Other products from "FUJIFILM CORPORATION"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04547410480665 DR-XD 3000 HOLDER4343 E A flat panel sensor holder used to mount a 17" x 17" flat panel sensor onto DR-XD 3000FX. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Flat panel sensor holder
2 04547410480658 DR-XD 3000 HOLDER3543 E A flat panel sensor holder used to mount a 14" x 17" flat panel sensor onto DR-XD 3000FX. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Flat panel sensor holder
3 04547410480641 DR-XD 3000 HOLDER2530 E A flat panel sensor holder used to mount a 10" x 12" flat panel sensor onto DR-XD 3000FX. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Flat panel sensor holder
4 04547410478631 DR-ID 1811 SE NON CE E The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVOIII C35i
5 04547410467710 DR-XD 3000 The DR-XD 3000 is a mobile C-arm system with detachable flat panel detector, whi The DR-XD 3000 is a mobile C-arm system with detachable flat panel detector, which is intended for use in providing medical imaging for general populations including pediatrics.The device provides pulsed fluoroscopic imaging of patients during diagnostic, interventional and surgical procedures and digital radiographic imaging.It is intended for use in procedures such as holangiography, endoscopic, urologic, orthopedic, neurologic, critical care, peripheral vascular, emergency room procedures.This device does not support cardiac procedures and is not intended for use in performing mammography. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 FDR CROSS
6 04547410445466 DR-ID 1811 SE E The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVOIII C35i
7 04547410426915 DR-ID 1802 SE E The DR-ID 1801SE and DR-ID 1802SE incorporate a GOS indirect panel. The indirect The DR-ID 1801SE and DR-ID 1802SE incorporate a GOS indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVOIII G43
8 04547410425505 DR-XD 1000 The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in g The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in general purposeradiography for generating radiographic images of human anatomy, including adult, pediatric, andneonatal exams. The DR-XD 1000 is not intended for mammography applications. IZL System, x-ray, mobile 2 FDR AQRO
9 04547410361360 DR-ID 1273 SE E The Wired/Wireless FDR ES (DR-ID1270) flat panel sensor system is intended to ca The Wired/Wireless FDR ES (DR-ID1270) flat panel sensor system is intended to capture for display radiographic images of human anatomy. It is intended for use in general projection radiographic applications including pediatric and neonatal exams wherever conventional film/screen or CR systems may be used. It is not intended for mammography, fluoroscopy, tomography, and angiography applications. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR ES C35
10 04547410339161 DR-XD 1000 The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in g The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in general purposeradiography for generating radiographic images of human anatomy, including adult, pediatric, andneonatal exams. The DR-XD 1000 is not intended for mammography applications. IZL System, x-ray, mobile 2 FDR AQRO
11 04547410242010 COMP PLATE AXILLA 8X20 HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 Compression plate for axilla radiography
12 04547410309324 DR-ID 1212 SE A E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II C43
13 04547410302745 COMP PLATE 18X24 S FS HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 18x24 comfort paddle (FS Small)
14 04547410297843 IR DUMMY CASSETTE FOR M MBL E Before moving the vehicle, be sure to turn off the FCR PRIMA Tm and insert the d Before moving the vehicle, be sure to turn off the FCR PRIMA Tm and insert the dummy cassette. MQB Solid state x-ray imager (flat panel/digital imager) 2 Dummy Cassette (For Mobile)
15 04547410290899 DR-ID 1200 AP-SE CBL E A cable used for connecting the flat panel sensor and the optional access point. A cable used for connecting the flat panel sensor and the optional access point. This cable is used for wired communication if wireless communication is not available. MQB Solid state x-ray imager (flat panel/digital imager) 2 SE communication cable
16 04547410241990 COMP PLATE SPOT 9X9 HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 Rectangular spot compression plate
