Other products from "FUJIFILM CORPORATION"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04547410480665 DR-XD 3000 HOLDER4343 E A flat panel sensor holder used to mount a 17" x 17" flat panel sensor onto DR-XD 3000FX. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Flat panel sensor holder
2 04547410480658 DR-XD 3000 HOLDER3543 E A flat panel sensor holder used to mount a 14" x 17" flat panel sensor onto DR-XD 3000FX. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Flat panel sensor holder
3 04547410480641 DR-XD 3000 HOLDER2530 E A flat panel sensor holder used to mount a 10" x 12" flat panel sensor onto DR-XD 3000FX. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Flat panel sensor holder
4 04547410478631 DR-ID 1811 SE NON CE E The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVOIII C35i
5 04547410467710 DR-XD 3000 The DR-XD 3000 is a mobile C-arm system with detachable flat panel detector, whi The DR-XD 3000 is a mobile C-arm system with detachable flat panel detector, which is intended for use in providing medical imaging for general populations including pediatrics.The device provides pulsed fluoroscopic imaging of patients during diagnostic, interventional and surgical procedures and digital radiographic imaging.It is intended for use in procedures such as holangiography, endoscopic, urologic, orthopedic, neurologic, critical care, peripheral vascular, emergency room procedures.This device does not support cardiac procedures and is not intended for use in performing mammography. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 FDR CROSS
6 04547410445466 DR-ID 1811 SE E The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel The DR-ID 1811SE, DR-ID 1812SE and DR-ID 1814SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVOIII C35i
7 04547410426915 DR-ID 1802 SE E The DR-ID 1801SE and DR-ID 1802SE incorporate a GOS indirect panel. The indirect The DR-ID 1801SE and DR-ID 1802SE incorporate a GOS indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVOIII G43
8 04547410425505 DR-XD 1000 The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in g The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in general purposeradiography for generating radiographic images of human anatomy, including adult, pediatric, andneonatal exams. The DR-XD 1000 is not intended for mammography applications. IZL System, x-ray, mobile 2 FDR AQRO
9 04547410361360 DR-ID 1273 SE E The Wired/Wireless FDR ES (DR-ID1270) flat panel sensor system is intended to ca The Wired/Wireless FDR ES (DR-ID1270) flat panel sensor system is intended to capture for display radiographic images of human anatomy. It is intended for use in general projection radiographic applications including pediatric and neonatal exams wherever conventional film/screen or CR systems may be used. It is not intended for mammography, fluoroscopy, tomography, and angiography applications. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR ES C35
10 04547410339161 DR-XD 1000 The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in g The DR-XD 1000 (FDR AQRO) is a digital mobile X-ray system intended for use in general purposeradiography for generating radiographic images of human anatomy, including adult, pediatric, andneonatal exams. The DR-XD 1000 is not intended for mammography applications. IZL System, x-ray, mobile 2 FDR AQRO
11 04547410242010 COMP PLATE AXILLA 8X20 HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 Compression plate for axilla radiography
12 04547410309324 DR-ID 1212 SE A E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II C43
13 04547410302745 COMP PLATE 18X24 S FS HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 18x24 comfort paddle (FS Small)
14 04547410297843 IR DUMMY CASSETTE FOR M MBL E Before moving the vehicle, be sure to turn off the FCR PRIMA Tm and insert the d Before moving the vehicle, be sure to turn off the FCR PRIMA Tm and insert the dummy cassette. MQB Solid state x-ray imager (flat panel/digital imager) 2 Dummy Cassette (For Mobile)
15 04547410290899 DR-ID 1200 AP-SE CBL E A cable used for connecting the flat panel sensor and the optional access point. A cable used for connecting the flat panel sensor and the optional access point. This cable is used for wired communication if wireless communication is not available. MQB Solid state x-ray imager (flat panel/digital imager) 2 SE communication cable
