantage Software UNIVERSAL MEDICAL, INC.
21 B14731160 Pacetrak Plus rev 3 (PP3) Transmitters and Receivers, Electrocardiograph, Telephone Pacetrak Plus rev 3 UNIVERSAL MEDICAL, INC.
22 B146ECAT2010 900-0623-01 ECAT2 Generic BRAEMAR MANUFACTURING, LLC
23 20856602005172 SPC-2520 NA PROTEUS DIGITAL HEALTH, INC.
24 15099169413334 4130 BT12 ECG AHA WITH SPIROTRAC 6 SOFTWARE ECG VITALOGRAPH (IRELAND) LIMITED
25 15099169413303 4130 BT-12 ECG IEC with SPIROTRAC 6 SOFTWARE ECG VITALOGRAPH (IRELAND) LIMITED
26 15099169413037 4130 BT-12 ECG USA ECG VITALOGRAPH (IRELAND) LIMITED
27 10856602005274 SPC-2232.B59 NA PROTEUS DIGITAL HEALTH, INC.
28 10856602005267 SPC-2232.B55 NA PROTEUS DIGITAL HEALTH, INC.
29 10856602005250 SPC-2232.B52 NA PROTEUS DIGITAL HEALTH, INC.
30 10856602005243 SPC-2232.B50 NA PROTEUS DIGITAL HEALTH, INC.
31 10856602005236 SPC-2232.B02 NA PROTEUS DIGITAL HEALTH, INC.
32 10856602005205 SPC-2032.B59 NA PROTEUS DIGITAL HEALTH, INC.
33 10856602005199 SPC-2032.B55 NA PROTEUS DIGITAL HEALTH, INC.
34 10856602005182 SPC-2032.B52 NA PROTEUS DIGITAL HEALTH, INC.
35 10856602005175 SPC-2032.B50 NA PROTEUS DIGITAL HEALTH, INC.
36 10856602005168 SPC-2032.B02 NA PROTEUS DIGITAL HEALTH, INC.
37 10856602005144 SPC-2008 Proteus Digital Health Feedback System PROTEUS DIGITAL HEALTH, INC.
38 10856602005120 SPC-1330.B59 NA PROTEUS DIGITAL HEALTH, INC.
39 10856602005113 SPC-1330.B50 NA PROTEUS DIGITAL HEALTH, INC.
40 10856602005106 SPC-1330.B55 NA PROTEUS DIGITAL HEALTH, INC.
41 10856602005090 SPC-1330.B02 NA PROTEUS DIGITAL HEALTH, INC.
42 10856602005083 SPC-1330.B52 NA PROTEUS DIGITAL HEALTH, INC.
43 10856602005076 SPC-0572.B50 NA PROTEUS DIGITAL HEALTH, INC.
44 10856602005069 SPC-0572.B59 NA PROTEUS DIGITAL HEALTH, INC.
45 10856602005052 SPC-0572.B55 NA PROTEUS DIGITAL HEALTH, INC.
46 10856602005045 SPC-0572.B52 NA PROTEUS DIGITAL HEALTH, INC.
47 10856602005021 SPC-0572.B02 NA PROTEUS DIGITAL HEALTH, INC.
48 10841522127212 98000; 98200; LCF 040-1760-00 PACKAGE, LIFECARD CF AND PATHFINDER SL LIFECARD CF and PATHFINDER SL SPACELABS HEALTHCARE (WASHINGTON), INC
49 10841522126048 EVENTREC 23-0059 PATIENT CABLE SINGLE CHANNEL, BLK/WHT, US CODE Spacelabs Healthcare SPACELABS HEALTHCARE (WASHINGTON), INC
50 10841522126031 EVENTREC 23-0051 PATIENT CABLE 2 CHANNEL, RED/YEL/GRN Spacelabs Healthcare SPACELABS HEALTHCARE (WASHINGTON), INC