TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravas
TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32).Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas
TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas
TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging. Non-RoHsIndications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, dispo
The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, disposable coronary catheter and accessory kit designed for use only with the Makoto Intravascular Imaging System™ (TVC-MC10 and TVC-MC10i). The dual-modality intravascular imaging catheter combines 50 MHz Extended Bandwidth IVUS transducer and laser-based near infrared spectroscopy (NIRS) for simultaneous acquisition of vessel structure and plaque composition data— a single catheter, a single pullback, two sets of data. The Dualpro™ IVUS+NIRS Imaging Catheter features a durable hydrophilic coating for improved deliverability.Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.The OKAY® II Y-Connector Set reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y-connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with
This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC
Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC-C195-22) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single us
Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer.Indications for Use: 1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubi
30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubing and 3 position stopcock for balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi
30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi
30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 3 position stopcock for angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon.
OKAY II reduces blood loss during procedures through the use of a hemostatic val
OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.
OKAY II reduces blood loss during procedures through the use of a hemostatic val
OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.
Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Cathet
Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Catheter Kit (TVC-C195-32) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™(TVC-MC9, TVC-MC9i, and properly configured TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and 50 MHz Extended Bandwidth ultrasonics for simultaneous acquisition of vessel structure and plaque composition— a single catheter, a single pullback, two sets of data. The Insight XB catheter features a 50MHz Extended Bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular
TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. This model of TVC Imaging System is designed to be installed in the catheterization laboratory and minimize usage of space. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32). Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravasc
The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated Extended Bandwidth IVUS imaging and NIRS (near infrared spectroscopy) technologies to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50 MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42). Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.
A collection of sterile, flexible, double-bore tubing, and associated items (typ
A collection of sterile, flexible, double-bore tubing, and associated items (typically includes clamps, filters, spikes, and connectors), used as twin conduits in a surgical irrigation/aspiration system to deliver irrigation solution to a surgical field through one bore and provide aspiration (suction) through the other during a surgical procedure (e.g., tissue/bone morcellation, ENT, neuro and general surgery). The tubing is made of synthetic material and is of a fixed diameter that may be specific to the requirements of the clinical application for which it is intended. This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A sterile device designed to facilitate/regulate the delivery of cardioplegic so
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
A small, sterile device with a locking/holding mechanism designed to secure most
A small, sterile device with a locking/holding mechanism designed to secure most any kind of tubing or tubing-like device (e.g., cables, cords) to a patient or to a surgical drape during a clinical intervention. It is typically designed as: 1) an adhesive pad (plaster), strip, or bandage intended to attach to the patient's skin or drape with the exposed side (top side) having an integrated fixation mechanism (e.g., Velcro hook/loop closure); or 2) a mechanical closure or gripping system intended to hold the tubing or tubing hub in place. This device is not designed to hold a specific type or brand of tubing. This is a single-use device.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A small, sterile device intended to connect an intravenous (IV) fluid bag or blo
A small, sterile device intended to connect an intravenous (IV) fluid bag or blood bag to a fluid line to administer fluid to a patient. It consists of a plastic hollow spike at one end intended to be inserted into the IV bag port, a connector at the other end to attach to the IV line (typically via a drip chamber) and may include an additional administration port (i.e., Y-site device). It does not include a built-in drip chamber. This is a single-use device.
A small, sterile device intended to connect an intravenous (IV) fluid bag or blo
A small, sterile device intended to connect an intravenous (IV) fluid bag or blood bag to a fluid line to administer fluid to a patient. It consists of a plastic hollow spike at one end intended to be inserted into the IV bag port, a connector at the other end to attach to the IV line (typically via a drip chamber) and may include an additional administration port (i.e., Y-site device). It does not include a built-in drip chamber. This is a single-use device.
1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO
1/2" TUBING TO FIT OVER THE CORONARY PERFUSION OULTET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBILITY OF THE PORT BEING INADVERTENTLY OPENED DURING THE HEMOPERFUSION PROCEDURE.
1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO
1/2 TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE.
1/4" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO
1/4" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE.
1/4" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO
1/4" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer
A sterile, semi-rigid tube used in open heart surgery to facilitate the transfer of priming fluids during the priming of the extracorporeal circuit of a cardiopulmonary bypass system. It is a noninvasive product in the form of a tube or tubing used to channel the fluids (i.e., primer/blood) to facilitate priming of the extracorporeal circuit and connection of the cardiopulmonary bypass system (heart/lung machine) to the patient. It is typically a moulded plastic tube with hard plastic spike at the distal end that connects to the bag or container of primer solution, a connector at the proximal end, and a central pinch clamp. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
A sterile plastic device designed to join two or more tubes of a cardiopulmonary
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
3/8" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO
3/8" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE.
3/8" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO
3/8" TUBING TO FIT OVER THE CORONARY PERFUSION OUTLET PORT OF AN OXYGENATOR, TO SECURELY SEAL OFF THE PORT, THUS REDUCING THE POSSIBLITY OF THE PORT BEING INADVERTENTLY OPENED DUTING THE HEMOPERFUSION PROCEEDURE.
A non-sterile device designed to connect together two or more tubes typically wi
A non-sterile device designed to connect together two or more tubes typically with the intention of creating an extension. The connecting ends of this device will typically be serrated to provide a secure grip for the applied tubes. Clips or other forms of locking devices may be applied over the tubes to further secure the fitting. This device will not be appropriate for connecting tubes that are designed to carry (withstand) high pressures [e.g., high pressure gases]. This is a single-use device.
A small, noninvasive, closed-ended Luer attachment intended to be attached to a
A small, noninvasive, closed-ended Luer attachment intended to be attached to a luminal device (e.g., catheter, intravenous administration or pressure-monitoring tubing, syringe) with a Luer connection to close the device lumen, typically to prevent fluid path contamination and/or spillage; it is not intended to disinfect/maintain disinfection. It is typically made of synthetic polymers and may incorporate a strap; it does not incorporate a filter or valve. This is a single-use device.