16 04547410241990 COMP PLATE SPOT 9X9 HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 Rectangular spot compression plate
17 04547410288971 DR-ID 1200 MP E A device supplying power to the flat panel sensor and connecting between theflat A device supplying power to the flat panel sensor and connecting between theflat panel sensor and the control cabinet. MQB Solid state x-ray imager (flat panel/digital imager) 2 Power supply unit*
18 04547410288957 DR-ID 1212 SE E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II C43
19 04547410270129 COMP PLATE 18X24 HIGH HA A E Compression plate MUE Full field digital,system,x-ray,mammographic 2 18x24 Compression plate (High)
20 04547410259056 DR-ID 600/601 MP A E Supplies the power to the flat panel sensor and connects the flat panel sensor a Supplies the power to the flat panel sensor and connects the flat panel sensor and the control cabinet. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 600MP
21 04547410250459 CR-IR 359 The FCR XL-2/FCR Aspire CRm (CR-IR 359) is equipment designed to read X-ray imag The FCR XL-2/FCR Aspire CRm (CR-IR 359) is equipment designed to read X-ray image information recorded on an imaging plate (IP). MQB Solid state x-ray imager (flat panel/digital imager) 2 FCR XL-2
22 04547410245042 DR-ID 612 SE E The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. T The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. The DR-ID 611SE, DR-ID 612SE and DR-ID 613SE incorporate a CsI indirect panel. There are six types of flat panel sensors: DR-ID 601SE, DR-ID 602SE, DR-ID 611SE, DR-ID 612SE and DR-ID 613SE (wireless/wired communication mode) and DR-ID 600SE (wired communication mode). MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO plus C43i
23 04547410242201 COMP PLATE LATERAL BIOPSY HA E Compression plate for Lateral Biopsy MUE Full field digital,system,x-ray,mammographic 2 Lateral compression plate
24 04547410242034 COMP PLATE MAG1.8 16X20 HA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 Compression plate for magnifications
25 04547410222104 IR ADAPTER FOR IP 15X30CM E 47410-22210 Inserting the Fuji Imaging Plate ST-VI 15cmx30cm into the adapter to insert it i Inserting the Fuji Imaging Plate ST-VI 15cmx30cm into the adapter to insert it into 35cmx43cm cassette makes image reading in the Fuji Computed Radiography possible. MQB Solid state x-ray imager (flat panel/digital imager) 2 15X30 IP ADAPTER
26 04547410215373 IR DUMMY CASSETTE FOR MBL E Before moving the vehicle, be sure to turn off the FCR PRIMA T and insert the du Before moving the vehicle, be sure to turn off the FCR PRIMA T and insert the dummy cassette. MQB Solid state x-ray imager (flat panel/digital imager) 2 Dummy Cassette (For Mobile)
27 04547410211368 LATERAL NEEDLE STOPPER E E Adjust the depth that the needle is inserted. The slide stopper differs for each Adjust the depth that the needle is inserted. The slide stopper differs for each needle. Use a slide stopper that suits each type of needle being used. MUE Full field digital,system,x-ray,mammographic 2 Slide stopper E
28 04547410189988 CR-IR 391RU The FCR PRIMA II (CR-IR 391RU) is equipment designed to read X-ray image informa The FCR PRIMA II (CR-IR 391RU) is equipment designed to read X-ray image information recorded on an imaging plate (IP). MQB Solid state x-ray imager (flat panel/digital imager) 2 FCR PRIMA II
29 04547410181777 NEEDLE HOLDER EN E Holder to fix the Biopsy Needle MUE Full field digital,system,x-ray,mammographic 2 Needle holder E
30 04547410178678 DR-ID 600/601 MP E Supplies the power to the flat panel sensor and connects the flat panel sensor a Supplies the power to the flat panel sensor and connects the flat panel sensor and the control cabinet. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 600MP
31 04547410143140 NEEDLE GUIDE C 18G E This guide is used for the CNB and FNA type needles and the hook wire. MUE Full field digital,system,x-ray,mammographic 2 Needle guide C-L/C-S (18G)
32 04547410143119 NEEDLE HOLDER M 8G E Holder to fix the Biopsy Needle MUE Full field digital,system,x-ray,mammographic 2 Needle holder M8
33 04547410091946 AXILLA PAD LEFT E Axilla pad help relieve discomfort of the patient when she is positioned for exposure. MUE Full field digital,system,x-ray,mammographic 2 Axilla pad L
