The KAWASUMI Multiple Sample Adapter with Pre-attached Holder is a sterile, sing
The KAWASUMI Multiple Sample Adapter with Pre-attached Holder is a sterile, single use device consisting of a plastic holder with a non-patientcontacting stainless steel cannula covered with a rubber sheath and a male luer adapter which is attached into the holder. This device is used tocollect blood specimen by connecting to female luer connectors of vascular access devices such as peripheral, central catheter, Huberneedle, etc. When blood is collected, the blood collection tube is placed over the cannula, pushing the rubber sheath back, allowing blood flow.When the blood collection tube is removed, the rubber sheath extends back over the cannula and stopping blood flow.
The SB Knife is a single-patient use EtO-sterilized hand-held device that connec
The SB Knife is a single-patient use EtO-sterilized hand-held device that connects to an external high frequency (HF) generator and is designed to be used with Olympus and ERBE Electrosurgical monopolar HF generators, connectors and patient grounding plates to cut tissue including Zenker’s diverticulum within the digestive tract using high-frequency current. Varying generator power, cycle and duration results in a control of these surgical capabilities. The SB Knife is designed to connect with Olympus and ERBE connectors and uses the disposable or reusable Olympus or ERBE grounding plates and connecting cables intended for the generators.The device is not life supporting or life sustaining. It is designed as a short-term limited contact device (less than 24 hours), has no software, and has been certified to comply with IEC 60601-1 and IEC 60601-2-2 and IEC 60601-2-18 by UL Japan.
KNS
Unit, Electrosurgical, Endoscopic (With Or Without Accessories)
This Product is a device used as a heart positioner particularly for Off-Pump CA
This Product is a device used as a heart positioner particularly for Off-Pump CABG (Coronary Artery Bypass Grafting). Three (3) Suction Cups are attached to the surface of the heart by means of suction pressure applied to each one of them. Traction Tubes are pulled and clamped to the surgical drape by Forceps in order to fix the position of the heart.
This Product is a device used as a heart positioner particularly for Off-Pump CA
This Product is a device used as a heart positioner particularly for Off-Pump CABG (Coronary Artery Bypass Grafting). Three (3) Suction Cups are attached to the surface of the heart by means of suction pressure applied to each one of them. Traction Tubes are pulled and clamped to the surgical drape by Forceps in order to fix the position of the heart.
Flexible Overtube provides an access for repeated insertion and withdrawal of an
Flexible Overtube provides an access for repeated insertion and withdrawal of an endoscope for tissue or foreign body retrieval, and/or for endoscopic procedures requiring multiple endoscope intubations. Flexible Overtube consists of an overtube with a coiled stainless steel skelton, a detachable seal unit for an endoscope, and a detachable mouthpiece for a patient. The steel skelton of the overtube prevents the overtube from being bent and collapsed while keeping flexibility of the overtube. The detachable seal unit named “AD rubber unit” can be attached to the proximal end of the overtube to maintain insufflation and minimize leakage of air during endoscopic treatment. The overtube can be locked with the mouthpiece to maintain the proper placement of the overtube.
The Product is a transparent distal attachment applied to the tip of the endosco
The Product is a transparent distal attachment applied to the tip of the endoscope. It is used in ESD procedures. This Product is used for maintaining visualization during the dissection phase of the procedure. This Product contains drainage side hole that allows egress of water and blood. This Product is disposable and in a variety of diameters that correspond to different endoscope sizes.
The Product is a transparent distal attachment applied to the tip of the endosco
The Product is a transparent distal attachment applied to the tip of the endoscope. It is used in ESD procedures. This Product is used for maintaining visualization during the dissection phase of the procedure. This Product contains drainage side hole that allows egress of water and blood. This Product is disposable and in a variety of diameters that correspond to different endoscope sizes.
The Product is a transparent distal attachment applied to the tip of the endosco
The Product is a transparent distal attachment applied to the tip of the endoscope. It is used in ESD procedures. This Product is used for maintaining visualization during the dissection phase of the procedure. This Product contains drainage side hole that allows egress of water and blood. This Product is disposable and in a variety of diameters that correspond to different endoscope sizes.
The Product is a transparent distal attachment applied to the tip of the endosco
The Product is a transparent distal attachment applied to the tip of the endoscope. It is used in ESD procedures. This Product is used for maintaining visualization during the dissection phase of the procedure. This Product contains drainage side hole that allows egress of water and blood. This Product is disposable and in a variety of diameters that correspond to different endoscope sizes.
