Other products from "INFRAREDX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00857595006005 TVC-MC8-B1 TVC-MC8-B1 Individual Sterile Barrier for TVC-MC8 or TVC-MC9 System Controller IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation TVC Controller Sterile Barrier
2 00857595006425 TVC-MC9 TVC-MC9 TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32).Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
3 00857595006418 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
4 00857595006401 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging. Non-RoHsIndications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
5 00857595006234 TVC-C195-42 TVC-C195-42 The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, dispo The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, disposable coronary catheter and accessory kit designed for use only with the Makoto Intravascular Imaging System™ (TVC-MC10 and TVC-MC10i). The dual-modality intravascular imaging catheter combines 50 MHz Extended Bandwidth IVUS transducer and laser-based near infrared spectroscopy (NIRS) for simultaneous acquisition of vessel structure and plaque composition data— a single catheter, a single pullback, two sets of data. The Dualpro™ IVUS+NIRS Imaging Catheter features a durable hydrophilic coating for improved deliverability.Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Dualpro™ IVUS+NIRS Imaging Catheter Kit
6 04543660023515 GLGMF-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.The OKAY® II Y-Connector Set reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y-connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
7 04543660023508 GLGMN-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
8 04543660023492 GLGMF-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
9 04543660023485 GLGMN-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
10 04543660022341 YOK0B OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector
11 00857595006210 TVC-C195-22 TVC-C195-22 Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC-C195-22) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
12 00857595006203 TVC-C195-20 TVC-C195-20 Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single us Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer.Indications for Use: 1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OBJ,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Cat System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
13 04543660022662 GM-30NL GM-30NL 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubi 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubing and 3 position stopcock for balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
14 04543660022655 GM-30NF GM-30NF 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
15 04543660022648 GM-30N GM-30N 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 3 position stopcock for angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
16 04543660022334 YOK0A OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector Set
17 00857595006227 TVC-C195-32 TVC-C195-32 Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Cathet Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Catheter Kit (TVC-C195-32) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™(TVC-MC9, TVC-MC9i, and properly configured TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and 50 MHz Extended Bandwidth ultrasonics for simultaneous acquisition of vessel structure and plaque composition— a single catheter, a single pullback, two sets of data. The Insight XB catheter features a 50MHz Extended Bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight XB™
18 00857595006623 TVC-MC9i TVC-MC9i TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. This model of TVC Imaging System is designed to be installed in the catheterization laboratory and minimize usage of space. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32). Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Integrated Imaging System™
19 00857595006432 TVC-MC10 TVC-MC10 The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravasc The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated Extended Bandwidth IVUS imaging and NIRS (near infrared spectroscopy) technologies to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50 MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42). Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Makoto Intravascular Imaging System™
Other products with the same Product Code "DTL"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10888277577701 DYKM1090 DYKM1090 STOPCOCK KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
2 10888277027183 DYNJ43119 DYNJ43119 CSTM MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
3 10885403051852 HY23156 HY23156 V. Mueller STOPCOCK FEMALE TO MALE LUER-LOCK TIP & FEMALE LUER-LOCK RIGHT SIDE CONNECTION V. Mueller CAREFUSION 2200, INC
4 10885403051845 HY23152 HY23152 V. Mueller STOPCOCK FEMALE LUER-LOCK TIP TO MALE LUER-LOCK V. Mueller CAREFUSION 2200, INC
5 10885403051838 HY23150 HY23150 STOPCOCK FEMALE TO MALE LUER-LOCK & RIGHT HOSE END FOR RUBBER OR PLASTIC TUBING V. Mueller CAREFUSION 2200, INC
6 10885403051821 HY23138 HY23138 AYER STOPCOCK FEMALE LUER-LOCK TO MALE LUER SLIP PLUS FEMALE LUER-LOCK RIGHT SID AYER STOPCOCK FEMALE LUER-LOCK TO MALE LUER SLIP PLUS FEMALE LUER-LOCK RIGHT SIDE CONNECTION V. Mueller CAREFUSION 2200, INC
7 10885403051814 HY23135 HY23135 STOPCOCK FEMALE LUER-LOCK TIP TO MALE LUER SLIP V. Mueller CAREFUSION 2200, INC
8 10885403051807 HY23113 HY23113 LUER LOCK ADAPTER MALE LUER TO MALE LUER V. Mueller CAREFUSION 2200, INC
9 10885403051784 HY23092 HY23092 V. Mueller LUER LOCK ADAPTER FEMALE LUER LOCK TO CATHETER OVERALL LENGTH 1-1/2" (3.7CM) V. Mueller CAREFUSION 2200, INC
10 10885403051753 HY23075 HY23075 LUER LOCK ADAPTER FEMALE LUER TO MALE LUER V. Mueller CAREFUSION 2200, INC
11 10884450295165 10884450295165 U1SHC/A Merit Medical Flow Control Switch™ MERIT MEDICAL SYSTEMS, INC.