34 04547410457704 DR-ID 800 IU DV3 E DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting on the Mobile Cart and employs an indirect-conversion FPD. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO Mobile Compo
35 04547410436716 DR-ID 1212 SE W SDK E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1212SE
36 04547410436709 DR-ID 1211 SE W SDK E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1211SE
37 04547410359886 COMP PLATE 24X30 HIGH HA USA E Compression plate MUE Full field digital,system,x-ray,mammographic 2 24x30 Compression plate (High)
38 04547410355420 DR1270 SE BATTERY E A battery pack for the flat panel sensor. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR ES Battery Pack
39 04547410333527 DR-ID800CL The Console is a workstation intended to associate digital (for DR) images with The Console is a workstation intended to associate digital (for DR) images with patient and exam information, apply image processing to facilitate diagnosis, display the image, and output the resulting image and exam data for further display, distribution, or archiving. LLZ System, image processing, radiological 2 DR-ID800CL
40 04547410308532 DR-ID 1212 SE W E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1212SE
41 04547410308525 DR-ID 1211 SE W E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1211SE
42 04547410308402 DR-ID 800 IU DV2 E DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting DR-ID 800 (FDR D-EVO Mobile Compo) is digital radiography equipment for mounting on the Mobile Cart and employs an indirect-conversion FPD. MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO Mobile Compo
43 04547410308211 DR-ID 1201 SE A E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II G35
44 04547410289015 DR-ID 1200 MC UNIT E A personal computer used for controlling the flat panel sensor and performing im A personal computer used for controlling the flat panel sensor and performing image processing. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1200MC
45 04547410288995 DR-ID 1200 MC SOFT E A personal computer used for controlling the flat panel sensor and performing im A personal computer used for controlling the flat panel sensor and performing image processing. MQB Solid state x-ray imager (flat panel/digital imager) 2 DR-ID 1200MC
46 04547410288803 DR-ID 1201 SE E The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 12 The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel. The DR-ID 1211SE, DR-ID 1212SE and DR-ID 1213SE incorporate a CsI indirect panel. The indirect-conversion flat panel sensor is a device which acquires a general radiograph. MQB Solid state x-ray imager (flat panel/digital imager) 2 D-EVO II G35
47 04547410270112 COMP PLATE 18X24 LOW HA A E Compression plate MUE Full field digital,system,x-ray,mammographic 2 18x24 Compression plate (Low)
48 04547410249965 DR 3500 TOMO FACE GUARD E Face Guard MUE Full field digital,system,x-ray,mammographic 2 Face Guard T
49 04547410235944 DR-ID 601 SE A E The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. T The DR-ID 600SE, DR-ID 601SE and DR-ID 602SE incorporate a GOS indirect panel. The DR-ID 611SE, DR-ID 612SE and DR-ID 613SE incorporate a CsI indirect panel. There are six types of flat panel sensors: DR-ID 601SE, DR-ID 602SE, DR-ID 611SE, DR-ID 612SE and DR-ID 613SE (wireless/wired communication mode) and DR-ID 600SE (wired communication mode). MQB Solid state x-ray imager (flat panel/digital imager) 2 FDR D-EVO G35i
50 04547410220667 CR-IR 363 The FUJI Computed Radiography System FCR ClearView CS Plus/CSm Plus performs Dig The FUJI Computed Radiography System FCR ClearView CS Plus/CSm Plus performs Digital Radiography by using an Imaging Plate (IP) as the X-ray detection device. MQB Solid state x-ray imager (flat panel/digital imager) 2 FCR ClearView CS Plus
Other products with the same Product Code "MUE"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 06430035430079 Clarity Planmed Clarity is a mammographic x-ray unit intended for diagnosis of breast cancer Planmed PLANMED OY
2 06430035430024 Nuance Excel Planmed Nuance Excel is a mammographic x-ray unit intended for diagnosis of brea Planmed Nuance Excel is a mammographic x-ray unit intended for diagnosis of breast cancer. Planmed PLANMED OY