The Product is a transparent distal attachment applied to the tip of the endosco
The Product is a transparent distal attachment applied to the tip of the endoscope. It is used in ESD procedures. This Product is used for maintaining visualization during the dissection phase of the procedure. This Product contains drainage side hole that allows egress of water and blood. This Product is disposable and in a variety of diameters that correspond to different endoscope sizes.
The Product is a transparent distal attachment applied to the tip of the endosco
The Product is a transparent distal attachment applied to the tip of the endoscope. It is used in ESD procedures. This Product is used for maintaining visualization during the dissection phase of the procedure. This Product contains drainage side hole that allows egress of water and blood. This Product is disposable and in a variety of diameters that correspond to different endoscope sizes.
A mains electricity-powered (AC-powered) component of a microwave ablation/elect
A mains electricity-powered (AC-powered) component of a microwave ablation/electrosurgical system intended to generate both: 1) radio-frequency (RF) electrical current; and 2) microwave energy for subsequent cutting, coagulation, and ablation of soft tissues during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues. It includes controls, may include an integrated surgical plume (smoke) suction unit, and is intended to be connected via a cable to an electrosurgical handpiece and electrode (neither of these are included); it is not intended for argon-enhanced electrosurgery.
HS1 is indicated for use in endoscopic injection therapy (to deliver pharmacolog
HS1 is indicated for use in endoscopic injection therapy (to deliver pharmacological injection agents, such as vasoconstrictors) and endoscopic electrohemostasis (cauterization of tissue and coagulation of blood) of actual or potential bleeding sites in the gastrointestinal tract. These sites will include the following• Peptic Ulcers• Dieulafoy Lesions• Mallory-Weiss Tears• Bleeding Polyp Stalks• Arteriovenous Malformations (AVMs)• AngiomataThe HS1 also has irrigation capability. Any other use is not recommended.
A mains electricity-powered (AC-powered) component of a microwave ablation/elect
A mains electricity-powered (AC-powered) component of a microwave ablation/electrosurgical system intended to generate both: 1) radio-frequency (RF) electrical current; and 2) microwave energy for subsequent cutting, coagulation, and ablation of soft tissues during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues. It includes controls, may include an integrated surgical plume (smoke) suction unit, and is intended to be connected via a cable to an electrosurgical handpiece and electrode (neither of these are included); it is not intended for argon-enhanced electrosurgery.
A mains electricity-powered (AC-powered) component of a microwave ablation/elect
A mains electricity-powered (AC-powered) component of a microwave ablation/electrosurgical system intended to generate both: 1) radio-frequency (RF) electrical current; and 2) microwave energy for subsequent cutting, coagulation, and ablation of soft tissues during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues. It includes controls, may include an integrated surgical plume (smoke) suction unit, and is intended to be connected via a cable to an electrosurgical handpiece and electrode (neither of these are included); it is not intended for argon-enhanced electrosurgery.
A non-patient-contact, insulated, electrical cord with a connector (plug) at bot
A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device). It is not intended to connect directly to patient-worn electrodes (i.e., it is not a lead), is not intended to connect to the mains (i.e., not a mains power cable), does not generate any type of power and/or signal, and has no additional non-electrical conducting or processing functionality. Some types may include an electrical isolator to prevent electrical shocks, and/or a cable cover. This is a single-use device.
A non-patient-contact, insulated, electrical cord with a connector (plug) at bot
A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device). It is not intended to connect directly to patient-worn electrodes (i.e., it is not a lead), is not intended to connect to the mains (i.e., not a mains power cable), does not generate any type of power and/or signal, and has no additional non-electrical conducting or processing functionality. Some types may include an electrical isolator to prevent electrical shocks, and/or a cable cover. This is a single-use device.
A sterile, flexible, invasive, endoscopic device assembly intended to deliver: 1
A sterile, flexible, invasive, endoscopic device assembly intended to deliver: 1) a submucosal lifting solution; 2) an electrosurgical current in a bipolar configuration to tissues for cutting; and 3) microwave energy to tissues for coagulation. It is typically intended to treat gastrointestinal mucosal polyps/lesions through lifting of the diseased mucosa over a bubble of fluid, and subsequent electrosurgical excision of the diseased area. It includes a submucosal injection needle, an electrosurgical electrode, and a microwave tip, connected by a flexible sheath to a handpiece which includes controls (e.g., needle deployment control)/solution injection port. This is a single-use device.