17 04547410288971 DR-ID 1200 MP E A device supplying power to the flat panel sensor and connecting between theflat A device supplying power to the flat panel sensor and connecting between theflat panel sensor and the control cabinet. MQB Solid state x-ray imager (flat panel/digital imager) 2 Power supply unit*
18 04547410288957 DR-ID 1212 SE E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II C43
19 04547410270129 COMP PLATE 18X24 HIGH HA A E Compression plate MUE Full field digital,system,x-ray,mammographic 2 18x24 Compression plate (High)
20 04547410259056 DR-ID 600/601 MP A E Supplies the power to the flat panel sensor and connects the flat panel sensor a Supplies the power to the flat panel sensor and connects the flat panel sensor and the control cabinet. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 600MP
21 04547410250459 CR-IR 359 The FCR XL-2/FCR Aspire CRm (CR-IR 359) is equipment designed to read X-ray imag The FCR XL-2/FCR Aspire CRm (CR-IR 359) is equipment designed to read X-ray image information recorded on an imaging plate (IP). MQB Solid state x-ray imager (flat panel/digital imager) 2 FCR XL-2
22 04547410245042 DR-ID 612 SE E The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. T The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. The DR-ID 611SE, DR-ID 612SE and DR-ID 613SE incorporate a CsI indirect panel. There are six types of flat panel sensors: DR-ID 601SE, DR-ID 602SE, DR-ID 611SE, DR-ID 612SE and DR-ID 613SE (wireless/wired communication mode) and DR-ID 600SE (wired communication mode). MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO plus C43i
23 04547410242201 COMP PLATE LATERAL BIOPSY HA E Compression plate for Lateral Biopsy MUE Full field digital,system,x-ray,mammographic 2 Lateral compression plate
24 04547410242034 COMP PLATE MAG1.8 16X20 HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 Compression plate for magnifications
25 04547410222104 IR ADAPTER FOR IP 15X30CM E 47410-22210 Inserting the Fuji Imaging Plate ST-VI 15cmx30cm into the adapter to insert it i Inserting the Fuji Imaging Plate ST-VI 15cmx30cm into the adapter to insert it into 35cmx43cm cassette makes image reading in the Fuji Computed Radiography possible. MQB Solid state x-ray imager (flat panel/digital imager) 2 15X30 IP ADAPTER
26 04547410215373 IR DUMMY CASSETTE FOR MBL E Before moving the vehicle, be sure to turn off the FCR PRIMA T and insert the du Before moving the vehicle, be sure to turn off the FCR PRIMA T and insert the dummy cassette. MQB Solid state x-ray imager (flat panel/digital imager) 2 Dummy Cassette (For Mobile)
27 04547410211368 LATERAL NEEDLE STOPPER E E Adjust the depth that the needle is inserted. The slide stopper differs for each Adjust the depth that the needle is inserted. The slide stopper differs for each needle. Use a slide stopper that suits each type of needle being used. MUE Full field digital,system,x-ray,mammographic 2 Slide stopper E
28 04547410189988 CR-IR 391RU The FCR PRIMA II (CR-IR 391RU) is equipment designed to read X-ray image informa The FCR PRIMA II (CR-IR 391RU) is equipment designed to read X-ray image information recorded on an imaging plate (IP). MQB Solid state x-ray imager (flat panel/digital imager) 2 FCR PRIMA II
29 04547410181777 NEEDLE HOLDER EN E Holder to fix the Biopsy Needle MUE Full field digital,system,x-ray,mammographic 2 Needle holder E
30 04547410178678 DR-ID 600/601 MP E Supplies the power to the flat panel sensor and connects the flat panel sensor a Supplies the power to the flat panel sensor and connects the flat panel sensor and the control cabinet. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 600MP
31 04547410143140 NEEDLE GUIDE C 18G E This guide is used for the CNB and FNA type needles and the hook wire. MUE Full field digital,system,x-ray,mammographic 2 Needle guide C-L/C-S (18G)
32 04547410143119 NEEDLE HOLDER M 8G E Holder to fix the Biopsy Needle MUE Full field digital,system,x-ray,mammographic 2 Needle holder M8
33 04547410091946 AXILLA PAD LEFT E Axilla pad help relieve discomfort of the patient when she is positioned for exposure. MUE Full field digital,system,x-ray,mammographic 2 Axilla pad L
34 04547410457704 DR-ID 800 IU DV3 E DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting on the Mobile Cart and employs an indirect-conversion FPD. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO Mobile Compo