3 05414904050385 5170/200 E4YW2 DX-M DIGITIZER DX-M AGFA
4 05414904044179 CR HD5.0 AEC CASSETTE 18X24 5PCT2 CR HD5.0 AEC CASSETTE 18X24CM CR HD5.0 AEC CASSETTE AGFA
5 05414904044162 CR HD5.0 AEC CASSETTE 24X30 5PCSZ CR HD5.0 AEC CASSETTE 24X30CM CR HD5.0 AEC CASSETTE AGFA
6 05414904044155 CR HD5.0 AEC CASSETTE 35X43 5PCQV CR HD5.0 AEC CASSETTE 35X43CM CR HD5.0 AEC CASSETTE AGFA
7 04547410465648 COMP PLATE SPOT 18X24 HA USA E Compression plate 18x24 Spot compression plate FUJIFILM CORPORATION
8 04547410373363 DR 3500 FACE GUARD T COMFORT E Face Guard Face guard T Comfort FUJIFILM CORPORATION
9 04547410359886 COMP PLATE 24X30 HIGH HA USA E Compression plate 24x30 Compression plate (High) FUJIFILM CORPORATION
10 04547410354584 DR 3500 MBL KIT HA USA E Optional parts to protect the FDR MS-3500 from vibration and shock when it is mo Optional parts to protect the FDR MS-3500 from vibration and shock when it is mounted on a vehicle. Vehicle-monted option FUJIFILM CORPORATION
11 04547410347517 NEEDLE GUIDE C 12G E This guide is used for the CNB and FNA type needles and the hook wire. Needle guide 12G (C-L,C-S) FUJIFILM CORPORATION
12 04547410336047 POSITIONER KIT BPY-L HA USA E The FDR-2000BPY provides the function that calculates the three-dimensional coor The FDR-2000BPY provides the function that calculates the three-dimensional coordinates of the image obtained from an exposure and supports the positioning of the needle using the coordinates. FDR-2000BPY FUJIFILM CORPORATION
13 04547410327359 LATERAL BIOPSY KIT HA USA E When the Lateral Approach Kit is installed onto the FDR-2000BPY positioner, it d When the Lateral Approach Kit is installed onto the FDR-2000BPY positioner, it determines and retains the position of needle insertion in the vertical direction (90 degree, -90 degree) in relation to the direction of breast compression. Lateral Approach Kit FUJIFILM CORPORATION
14 04547410327342 POSITIONER KIT BPSY HA USA E The FDR-2000BPY provides the function that calculates the three-dimensional coor The FDR-2000BPY provides the function that calculates the three-dimensional coordinates of the image obtained from an exposure and supports the positioning of the needle using the coordinates. FDR-2000BPY FUJIFILM CORPORATION
15 04547410316902 FDR-3000AWS FDR-3000AWS is a workstation used for Mammography System, intended to associate FDR-3000AWS is a workstation used for Mammography System, intended to associate digital mammography images with patient and exam information, apply image processing to facilitate diagnosis, display the image,and output the resulting image and exam data for further display, distribution, or archiving. AWS-h FUJIFILM CORPORATION
16 04547410307269 1SHOT PHANTOM 24X30 HA E 1 Shot Phantom M Plus is used for quality control of digital mammography systems. 1Shot Phantom M Plus 24x30 FUJIFILM CORPORATION
17 04547410302745 COMP PLATE 18X24 S FS HA E Compression plate 18x24 comfort paddle (FS Small) FUJIFILM CORPORATION
18 04547410297546 DR 3500 W 24X30 USA + E The Fujifilm Digital Mammography Systems, ASPIRE Cristalle (FDR MS-3500) generat The Fujifilm Digital Mammography Systems, ASPIRE Cristalle (FDR MS-3500) generates full-field digital mammography images that can, as other full-field digital mammography systems, be used for screening and diagnosis of breast cancer and is intended for use in the same clinical applications as traditional screen-film mammography systems. ASPIRE Cristalle FUJIFILM CORPORATION
19 04547410293326 LATERAL ATTACHMENT FOR M RE E This kit is used in combination with Mammotome Revolve. Mammotome Revolve® lateral kit FUJIFILM CORPORATION
20 04547410293302 ATTACHMENT FOR M RE E This kit is used in combination with Mammotome Revolve. Mammotome Revolve® kit FUJIFILM CORPORATION
21 04547410287080 COMP PLATE ROUND MAG SPOT HA E Compression plate Round spot magnification compression plate FUJIFILM CORPORATION
22 04547410287066 COMP PLATE ROUND SPOT HA E Compression plate Round spot compression plate FUJIFILM CORPORATION
23 04547410270150 COMP PLATE 24X30 SMALL HA A E Compression plate 24x30 compression plate (Shift) FUJIFILM CORPORATION
24 04547410270143 COMP PLATE 18X24 SMALL HA A E Compression plate 18x24 compression plate (Small) FUJIFILM CORPORATION
