Other products from "INFRAREDX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00857595006005 TVC-MC8-B1 TVC-MC8-B1 Individual Sterile Barrier for TVC-MC8 or TVC-MC9 System Controller IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation TVC Controller Sterile Barrier
2 00857595006425 TVC-MC9 TVC-MC9 TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32).Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
3 00857595006418 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
4 00857595006401 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging. Non-RoHsIndications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
5 00857595006234 TVC-C195-42 TVC-C195-42 The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, dispo The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, disposable coronary catheter and accessory kit designed for use only with the Makoto Intravascular Imaging System™ (TVC-MC10 and TVC-MC10i). The dual-modality intravascular imaging catheter combines 50 MHz Extended Bandwidth IVUS transducer and laser-based near infrared spectroscopy (NIRS) for simultaneous acquisition of vessel structure and plaque composition data— a single catheter, a single pullback, two sets of data. The Dualpro™ IVUS+NIRS Imaging Catheter features a durable hydrophilic coating for improved deliverability.Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Dualpro™ IVUS+NIRS Imaging Catheter Kit
6 04543660023515 GLGMF-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.The OKAY® II Y-Connector Set reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y-connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
7 04543660023492 GLGMF-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
8 04543660023485 GLGMN-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
9 04543660022341 YOK0B OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector
10 00857595006210 TVC-C195-22 TVC-C195-22 Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC-C195-22) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
11 00857595006203 TVC-C195-20 TVC-C195-20 Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single us Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer.Indications for Use: 1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OBJ,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Cat System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
12 04543660022662 GM-30NL GM-30NL 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubi 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubing and 3 position stopcock for balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
13 04543660022655 GM-30NF GM-30NF 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
14 04543660022648 GM-30N GM-30N 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 3 position stopcock for angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
15 04543660022334 YOK0A OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector Set
16 04543660022358 YOK0E OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector Set with Extension Tube
17 00857595006227 TVC-C195-32 TVC-C195-32 Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Cathet Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Catheter Kit (TVC-C195-32) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™(TVC-MC9, TVC-MC9i, and properly configured TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and 50 MHz Extended Bandwidth ultrasonics for simultaneous acquisition of vessel structure and plaque composition— a single catheter, a single pullback, two sets of data. The Insight XB catheter features a 50MHz Extended Bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight XB™
18 00857595006623 TVC-MC9i TVC-MC9i TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. This model of TVC Imaging System is designed to be installed in the catheterization laboratory and minimize usage of space. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32). Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Integrated Imaging System™
19 00857595006432 TVC-MC10 TVC-MC10 The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravasc The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated Extended Bandwidth IVUS imaging and NIRS (near infrared spectroscopy) technologies to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50 MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42). Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Makoto Intravascular Imaging System™
Other products with the same Product Codes "PTM, DTL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00803622129384 Connector Connector LIVANOVA USA, INC.
2 00803622129377 Spike Spike LIVANOVA USA, INC.
3 00803622129360 Connector Connector LIVANOVA USA, INC.
4 00803622129353 Connector Connector LIVANOVA USA, INC.
5 00803622129346 Connector Connector LIVANOVA USA, INC.
6 00803622129339 Connector Connector LIVANOVA USA, INC.
7 00803622129322 Connector Connector LIVANOVA USA, INC.
8 00803622129315 Connector Connector LIVANOVA USA, INC.
9 00803622129308 Connector Connector LIVANOVA USA, INC.
10 00803622129292 Connector Connector LIVANOVA USA, INC.
11 00803622129285 Connector Connector LIVANOVA USA, INC.
12 00803622129278 Connector Connector LIVANOVA USA, INC.
13 00803622128394 AX-xxxxx Assy, Venous Drainage, Cannula Conversion, 1/2 LIVANOVA USA, INC.
14 00803622128387 AX-xxxxx Assy, Venous Drainage, Cannula Conversion, 3/8 LIVANOVA USA, INC.
15 00803622124983 Smart Connector Smart Connector LIVANOVA USA, INC.
16 00803622124976 Smart Connector Smart Connector LIVANOVA USA, INC.
17 00803622124969 Smart Connector Smart Connector LIVANOVA USA, INC.
18 00803622124952 Smart Connector Smart Connector LIVANOVA USA, INC.
19 00803622123405 Connector Connector LIVANOVA USA, INC.
20 00803622123399 Connector Connector LIVANOVA USA, INC.
21 00803622123382 Connector Connector LIVANOVA USA, INC.
22 00803622123375 Connector Connector LIVANOVA USA, INC.
23 00803622123368 Connector Connector LIVANOVA USA, INC.
24 00803622123351 Connector Connector LIVANOVA USA, INC.
25 00803622123344 Connector Connector LIVANOVA USA, INC.
26 00803622123337 Connector Connector LIVANOVA USA, INC.
27 00803622123320 Connector Connector LIVANOVA USA, INC.
28 00803622123313 Connector Connector LIVANOVA USA, INC.
29 00803622123306 Connector Connector LIVANOVA USA, INC.
30 00803622123290 Connector Connector LIVANOVA USA, INC.
31 00803622123283 Connector Connector LIVANOVA USA, INC.
32 00803622123276 Connector Connector LIVANOVA USA, INC.
33 00803622123269 Connector Connector LIVANOVA USA, INC.
34 00803622123252 Connector Connector LIVANOVA USA, INC.
35 00803622123245 Connector Connector LIVANOVA USA, INC.
36 00803622123238 Connector Connector LIVANOVA USA, INC.
37 00803622123221 Connector Connector LIVANOVA USA, INC.
38 00803622123214 Connector Connector LIVANOVA USA, INC.
39 00803622123207 Connector Connector LIVANOVA USA, INC.
40 00803622123191 Connector Connector LIVANOVA USA, INC.
41 00803622123184 Connector Connector LIVANOVA USA, INC.
42 00803622123177 Connector Connector LIVANOVA USA, INC.
43 00803622123160 Connector Connector LIVANOVA USA, INC.
44 00803622123153 Connector Connector LIVANOVA USA, INC.
45 00803622106569 AX-xxxxx Connector LIVANOVA USA, INC.
46 00803622106552 AX-xxxxx Connector LIVANOVA USA, INC.
47 00803622106545 AX-xxxxx Connector LIVANOVA USA, INC.
48 00803622106538 AX-xxxxx Connector LIVANOVA USA, INC.
49 00803622106521 AX-xxxxx Connector LIVANOVA USA, INC.
50 00803622103483 AX-xxxxx Connector LIVANOVA USA, INC.