35 04547410436716 DR-ID 1212 SE W SDK E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1212SE
36 04547410436709 DR-ID 1211 SE W SDK E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1211SE
37 04547410359886 COMP PLATE 24X30 HIGH HA USA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 24x30 Compression plate (High)
38 04547410355420 DR1270 SE BATTERY E A battery pack for the flat panel sensor. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR ES Battery Pack
39 04547410333527 DR-ID800CL The Console is a workstation intended to associate digital (for DR) images with The Console is a workstation intended to associate digital (for DR) images with patient and exam information, apply image processing to facilitate diagnosis, display the image, and output the resulting image and exam data for further display, distribution, or archiving. LLZ System, image processing, radiological 2 DR-ID800CL
40 04547410308532 DR-ID 1212 SE W E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1212SE
41 04547410308525 DR-ID 1211 SE W E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1211SE
42 04547410308402 DR-ID 800 IU DV2 E DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting on the Mobile Cart and employs an indirect-conversion FPD. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO Mobile Compo
43 04547410308211 DR-ID 1201 SE A E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II G35
44 04547410289015 DR-ID 1200 MC UNIT E A personal computer used for controlling the flat panel sensor and performing im A personal computer used for controlling the flat panel sensor and performing image processing. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1200MC
45 04547410288995 DR-ID 1200 MC SOFT E A personal computer used for controlling the flat panel sensor and performing im A personal computer used for controlling the flat panel sensor and performing image processing. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1200MC
46 04547410288803 DR-ID 1201 SE E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II G35
47 04547410270112 COMP PLATE 18X24 LOW HA A E Compression plate MUE Full field digital,system,x-ray,mammographic 2 18x24 Compression plate (Low)
48 04547410249965 DR 3500 TOMO FACE GUARD E Face Guard MUE Full field digital,system,x-ray,mammographic 2 Face Guard T
49 04547410235944 DR-ID 601 SE A E The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. T The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. The DR-ID 611SE, DR-ID 612SE and DR-ID 613SE incorporate a CsI indirect panel. There are six types of flat panel sensors: DR-ID 601SE, DR-ID 602SE, DR-ID 611SE, DR-ID 612SE and DR-ID 613SE (wireless/wired communication mode) and DR-ID 600SE (wired communication mode). MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO G35i
50 04547410220667 CR-IR 363 The FUJI Computed Radiography System FCR ClearView CS Plus/CSm Plus performs Dig The FUJI Computed Radiography System FCR ClearView CS Plus/CSm Plus performs Digital Radiography by using an Imaging Plate (IP) as the X-ray detection device. MQB Solid state x-ray imager (flat panel/digital imager) 2 FCR ClearView CS Plus
Other products with the same Product Code "FDS"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 06945868605186 EG-550 EG-550 Video Gastroscope SonoScape SONOSCAPE MEDICAL CORP.
2 06945868603434 EG-550L EG-550L Video Gastroscope SonoScape SONOSCAPE MEDICAL CORP.
3 05707480148172 483001000US 483001000US aScope Gastro (US version) aScopeā„¢ Gastro AMBU A/S
4 04961333251773 EG17-J10 PENTAX Medical Video Upper GI Scope EG17-J10 N/A HOYA CORPORATION
5 04961333248483 EG29-i10c Made in Malaysia IMAGINA HOYA CORPORATION
6 04961333248315 EG29-i10 Made in Malaysia N/A HOYA CORPORATION
7 04961333248179 EG-2990i Made in Malaysia N/A HOYA CORPORATION
8 04961333247387 EG29-i10c IMAGINA HOYA CORPORATION
9 04961333245888 EG34-i10 N/A HOYA CORPORATION
10 04961333244683 EG29-V10C VIDEO GASTROSCOPE - PTAH VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
11 04961333244676 EG27-V10C VIDEO GASTROSCOPE - PTAH VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
12 04961333244591 EG29-V10C VIDEO GASTROSCOPE - PTAH (USED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
13 04961333244584 EG27-V10C VIDEO GASTROSCOPE - PTAH (USED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
14 04961333244171 OF-Z5K STANDARD BITE BLOCKS, 3 PIECES N/A PENTAX OF AMERICA, INC.