25 04547410270136 COMP PLATE 24X30 LOW HA A E Compression plate 24x30 Compression plate (Low) FUJIFILM CORPORATION
26 04547410270129 COMP PLATE 18X24 HIGH HA A E Compression plate 18x24 Compression plate (High) FUJIFILM CORPORATION
27 04547410270112 COMP PLATE 18X24 LOW HA A E Compression plate 18x24 Compression plate (Low) FUJIFILM CORPORATION
28 04547410266078 NEEDLE HOLDER H EV E To use the Eviva needle, attach this spacer between the needle holder M and the To use the Eviva needle, attach this spacer between the needle holder M and the Eviva adapter. Eviva® spacer FUJIFILM CORPORATION
29 04547410249965 DR 3500 TOMO FACE GUARD E Face Guard Face Guard T FUJIFILM CORPORATION
30 04547410247886 COMP PLATE 24X30 FS HA E Compression plate 24x30H comfort paddle (FS) FUJIFILM CORPORATION
31 04547410247862 COMP PLATE 18X24 FS HA E Compression plate 18x24L comfort paddle (FS) FUJIFILM CORPORATION
32 04547410245066 COMP PLATE BIOPSY HA E Compression plate for Biopsy Biopsy compression plate FUJIFILM CORPORATION
33 04547410242201 COMP PLATE LATERAL BIOPSY HA E Compression plate for Lateral Biopsy Lateral compression plate FUJIFILM CORPORATION
34 04547410242171 COMP PLATE 24X30 SSMALL HA E Compression plate 24x30 compression plate (Shift Small) FUJIFILM CORPORATION
35 04547410242157 COMP PLATE 24X30 FLEX HA E Compression plate 24x30H compression plate (Flex) FUJIFILM CORPORATION
36 04547410242133 COMP PLATE 18X24 FLEX HA E Compression plate 18x24L compression plate (Flex) FUJIFILM CORPORATION
37 04547410242072 COMP PLATE MAGSPOT 9X9 HA E Compression plate Rectangle spot magnification compression plate FUJIFILM CORPORATION
38 04547410242058 COMP PLATE 2D BIOPSY HA E Compression plate for 2D Biopsy 2D biopsy compression plate FUJIFILM CORPORATION
39 04547410242034 COMP PLATE MAG1.8 16X20 HA E Compression plate Compression plate for magnifications FUJIFILM CORPORATION
40 04547410242010 COMP PLATE AXILLA 8X20 HA E Compression plate Compression plate for axilla radiography FUJIFILM CORPORATION
41 04547410241990 COMP PLATE SPOT 9X9 HA E Compression plate Rectangular spot compression plate FUJIFILM CORPORATION
42 04547410241914 MAG TABLE HA E Using the magnification table enables 1.8 times magnified mammographic images to Using the magnification table enables 1.8 times magnified mammographic images to be obtained. Magnification table FUJIFILM CORPORATION
43 04547410217995 NEEDLE GUIDE COVER 10 E Fixing covers of Needle Guide Needle guide cover 10 FUJIFILM CORPORATION
44 04547410211368 LATERAL NEEDLE STOPPER E E Adjust the depth that the needle is inserted. The slide stopper differs for each Adjust the depth that the needle is inserted. The slide stopper differs for each needle. Use a slide stopper that suits each type of needle being used. Slide stopper E FUJIFILM CORPORATION
45 04547410211351 LATERAL NEEDLE STOPPER V E Adjust the depth that the needle is inserted. The slide stopper differs for each Adjust the depth that the needle is inserted. The slide stopper differs for each needle. Use a slide stopper that suits each type of needle being used. Slide stopper V FUJIFILM CORPORATION
46 04547410211344 LATERAL NEEDLE STOPPER C E Adjust the depth that the needle is inserted. The slide stopper differs for each Adjust the depth that the needle is inserted. The slide stopper differs for each needle. Use a slide stopper that suits each type of needle being used. Slide stopper C FUJIFILM CORPORATION
47 04547410211337 LATERAL NEEDLE STOPPER M E Adjust the depth that the needle is inserted. The slide stopper differs for each Adjust the depth that the needle is inserted. The slide stopper differs for each needle. Use a slide stopper that suits each type of needle being used. Slide stopper M FUJIFILM CORPORATION
48 04547410211221 NEEDLE GUIDE COVER E Fixing cover of Needle Guide Needle guide cover FUJIFILM CORPORATION
49 04547410211214 NEEDLE GUIDE TEST E This guide is used for the Position accuracy check needle. Needle guide TEST FUJIFILM CORPORATION
50 04547410211207 LATERAL NEEDLE STOPPER TEST E Adjust the depth that the needle is inserted. The slide stopper differs for each Adjust the depth that the needle is inserted. The slide stopper differs for each needle. Use a slide stopper that suits each type of needle being used. Slide stopper TEST FUJIFILM CORPORATION