12 10884450293468 10884450293468 U1SHC-Y Merit Medical Flow Control Switch™ MERIT MEDICAL SYSTEMS, INC.
13 10884450293451 10884450293451 U1SHC-R Merit Medical Flow Control Switch™ MERIT MEDICAL SYSTEMS, INC.
14 10884450090012 10884450090012 U1SHC Merit Medical Flow Control Switch™ MERIT MEDICAL SYSTEMS, INC.
15 10884389918425 CDS985003 CDS985003 BYPASS ENCOMPASS CDS Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
16 10884389369807 DYK100MRSA DYK100MRSA MRSA PROTECTION KIT W/BASIC Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
17 10841156101992 IPN914200 FH102-T Guardian II NC Torque GUARDIAN TELEFLEX INCORPORATED
18 10841156101985 IPN914199 FH102-50 Guardian II NC Torque 50cm Ext GUARDIAN TELEFLEX INCORPORATED
19 10841156101978 IPN914198 FH102-25 Guardian II NC Torque 25cm Ext GUARDIAN TELEFLEX INCORPORATED
20 10841156101961 IPN914197 FH102 Guardian II NC GUARDIAN TELEFLEX INCORPORATED
21 10841156101954 IPN914196 FH101-T Guardian II Torque GUARDIAN TELEFLEX INCORPORATED
22 10841156101947 IPN914195 FH101-50 Guardian II Torque 50cm Ext GUARDIAN TELEFLEX INCORPORATED
23 10841156101930 IPN914194 FH101-25 Guardian II Torque 25cm Ext GUARDIAN TELEFLEX INCORPORATED
24 10841156101923 IPN914193 FH101 Guardian II GUARDIAN TELEFLEX INCORPORATED
25 10841156101367 IPN914182 8216 Guardian II NC Intro Torque GUARDIAN TELEFLEX INCORPORATED
26 10841156101350 IPN914181 8215 Guardian II NC Intro GUARDIAN TELEFLEX INCORPORATED
27 10841156101343 IPN914180 8211 Guardian II Intro Torque GUARDIAN TELEFLEX INCORPORATED
28 10841156101336 IPN914179 8210 Guardian II Hemostasis Valve GUARDIAN TELEFLEX INCORPORATED
29 10351688510037 MX1336LB Medex SMITHS MEDICAL ASD, INC.
30 10351688508379 MX220 Medex SMITHS MEDICAL ASD, INC.
31 10351688508034 MX336LB Medex SMITHS MEDICAL ASD, INC.
32 10351688508027 MX339 Medex SMITHS MEDICAL ASD, INC.
33 10351688508010 MX342 Medex SMITHS MEDICAL ASD, INC.
34 10193489906929 ART1055 ART1055 KIT PRESSURE INFUSER 84IN Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
35 10193489694093 SAMPC0609 SAMPC0609 DOUBLE MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
36 10193489688887 SAMPC0604 SAMPC0604 CUSTOM MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
37 10193489671995 VASC1200 VASC1200 KIT MANIFOLD CSTM - RIVER CITY Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
38 10193489666533 DYNJ45161B DYNJ45161B RH W/OUT MANIFOLD WAUSAU HOSP Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
39 10193489664263 VASC1198 VASC1198 CRYO EP MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
40 10193489664188 VASC1182 VASC1182 KIT CSTM MANIFOLD-VA MED Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
41 10193489657685 SAMPC0569 SAMPC0569 DOUBLE MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
42 10193489657678 SAMPC0568 SAMPC0568 SINGLE MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
43 10193489623154 SAMPC0551 SAMPC0551 CUSTOM MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
44 10193489615470 SAMPC0538 SAMPC0538 CSTM MANIFOLD KIT-WEST VALLEY Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
45 10193489609226 SAMPC0535 SAMPC0535 KIT ANGIO CUSTOM Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
46 10193489606805 125722 125722 KIT MANIFOLD CSTM-UC DAVIS Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
47 10193489606584 VASC1189 VASC1189 SINGLE MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
48 10193489602685 VASC1188 VASC1188 CSTM MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
49 10193489596212 VASC1183 VASC1183 CSTM MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.
50 10193489593488 SAMPC0530 SAMPC0530 CSTM MANIFOLD KIT Medline Industries, Inc. MEDLINE INDUSTRIES, INC.