15 04961333243389 KUMOF-B173K SEAL,CHAN INLET,RBBR 10PCS (STD) N/A PENTAX OF AMERICA, INC.
16 04961333243372 KUMOF-B118K CAP,CONNECTOR FOR WATER JET,5 PIECES FOR N/A PENTAX OF AMERICA, INC.
17 04961333242917 EG34-I10 VIDEO GASTROSCOPE VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
18 04961333240470 VSB-2990I VIDEO SMALL BOWEL ENTEROSCOPE (USED) ENTEROSCOPE PENTAX OF AMERICA, INC.
19 04961333240173 EG34-I10 VIDEO GASTROSCOPE (USED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
20 04961333240166 EG-2990ZI VIDEO GASTROSCOPE VERSION-C (USED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
21 04961333240159 EG16-K10 VIDEO GASTROSCOPE (USED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
22 04961333232925 VSB-3430K SMBOWEL ENTEROSCOPE 3.8C 11.6T 2200L FWJ (REFURBISHED) ENTEROSCOPE PENTAX OF AMERICA, INC.
23 04961333232574 EG-3890TK VIDEO GASTROSCOPE 3.8C 2.8C 12.8T FWJ (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
24 04961333232543 EG-3490K VIDEO GASTROSCOPE 3.8C 11.6T 1050L FWJ (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
25 04961333232536 EG29-I10 VIDEO GASTROSCOPE - I10 STANDARD (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
26 04961333232529 EG-2990K VIDEO GASTROSCOPE 2.8C 9.8T 1050L (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
27 04961333232512 EG-2990I HD VIDEO GASTROSCOPE 2.8C 9.8T 1050L (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
28 04961333232505 EG-2930Q VIDEO GASTROSCOPE (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
29 04961333232499 EG-290KP VIDEO GASTROSCOPE (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
30 04961333232482 EG27-I10 VIDEO GASTROSCOPE - I10 SLIM (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
31 04961333232475 EG-2790K VIDEO GASTROSCOPE 2.8C 9.0T 1050L (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
32 04961333232468 EG-2790I HD VIDEO GASTROSCOPE 2.8C 9.0T 1050L (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
33 04961333232451 EG-2490K VIDEO GASTROSCOPE 2.4C 8.0T 1050L (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
34 04961333232444 EG-1690K VIDEO GASTROSCOPE 2.0C 5.4T 1050L (REFURBISHED) VIDEO GASTROSCOPE PENTAX OF AMERICA, INC.
35 04961333232437 EE-1580K VIDEO ESOPHAGOSCOPE (REFURBISHED) VIDEO ESOPHAGOSCOPE PENTAX OF AMERICA, INC.
36 04961333228584 FG-29V Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
37 04961333228492 EG-2990K Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
38 04961333228478 EG-2990i Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
39 04961333228324 EE-1580K Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
40 04961333227686 VSB-3430K Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
41 04961333227099 EG-3890TK Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
42 04961333227044 EG-3490K Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
43 04961333225743 EG-1690K Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
44 04961333225712 EG-2790K Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
45 04961333225651 EG-2490K Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
46 04961333225026 EG-2790i Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
47 04961333224913 EG-290Kp Perform cleaning, high-level disinfection, and/or sterilization according to the Perform cleaning, high-level disinfection, and/or sterilization according to the procedure specified in the Instructions for Use (Reprocessing) of this instrument. PENTAX HOYA CORPORATION
48 04961333224708 KW3122S PENTAX HOYA CORPORATION
49 04961333224685 KW3115S PENTAX HOYA CORPORATION
50 04961333224661 KW3111S PENTAX HOYA CORPORATION